• Title/Summary/Keyword: Slab Design

Search Result 856, Processing Time 0.02 seconds

Proposing the Slab Thickness that Satisfies the Vertical Floor Vibration Criteria for Several Sizes of Flat Plate Floor System (수직진동 사용성을 고려한 플렛플레이트 두께 제안)

  • 이민정;한상환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.600-603
    • /
    • 2003
  • The floor thickness in residential buildings may not satisfy the floor vibration criteria even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. In this study provide the methods to determine the slab thickness that satisfies the vertical floor vibration criteria for several sizes of flat plate floor system. Randomness inherent in young modulus of concrete and heel drop intensity was accounted. For this purpose Monte Carlo simulation procedure was adopted.

  • PDF

The Adequate Slab Thickness Satisfied with the Vertical Floor Vibration Criteria for Several Concrete Compressive Strength (콘크리트 강도에 따른 바닥판 수직진동에 대한 적정 두께 제안)

  • 남상욱;한상환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.659-662
    • /
    • 2003
  • Recently, the floor thickness in residence may not be satisfied with the floor vibration criteria although the thickness is evaluated by the serviceability requirements in current design provisions. Thus it is necessary to develop the procedure to determine slab thickness satisfied with the floor vibration criteria. In this study, We proposed the methods to determine the slab thickness satisfied with the vertical floor vibration criteria for several concrete compressive strength of flat plate floor systems. For this purpose Monte Carlo simulation procedure was adopted and both randomness inherent in young modulus of concrete and heel drop intensity were accounted.

  • PDF

Failure Mode and Design Guideline for Reinforced Concrete Slab Strengthened Using Carbon FRP Grid (Carbon FRP Grid로 휨 보강한 철근콘크리트 슬래브의 파괴형태와 설계기준)

  • Park Sang-Yeol;Xian Cui
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.667-675
    • /
    • 2004
  • This paper presents the failure mode and strengthening design of reinforced concrete slab strengthened with Carbon Fiber Reinforced Polymer(CFRP) grid. Parameters involved in this experimental study are FRP grid reinforcement quantity, repair mortar thickness, the presence of anchor, and strengthening in compression. In this study, there are different failure types with increasing the CFRP grid strengthening reinforcement. On the low strengthening level, CFRP grid in repair mortar cover ruptures. On the moderate strengthening level, there is a debonding shear failure in the interface of carbon FRP grid because of the excessive shear deformation. On the high strengthening level, diagonal shear failure occurs. With the increasing of FRP grid reinforcement, the strengthening effect increased, but the ductility decreased. By limiting the strengthening level, it can be achieved to prevent shear failure which result in sudden loss in the resisting load capacity. CFRP rupture failure is desirable, because CFRP ruptured concrete slab keeps the same load capacity and ductility haying before strengthening even after failure. Finally, design guideline and procedure are given for strengthening of concrete slab with CFRP grid.

Development for Design Program of Prestressed Concrete Slab Bridge Using VBA(Visual Basic for Application) (VBA(Visual Basic for Application)을 이용한 프리스트레스트 콘크리트 슬래브 교량의 설계 프로그램 개발)

  • Huh, Young;Hwang, Seong-Hyun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.195-202
    • /
    • 2002
  • Generally, bridge designers must consider variable factors in design of bridge-structures. For this reason, it was difficult to make a design program till now. However, the rapid development of computers turns it into a possible one with considering complex factors and the advance of computer's language make us design programming. When we use the automatic design program including structural analysis(FEM), we can save the time and effort. Additionally, the automatic design program was generated to reduce the man' errors. Therefore, in this paper, the automatic design program of the Prestressed Concrete Slab Bridge was developed. This design program will support bridge designers with time that they can spend on a creative and efficient duty for development of design.

  • PDF

Development and Application of Lattice Shear Reinforcement for Flat Plate Slab-column Connection (래티스를 이용한 철근콘크리트 무량판 구조의 슬래브-기둥 접합부 전단보강 공법 개발)

  • Kang, Su-Min;Park, Sung-Woo;Bang, Joong-Seok;Lee, Do-Bum;Kwon, Chul-Hwan;Park, Hong-Gun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.5
    • /
    • pp.482-490
    • /
    • 2013
  • Although the flat plate system is an efficient structural type due to the simplicity of its construction, the low story height, and the various plan design, the slab-column connections are vulnerable to punching shear failure from gravity load and eccentric shear failure from lateral load. To prevent the structure collapse, various construction methods of slab-column connection reinforcement are developed but none of these satisfies all of structural performance, economics, and constructability. This paper presents the reinforcement of slab-column connection with lattice bars. The structural performance is confirmed with the interior slab-column connection tests subjected to cyclic loading, and the economic feasibility is demonstrated from the structural design under the same condition with lattice bars, stud rails, and stirrups.

Probability Based Determination of Slab Thickness Satisfying Floor Vibration Criteria (수직진동 사용성 기준을 고려한 바닥판 두께 제안)

  • Lee Min-Jung;Nam Sang-Wook;Han Sang-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.687-694
    • /
    • 2005
  • In current design practice, the thickness of the floor slab has been determined to satisfy requirement for deflection control. However, previous study shows that the floor thicknesses in residential buildings may not satisfy the floor vibration criteria, even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. This study attempts to propose slab thickness for flat plate slab systems that satisfies floor vibration criteria against occupant induced floor vibration(heel drop load). Two boundary conditions(simple and fixed support), three square flat plates(4, 6, 8m), and five concrete strength($18\~30$ MPa) are considered. Since there are large uncertainties in loading and material properties, probabilistic approach is adopted using Monte-Carlo simulation procedures.

Wheel Load Distribution of Continous Reinforced Concrete Slab Bridge (연속 철근콘크리트 슬래브 교량의 윤하중 분포폭에 관한 연구)

  • 신호상;오병환
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.4
    • /
    • pp.135-143
    • /
    • 1998
  • The wheel load distribution width for lane load is not specified in current Korea bridge design code(KD code), not like in current AASHTO and AASHTO LRFD specifications which specity it as twice of wheel load distribution width for wheel load. In this study, the wheel load distribution width in continuous reinforced concrete slab bridge is investigated. The major variables affecting the wheel load distribution of a reinforced concrete continuous slab bridge are the span length, bridge width, existence edge beam and boundary condition. From a series of comprehensive parametric study on each variable, the formula for wheel load distribution in continuous reinforced concrete slab bridge is proposed from the nonlinear regression analysis of finite element analysis results. The proposed formulas can be used efficiently in the accurate design of continuous reinforced concrete slab bridges.

A Parametric Study of Flexural Stiffness Ratio on Floor Slabs for Seismic Design of Shear Wall Structures (전단벽식 구조물의 내진설계 시 합리적인 바닥판의 휨강성비 적용에 대한 연구)

  • Oh, Soon-Taek;Lee, Dong-Jun;Em, Young-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.148-155
    • /
    • 2009
  • A remarkable discrepancy of lateral deformation of shear wall structures for seismic loads due to a rigid diaphragm assumption without floor slab modelling asks a study how much effective the slab stiffness ratio is to the lateral behaviour. Typical shear wall type 15 stories structure is selected to analysis using MIDAS-ADS2008 commercial softwares modelling three types; 1) rigid diaphragm (RD model) 2) considered out-of plane slab flexural stiffness (DB model), and 3) considered in and out of plane slab flexural stiffness (SRC model). Based on National Code of KBC2005, the Equivalent Static and Response Spectrum seismic analysis are undertaken to compare each responses of the three models. The differences of lateral responses due to the three slab stiffness ratios applied on the models are compared and discussed.

The Stability of Bridge Abutment Reinforced by Pile-slab on Soft Ground Undergoing Lateral Flow (측방유동 연약지반상 파일슬래브로 보강된 교대의 안정)

  • Hong, Won-Pyo;Song, Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.8
    • /
    • pp.13-24
    • /
    • 2006
  • A site investigation has been performed for bridge abutments constructed on soft ground, which are deformed laterally by backfill. As the result from the evaluation of lateral movement in bridge abutment, the foundation piles were not considered as the passive pile at the design stage and the period for soft ground improvement was not proper. In order to prevent lateral movement of bridge abutment, the pile slab is proposed as a countermeasure. This method can effectively prevent the lateral flow of soft ground, since the overburden surcharge due to backfill on soft ground would be effectively delivered to bedrock through the piles in soft ground. The instrumentation system is designed and installed to investigate the behavior of bridge abutment on soft ground reinforced by pile slab. The instrumentation results show that pile slab effectively resists to the lateral movement of bridge abutment due to backfill. Also, the surcharge loads due to backfill are transmitted to the bedrock through piles. It confirms that the pile slab effectively resists to the lateral movement of bridge abutment due to backfill and the applied design method is reasonable.

Large-scale cyclic test on frame-supported-transfer-slab reinforced concrete structure retrofitted by sector lead rubber dampers

  • Xin Xu;Yun Zhou;Zhang Yan Chen;Da yang Wang;Ke Jiang;Song Wang
    • Earthquakes and Structures
    • /
    • v.26 no.5
    • /
    • pp.383-400
    • /
    • 2024
  • For a conventionally repaired frame-supported-transfer-slab (FSTS) reinforced concrete (RC) structure, both the transfer slab and the beam-to-column and transfer slab-to-column joints remain vulnerable to secondary earthquakes. Aimed at improving the seismic performance of a damaged FSTS RC structure, an innovative retrofitting scheme is proposed, which adopts the sector lead rubber dampers (SLRDs) at joints after the damaged FSTS RC structure is repaired by conventional approaches. In this paper, a series of quasi-static cyclic tests was conducted on a large-scale retrofitted FSTS RC structure. The seismic performance was evaluated and the key test results, including deformation characteristics, damage pattern, hysteretic behaviour, bearing capacity and strains on key components, were reported in detail. The test results indicated that the SLRDs started to dissipate energy under the service level earthquake, and thus prevented damages on the beam-to-column and transfer slab-to-column joints during the secondary earthquakes and shifted the plastic hinges away from the beam ends. The retrofitting scheme of using SLRDs also achieved the seismic design concept of 'strong joint, weak component'. The FSTS RC structure retrofitted by the SLRDs could recover more than 85% bearing capacity of its undamaged counterpart. The hysteresis curves were featured by the inverse "S" shape, indicating good bearing capacity and hysteresis performance. The deformation capacity of the damaged FSTS RC structure retrofitted by the SLRDs met the corresponding codified requirements for the case of the maximum considered earthquake, as set out in the Chinese seismic design code. The stability of the FSTS RC structure retrofitted by the SLRDs, which was revealed by the developed stains of the RC frame and transfer slab, was improved compared with the undamaged FSTS RC structure.