• 제목/요약/키워드: Skull image

검색결과 144건 처리시간 0.024초

파노라마 X선사진에서의 상악동상 (THE IMAGE OF THE MAXILLARY SINUSES IN THE PANORAMIC RADIOGRAPH)

  • 최순철
    • 치과방사선
    • /
    • 제21권2호
    • /
    • pp.157-163
    • /
    • 1991
  • The author has evaluated the panoramic image of the maxillary sinus according to the skull position. The lead foils were attached to the five walls of the maxillary sinus and the inferior turbinate individually. The skull was located in three positions; standard position, 20㎜ forward position and chin-down position. The obtained results were as follows: 1. In standard position, the medial wall was superimposed upon most of the panoramic antral image. The anterior wall and the posterolateral wall were superimposed upon the medial half and the lateral third respectively. 2. In forward position, the width of the panoramic antral image was diminished generally. The anterior wall was superimposed upon most of the panoramic antral image and the posterolateral wall appeared narrowly at the most lateral portion of the panoramic antral image. 3. In chin-down position, there was no significant difference in comparison to the standard position. 4. Inferior turbinate was not superimposed upon the panoramic antral image.

  • PDF

두개골 영상합성에 의한 개인감정시스템 연구-II (A Study on the Individual Recognition with Skull Image Composition)

  • 송현교;이양원;강민구
    • 한국정보통신학회논문지
    • /
    • 제2권1호
    • /
    • pp.3-10
    • /
    • 1998
  • 슈퍼임포즈는 개인식별 방법으로 신원 미상의 두개골의 발견 시, 두개골의 사진과 용의자 생전 사진의 동일 비율로 확대, 축소 후 두 영상을 중첩하므로서 동일인 여부를 비교, 판별하는 기법으로 삼풍백화점 붕괴사고와 Quam KAL기 추락사고와 같이 대형사건에서의 개인식별은 매우 중요한 문제이다 기존의 방법은 렌즈와 거울 및 사진기술에 의존하는 수작업으로 2주정도의 시간이 소요되는 반면 본 연구의 결과로 컴퓨터 영상처리 기술과 주변기기의 활용을 이용하여 슈퍼임포즈 영상의 실시간 처리와 보다 다양하고 자세한 영상처리 정보에 의한 상세한 슈퍼임포즈 영상정보를 얻을 수 있다. 본 연구는 비디오 카메라로 입력한 두개골 영상과 스캐너로 입력한 생전 사진의 중첩을 위한 영상시스템의 구축과 영상처리 기법을 응용한 다양한 응용 프로그램을 개발하였다. 슈퍼임포즈의 영상처리 기법으로는 두개골 및 생전 사진의 윤곽선 추출, 중첩점 조정, 상,하,좌,우 각도조정, 윤곽선보정, Hue 조정, 히스토그램 조정 등 다양한 영상처리 기법을 응용하고, 보다 자세한 감정문 형식을 도입하였다. 또한, 본 슈퍼임포즈 영상시스템은 국립과학수사연구소의 슈퍼임포즈 영상자료의 처리기술 및 축적 기술의 발전으로, 두개골 영상과 생전 사진을 이용한 생전의 3차원 영상의 복원 연구도 가능하리라 사려된다.

  • PDF

두부위치에 따른 안면골의 파노라마방사선사진상 (PANORAMIC RADIOGRAPH OF THE FACIAL BONES ACCORDING TO HEAD POSITION)

  • 최순철
    • 치과방사선
    • /
    • 제19권1호
    • /
    • pp.25-29
    • /
    • 1989
  • The author has evaluated the panoramic image clarity of the midfacial anatomic structures in dry skull according to the skull position. The radiopaque markers were attached to the anatomic structures: infraorbial rim, upper and lower borders of zygomatic arch, pterygomaxillary fissure, lateral pterygoid plate, pyriform aperture of nasal cavity, lateral wall of maxilla, orbital floor, infraorbital foramen, and nasal floor. Position of the skull were divided into four groups. standard, 25mm forward, chin-down, chin-up position. The results were as follows: 1. The pyriform aperture of nasal cavity, lateral wall of the maxilla, orbital floor, infraorbital foramen and nasal floor did net cast any discernible image. 2. Nearly all images of midfacial structures were blurred in the chin-up position. 3. The forward position provided good visualization of the maxillary sinus. 4. The chin-down position provided good visualization of the zygomatic arch, pterygomaxillary fissue, and lateral pterygoid plate.

  • PDF

Haas 촬영법에서 선예한 영상 획득을 위한 연구 (A Study to Acquire Sharp Images in the Haas(Skull PA Axial Projection))

  • 안준호;한재복;송종남;김인수
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.319-325
    • /
    • 2022
  • 본 연구는 머리뼈 후전축방향 촬영(Haas)에서 선예한 영상을 얻어 진단하고자 Skull -Phantom을 이용하여 자세 각도를 변경하여 영상을 획득한 후 대학병원 영상의학과에 근무한 방사선사 5명에게 주관적 영상평가한 결과 머리를 엎드린자세에서 머리 뒤쪽의 뒤통수점에서 4 cm 아래로 내리고 머리쪽을 향하여 25° 입사하여 촬영시에 뒤통수뼈와 큰구멍내에 투영된 안장등, 뒤침대돌기등 영상평가 점수가 20점으로 높았으며, 뒤통수점에서 아래로 8 cm 내려서 머리쪽으로 30° 입사 시 바위모뿔대칭의 음영, 바위능선과 시상봉합, 시웃자봉합 등 19점으로 높은 영상평가를 받았다. 또한, 점수 유의성을 검증하였으며, Cronbach Alpha 값이 0.789 신뢰도가 좋음을 평가 받았다. 영상의 관심영역(ROI)을 설정하여 신호대잡음비(SNR)를 산출한 결과 머리 뒤쪽 뒤통수점에서 4 cm 아래로 내리고 머리쪽으로 25° 입사 시 5.957로 가장 높으며, 뒤통수점에서 아래로 8 cm 내려서 입사 시는 머리쪽으로 30° 기울여 촬영하였을 때 6.430으로 가장 높았다. 연구결과에 의하면 머리 후전축방향 촬영시 뒤통수뼈와 안장, 뒤침대돌기의 선예한 영상을 얻기 위해서는 뒤통수점에서 아래로 4 cm 에서 머리쪽으로 25° 입사하여 촬영하고 바위모뿔대칭의 음영과 바위능선과 시상봉합, 시웃자봉합의 선예한 영상을 얻기 위해서는 뒤통수점에서 아래로 8 cm 내려서 머리쪽으로 30° 기울여 촬영한다면 임상에서 활용에 도움이 있으리라 사료된다.

3D Printed Titanium Implant for the Skull Reconstruction: A Preliminary Case Study

  • Choi, Jong-Woo;Ahn, Jae-Sung
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권2호
    • /
    • pp.99-102
    • /
    • 2014
  • The skull defect can be made after the trauma, oncologic problems or neurosurgery. The skull reconstruction has been the challenging issue in craniofacial fields for a long time. So far the skull reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for skull reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile various types of allogenic and alloplastic materials have been also used. However, skull reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original skull anatomy as possible using the 3D printed titanium implant, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we fabricated Titanium implant to reconstruct three-dimensional orbital structure in advance, using the 3D printer. This prefabricated Titanium-implant was then inserted onto the defected skull and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

웨이브렛 변환을 이용한 Skull & Panorama 영상 인식과 특징 추출에 관한 연구 (A Study on Skull & panorama Image recognition of feature exctraction using the Wavele Transform)

  • 문일남;김장형
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.113-117
    • /
    • 2003
  • 본 논문에서는 병원에서의 PACS(Picture Archiving and Communications System)의 필요성을 갖고 있으나 경제적인 문제로 인하여 향후 PACS를 도입이 어려움이 있는 병원에서는 고가의 장비를 구입을 할 수 없으므로 가중치 메디안 필터를 이용하여 전처리 필터링을 거친 영상을 가지고 웨이브렛 분해와 웨이브렛 영역에서 처리된 영상을 역변환시켜 복원한 뒤에 명암의 개선을 위해 히스토그램 평활화(Histogram equalization)을 적용하여 영상 품질을 향상하여 이를 의료영상에 적용하여 특징 추출하였다. 이는 차후, 의료영상의 진단 및 관찰에 적용시 보다 더 효율적인 시스템 적용을 목적으로 하였다.

  • PDF

MDCT 영상과 ADINA 유한요소해석 프로그램을 활용한 두개골 손상 평가에 관한 연구 (A Study on the Skull Injury Using MDCT image and ADINA F.E.M. Program)

  • 김의수;김종혁;양경무
    • 한국안전학회지
    • /
    • 제28권1호
    • /
    • pp.1-5
    • /
    • 2013
  • In this paper, the finite element analysis using ADINA has performed to investigate an accident that a man's head was damaged by the falling object. The simulation condition has defined by the point of forensic medicine view and the CCTV image analysis. From the CCTV image analysis, we expected that the sphere diameter of object is 15cm and object color is white. Assuming the falling mass is the ice mass, the results of the ADINA simulation show that a man's head can be broken by the falling ice mass.

표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가 (Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR)

  • 김상태;한범희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.173-178
    • /
    • 2010
  • 방사선 일반촬영은 크게 두 가지 유형으로 구분할 수 있는데 디지털 영상 시스템인 CR(Computed Radiography)과 DR(Digital Radiography)이 주로 활용되고 있다. 이 둘의 차이는 선량과 영상의 질 관점에서 정의할 수 있다. 본 연구에는 피부입사선량(Entrance Skin Dose, ESD)의 관점에서 환자에게 투여된 선량을 계산하고 비교하여 CR과 DR 간의 선량 차이를 연구하기 위해 8가지의 표준 영상의학적 검사(Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP)가 고려되었다. 영상화질에 대한 평가는 진단방사선학적 영상을 위한 화질 기준에 부합하는지를 보증하기 위해 영상의학과 전문의에 의해 시행되었다. DR의 ESD는 CR의 ESD보다 낮다는 것이 확인되었다. 방사선 촬영을 담당한 방사선사가 동일인 이었고 CR과 DR의 영상 화질이 유사하거나 DR에서 조금 더 우수했기 때문에 본 연구는 고려된 검사 내에서 DR이 CR보다 선량 절감 차원에서 볼 때 더 우수한 기기라는 것을 보여준다.

머리뼈 전-후 축 방향검사 시 Tube 방향설정에 따른 표면선량과 영상분석에 관한 연구 (A Study on the Comparative Analysis of Images and Doses According to Tube Orientation During Anterior-Posterior Axial Projection Examination of the Skull)

  • 정성훈;유제현;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.301-306
    • /
    • 2021
  • The skull has peripheral organs such as the crystalline lens and thyroid gland, which are highly radiosensitive, but the examination is performed without considering the uneven dose distribution due to the heel effect at the time of the current Skull Town's examination. However, no studies have been conducted on the exposure dose of surrounding organ tissues due to the difference in image density due to the heel effect and the non-uniformity of the dose. Using the cathode (-) and anode (+) set on the Tube to measure the scattered radiation along the Tube direction as a guide, change 30° and 37° in the cathode direction and 30° and 37° in the anode direction. It was given and investigated 5 times to obtain scattered radiation. image measurements were SNR, PSNR, RMSE, and MAE. Measurement results Measurement results of surrounding organ doses when the Tube direction was 30° and 37° The dose was low when the direction was cathodic in all organs (p<0.000). Both cathodes were higher in the image measurements(p<0.04). Continuous research may be needed for diagnostically valuable imaging and minimization of patient exposure dose.

두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향 (Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images)

  • 정호걸;김기덕;박혁;김동욱;정해조;김희중;유선국;김용욱;박창서
    • Imaging Science in Dentistry
    • /
    • 제34권3호
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF