• 제목/요약/키워드: Slice Interval

검색결과 33건 처리시간 0.027초

FDM에서 SLICE INTERVAL이 시작품의 표면에 미치는 영향 (The Influence of Surface Roughness on Slice Interval Adjustment at FDM)

  • 하만경;전재억
    • 한국공작기계학회논문집
    • /
    • 제11권4호
    • /
    • pp.68-74
    • /
    • 2002
  • The FD process is analogous to the direct piston extrusion process where the cold feed filament acts as a piston extruding the molten filament from the heated liquefier through a nozzle. The extruded filament is deposited on top of futureless platform, where the liquefier and the nozzle move in X and Y direction control by computer based on the part geometry. After the first layer, the Z platform indexes down and the next layer get deposited on top of the first layer. the layer by layer building process introduces surface problem. This paper describes effect of slice interval of the parts built by fused deposition modelling rapid prototyping system.

Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구 (Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System)

  • 윤한식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

Diagnostic Yield of Diffusion-Weighted Brain Magnetic Resonance Imaging in Patients with Transient Global Amnesia: A Systematic Review and Meta-Analysis

  • Su Jin Lim;Minjae Kim;Chong Hyun Suh;Sang Yeong Kim;Woo Hyun Shim;Sang Joon Kim
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1680-1689
    • /
    • 2021
  • Objective: To investigate the diagnostic yield of diffusion-weighted imaging (DWI) in patients with transient global amnesia (TGA) and identify significant parameters affecting diagnostic yield. Materials and Methods: A systematic literature search of the MEDLINE and EMBASE databases was conducted to identify studies that assessed the diagnostic yield of DWI in patients with TGA. The pooled diagnostic yield of DWI in patients with TGA was calculated using the DerSimonian-Laird random-effects model. Subgroup analyses were also performed of slice thickness, magnetic field strength, and interval between symptom onset and DWI. Results: Twenty-two original articles (1732 patients) were included. The pooled incidence of right, left, and bilateral hippocampal lesions was 37% (95% confidence interval [CI], 30-44%), 42% (95% CI, 39-46%), and 25% (95% CI, 20-30%) of all lesions, respectively. The pooled diagnostic yield of DWI in patients with TGA was 39% (95% CI, 27-52%). The Higgins I2 statistic showed significant heterogeneity (I2 = 95%). DWI with a slice thickness ≤ 3 mm showed a higher diagnostic yield than DWI with a slice thickness > 3 mm (pooled diagnostic yield: 63% [95% CI, 53-72%] vs. 26% [95% CI, 16-40%], p < 0.01). DWI performed at an interval between 24 and 96 hours after symptom onset showed a higher diagnostic yield (68% [95% CI, 57-78%], p < 0.01) than DWI performed within 24 hours (16% [95% CI, 7-34%]) or later than 96 hours (15% [95% CI, 8-26%]). There was no difference in the diagnostic yield between DWI performed using 3T vs. 1.5T (pooled diagnostic yield, 31% [95% CI, 25-38%] vs. 24% [95% CI, 14-37%], p = 0.31). Conclusion: The pooled diagnostic yield of DWI in TGA patients was 39%. DWI obtained with a slice thickness ≤ 3 mm or an interval between symptom onset and DWI of > 24 to 96 hours could increase the diagnostic yield.

영상재구성 전산화 단층촬영에서 촬영조건의 변화가 하악골 술전 임플란트 부위 평가에 미치는 영향 (Effect of Variable Scanning Protocols on the Pre-implant Site Evaluation of the Mandible in Reformatted Computed Tomography)

  • 김기덕;박창서
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.21-32
    • /
    • 1999
  • Purpose: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans. Materials and Methods: A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5. 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists. Results: On image qualities of continuity of cortical outline. trabecular bone structure and visibility of the mandibular canal and in horizontal measurement. there was no statistically significant difference among conventional and helical scans with pitches of 1.0. 1.5 and 2.0. In vertical measurement. there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. Conclusion: The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of predental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

  • PDF

3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성 (Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images)

  • 정호걸;김기덕;한승호;허경석;이제범;박혁;최성호;김종관;박창서
    • Imaging Science in Dentistry
    • /
    • 제36권2호
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF

MDCT 장치의 z-축 기하학적 선량효율에 관한 연구 (Research of z-axis geometric dose efficiency in multi-detector computed tomography)

  • 김유현;김문찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.167-175
    • /
    • 2006
  • 최근의 나선형 CT와 MDCT는 기존의 고식적 CT보다 X-선 조사시의 겹침 현상과 영상 재구성에 있어서의 보간삽입처리로 인해 보다 높은 선량을 환자에게 주게 되었다. MDCT와 나선형 CT장치가 보다 많은 의학적 정보를 제공하는 것에도 불구하고 환자가 받는 방사선 노출은 기존의 고식적 CT검사에 비해 $2{\sim}4$배 정도로 증가되고 있는 실정이므로, 그 잠재적 위험성을 아무리 강조해도 지나침이 없다. CT장치에서의 보다 많은 X-선에 관련된 자료들, 특히 선량효율적 디자인이나 X-선 조절 소프트웨어에 대한 자료들이 필요하다. 왜냐하면 CT장치의 디자인 요소는 임상적 진단에 있어서 환자선량을 성공적으로 줄일 수 있는 중요한 요소이기 때문이다. 이에 본 연구에서는 최근 급격히 확산되어 사용되고 있는 여러 단계의 MDCT의 z-축 선량효율을 측정하여 SDCT와 비교하였다. 그리고 MDCT에서 스캔 시 채택하는 focal spot size와 beam collimation, 검출기 조합 등을 비롯한 파라메터들의 변화에 따른 z-축 선량효율을 파악하여 다음과 같은 결과를 얻었다. 1. SDCT가 z-축 기하학적 선량효율이 가장 높았고, 4 슬라이스 MDCT가 가장 낮았다. MDCT 중에서는 small beam collimation 적용 시 64 MDCT가 기하학적 선량효율이 가장 높았고 16, 8, 4 슬라이스 MDCT 순이었으며, large beam collimation 적용 시에는 small focal spot에서는 8 MDCT가, large focal spot에서는 16 MDCT가 가장 높았다. 2. MDCT의 경우 large focal spot에 비해 small focal spot의 z-축 기하학적 선량효율이 최저 0.67%에서 최대 13.62%의 범위에서 높았다. 3. MDCT의 경우 small beam collimation에 비해 large beam collimation의 z-축 기하학적 선량효율이 $3.13{\sim}51.52%$의 범위에서 높았다. 4. 동일한 focal spot size와 beam collimation을 채택한 상태에서 detector combination 차이에 따른 z-축 기하학적 선량효율은 4 슬라이스 MDCT의 모든 경우와 8 슬라이스 MDCT의 large beam collimation에서 일정하였다. 하지만 8 슬라이스 MDCT의 small beam collimation과 16 슬라이스 MDCT에서는 z-축 기하학적 선량효율이 차이를 보였으며 변화의 일률성은 없었다. 5. 동일한 스캔 파라메터를 적용시 나선형 스캔과 고식적 스캔 모드의 z-축 기하학적 선량효율은 동일하였으며, pitch를 변화시키거나 영상재구성 시 슬라이스 두께와 간격을 변화시켜도 z-축 기하학적 선량효율은 변화가 없었다. 결론적으로, CT검사 시 환자가 받는 X-선 피폭선량을 줄이기 위해 연구자는 CT장치의 선량효율에 대해 각별히 주의하여야 하며, Z-축 선량효율성을 높이는 동시에 최적의 임상적 정보를 보존할 수 있는 스캔 파라메터를 선택하여야 한다.

  • PDF

내부 영상 슬라이스 구조를 이용한 관심 영역 부호화 (Region-of-Interest Coding using Sub-Picture Slice Structure)

  • 김우식
    • 방송공학회논문지
    • /
    • 제7권4호
    • /
    • pp.335-344
    • /
    • 2002
  • 관심 영역 부호화 방법은 관심 영역을 고화질로 부호화하고 배경 영역을 많이 압축함으로써 주관적 화질을 향상시키는 방법이다. 본 논문에서는 관심 영역 부호화를 효율적으로 수행할 수 있는 새로운 슬라이스 구조인 내부 영상 슬라이스 구조를 제안한다. 또한 제안한 내부 영상 슬라이스 구조를 사용할 때에 관심 영역과 배경 영역에 비트율을 할당하는 방법에 대해 다루었다. 비트율을 할당할 때 관심 영역과 배경 영역의 양자화 파라메터의 간격을 고정시켜 빠르게 양자화 파라메터를 결정하도록 하고, 특히 각 영역간에 경계가 드러나지 않도록 화질이 점차적으로 변하도록 양자화 파라메터를 설정하였다. 또한 오류가 있는 전송 환경에서 관심 영역을 배경 영역보다 오류로부터 더 많이 보호하여 주관적 화질을 향상시켰다.

Reliability of Coronary Artery Calcium Severity Assessment on Non-Electrocardiogram-Gated CT: A Meta-Analysis

  • Jin Young Kim;Young Joo Suh;Kyunghwa Han;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1034-1043
    • /
    • 2021
  • Objective: The purpose of this meta-analysis was to investigate the pooled agreements of the coronary artery calcium (CAC) severities assessed by electrocardiogram (ECG)-gated and non-ECG-gated CT and evaluate the impact of the scan parameters. Materials and Methods: PubMed, EMBASE, and the Cochrane library were systematically searched. A modified Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to evaluate the quality of the studies. Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and the correlation coefficient of the CAC scores or the weighted kappa for the categorization of the CAC severities detected by the two modalities. The heterogeneity among the studies was also assessed. Subgroup analyses were performed based on factors that could affect the measurement of the CAC score and severity: slice thickness, reconstruction kernel, and radiation dose for non-ECG-gated CT. Results: A total of 4000 patients from 16 studies were included. The pooled bias was 62.60, 95% LOA were -36.19 to 161.40, and the pooled correlation coefficient was 0.94 (95% confidence interval [CI] = 0.89-0.97) for the CAC score. The pooled weighted kappa of the CAC severity was 0.85 (95% CI = 0.79-0.91). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, the agreement between the CAC categorizations was better when the two CT examinations had reconstructions based on the same slice thickness and kernel. Conclusion: The pooled agreement of the CAC severities assessed by the ECG-gated and non-ECG-gated CT was excellent; however, it was significantly affected by scan parameters, such as slice thickness and the reconstruction kernel.

비 조영증강 흉부 CT에서 관상동맥 칼슘스코어 측정을 위한 16 cm 축상 촬영 기법의 유용성: 전향적 탐색적 연구 (Utility of the 16-cm Axial Volume Scan Technique for Coronary Artery Calcium Scoring on Non-Enhanced Chest CT: A Prospective Pilot Study)

  • 기소정;박철환;한경화;신재민;김지영;김태훈
    • 대한영상의학회지
    • /
    • 제82권6호
    • /
    • pp.1493-1504
    • /
    • 2021
  • 목적 관상동맥 칼슘스코어(coronary artery calcium score; 이하 CACS)를 측정하는 데 있어 비 조영증강 흉부 CT에서 16 cm 축상 촬영 기법의 유용성을 알아보고자 하였다. 대상과 방법 20명의 환자를 대상으로 16 cm 축상 촬영 기법을 이용한 비 조영증강 흉부 CT와 칼슘 스코어 CT를 전향적으로 시행하였다. 흉부 CT는 세 가지 절편 두께(0.625, 1.25, 2.5 mm)로 재구성하여, Agatston 방법을 통해 관상동맥 칼슘스코어를 측정하였다. 다양한 절편 두께의 비 조영증강 흉부 CT와 칼슘스코어 CT의 관상동맥 칼슘스코어를 비교하고, 단면 분석을 통해 CACS의 임상적 중요성에 대한 일치를 확인하였다. 또한 각각의 석회화 병변들을 위치와 크기로 나누어 비 조영증강 흉부 CT와 칼슘스코어 CT에서 일대일 비교를 시행하였다. 결과 2.5, 1.25, 0.625 mm 절편 두께의 흉부 CT와 칼슘스코어 CT의 CACS 상관 계수는 각각 0.9850, 0.9688, 0.9834였다. 흉부 CT와 칼슘스코어 CT 간의 CACS 차이는 0.625 mm에서 -21.4%, 1.25 mm에서 -39.4%, 2.5 mm 절편 두께에서 -76.2%였다. CACS 구간별 분석에서 절편 두께별로 16명(80%, 0.625 mm), 16명(80%, 1.25 mm), 13명(65%, 2.5 mm)의 환자가 관상 동맥 질환의 위험도 구간이 일치하였다. 관찰자 간 일치도는 모든 절편 간격에서 높게 나타났다. 세 절편 두께 중에서는 0.625 mm CT에서 석회화 병변에 대한 민감도가 가장 높았다. 결론 16 cm 축상 촬영 기법을 이용한 비 조영증강 흉부 CT에서 electrocardiogram 동기화 없이도, 0.625 mm 절편 간격에서 칼슘스코어 CT에서의 CACS와의 유사한 값을 얻을 수 있었다. 이를 통해 추가 방사선 노출 없이, 심혈관 질환 위험을 예측하는 데 도움이 될 수 있다.

정위적 방사선수술시 진단장비를 이용한 종양위치결정의 정확도 평가 (Accuracy in target localization in stereotactic radiosurgery using diagnostic machines)

  • 최동락
    • 한국의학물리학회지:의학물리
    • /
    • 제7권1호
    • /
    • pp.3-7
    • /
    • 1996
  • 정위적 방사선수술을 시행하기 위하여 CT, MR, 그리고 digital angiography 의 표적 위치결정의 정확도를 평가하였다. 특정한 지점의 위치가 이미 알려져 있는 (정밀도 : 0.lmm 이내) geometrical phantom 을 CT 혹은 MR로 scan 하였다. Scan 간격은 3mm 이었으며 FOV (Field of View)는 CT의 경우 35cm, MR 의 경우 28cm 이었다. 얻어진 영상은 GE format 의 형태로 TCP/IP를 이용하여 치료계획 컴퓨터로 전달되었다. 각 영상을 컴퓨터로 분석하여 얻은 측정된 좌표값을 이미 알고 있는 값과 비교하였다. Digital angiography 의 경우, 좌표값을 결정하기 위하여 anterior-posterior 방향과 lateral 방향의 film을 얻었으며 이 film은 film scanner를 이용하여 치료계획 컴퓨터로 전달되었다. CT 영상의 위치결정 오차는 1.2$\pm$0.5 mm이었으며 MR의 경우에는 coronal 및 sagittal 영상에 대하여 각각 평균 1.7$\pm$0.4mm, 2.1$\pm$0.7mm의 오차가 있었다. 반면에 Axial 영상의 경우에는 오차가 평균 4.7$\pm$ 0.9mm이었다. Digital angiography 의 위치결정 오차는 0.9$\pm$0.4mm이었다. CT, MR, 그리고 Angiography 등과 같은 진단장비를 이용하여 표적의 위치 및 형태를 정의하는데 있어서의 정확도는 진단 영상의 분해능 및 distortion 과 밀접한 관련을 가지고 있다. CT의 경우, 위치결정 오차는 주로 영상의 slice 간격에 따른 분해능에 의존하며 MR 영상의 경우에는 영상자체의 분해능과 더불어 head frame에 의한 distortion이 크게 작용하였다. 반면에 Digital angiography의 경우에는 fiducial marker의 distortion으로 인한 오차가 가장 크게 영향을 주었다. 본 연구의 결과는 치료계획시 PTV(Planning Target Volume)를 결정할 때 반드시 고려되어야 한다.

  • PDF