• Title/Summary/Keyword: Sleeve fiber

Search Result 35, Processing Time 0.024 seconds

A Development of Small-diameter Composite Helical Spring Structure for Reinforcement of Fiber Splice (광섬유 융착 부위 중접용 미소 직경 복합재료 스프링 구조물 개발)

  • 윤영기;정승환;이우일;이병호;윤희석
    • Composites Research
    • /
    • v.16 no.2
    • /
    • pp.26-32
    • /
    • 2003
  • Optical fibers, for splice, are stripped of their plastic coatings with a plastic stripper and cut off at the end. Therefore, stripped fibers often receive accidental damages and sustain small flaws or cracks. As a result, the breaking strength of a fiber splice made under normal conditions is reduced to about 0.4∼1 ㎏ on the average, nearly one-tenth of the fiber's strength. This makes it necessary to reinforce the splice. One of the most practical and reliable methods for optical fiber splicing is fusion splicing, comprising the steps of tripping the plastic coatings from the two fiber ends to be splice, placing the two bare fiber ends in an end-to-end position, and of fusion splicing, such as are fusion. Generally, steel bar (SB) sleeve is used to reinforce this fusion-splicing region. However, this type of sleeve has a critical defect to keep optical lose after bent by a sudden load. New type of composite spring (CS) sleeve is developed to make up for the weak points in the SB sleeve. This sleeve has an effect on restoration to the original state after eliminating the bending load. The optical spectrum analyzes results show the availability of reinforcement for the fusion splicing optical fiber using small diameter composite springs under the various loading conditions.

Integrity Evaluation of Sleeve Extension Composites Manufactured by Fiber Placement System (FPS) (Fiber Placement System(FPS)에 의해 제조된 복합재료 Sleeve Extension의 성형 건전성 평가)

  • Kong Jin-Woo;Kim Jin-Bong;Kim Tae-Wook;Ju Jin
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.254-257
    • /
    • 2004
  • Fiber placement system (FPS) carries out an advanced composites process which orients high strength reinforcing fibers in specific directions. The process includes wet winding, thermoset tape winding, thermoset prepreg placement and thermoplastic prepreg placement. FPS have the advantage of tape laying and filament winding with computer control and software. Using FPS can reduce costs, cycle times, structural weight, and handwork/rework when manufacturing composite parts. The sleeve extension is a part of the helicopter rotator systems. In this study, The sleeve extension composites were manufactured using FPS and tensile properties of this composites were characterized using universal testing machine(UTM).

  • PDF

Female Workers' Uniform Preference of the Fiber Firms (섬유업체 근로여성의 작업복 실태 및 선호연구)

  • 이옥희
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.4
    • /
    • pp.185-198
    • /
    • 1997
  • This study was initiated to research on the uniform preference uniform satisfaction and wearing of female workers' uniform of the fiber firms. Data was obtained from 361 female workers of the fiber firms in Chon Buk. And it was analyzed by frequency percent mean duncan's multiple test. The results of this study were as follows; 1) Pocket sleeve and front hem were parts of the damage. The weaving workers were mostly wore upper and under garments but most of there workers were only wore an upper garment on the basic type of uniform The older and married were small in the fitness of uniform the armhole sleeve girth sleeve length and breast girth were unfitted 2) Workers was dissatisfied to the noise and the dust in working environment. Uniform satisfaction of workers were mostly low design color and fabric were the lowest factors of uniform satisfaction. The satisfaction of material were also low the lowest factors were absorptiveness elasticity breathability. Workers wanted the fashion and light colored uniform but they prefered function activity to work and manageability on wearing rather than externals among the uniform preference.

  • PDF

Optimal connection condition study of the plastic optical fiber connector for automobiles (자동차 광 네트워크용 POF 광커넥터 최적 접속 조건 연구)

  • Jung Eun-Joo;Kim Chang-Seok;Jeong Myung-Yung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.61-68
    • /
    • 2006
  • This paper is to investigate the influence of the endface quality on the loss characteristics of a plastic optical fiber(POF) connector and the stability of new designed sleeve for in-car network service. Using the parameters of the surface roughness and applied load, insertion loss of connector is measured. Endface condition for optimizing the connection is presented by the surface roughness satisfying loss criteria and the stress for minimizing the loss, $R_{rms}=8nm$ and 19 MPa, respectively. By vibration test and dynamic loss measurement, we show the stability of the new designed sleeve.

Performance assessment of polymeric filler and composite sleeve technique for corrosion damage on large-diameter water pipes (대구경 상수도관 부식 손상부의 고분자 필러와 복합슬리브 성능 평가)

  • Ho-Min Lee;Jeong-Soo Park;Jeong-Joo Park;Cheol-Ho Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.4
    • /
    • pp.203-214
    • /
    • 2023
  • In this study, the physical properties and fracture characteristics according to the tensile load are evaluated on the materials of the polymeric filler and carbon fiber-based composite sleeve technique. The polymeric filler and the composite sleeve technique are applied to areas where the pipe body thickness is reduced due to corrosion in large-diameter water pipes. First, the tensile strength of the polymeric filler was 161.48~240.43 kgf/cm2, and the tensile strength of the polyurea polymeric filler was relatively higher than that of the epoxy. However, the tensile strength of the polymeric filler is relatively very low compared to ductile cast iron pipes(4,300 kgf/cm2<) or steel pipes(4,100 kgf/cm2). Second, the tensile strength of glass fiber, which is mainly used in composite sleeves, is 3,887.0 kgf/cm2, and that of carbon fiber is up to 5,922.5 kgf/cm2. The tensile strengths of glass and carbon fiber are higher than ductile cast iron pipe or steel pipe. Third, when reinforcing the hemispherical simulated corrosion shape of the ductile cast iron pipe and the steel pipe with a polymeric filler, there was an effect of increasing the ultimate tensile load by 1.04 to 1.06 times, but the ultimate load was 37.7 to 53.7% compared to the ductile cast iron or steel specimen without corrosion damage. It was found that the effect on the reinforcement of the corrosion damaged part was insignificant. Fourth, the composite sleeve using carbon fiber showed an ultimate load of 1.10(0.61T, 1,821.0 kgf) and 1.02(0.60T, 2,290.7 kgf) times higher than the ductile cast iron pipe(1,657.83 kgf) and steel pipe(2,236.8 kgf), respectively. When using a composite sleeve such as fiber, the corrosion damage part of large-diameter water pipes can be reinforced with same level as the original pipe, and the supply stability can be secured through accident prevention.

Temperature Compensation Technique for Steel Sleeve Packaged FBG Strain Sensor and Its Application in Structural Monitoring

  • Yun, Ying-Wei;Jang, Il-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.1-5
    • /
    • 2008
  • As bare Fiber Bragg Grating (FBG) sensors are very fragile, bare FBG without encapsulation is not properly applied in practical infrastructures directly due to the harsh environment in practical engineering. Steel sleeve packaged FBG strain sensor is widely used in civil engineering. Since FBG senses both strain and temperature simultaneously, for accurate measurement of strain, temperature compensation for FBG strain sensors is indispensable. In this paper, based on the FBG's strain and temperature sensing principles, the temperature compensation techniques for steel sleeve packaged FBG sensors are brought forward. And the experiment of concrete early-age shrinkage monitoring by dual FBG sensors is carried out to test the feasibility of the temperature compensation technique.

Fiber-Optic Sensor for Acoustic Waves (광섬유를 이용한 음파탐지기의 제작)

  • 유회준;이경목;황준암
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1983.10a
    • /
    • pp.44-47
    • /
    • 1983
  • Through intensity modulation induced by micro bending of an optical fiber, a sensor detects the pressure and frequency of acoustic wave has been implemented. Axial slots on the cylinder suface with a period of 5.5 mm induce efficient microbending of the fiber, and a rubber sleeve covering the fiber enhances the fiber. Compared with a conventional hydrophone, it has a low minimum detectable pressure and can detect acoustic wave in 100Hz - 2KHz range.

  • PDF

Tensile Behavior and Fracture Properties of Ductile Hybrid FRP Reinforcing Bar for Concrete Reinforcement (콘크리트 보강용 고연성 하이브리드 FRP 보강근의 인장 및 파괴 특성)

  • Park, Chan-Gi;Won, Jong-Pil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.1
    • /
    • pp.41-51
    • /
    • 2004
  • FRP re-bar in concrete structures could be used as a substitute of steel re-bars for that cases in which aggressive environment produce high steel corrosion, or lightweight is an important design factor, or transportation cost increase significantly with the weight of the materials. But FRP fibers have only linearly elastic stress-strain behavior; whereas, steel re-bar has linear elastic behavior up to the yield point followed by large plastic deformation and strain hardening. Thus, the current FRP re-bars are not suitable concrete reinforcement where a large amount of plastic deformation prior to collapse is required. The main objectives of this study in to evaluate the tensile behavior and the fracture mode of hybrid FRP re-bar. Fracture mode of hybrid FRP re-bar is unique. The only feature common to the failure of the hybrid FRP re-bars and the composite is the random fiber fracture and multilevel fracture of sleeve fibers, and the resin laceration behavior in both the sleeve and the core areas. Also, the result of the tensile and interlaminar shear stress test results of hybrid FRP re-bar can provide its excellent tensile strength-strain and interlaminar stress-strain behavior.

Tensile Properties and Testing Method for Glass Fiber Reinforced Polymer Reinforcing bar (GFRP Rebar의 인장특성 및 시험법에 관한 연구)

  • Park Ji-Sun;You Young-Chan;Park Young-Hwan;Choi Ki-Sun;You Young-Jun;Kim Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.172-175
    • /
    • 2004
  • This study is to investigate the tensile properties of glass fiber reinforced polymer(GFRP) reinforcing bars with various kinds of anchor systems experimentally. Three types of anchor systems were examined: resin sleeve anchor adopted by CSA Standard, metal overlay anchor by ASTM Standards and wedge anchor normally used in prestressing tendons. Also, three different types of GFRP bars with different surface deformations were tested in this study. All test procedures including specimens preparation, test apparatus and measuring devices were made according to the recommendations of CSA Standard S806-02. From the test results, it was found that the highest tensile strength of GFRP bar was developed by resin sleeve anchor, and tensile strength of GFRP bar with CSA anchor system is $10\%$ higher than that with ASTM anchor system in the case of sand-coated GFRP bar.

  • PDF

Structural Analysis and Safety Assessment of KS D 3631 Gas Pipeline Repaired by Carbon Fiber Composite Material Sleeve (탄소섬유복합재료 슬리브로 보수된 KS D 3631 배관의 구조 해석 및 안정성 평가)

  • Choi, Jongmin;Kim, Hansang;Cho, Sungmin;Lee, Seungkuk
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.96-103
    • /
    • 2016
  • Proper repair methods of damaged city gas pipeline is important factor to safely transmit gas and to reduce economical loss caused by failure of gas pipelines. Repair methods such as surfacing, type-A and type-B welding and composite sleeve method have been used to repair damaged city gas pipelines. In this paper, among repair methods, composite sleeve repair methods were conducted since they are rather simple processes and their repair quality is not sensitive to workers' ability compared with other repair methods. We discussed composite repair processes especially using carbon fiber prepregs and the experimental results.