• Title/Summary/Keyword: Slab effect

Search Result 579, Processing Time 0.028 seconds

Evaluation of the Secondary Particle Effect in Inhomogeneous Media for Proton Therapy Using Geant4 Based MC Simulation (Geant4 몬테칼로 시뮬레이션을 활용한 불균질 매질에서의 양성자의 이차입자 영향 분석)

  • Park, So-Hyun;Jung, Won-Gyun;Rah, Jeong-Eun;Park, Sung-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.311-322
    • /
    • 2010
  • In proton therapy, the analysis of secondary particles is important due to delivered dose outside the target volume and thus increased potential risk for the development of secondary cancer. The purpose of this study is to analyze the influence of secondary particles from proton beams on fluence and energy deposition in the presence of inhomogeneous material by using Geant4 simulation toolkit. The inhomogeneity was modeled with the condition that the adipose tissue, bone and lung equivalent slab with thickness of 2 cm were inserted at 30% (Plateau region) and 80% (Bragg peak region) dose points of maximum dose in Bragg curve. The energy of proton was varied with 100, 130, 160 and 190 MeV for energy dependency. The results for secondary particles were presented for the fluence and deposited energy of secondary particles at inhomogeneous condition. Our study demonstrates that the fluence of secondary particles is neither influenced insertion of inhomogeneties nor the energy of initial proton, while there is a little effect by material density. The deposited energy of secondary particles has a difference in the position placed inhomogeneous materials. In the Plateau region, deposited energy of secondary particles mostly depends on the density of inserted materials. Deposited energy in the Bragg region, in otherwise, is influenced by both density of inserted material and initial energy of proton beams. Our results suggest a possibility of prediction about the distribution of secondary particles within complex heterogeneity.

Growth Characteristics of Hydroponically Grown Melon according to Volume of Granular Rockwool and Substrates of Coir and Rockwool (입상 암면 용량과 코이어 및 암면 배지 종류에 따른 수경재배 멜론의 생육 특성)

  • Dae Ho Jung;Su Hwan Oh;Da Mi Kim;Su Oh Lee;Chul Hee Cho;Hye Won Cho;Chul Kyoo Ha;Hyun-Ah Lee
    • Journal of Bio-Environment Control
    • /
    • v.32 no.1
    • /
    • pp.72-80
    • /
    • 2023
  • Melons, a rich source of vitamins and fibers, are commonly grown in the soil. Hydroponic cultivation could improve yield and quality of melon and selection of substrate volume and the kind of substrates is important for hydroponic cultivation of melons. This study investigated the effect on melon growth according to volume of granular rockwool and substrates of coir and rockwool slab. 'Geumsegye' melon (Cucumis melo L. cv. Geumsegye) was cultivated hydroponically according to volume of granular rockwool to 1.0, 1.5, 2.0, 3.0, and 4.0 L, and was also cultivated using coir and rockwool slabs. Logistic model was applied to estimate the growth characteristics of melons such as plant height, leaf length, leaf width, and the characteristics of fruit. The growth characteristics of melons were significantly increased at 4.0 L compared to those grown of 1.0 L volume of on granular rockwool, and the results were the highest in coir and rockwool slabs. Melons grown in rockwool slabs showed the largest fruit fresh weight, fruit length, and fruit width. During hydroponic cultivation, growth characteristics of melon appropriate at the 4.0 L volume of granular rockwool, and the highest at coir and rockwool slabs. This study provides a basis for understanding the effect of root zone environment to the growth characteristics and fruit quality of non-netted melon.

Protective Immune Response of Bacterially-Derived Recombinant FaeG in Piglets

  • Yahong, Huang;Liang, Wanqi;Pan, Aihu;Zhou, Zhiai;Wang, Qiang;Huang, Cheng;Chen, Jianxiu;Zhang, Dabing
    • Journal of Microbiology
    • /
    • v.44 no.5
    • /
    • pp.548-555
    • /
    • 2006
  • FaeG is the key factor in the infection process of K88ad enterotoxigenic Escherichia coli (ETEC) fimbrial adhesin. In an attempt to determine the possibility of expressing recombinant FaeG with immunogenicity for a new safe and high-production vaccine in E. coli, we constructed the recombinant strain, BL21 (DE3+K88), which harbors an expression vector with a DNA fragment of faeG, without a signal peptide. Results of 15% SDS-polyacrylamide slab gel analysis showed that FaeG can be stably over-expressed in BL21 (DE3+K88) as inclusion bodies without FaeE. Immunoglobulin G (IgG) and M (IgM) responses in pregnant pigs, with boost injections of the purified recombinant FaeG, were detected 4 weeks later in the sera and colostrum. An in vitro villius-adhesion assay verified that the elicited antibodies in the sera of vaccinated pigs were capable of preventing the adhesion of K88ad ETEC to porcine intestinal receptors. The protective effect on the mortality rates of suckling piglets born to vaccinated mothers was also observed one week after oral challenge with the virulent ETEC strain, $C_{83907}$ (K88ad, $CT^+,\;ST^+$). The results of this study proved that the adhesin of proteinaceous bacterial fimbriae or pili could be overexpressed in engineered E. coli strains, with protective immune responses to the pathogen.

Hydrodynamic Motion and Structural Performance of Concrete Floating Structure by Length Using Numerical Analysis (수치해석을 통한 콘크리트 부유구조체 길이에 따른 운동 및 구조성능 검토)

  • Lee, Du-Ho;You, Young-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.4
    • /
    • pp.401-409
    • /
    • 2013
  • In the present study, numerical analysis was performed for hydrodynamic motion and structural performance on four different concrete floating structures, which have same cross-section but different length. The hydrodynamic analysis of floating structures is carried out using ANSYS AQWA with the different 34 wave load on regular wave period from three seconds to ten seconds in 35 m water depth. In order to evaluate structural performance of floating structures under the critical wave load which obtained from hydrodynamic analysis. The integrated analysis is also carried out through the mapping method, which can directly connect the wave-induced hydraulic pressure obtained form ANSYS AQWA to Finite Element Model in ANSYS Mechanical. As a results of this study, the hydrodynamic motion of floating structures is decreased as the length of structure increased. It means that the effect of wave-structure interaction is strongly dependent on the relationship between a wave period and a length of structure. Moreover, it is found that tension stress on bottom slab of floating structure is occurred by the critical wave load, the sectional force is not influenced by length of a structure.

Analysis of Relationship between Underground Part Environment Control and Growth and Yield of Sweet Pepper in Greenhouses as Affected by Covering Materials (피복재 종류에 따른 착색단고추 재배온실의 지하부 환경 관리와 생육 및 생산성과의 관계 분석)

  • Kim, Ho-Cheol;Park, Su-Min;Lee, Jeong-Hyun;Kang, Jong-Goo;Bae, Jong-Hyang
    • Journal of Bio-Environment Control
    • /
    • v.20 no.1
    • /
    • pp.8-13
    • /
    • 2011
  • This research was carried out to investigate relationship between underground part environment control and growth or yield of sweet pepper in greenhouse as affected by covering materials. Daily amount of applied nutrient solution for research period in the greenhouse of plasticfilm house was more 1.6 times than that in glass house. But daily absorptance rate of nutrient solution and specific electrical conductance of rockwool between two greenhouses were not different in the range of 71.3-73.3% and $4.17{\sim}4.23dS{\cdot}m^{-1}$ respectively. Leaf area of sweet pepper, in leaf growth characteristics in two greenhouses, were $123.0cm^2$/leaf (in glass house) and $119.5cm^2$/leaf (in plasticfilm house), but the another (fresh and dry weight, dry matter) were not different. But weekly yield per square meter in glass house was more 1.3 times than that in plasticfilm house as $850g{\cdot}m^{-2}$ and $650g{\cdot}m^{-2}$, respectively. Effect of slab EC and absorptance rate of nutrient solution on leaf growth characteristics and yield between two greenhouses were not different. The results show when sweet pepper is cultured in greenhouse as affected by covering materials and above ground part environment, the plant growth and yield are little affected by underground part environment.

A Study for Controlling Early-age Temperature Rise of the Concrete Pavement by Shadow Tent in Hot Weather Construction (차광막를 이용한 하절기 콘크리트포장의 초기온도 관리 방안연구)

  • Joh, Young-Oh;Kim, Hyung-Bae;Suh, Young-Chan;Ann, Sung-Soon
    • International Journal of Highway Engineering
    • /
    • v.6 no.4 s.22
    • /
    • pp.75-89
    • /
    • 2004
  • Long term performance of concrete pavement significantly depends on the given construction and environmental condition. It means that random cracks and extreme crack width due to inappropriate quality control at the early age might lead to decreasing the pavement service life. The temperature and moisture during the construction, cement and aggregate types, curing condition are major components to affect the quality of the concrete pavement at the early age. First of all, the high temperature differential, that is made by increasing air temperature and the heat of cement hydration, is known as the major contributor to severe cracks. In this study, tent covering was used for controlling temperature of the concrete slab. The field measurement data indicates that the effect of the tent covering is very significant to decrease possibilities of random crack occurrence and curling stress and enhance the long-term concrete strength. HIPERPAV(High PERformance PAVing software), a program predicting the strength and stress of an earty-age concrete pavement (72 hour after placement), is used for simulating the effects of tent covering. The HIPERPAVE results showed that the section with the tent covering has higher reliability than the section without the tent covering by 22.5%. In details, reliability is increased 72.5% (without the tent covering) to 95% (with the tent covering).

  • PDF

Static Behavior of Steel-Concrete Composite Beam with Perfobond Rib Shear Connector (Perfobond rib 전단연결재가 설치된 강.콘크리트 합성보의 정적거동)

  • Ahn, Jin Hee;Chung, Hamin;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.4
    • /
    • pp.421-432
    • /
    • 2009
  • In this study, push-out and static loading tests were conducted to evaluate the behavioral characteristics of composite beams with a perfobond rib shear connector. The shear capacity of the perfobond rib was found to be proportional to its concrete strength, which is in turn affected by the increase in the concrete end-bearing strength and concrete dowel action to resist the shear force. The relative slips of the push-out specimen, however, which was used to assess the ductility of the shear connector, increased to some extent, but it no longer increased when it reached the critical concrete strength because of the flexibility of the transverse rebar in the rib hole. The static-loading-test results revealed a crack on the concrete slab in the composite beam with a perfobond rib on the side of the rib hole and transverse rebar for the applied moment and shear force to the rib hole, depending on the static loading. The shear resistance characteristics of the perfobond rib shear connector were found to resist the shear force from the relative slip on the interface of the composite beam. Thus, the sectional effect of the shear connector to the composite beam with a perfobond rib should be considered when designing the composite beam because the behavior of the composite beam can change owing to the shear connector.

Seismic Behaviour of Exterior Joints in Post-Tensioned Flat Plate Systems (포스트 텐션 플랫 플레이트 외부 접합부의 내진 거동)

  • Han, Sang-Whan;Kee, Seong-Hoon;Kang, Tomas H.K.;Cho, Jong;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.595-602
    • /
    • 2006
  • An experimental study was conducted to investigate seismic behaviour of post-tensioned(PT) exterior slab-column connections used for the purpose to resist gravity loads only. For these, 2/3-scale, two PT post-tensioned exterior connections with two different tendon arrangement patterns and one conventional reinforced concrete(RC) exterior connection was tested under quasi-static, uni-directional reversed cyclic loading. During the lateral testing, gravity forces transferred to the column were kept constant to closely simulate a moment to shear ratio of a real building. One of the objectives of this study was to assess the necessity and/or the quantity of bottom bonded reinforcement needed to resist moment reversal which would occur under significant inelastic deformations of the adjacent lateral force resisting systems. The ACI 318 and 352 provisions for structural integrity were applied to provide the bottom reinforcement passing through the column for the specimens. Prior test results were also collected to conduct comparative studies for some design parameters such as the tendon arrangement pattern, the effect of post-tensioning forces and the use of bottom bonded reinforcement. Consequently, the impact of tendon arrangement on the seismic performance of the PT connection, that is lateral drift capacity and ductility, dissipated energy and failure mechanism, was considerable. Moreover, test results showed that the amount of bottom reinforcement specified by ACI 352. 1R-89 was sufficient for resisting positive moments arising from moment reversal under reversed cyclic loads. Shear strength of the tested specimens was more accurately predicted by the shear strength equation(ACI 318) considering the average compressive stress over the concrete($f_{pc}$) due to post-tensioning forces than that without considering $f_{pc}$.

Earthquake-Resistant Design of Cantilever Retaining-Walls with Sloped Base (기초슬래브의 밑면이 경사진 캔티레바식 옹벽의 내진설계)

  • Kim, Hong Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.87-98
    • /
    • 1990
  • The present Study dealt with the earthquake-resistant design of cantilever retaining walls supporting cohesionless soils. With design examples of three different types of cantilever retaining walls, the factors of safety against sliding were computed at various values of horizontal acceleration coefficient and compared with each other. The horizontal inertia effect due to the weights of concrete wall itself and a portion of backfill was taken into account in the analyses, and also Mononobe-Okabe pseudo-static solution method was modified to deal with various states different from limiting equilibrium state. From the analyses of safety against sliding, it was found that a cantilever retaining wall with sloped base was the most efficient type in earthquake resistant design. It was also found that by sloping the base, the width of the base slab could be reduced, resulting in the least volume of concrete, excavation and backfill as compared to the other types of walls. In the case of a cantilever retaining wall with sloped feel, the efficiency similar to that of a wall with sloped base could be expected under static loading as well as at relatively low level of earthquake loading. However, this efficiency became vanished with the increase of horizontal acceleration coefficient, since the rate of reduction in developed earth pressures on the heel became smaller. In addition, the design charts with different soil friction angles as well as with different earthquake resistant design criteria of safety factor against sliding were presented for the design of cantilever retaining walls sith sloped base.

  • PDF

Experimental Study on the Load Transfer Behavior of Steel Grid Composite Deck Joint (격자형 강합성 바닥판 이음부의 하중전달 거동에 관한 실험적 연구)

  • Shin, Hyun-Seop
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.10-21
    • /
    • 2014
  • The joint of prefabricated steel grid composite deck is composed of concrete shear key and high-tension bolts. The flexural and shear strength of the joint were experimentally evaluated only by the bending and push-out test of the joint element. In this study the lateral load transfer behavior of the joint in deck structure system is experimentally evaluated. Several decks connected by the joint are prefabricated and loaded centrically and eccentrically. In the case of centrically loaded specimens, the analysis results show that for the same loading step the rotation angle of the joint with 4 high-tension bolts is larger than the case of the joint with 9 high-tension bolts. Consequently, flexural stiffness of deck and lateral load transfer decrease in the case of specimen with 4 high-tension bolts. But, in the case of eccentrically loaded specimens, it is found that there are no significant differences in the load transfer behavior. The further analysis results about the structural behavior of the joint show that lateral load transfer can be restricted by the load bearing capacity of the joint as well as punching shear strength of the slab. Furthermore, considering that high-tension bolts in the joint didn't reach to the yielding condition until the punching shear failure, increase in the number of high-tension bolts from 4 to 9 has a greater effect on the flexural stiffness of the joint and deck system than the strength of them.