• 제목/요약/키워드: Slice interval

검색결과 33건 처리시간 0.294초

The Influence of Surface Roughness on Slice Interval Adjustment at FDM (FDM에서 SLICE INTERVAL이 시작품의 표면에 미치는 영향)

  • 하만경;전재억
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • 제11권4호
    • /
    • pp.68-74
    • /
    • 2002
  • The FD process is analogous to the direct piston extrusion process where the cold feed filament acts as a piston extruding the molten filament from the heated liquefier through a nozzle. The extruded filament is deposited on top of futureless platform, where the liquefier and the nozzle move in X and Y direction control by computer based on the part geometry. After the first layer, the Z platform indexes down and the next layer get deposited on top of the first layer. the layer by layer building process introduces surface problem. This paper describes effect of slice interval of the parts built by fused deposition modelling rapid prototyping system.

Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System (Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • 제20권1호
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

Diagnostic Yield of Diffusion-Weighted Brain Magnetic Resonance Imaging in Patients with Transient Global Amnesia: A Systematic Review and Meta-Analysis

  • Su Jin Lim;Minjae Kim;Chong Hyun Suh;Sang Yeong Kim;Woo Hyun Shim;Sang Joon Kim
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1680-1689
    • /
    • 2021
  • Objective: To investigate the diagnostic yield of diffusion-weighted imaging (DWI) in patients with transient global amnesia (TGA) and identify significant parameters affecting diagnostic yield. Materials and Methods: A systematic literature search of the MEDLINE and EMBASE databases was conducted to identify studies that assessed the diagnostic yield of DWI in patients with TGA. The pooled diagnostic yield of DWI in patients with TGA was calculated using the DerSimonian-Laird random-effects model. Subgroup analyses were also performed of slice thickness, magnetic field strength, and interval between symptom onset and DWI. Results: Twenty-two original articles (1732 patients) were included. The pooled incidence of right, left, and bilateral hippocampal lesions was 37% (95% confidence interval [CI], 30-44%), 42% (95% CI, 39-46%), and 25% (95% CI, 20-30%) of all lesions, respectively. The pooled diagnostic yield of DWI in patients with TGA was 39% (95% CI, 27-52%). The Higgins I2 statistic showed significant heterogeneity (I2 = 95%). DWI with a slice thickness ≤ 3 mm showed a higher diagnostic yield than DWI with a slice thickness > 3 mm (pooled diagnostic yield: 63% [95% CI, 53-72%] vs. 26% [95% CI, 16-40%], p < 0.01). DWI performed at an interval between 24 and 96 hours after symptom onset showed a higher diagnostic yield (68% [95% CI, 57-78%], p < 0.01) than DWI performed within 24 hours (16% [95% CI, 7-34%]) or later than 96 hours (15% [95% CI, 8-26%]). There was no difference in the diagnostic yield between DWI performed using 3T vs. 1.5T (pooled diagnostic yield, 31% [95% CI, 25-38%] vs. 24% [95% CI, 14-37%], p = 0.31). Conclusion: The pooled diagnostic yield of DWI in TGA patients was 39%. DWI obtained with a slice thickness ≤ 3 mm or an interval between symptom onset and DWI of > 24 to 96 hours could increase the diagnostic yield.

Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography (영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • 제29권1호
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF

Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images (3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Choi Seong-Ho;Kim Chong-Kwan;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • 제36권2호
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • 제29권3호
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

Region-of-Interest Coding using Sub-Picture Slice Structure (내부 영상 슬라이스 구조를 이용한 관심 영역 부호화)

  • 김우식
    • Journal of Broadcast Engineering
    • /
    • 제7권4호
    • /
    • pp.335-344
    • /
    • 2002
  • A sub-picture slice structure is proposed which can perform the region-of-interest coding effectively, where the subjective quality can be improved by coding the region-of-interest in higher quality than the background region. In addition, the bit allocation mechanism is Proposed where the interval between quantization parameters of the foreground and background region is fixed. And the method to reduce the boundary effect between the foreground and background region is proposed. The foreground region is better protected to the network channel error than the background region. which results in the overall subjective quality improvement in the error prone environments.

Reliability of Coronary Artery Calcium Severity Assessment on Non-Electrocardiogram-Gated CT: A Meta-Analysis

  • Jin Young Kim;Young Joo Suh;Kyunghwa Han;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1034-1043
    • /
    • 2021
  • Objective: The purpose of this meta-analysis was to investigate the pooled agreements of the coronary artery calcium (CAC) severities assessed by electrocardiogram (ECG)-gated and non-ECG-gated CT and evaluate the impact of the scan parameters. Materials and Methods: PubMed, EMBASE, and the Cochrane library were systematically searched. A modified Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to evaluate the quality of the studies. Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and the correlation coefficient of the CAC scores or the weighted kappa for the categorization of the CAC severities detected by the two modalities. The heterogeneity among the studies was also assessed. Subgroup analyses were performed based on factors that could affect the measurement of the CAC score and severity: slice thickness, reconstruction kernel, and radiation dose for non-ECG-gated CT. Results: A total of 4000 patients from 16 studies were included. The pooled bias was 62.60, 95% LOA were -36.19 to 161.40, and the pooled correlation coefficient was 0.94 (95% confidence interval [CI] = 0.89-0.97) for the CAC score. The pooled weighted kappa of the CAC severity was 0.85 (95% CI = 0.79-0.91). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, the agreement between the CAC categorizations was better when the two CT examinations had reconstructions based on the same slice thickness and kernel. Conclusion: The pooled agreement of the CAC severities assessed by the ECG-gated and non-ECG-gated CT was excellent; however, it was significantly affected by scan parameters, such as slice thickness and the reconstruction kernel.

Utility of the 16-cm Axial Volume Scan Technique for Coronary Artery Calcium Scoring on Non-Enhanced Chest CT: A Prospective Pilot Study (비 조영증강 흉부 CT에서 관상동맥 칼슘스코어 측정을 위한 16 cm 축상 촬영 기법의 유용성: 전향적 탐색적 연구)

  • So Jung Ki;Chul Hwan Park;Kyunghwa Han;Jae Min Shin;Ji Young Kim;Tae Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • 제82권6호
    • /
    • pp.1493-1504
    • /
    • 2021
  • Purpose This study aimed to evaluate the utility of the 16-cm axial volume scan technique for calculating the coronary artery calcium score (CACS) using non-enhanced chest CT. Materials and Methods This study prospectively enrolled 20 participants who underwent both, non-enhanced chest CT (16-cm-coverage axial volume scan technique) and calcium-score CT, with the same parameters, differing only in slice thickness (in non-enhanced chest CT = 0.625, 1.25, 2.5 mm; in calcium score CT = 2.5 mm). The CACS was calculated using the conventional Agatston method. The difference between the CACS obtained from the two CT scans was compared, and the degree of agreement for the clinical significance of the CACS was confirmed through sectional analysis. Each calcified lesion was classified by location and size, and a one-to-one comparison of non-contrast-enhanced chest CT and calcium score CT was performed. Results The correlation coefficients of the CACS obtained from the two CT scans for slice thickness of 2.5, 1.25, and 0.625 mm were 0.9850, 0.9688, and 0.9834, respectively. The mean differences between the CACS were -21.4% at 0.625 mm, -39.4% at 1.25 mm, and -76.2% at 2.5 mm slice thicknesses. Sectional analysis revealed that 16 (80%), 16 (80%), and 13 (65%) patients showed agreement for the degree of coronary artery disease at each slice interval, respectively. Inter-reader agreement was high for each slice interval. The 0.625 mm CT showed the highest sensitivity for detecting calcified lesions. Conclusion The values in the non-contrast-enhanced chest CT, using the 16-cm axial volume scan technique, were similar to those obtained using the CACS in the calcium score CT, at 0.625 mm slice thickness without electrocardiogram gating. This can ultimately help predict cardiovascular risk without additional radiation exposure.

Accuracy in target localization in stereotactic radiosurgery using diagnostic machines (정위적 방사선수술시 진단장비를 이용한 종양위치결정의 정확도 평가)

  • 최동락
    • Progress in Medical Physics
    • /
    • 제7권1호
    • /
    • pp.3-7
    • /
    • 1996
  • The accuracy in target localization of CT, MR, and digital angiography were investigated for stereotactic radiosurgery. The images using CT and MR were obtained out of geometrical phantom which was designed to produce exact coordinates of several points within a 0.lmm error range. The slice interval was 3mm and FOV was 35cm for CT and 28cm for MR. These images were transferred to treatment planning computer using TCP/IP in forms of GE format. Measured 3-D coordinates of these images from planning computer were compared to known values by geometrical phantom. Anterior-posterior and lateral films were taken by digital angiography for measurement of spatial accuracy. Target localization errors were 1.2${\pm}$0.5mm with CT images, 1.7${\pm}$0.4mm with MR-coronal images, and 2.1${\pm}$0.7mm with MR-sagittal images. But, in case of MR-axial images, the target localization error was 4.7${\pm}$0.9mm. Finally, the target localization error of digital angiography was 0.9${\pm}$0.4mm. The accuracy of diagnostic machines such as CT, MR, and angiography depended on their resolutions and distortions. The target localization error mainly depended on the resolution due to slice interval with CT and the image distortion as well as the resolution with MR However, in case of digital angiography, the target localization error was closely related to the distortion of fiducial markers. The results of our study should be considered when PTV (Planning Target Volume) was determined.

  • PDF