• Title/Summary/Keyword: Sliding Doors

Search Result 18, Processing Time 0.022 seconds

Full-scale simulation of wind-driven rain and a case study to determine the rain mitigation effect of shutters

  • Krishna Sai Vutukuru;James Erwin;Arindam Gan Chowdhury
    • Wind and Structures
    • /
    • v.38 no.3
    • /
    • pp.171-191
    • /
    • 2024
  • Wind Driven Rain (WDR) poses a significant threat to the building environment, especially in hurricane prone regions by causing interior and content damage during tropical storms and hurricanes. The damage due to rain intrusion depends on the total amount of water that enters the building; however, owing to the use of inadequate empirical methods, the amount of water intrusion is difficult to estimate accurately. Hence, the need to achieve full-scale testing capable of realistically simulating rain intrusion is widely recognized. This paper presents results of a full-scale experimental simulation at the NHERI Wall of Wind Experimental Facility (WOW EF) aimed at obtaining realistic rain characteristics as experienced by structures during tropical storms and hurricanes. A full-scale simulation of rain in strong winds would allow testing WDR intrusion through typical building components. A study of rain intrusion through a sliding glass door is presented, which accounted for the effects of multiple wind directions, test durations and wind speeds; configurations with and without shuttering systems were also considered. The study showed that significant levels of water intrusion can occur during conditions well below current design levels. The knowledge gained through this work may enhance risk modeling pertaining to loss estimates due to WDR intrusion in buildings, and it may help quantify the potential reduction of losses due to the additional protection from shuttering systems on sliding glass doors during winds.

Development of a Sliding-Plug Entrance Door System for Urban Electric Transit Unit to Reduce Inside Noise Level (전동차 소음저감을 위한 슬라이딩플러그 출입문 개발)

  • 서승일;임영호;신동국
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.2
    • /
    • pp.112-117
    • /
    • 2002
  • Reduction of noise level in the cabin of urban transit unit is an important issue to enhance the comfortability of passengers. It is made clear that a cause of increased noise level in cabin is the imperfect airtightness of entrance doors. In this study, the sliding-plug door system is developed to reduce the noise level of cabins by securing the airtightness of entrance door. The sliding-plug door system is composed of air-driven engine, swing arms, guide rails, guide rollers and locking devices. It is economical owing to using the previous door engine system. It is also adequate for the platform system of our subway station. It was tested to prove the reliability of system and was applied to standard urban transit unit. The effectiveness of noise reduction in cabin resulting form the sliding-plug door system was confirmed by test results.

A comparative study on the architectural characterictics of the recently constructed houses in Kyongsangnam-do with standard housing plan (경남지역 신축 농가주택과 표준주택안의 건축적 특성에 관한 비교연구)

  • 박경옥
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1992.11a
    • /
    • pp.91-101
    • /
    • 1992
  • The aim of this study is to offer the basic data concerning the architectural characteristics of the recently constructed farmhouses built by the residents’ self-planning after 1987, compared with the standard housing plan, for the desirable farmhouse planning. The 77 farmhouses, scattered in Milyang-gun, Yangsan-gun and Ulsan-gun near Ulsan city, were selected for the field measurement and the data, compared with the 14 standard housing plans, were analysed by the qualitative method. The farmhouses studied here showed average size of 25-pyongs(82.5m2) and took the flat slab type of roof by the masonry construction of the red blicks. The characteristics in planning were \circled1 the Anbang placed adjacent above the living room, \circled2 a pare of double-sliding doers for the Anbang. \circled3 a pare of double-sliding doors between the living room and the yard for the openness of the living room, \circled4 a door between the living room and the kitchen, \circled5 the multiuse-room by the kicthen for supplemental use, and \circled6 the storage space as attics secured indoor. The standard housing plans, different from these of the recently constructed farmhouses, placed emphasis on the separativeness of each space using the one hinged doors. The farmhouses built recently therefore were not affected by the characteristics of the standard housing plans.

  • PDF

Thermal Performance Evaluation of Junction Thermal Bridge according to Installation Position of Window

  • Lee, Soo-Man;Kim, Dong-Yun;Ahn, Jung-Hyuk;Eom, Jae-Yong;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: "Building energy design standard" is used to limit the thermal transmittance of building in Korea. However, it only covers the insulation standard for each appropriate elements of a building, not the thermal performance of Junction thermal bridge of windows and doors installed in wall. Therefore in this study, we have evaluated the thermal performance of Junction thermal bridge depending on installation method and position of windows and provide it as design data. Method: We analyzed heat transfer of 4-Track sliding window and tilt & turn triple glazed window that are placed in the first class category on window energy efficiency rating using Window 7.4 and Therm 7.4. Result : First, linear thermal transmittance of 4-Track sliding window differs by 2.2 times or more depending of installation method and location. It is higher than the linear thermal transmittance, 0.01W/mK, proposed by Passivhaus. Second, linear thermal transmittance of Tilt & turn triple glazed window differs by 7.7 times or more depending of installation method and location. The average linear thermal transmittance was less than 0.01W /mK when windows were installed on the internal wall insulation by the fixed hardware attachment method. Third, the thermal losses of a window caused by a junction thermal bridge are inversely proportional to the window area and converge gradually as the area increased.

Conceptual Design of Device Attached to Rotary Type Sliding Door System Using TRIZ and Axiomatic Design (트리즈와 공리적 설계를 활용한, 회전식 중문 슬라이딩 창호 부착 기구의 개념 개발)

  • Lee Kyeong-Won;Kim Hyun-Jun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.299-304
    • /
    • 2005
  • This paper describes the conceptual of device attached to rotary type sliding door system satisfying customer's reguirements. The TRIZ (Russian theory of Inventive Problem Solving) and Axiomatic Design methods are used for generating new ideas at the conceptual design stage efficiently. The ideas will be implemented in real products.

  • PDF

Effect of Lock Operations on Airtightness of Sliding and LS Window Systems (잠금장치 작동에 따른 미서기 및 LS 창호 시스템의 기밀성)

  • Park, Jong Jun;Yun, Yu Ra;Kim, Young Il;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.449-454
    • /
    • 2015
  • In this study, the effects of lock operations on the infiltration rates for the two window types sliding and lift sliding (LS) are investigated through experiment and simulation. The airtightness levels of the two window types-with locks both on and off-were measured according to the KS F 2292 Test method of airtightness that is used for windows and doors. The air-flow rates of both window types with the locks on for a pressure differential of 10 Pa are $1.98m^3/(m^2h)$ and $1.68m^3/(m^2h)$, respectively; with the locks off, the air-flow rates of the sliding and LS windows are $2.64m^3/(m^2h)$ and $5.83m^3/(m^2h)$, respectively, whereby the air-flow rates are 33% higher for sliding and 247% higher for LS. The air change per hour (ACH) was calculated using the ventilation-simulation software CONTAM. For the sliding window, the ACH changed from 0.45 to 0.57 when the lock was operated from on to off, representing an increase of 27%. For the LS window, the ACH changed from 0.29 to 0.81, showing an increase of 179%.

The Remodeling Characteristics of Various Types of Secondary Kitchen in Apartment House (아파트 보조부엌의 유형별 개조특성에 관한 연구)

  • Lee, Joo-Hee;Oh, Chan-Ohk;Yang, Se-Hwa
    • Journal of the Korean housing association
    • /
    • v.18 no.2
    • /
    • pp.65-74
    • /
    • 2007
  • The study analyzes the remodeling characteristics of the four different types of secondary kitchens in apartment house based on their floor plans. The secondary kitchens are categorized into side placement, back placement, back placement with extensions on both sides, and back placement with an extension on a single side. The twelve apartment complexes in Ulsan were selected so that they may all consist each of the four types, and answered the survey. The classified traits of secondary kitchen were examined based on the characteristics of floor plan and remodeling. Side placement and back placement with extensions on both sides mostly used glass hinged doors. Back placement and back placement with a single side extension used glass sliding doors. It was found that the majority of the floor materials consisted of both wood and tiles, except for side placements, where only tiles were used. The sizes of the back placements with both and single side extensions were the largest. The side and back placements were rarely renovated, however, back placements with both and single side extensions went through massive remodeling.

Study on Estimate of Thermal Resistance of PVC Frame Window Due to Material Composition (PVC 창호의 구성에 따른 단열성능 예측에 관한 연구)

  • Sung, Uk-Joo;Lee, Jin-Sung;Cho, Soo;Jang, Cheol-Yong;Paek, Sang-Hun;Song, Kyoo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1075-1080
    • /
    • 2006
  • Purpose of this study is proposal of estimating method about window thermal performance that based on KS F 2278 'Test method of thermal resistance for windows and doors' due to material composition of PVC frame window. First step of this study is research of present state about material composition of PVC frame window. Second is selection of main effective elements about window thermal resistance. For example, composition of Glazing, Frame area ratio of total window area, frame width, opening type, area of heat transfer and so on. Third is multiple regression analysis about thermal performance of PVC frame window due to main effective elements. It produces equations of multiple regression analysis due to opening type. Case of sliding window is $Y=0.149+0.034X_g+0.248X_{far}$, 4track sliding is $Y=0.584+0.175X_g+1.355X_{far}-0.008X_{fw}$, Tilt & Turn window is $Y=-0.161+0.076X_g+0.576X_{far}+0.0008X_{fw}$.

  • PDF

A Study on the process of spatial transfiguration for the Railway Official Residence based on the transition of Social-culture (社會.文化的 變化에 따른 日帝時代 鐵道官舍의 空間變容過程에 관한 硏究)

  • 윤재웅
    • Journal of the Korean housing association
    • /
    • v.8 no.1
    • /
    • pp.23-35
    • /
    • 1997
  • The purpose of this study is to analyze the original plans of the Railway official residence and process of the transfiguration of those plans based on the transition of social-culture, using 54 houses which were built from 1920 to 1945 in Taegu-Kyoungbuk province. In addition, this study was carried out by means of research on the form and pattern, and visual anthropological method by photograph and direct observation. The results of this study are as follows : 1) The original plans of Railway official residences were composed of the entrance hall, TADAMI Rooms, bathroom, toilet and HUSMA(wooden sliding doors). 2) After 1945, the room, kitchen, toilet of Japanese style had been trasfiguerated to Korean traditional style. 3) Since 1980's, those of Korean traditional style has been trasfigurated to the livingroom, dinningroom, entrance hall and etc. of western style.

  • PDF

An Analysis about the Transition of Introduction and the Actual Situation of Management in Open-planned Elementary Schools (오픈플랜형 초등학교 도입추이 및 운영실태 분석)

  • Jeong, Joo-Seong;Rieu, Ho-Seoup
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.16 no.3
    • /
    • pp.49-58
    • /
    • 2009
  • This study is carried out to understand application type and change of learning space and to find out actual situation of management in open planned elementary schools. The twelve elementary schools were selected based on case studies and fundamental data of the agencies performing basic plan, the actual situation of management was studied by interviews of principals and teachers. By the results, open planned elementary schools have been notably reduced after the year of 2004 and corridor expending type was broadly chosen as a plane type for open space. It was also shown that learning space was transformed to the independent type integrating open space to the unit classroom in most part of twelve cases. In addition, whole sliding doors fixed in open classrooms by some Provincial Office of Education didn't need certain physical shut-offs, and it was considered as one of useful alternatives to manage open space.