• 제목/요약/키워드: Sky condition

검색결과 130건 처리시간 0.03초

소규모 사무실공간에서 주광조건에 따른 대비효과 및 조명에너지 절약예측 (Prediction of Contrast and Lighting Energy Saivings in a Small Office Space according to Daylight Conditions)

  • 김수영
    • 한국태양에너지학회 논문집
    • /
    • 제24권4호
    • /
    • pp.35-43
    • /
    • 2004
  • Illuminance and luminous levels in a small office space due to daylight were calculated to analyze the impact of daylight on contrast and lighting energy savings. Computer simulations were performed for four blind conditions under a clear sky condition. The blind conditions significantly impacted the illuminance an4 luminance level. Visual performance scores were calculated according to the transfer function that uses absolute contrast between target and background surface. The blind condition that had 45 tilted angle toward ground provided good contrast and performance scores. Using a control algorithm of an automated daylight dimming control system lighting energy sayings were predicted. For all blind conditions minimum lighting energy was consumed.

A Daylight Calculation Method for a Louver System Under the Uniform Sky Condition

  • Kim, Kang-Soo;Hwang, Young-Seok
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.41-46
    • /
    • 1999
  • The configuration factors in the flux transfer method are applied to calculate daylight factors reaching a station point. To analyze the window equipped with a louver system, geometrical correlation is used for the length shielded by the louver. The space in front of a window is assumed to be an imaginary outdoor space for calculating the luminance of the louver system. The data calculated from this study are compared with SUPERLlTE simulation data and the scale model data. Scale model data are collected on the roof of the Engineering building at Korea University in Seoul under the uniform sky condition.

  • PDF

자연채광 성능의 가시화도구로서 LIGHTSCAPE의 유용성 평가 (Validity of LIGHTSCAPE As a Visualization Tool for Daylighting Performance)

  • 문기훈;김정태
    • 한국실내디자인학회논문집
    • /
    • 제37호
    • /
    • pp.110-118
    • /
    • 2003
  • Computer simulation is one of the most useful techniques to predict daylighting performance and present visual image. In architectural and interior design practice, the Lightscape is commonly used often to produce persuasive images rather than physically accurate results. Therefore, this study is to validity the Lightscape as daylighting evaluation tool, in particularly performance and realistically visualization. For the purpose, an evaluation test model (12.0m$\times$7.2m$\times$3.0m) of side lighting window with lightshelf was selected. A 1:6 scale plywood physical model was made. Under clear sky condition, illuminance of 84 Interior point were measured. Lightscape was run on a 750 MHz Pentium PC running Windows 2000 under the same sky condition. And a photography image was compared to rendering image. The physical results of interior illuminance were within 8% between the scale model and Lightscape simulation. There were no differences between the photograph image and rendering image by Lightscape in the sight. Lightscape as visualization tool for daylighting performance was validated.

기상청 동네예보의 영농활용도 증진을 위한 방안: IV. '하늘상태'를 이용한 일조시간 및 일 적산 일사량 상세화 (Improving the Usage of the Korea Meteorological Administration's Digital Forecasts in Agriculture: IV. Estimation of Daily Sunshine Duration and Solar Radiation Based on 'Sky Condition' Product)

  • 김수옥;윤진일
    • 한국농림기상학회지
    • /
    • 제17권4호
    • /
    • pp.281-289
    • /
    • 2015
  • 일조시간 및 일사량은 작물생육에 중요한 기상요소이지만 기상청 동네예보 항목에 없기 때문에 3시간 간격 '하늘상태'를 활용하여 일조시간 및 수평면 일사량을 추정하는 방법을 고안하였다. 기상청 동네예보의 3시간 간격 '하늘상태' 자료를 수집하고 전국 22개 일사관측 기상대의 동시간대 실측 운량과 비교하여 '하늘상태'의 4단계 격자값 '맑음(1)', '구름조금(2)', '구름많음(3)', '흐림(4)'을 0부터 10까지의 운량으로 변환하였다. 22개 일사관측 기상대의 일 평균운량 0인 날에 대하여 일조율을 비교하여 관측여건이 가장 좋은 3개 지점을 선정하였다. 선정된 지점의 3년치 운량과 일조시간 실측자료로부터 운량-일조시간 추정식을 도출하였으며, 이 식에 의해 추정된 일조시간값으로 Angstrom-Prescott 모형을 구동하여 수평면 일사량을 산출하였다. '하늘상태' 기반으로 추정된 일조시간 및 일사량을 3 지점에서 2년간 실측자료와 비교한 결과 RMSE 기준 일조시간 추정오차는 1.5~1.7 시간, 일사량 추정오차는 $2.5{\sim}3.0MJ\;m^{-2}\;day^{-1}$ 이었다.

축소모형을 이용한 광선반의 시환경 특성 평가 연구 (Visual Performance Evaluation Study of a Scaled Light-Shelf Model)

  • 조일식;김병수;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.

천공상태에 따른 박막 BIPV 창호의 온도 및 발전특성 실측연구 (A Study on Optimum of Performance Objectives of Passive House with Load Reduction elements)

  • 김빛나;윤종호;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.171-176
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temporature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish mornitoring system and analysis the date from the mornitoring system to evaluate the performance of PV windows that has thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

  • PDF

지하주차장 빛환경 개선을 위한 광파이프 시스템의 채광성능 평가에 관한 연구 (Performance Assessment of Light Pipe System for the Advanced Luminous Environment of the Underground Parking Lot)

  • 신주영;황태연;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.25-33
    • /
    • 2010
  • Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.