CNC 공작기계용 온라인 실시간 위치오차 보정시스템의 개발 (Development of Online Realtime Positioning Error Compensation System for CNC Machine Tools)

  • 정재일;김종원;남원우;이상조
    • 한국정밀공학회지
    • /
    • 제16권10호
    • /
    • pp.45-52
    • /
    • 1999
  • The online realtime positioning error compensation system 'SKY-PACS' is developed to correct geometric errors, thermal errors and tool deflection errors induced by cutting forces on the vertical machining center. 'SKY-PACS' communicates position commands and position compensation signals with the CNC controller at 100Hz, which is CNC control frequency. So the compensation procedure can be applied during axis movement. Using 'SKY-PACS', Maximum 1 axis positioning accuracy was corrected from 5{\mu}m$ to 2{\mu}m$and the squareness error of X-Y table was corrected from 51{\mu}m$/m to below 4{\mu}m$/m. The error compensation under the cutting condition is carried out by ISO10791-7. And the measurement of test-pieces shows that the roundness is corrected rom 8{\mu}m$ to below 5{\mu}m$.

  • PDF

시뮬레이션 분석기법을 이용한 주거용 건물의 공간별 채광성능 연구 (Space study on Lighting Performance For Residential Buildings By using Simulation Analysis)

  • 임태섭;임정희;김병선
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.97-104
    • /
    • 2013
  • This proposed simulation-based design study is based on the design of residential high-rise buildings in South-Korea. the purpose of this study is to evaluate the amount of daylighting performance passing through building glazing according to sky conditions, orientation of windows and each space of Apartment buildings. The clear sky includes sunshine and is intense and brighter at the horizon than at the zenith, except in the area around the sun. Daylight received within a building is directly dependent upon the sun's position and the atmospheric conditions. Orientation of the building generally used to refer to solar orientation which is the siting of building with respect to solar access. Although any building will have different orientations for its different sides, the orientation can refer to a particular room, or to the most important facade of the building. north-facing windows receive twice the winter sun than east and west facing windows, allowing light and warmth into the home. They can be easily shaded from the high summer sun to help keep the house cool. Ideally, the glazing area should be between 10-25% of the floor area of the room. This paper was calculated by a Desktop Radiance program. The space dimensions were based on a unit module of real constructed apartment having divided into five sections such as living room, room1, room2, room3 and kitchen.

거울형 태양광 채광시스템의 실제 건축물 적용에 따른 실내주광조도 평가 (Indoor Illuminance Evaluation on a Mirror Sunlighting System Applied to the Apartments under Real Sky Condition)

  • 정주희;김정태
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.137-145
    • /
    • 2010
  • Active sunlighting systems have been applied to deliver sunlight into the indoor space where natural light is insufficient, mainly because of the congested high-rise buildings in urban areas. Among various active sunlighting systems, a mirror sunlighting system which is simple structure and economically reasonable has been widely used in different types of spaces such as underground, north facing place and atrium. This study was to evaluate the mirror sunlighting systems, which were consisted of the first mirror of $3.5m{\times}2.5m$, the eight sets of the second mirrors of $1.0m{\times}1.25m$ and a sun tracker. Ten sets of the systems were installed for 40 apartment living rooms, the configuration of $3.5m(W){\times}4.0m(D){\times}2.5m(H)$ where sunlighting were not possible due to high retaining walls located in the front of the living rooms. The 45 HOBO data logger sensors for the indoor illuminance were equipped and 2 Li-cor photometers for outdoor illuminance. Both indoor and outdoor horizontal illuminances were monitored every second from 9am to 3pm on 17 January 2010 under clear sky condition. The results showed that the indoor illuminance of installed mirror sunlighting system was significant relationship with outdoor illuminance and increased the indoor illuminance level by 4.2 times on the whole floor space, by 8 times on the sun patch space of 6m2 and even by 2 times on the no sun patch space. In addition, the luminous conditions of the living room under real sky conditions met the KS recommendation for difficult task (600-1000-1500 lux) such as sewing and reading on whole floor space and sun patch space. It was proved that the benefits of mirror sunlighting systems included an effective technology for penetrating daylight into indoors where sunlighting was not possible and improving occupants' satisfaction and health, and contributing to energy saving in apartments during daytime.

해남 라디오미터로부터 산출된 가강수량과 구름물량의 분포특성 (Characteristics of Precipitable Water Vapor and Liquid Water Path Retrieved from a Ground-based Microwave Radiometric Profiler at Haenam NCIO)

  • 원혜영;김연희;장동언
    • 대기
    • /
    • 제20권1호
    • /
    • pp.1-12
    • /
    • 2010
  • Temporal distributions and characteristics of PWV (Precipitable Water Vapor) and LWP (Liquid Water Path) are investigated by using the microwave radiometric profiler at Haenam NCIO from 1 August 2007 to 31 July 2008. Temporal variations of PWV are closely connected with the thermal response of water vapor in atmosphere. The variations of LWP are characterized by the rainfall variation being basically attributable to the heavy rain-bearing clouds. The frequency distributions of PWV and LWP according to the four sky conditions ('clear', 'lightly cloudy', 'cloudy', and 'deeply cloudy') by total cloud amount at Wando Observatory corresponds with a change of slope in cumulative distribution function for PWV and LWP. There results implies that the classification of sky condition can be applied by using the distribution of PWV and LWP from microwave radiometric profiler.

채광성능 평가용 시뮬레이션 프로그램의 비교분석 (A Comparative Evaluation of Daylighting Performance Software : Lumen-Micro, Adeline and Lightscape)

  • 김정태;정유근;문기훈
    • 한국태양에너지학회 논문집
    • /
    • 제23권1호
    • /
    • pp.48-56
    • /
    • 2003
  • Three of the leading computer daylighting simulation programs are compared with physical modeling techniques as a means of predicting daylighting performance of interior spaces. Lumen-Micro, Adeline and Lightscape are compared with physical model experiments under clear sky conditions. The comparative evaluations are conducted on analysis of daylight illuminance ratio(%) depending on model types. The estimated average errors are analyzed on 9.4% in Lumen-Micro, 6.3% in Adeline and 3.4% in Lightscape. Therefore, it is proved that three programs are useful for evaluating daylighting performance in our clear sky condition.

천체의 광역 관측을 위한 CCD 카메라 개발 (DEVELOPMENT OF CCD CAMERA FOR OBSERVING WIDE FIELDS)

  • 유영삼;박수종;김민진;이성호;변용익;천무영;한원용
    • 천문학논총
    • /
    • 제16권1호
    • /
    • pp.43-47
    • /
    • 2001
  • We developed a CCD camera that can observe wide fields on the sky. We tested the field of views using various lenses. For cooling the CCD chip, we used a thermoelectric cooling device and tested the cooling efficiency. This camera will continuously observe a part of the sky. The data from the camera will be used to decide the current weather condition by the real-time star counting program (SCount) which will be developed later.

  • PDF

비 투과면 복사 냉각에 대한 복사 물성의 영향 예측 (Simulation of Radiative Property Effects on Radiant Cooling of Opaque Surface)

  • 변기홍
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.32-38
    • /
    • 2009
  • The effects of surface radiative properties on the radiant cooling of opaque surfaces under clear sky condition are studied. Two types of surfaces, one gray and the other selective, are compared. For the nighttime cooling, black surface gives the lowest plate temperature and on the other hand the ideal selective surface gives the highest temperature. The reverse is true when there is an insolation. Equivalent radiative heat transfer coefficient of radiant cooling without convection is about $1{\sim}7\;W/m^2-K$ for the range of values studied. The surface with black within the $6{\sim}13\;{\mu}m$ band else zero emissivity could be regarded as a black surface for the nighttime radiant cooling purposes. However, lower band limit of $4\;{\mu}m$ is preferred to $6\;{\mu}m$ for small insolation situations.

관개계획을 위한 일기예보의 신뢰성과 활용성 (Reliability and Applicability of Weather Forecasts for Irrigation Scheduling)

  • 이남호
    • 한국농공학회지
    • /
    • 제41권6호
    • /
    • pp.25-32
    • /
    • 1999
  • The purpose of this study is to analyse the accuracy of weather forecasts of temperature, precipitation probability , and sky condition and to evaluate the applicability of weather forecasts for the estimation of potential evapotranspiration for irrigation scheduling. Five weather station s were selected to compare forecasted and measured climatcal data. The error between forecasted and measured temperature was calculated and discussed. The accuracy of temperature forecast using relative frequency of the error was calculated . The temperature forecasting showed considerably high accuracy. Average sunshine hours for forecasted sky conditions were calculated and showed reasonable quality. From the reliability graphs, the forecasting precipation probabililty was reliable. Potential evapotranspirations were calculated and compared using forecast and measured temperatures. The weather forecast is considered usable for irrigation scheculing.

  • PDF

광센서 조광제어시스템의 소비전력 평가 (Evaluation of Energy Consumptions in Daylight Responsive Dimming Systems)

  • 이순지;최안섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.195-199
    • /
    • 2006
  • This study aims to measure amount of the reduction ratio of energy consumptions by the daylight responsive dimming systems, which uses daylighting and electric lighting. The results of this study show that the reduction ratio of electric power is better 'clear sky' by sky condition and 'window side of room' by zoning. When calculating reduction ratio of energy consumptions with used times in real office space, it tells that the result of real office was higher ratio than that of experimental space. For this study which presents efficient use of daylight in office environment, it will be basis of improving energy performance.