• Title/Summary/Keyword: Slip-down

Search Result 84, Processing Time 0.021 seconds

A Study on an Optimal Design of Electric Snow Melting Mat for Vulnerable Walk Zone (제설기반 취약지역 보행자의 전기안전발판(융설용) 최적설계에 관한 연구)

  • Kwon, Jin Wook;Jang, Chul;Hwang, Myung Whan
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.12-18
    • /
    • 2016
  • This paper describes an optimal design of electric snow melting mat on vulnerable walk zone. In order to design an optimal electric power of snow melting mat and protect pedestrians with a nonslip mat, with considering protection of environmental pollution from abusing of the de-icing salts added calcium chloride. We analyzed nine snow melting mats through verification experiment in the condition of $-5^{\circ}C$, depending on three different kinds of heating material, electric heating cable, carbon heating film and carbon textile film. As a consequence, the $150W/m^2$ carbon textile film mat for snow melting was identified as an optimal power input and functional performance for pedestrians' safety on vulnerable walk zone. It is expected that the $150W/m^2$ carbon textile film mat would be useful to reduce slip down accidents by human error.

Facial Bone Fracture Patients Visiting Pusan National University Hospital in Busan and Yangsan: Trends and Risks

  • Kim, Hyo-Geon;Son, Yong-Hyun;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.4
    • /
    • pp.140-145
    • /
    • 2014
  • Purpose: This study examined patients with facial bone fracture visiting Pusan National University Dental Hospital to understand the trends, and to enhance appropriate care and treatment for patients with facial bone fracture. Methods: We investigated 531 patients presenting with facial bone fracture in Yangsan and 802 patients in Busan from January 2010 to December 2013. We divided the patients by year, month, gender, age, site, and cause to compare with historic data and other studies. Results: The gender ratio was 3.58:1 in Yangsan and 4.31:1 in Busan. Patients aged in their 20s had the highest number of facial bone fractures in both Yangsan and Busan. The most frequent fracture site was the mandible, and the most frequent cause was slip down in both Yangsan and Busan. Conclusion: The investigation and comparison of patients with facial bone fracture who visited Pusan National University Hospital located at Yangsan and Busan from 2010 to 2013 found a difference in the total number of patients at each hospital, but the trends were not significantly different.

Surgical Treatment of Idiopathic Chylothorax in Infant -1 case report- (영아에서 발생한 특발성 유미흉)

  • 강두영;이창영;김도형;임승균;이두연
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.456-459
    • /
    • 2004
  • A 16 month old male infant was found with slip down state in a bath room without evidence of trauma to whole body. The infant was treated with several thoracentesis and closed drainage due to persistent right pleural effusion at other hospital and transferred to our hospital for further evaluation and treatment at July 2003. The pleural effusion was confirmed as chylothorax by chemical analysis. He was treated with parenteral feeding for 21 days. Because the amount of chest tube drainage was about 110∼210 cc/day, and could not be decreased with conservative treatment. patients underwent ligation of thoracic duct. Post-operative course was uneventful except post-op. empyema thoracis, The open drainage tube was removed at post operative 30 days, The patient was in very good condition with complete cure until post-operative 3 months.

Percutaneous Vertebroplasty in Treatment of Osteoporotic Vertebral Body Fractures : Early Result (골다공증성 추체골절에 대한 경피적 척추성형술 : 초기성적)

  • You, Young Sang;Shin, Jae Hack;Kim, Il-Man
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.163-167
    • /
    • 2001
  • Objective : Percutaneous vertebroplasty has recently been introduced as an interesting therapeutic alternative for the treatment of thoracolumbar vertebral body fractures in elderly persons with osteoporosis. The authors present the early results of this method. Method and Material : From July 1999 to April 2000, percutaneous transpedicular technique was used in 20 patients (2 men and 18 women) whose mean age was 67.5 years old(range 59-79) with painful vertebral compression(22) and burst(2) fractures. The interval between fracture and vertebroplasty ranged 1 day to 4 months. The procedure involved percutaneous puncture of the injured vertebra via transpedicular approach under fluoroscopic guidance, followed by injection of polymethylmetacrylate(PMMA) into the vertebral body through a disposable 11-guage Jamshidi needle. Result : The most common cause of fracture was slip down and the most frequent injured level was the twelfth thoracic spine. The procedure was technically successful bilaterally in 18 patients(9 thoracic and 15 lumbar spines) with an average injection amount of 7.7ml PMMA in each level. Seventeen(94.4%) patients reported significant pain relief immediately after treatment. Two leaks of PMMA were detected with postoperative CT in spinal epidural space and extravertebral soft tissue without clinical symptoms. Conclusion : Although this study represents the early results, percutaneous vertebroplasty seems to be valuable tool in the treatment of painful osteoporotic vertebral body fractures in elderly, providing acute pain relief and early mobilization.

  • PDF

Characteristics of Head Injuries After Skiing and Snowboarding Accident (스키와 스노보드 사고에서 두부손상의 특징)

  • Kang, Sung Chan;Lee, Kang Hyun;Choi, Han Joo;Park, Kyung Hye;Kim, Sang Chul;Kim, Hyun;Hwang, Sung Oh
    • Journal of Trauma and Injury
    • /
    • v.21 no.1
    • /
    • pp.53-58
    • /
    • 2008
  • Purpose: Skiing and snowboarding are becoming increasingly popular. Accordingly, the incidences of injuries among skiers and snowboarders are also increasing. The purpose of this study was to investigate the injury patterns of and the contributing factors to head injuries of skiers and snowboarders and to evaluate the differences in characteristics between skiing and snowboarding head injuries. Methods: One-hundred patients who visited the emergency department of Wonju Christian Hospital between January 2005 and March 2007 due to head injuries from skiing and snowboarding were enrolled. The mechanisms and the histories of the injuries were investigated by surveying the patients, and the degrees of head injuries were estimated by using brain CT and the Glasgow Coma Scale. The degrees and the characteristics of brain injuries were also analyzed and compared between skiers and snowboarders. Results: Out of 100 patients, 39 were injured by skiing, and 61 were injured by snowboarding. The mean age of the skiers was $26.7{\pm}10.0$, and that of the snowboarders was $26.7{\pm}6.2$. The percentage of male skiers was 43.6%, and that of snowboarders was 63.9%. The most frequent initial chief complaints of head-injured skiers and snowboarders were headache and mental change. The most common mechanism of injuries was a slip down. The mean Abbreviated Injury Scale Score (AIS score) of the skier group was $4.5{\pm}2.1$ and that of the snowboarder group was $5.9{\pm}5.0$ (p=0.222). The percentage of helmet users was 7.1% among skiers and 20.8% among snowboarders (p=0.346). Head injuries were composed of cerebral concussion (92.0%) and intracranial hemorrhage (8.0%). Intracranial hemorrhage was most frequently caused by falling down (62.5%). Conclusion: The most common type of head injury to skiers and snowboarders was cerebral concussion, and severe damage was usually caused by jumping and falling down. No differences in the characteristics of the head injuries existed between skiing and snowboarding injuries.

Static Behavior of Stud Shear Connector for UHPC Deck (초고성능 콘크리트 바닥판을 위한 스터드 전단연결재의 정적 거동)

  • Lee, Kyoung-Chan;Kwark, Jong-Won;Park, Sang-Hyeok;Kim, Jee-Sang
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.573-579
    • /
    • 2014
  • Typical composite girder has been composed with conventional concrete deck and steel girder. Recently, ultrahigh-performance-concrete (UHPC) deck is proposed in order to enhance durability and reduce weight of deck as well as to increase stiffness and strength of the composite girder. This study investigates that a headed stud is still compatible as a shear connector for the UHPC deck and steel girder composite beam. Twelve push-out specimens are prepared to evaluate the static strength of stud shear connectors embedded in the UHPC deck. The test program proves that the static strength of the stud shear connectors embedded in UHPC well meets with design codes described in AASHTO LRFD. Chosen experimental variables are aspect ratio of height to diameter of stud, thickness of deck and thickness of concrete cover over the head of stud. From the test program, aspect ratio and cover thickness are investigated to mitigate the regulations of the existing design codes. The minimum aspect ratio and the minimum cover thickness given in AASHTO LRFD are four and 50mm, respectively. This limitation hinders to lower the thickness of the UHPC deck. The results of the experiment program give that the aspect ratio and the cover thickness can be lower down to three and 25mm, respectively. Eurocode-4 regulates characteristic relative slip at least 6mm. However, test results show that stud shear connectors embedded in UHPC provide the characteristic relative slip only about 4mm. Therefore, another measures to increase ductility of stud should be prepared.

Characteristics of NOx Reduction and NH3 Slip in SNCR Using Pipe Nozzle for the Application of Hybrid SNCR/SCR Process (Hybrid SNCR/SCR 탈질공정에서 SNCR의 관통노즐에 의한 NOx 저감 및 NH3 Slip 특성)

  • Hyun, Ju Soo
    • Korean Chemical Engineering Research
    • /
    • v.47 no.1
    • /
    • pp.111-118
    • /
    • 2009
  • A hybrid SNCR/SCR plant was designed and manufactured, and experimented on the SNCR process in the first step to investigate the optimum operation conditions of SNCR, with the equivalence ratio of the reducing agent(NSR, 0.5~5.0), reaction temperature($850{\sim}1,100^{\circ}C$), nozzle type(wall nozzle, pipe nozzle), and nozzle position as variables. In the case of wall nozzles, the NOx reduction efficiency rapidly increased to 87% at 2.5 NSR and slowed down after this. Compared to the upward spray from the pipe nozzle, wall nozzles have narrower range of applicable reaction temperature. In the case of pipe nozzles, it rapidly increased to 77% at 1.5 NSR. But the pipe nozzle downward had no NOx reduction efficiency; on the contrary, NOx increased. When the reducing agent was sprayed upward from a pipe nozzle, the NOx reduction efficiency was 50~75% in the range of 0.5~1.5 NSR, and the NOx reduction efficiency was constant without fluctuations even in the change of reaction temperature from 890 to $1,000^{\circ}C$. When 5% urea solution was sprayed upward from the pipe nozzle, 200 ppm NOx decreased to approximately 60 ppm at 1.2 NSR, and the non-reacted $NH_3$ was 50~100 ppm. In this condition, we expect over 90% NOx reduction efficiency without additional supply of $NH_3$ to SCR at the back of SNCR.

Preferences of Stroke Patients for Kitchen Environment in Residential Space (주거공간의 부엌 환경 특성에 대한 뇌졸중 환자의 선호)

  • Baek, Da-Rae;Jung, Yeon-Jin;Kang, Suk-Gu;Kim, Hee-Jung;Lee, Chun-Yeop
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 2014
  • Objective : The purpose of this study was to investigate the preferences of kitchen environment for stroke patients. Methods : The subjects of this study were 97 who have experience in rehabilitation therapy at hospitals in Busan. A questionnaire was distributed and collected from February 24th to March 13th, 2014. Descriptive statistics of frequency Study were used to analyze data. Results : First, the subjects demand for improvement that use a chair for work and install non-slip tiles. Second, they preferred the non-slip mat, boilers in heating equipment, drawer storage, L-shaped safety handle, adjustable sink of the height, automatic cutout of gas leak, faucet of touch-sensitive type, ㄷ-shaped kitchen and the ceiling-type hood in ventilation system. Third, they need kitchen items such as the sink self coming down, scissors for slices and knife to avoid hand injury. Conclusion : This study would contribute to kitchen environment for fall prevention and ease in use.

  • PDF

The Clinical Study on Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) Acupuncture Treatment of Patient with Thoracolumbar Compression Fracture (흉(胸)·요추압박골절(腰椎壓迫骨折) 환자(患者)의 화타협척혈 침치료(鍼治療)에 대한 임상적 고찰)

  • Song, Won-sub;Hwang, Jae-Yeon;Shin, Young-Il;Lee, Byung-Ryul
    • Journal of Acupuncture Research
    • /
    • v.18 no.4
    • /
    • pp.55-67
    • /
    • 2001
  • Objective : This study was performed to evaluate result of thoracolumbar compression fracture patient treated with Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) acupuncture. Methods : This clinical study was carried out 50 cases with thoracolumbar compression fracture, who had been admitted from January, 2000 to February, 2001, in the department of acupuncture and moxibustion, Hanseo University Oriental Medical Hospital. We divided two groups; A group, without using Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) acupuncture and the other group is B group, by using Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) acupuncture. Results : 1. The distribution of sex and age, 78% were female, and 84% were most above there sixties. 2. In the duration of symptom, the largest group was over 4 weeks. 3. In the distribution of cause, the largest group was "lifting heavy object"(32%) and the next was "slip down"(26%). 4. In the distribution of injured level was L1 body the most(19.6%) and T12 body was the next. 5. In the distribution of clinical symptoms on the admission, the largest group was lumbosacral pain(18%). 6. The result of treatment due to the duration of admission, 17case(34%) was the most above "Fair" during the 2~3 weeks. 7. The result of treatment, Good and Fair were the same in 24case(48%). 8. The duration of treatment was longer in high grade of clinical symptom. 9. B group discharged above good state 60% higher than A group.

  • PDF

Behavioral Characteristics Investigation of Rack Structure Depending on Forklift Impact Scenarios and Storage Distributions (지게차 충돌 위치 및 보관물류 분포에 따른 선반구조물의 거동특성분석)

  • Ok, Seung-Yong;Kwon, Oh-Yong;Paik, Shin Won
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.6
    • /
    • pp.49-56
    • /
    • 2013
  • The statistics of recent accidents in warehouses show that a heavy toll of lives were produced by various accidents, e.g. collision, overturn, fall, slip, exposure to harmful substances or environments, etc. Of significant concern amongst them is the collision, especially the collision between forklift and storage rack structure. Accordingly, this study focuses on behavioral characteristics of rack structure subjected to dynamic impact loading of a forklift. For this purpose, time-domain response analysis has been performed on a standard 2-bay six-story rack structure consisting of columns, beams and bracing members with perforated open section. In order to investigate the most critical scenario, the impact loads are applied in both down-aisle and cross-aisle directions, and the impact locations are also varied along the shelves of the palettes. In order to deal with storage distributions, three types of rack structures are further taken into account: original empty rack structure with no storage, half-loaded rack structure and fully-loaded rack structure. The numerical simulation results demonstrate that the dynamic characteristics of the rack structure are significantly dependent on the distribution of the storage goods and its natural period varies from 0.24sec to 1.06sec, approximately 4.4 times. Further, the parametric studies show that the forklift impact is most critical to the safety of the rack structure when it collides either at the base or at the top of the rack structure.