• Title/Summary/Keyword: Skull base

Search Result 179, Processing Time 0.025 seconds

Craniofacial morphologic alteration induced by bone-targeted mutants of FGFR2 causing Apert and Crouzon syndrome (어퍼트 및 크루즌 증후군을 유발하는 골조직 특이성 FGFR2 돌연변이에 의한 두개안면 형태의 변화)

  • Lee, Kee-Joon;Nah, Hyun-Duck;Tjoa, Stephen T. J.;Park, Young-Chel;Baik, Hyoung-Seon;Yun, Tae-Min;Song, Jin-Wook
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.284-294
    • /
    • 2006
  • Objective: Activating mutations in the fibroblast growth factor receptor-2 (FGFR2) have been shown to cause syndromic craniosynostosis such as Apert and Crouzon syndromes. The purpose of this pilot study was to investigate the resultant phenotypes induced by the two distinctive bone-targeted gene constructs of FGFR2, Pro253Arg and Cys278Phe, corresponding to human Apert and Crouzon syndromes respectively. Methods: Wild type and a transgenic mouse model with normal FGFR2 were used as controls to examine the validity of the microinjection. Micro-CT and morphometric analysis on the skull revealed the following results. Results: Both Apert and Crouzon mutants of FGFR2 induced fusion of calvarial sutures and anteroposteriorly constricted facial dimension, with anterior crossbite present only in Apert mice. Apert mice differed from Crouzon mice and transgenic mice with normal FGFR2 in the anterior cranial base flexure and calvarial flexure angle which implies a possible difference in the pathogenesis of the two mutations. In contrast, the transgenic mice with normal FGFR2 displayed normal craniofacial phenotype. Conclusion: Apert and Crouzon mutations appear to lead to genotype-specific phenotypes, possibly causing the distinctive sites and sequence of synostosis in the calvaria and cranial base. The exact function of the altered FGFR2 at each suture needs further investigation.

Evaluation of the Neural Fiber Tractography Associated with Aging in the Normal Corpus Callosum Using the Diffusion Tensor Imaging (DTI) (확산텐서영상(Diffusion Tensor Imaging)을 이용한 정상 뇌량에서의 연령대별 신경섬유로의 변화)

  • Im, In-Chul;Goo, Eun-Hoe;Lee, Jae-Seung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.189-194
    • /
    • 2011
  • This study used magnetic resonance diffusion tensor imaging (DTI) to quantitatively analyze the neural fiber tractography according to the age of normal corpus callosum and to evaluate of usefulness. The research was intended for the applicants of 60 persons that was in a good state of health with not brain or other disease. The test parameters were TR: 6650 ms, TE: 66 ms, FA: $90^{\circ}$, NEX: 2, thickness: 2 mm, no gap, FOV: 220 mm, b-value: $800s/mm^2$, sense factor: 2, acquisition matrix size: $2{\times}2{\times}2mm^3$, and the test time was 3 minutes 46 seconds. The evaluation method was constructed the color-cored FA map include to the skull vertex from the skull base in scan range. We set up the five ROI of corpus callosum of genu, anterior-mid body, posterior-mid body, isthmus, and splenium, tracking, respectively, and to quantitatively measured the length of neural fiber. As a result, the length of neural fiber, for the corpus callosum of genu was 20's: $61.8{\pm}6.8$, 30's: $63.9{\pm}3.8$, 40's: $65.5{\pm}6.4$, 50's: $57.8{\pm}6.0$, 60's: $58.9{\pm}4.5$, more than 70's: $54.1{\pm}8.1mm$, for the anterior-mid body was 20's: $54.8{\pm}8.8$, 30's: $58.5{\pm}7.9$, 40's: $54.8{\pm}7.8$, 50's: $56.1{\pm}10.2$, 60's: $48.5{\pm}6.2$, more than 70's: $48.6{\pm}8.3mm$, for the posterior-mid body was 20's: $72.7{\pm}9.1$, 30's: $61.6{\pm}9.1$, 40's: $60.9{\pm}10.5$, 50's: $61.4{\pm}11.7$, 60's: $54.9{\pm}10.0$, more than 70's: $53.1{\pm}10.5mm$, for the isthmus was 20's: $71.5{\pm}17.4$, 30's: $74.1{\pm}14.9$, 40's: $73.6{\pm}14.2$, 50's: $66.3{\pm}12.9$, 60's: $56.5{\pm}11.2$, more than 70's: $56.8{\pm}11.3mm$, and for the splenium was 20's: $82.6{\pm}6.8$, 30's: $86.9{\pm}6.4$, 40's: $83.1{\pm}7.1$, 50's: $81.5{\pm}7.4$, 60's: $78.6{\pm}6.0$, more than 70's: $80.55{\pm}8.6mm$. The length of neural fiber for normal corpus callosum were statistically significant in the genu(P=0.001), posterior-mid body(P=0.009), and istumus(P=0.012) of corpus callosum. In order of age, the length of neural fiber increased from 30s to 40s, as one grows older tended to decrease. For this reason, the nerve cells of brain could be confirmed through the neural fiber tractography to progress actively in middle age.

$^{18}F$-FDG Colonic Uptake by Oral Anti-Diabetic Drugs Including Metfomin in PET/CT Scan (PET/CT 검사에서 Metformin 성분의 항 당뇨약제에 의한 대장에서의 $^{18}F$-FDG 섭취에 관한 연구)

  • Kim, Sang-Gyu;Park, Hoon-Hee;Kim, Jung-Yul;Bahn, Young-Kag;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.50-54
    • /
    • 2010
  • Purpose: The uptake of $^{18}F$-FDG is often observed in normal cell of colon to patients who have non-insulin-dependent diabetes mellitus and had taken anti-diabetic drugs including Metformin in PET/CT scan. In this study, the region of colon was compared between the patients who took anti-diabetic drugs including Metfomin and other patients who took the other anti-diabetic drugs through SUV measurements. Materials and Methods: A hundred eighty patients were studied. 120 patients who have non-insulin-dependent diabetes mellitus (Including Metformin: 60, Excluding Metformin: 60) and 60 patients as a control group were composed. The patient fasted at least 6 hours before receiving an intravenous injection of 370-592 MBq (10-16 mCi) of $^{18}F$-FDG. Scanning from the base of the skull though the mid thigh was performed using the Discovery STe PET/CT Equipment (GE Healthcare, Milwaukee, WI, USA). The highest uptake region was measured SUV among ascending, transverse and descending colon. Results: The values of patients who took the anti-diabetic drugs including Metformin were $6.16{\pm}3.64$ g/mL, $4.41{\pm}2.94$ g/mL, and $5.46{\pm}2.44$ g/mL. The patients who took the anti-diabetic drugs which does not have Metformin were $3.05{\pm}1.39$ g/mL, $2.08{\pm}0.97$ g/mL and $3.15{\pm}1.85$ g/mL. The control group were $2.02{\pm}0.88$ g/mL, $1.68{\pm}0.87$ g/mL and $2.19{\pm}1.88$ g/mL. Conclusion: The effect of the intake of Metformin was observed from the SUV on region of large bowel in this study. Thus, it could be helpful for the results by identifying the ingredient of anti-diabetic drug before the examination and the possibility of interpretation of false positive will be reduced.

  • PDF

Usefulness of $^{18}F$-FDG Fusion PET for Diagnosing an Early Stage Cancer (조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성)

  • Jeon, Jae-Hwan;Kim, Byeong-Jin;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.145-149
    • /
    • 2010
  • Purpose: Recently, $^{18}F$-FDG Fusion PET which has a high sensitivity for diagnosing cancer is being used for purpose of health examination. This study is to demonstrate that $^{18}F$-FDG fusion PET study is useful for diagnosing an early stage cancer. Materials and Methods: This research has been conducted with 2790 patients visited Seoul National University Hospital Healthcare System (SNUHHS) for $^{18}F$-FDG fusion PET study for a health examination from February, 2004 to December 2008. PET/CT images were acquired from skull base to femur after 1 hour from injecting $^{18}F$-FDG 0.14 mCi/kg to the patients. GEMINI GS (Philips, Netherlands) was used for scanning. Results: From February 2004 to December 2008, $^{18}F$-FDG Fusion PET study was performed for 99,009 patients among all patients who visited SNUHHS and 2,790 patients was performed. Diagnostic rate for malignant cancer was 0.95% for the patients who were not examined by $^{18}F$-FDG Fusion PET study. 1.94% was for the patients who were. The rate of malignant tumor was showed 10% and benign tumor was 90% among 542 patients who showed abnormality in the PET/CT images. Types and rates of malignant tumor showed thyroid cancer: 31.5%, lung cancer: 14.8%, stomach cancer: 9.3%, rectum cancer: 3.7%, breast cancer: 3.7%, metastasis cancer: 16.7%. Nonspecific lymph node in the mediastinum, physiologic uptake in the colon, diffuse mild hypermetabolism in bilateral thyroid gland were shown as a benign tumor. Conclusion: The diagnostic rate of malignant tumor with $^{18}F$-FDG Fusion PET for a purpose of health examination was relatively higher than general medical examination. Consequently, it is superior and useful for applying $^{18}F$-FDG Fusion PET study for health examination.

  • PDF

Ovarian and Endometrial $^{18}F$-FDG Uptake During the Menstrual Cycle in Normal Premenopausal Patients: Evaluation by PET/CT (월경주기에 따른 $^{18}F$-FDG PET/CT의 자궁 내 섭취에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.43-47
    • /
    • 2009
  • Purpose: The menstrual cycle of normal premenopausal patients was divide into menstrual flow phase, proliferative phase, ovulatory phase, secretory phase. The aim of this study was to ovarian and endometrial $^{18}F$-FDG uptake during the menstrual cycle in normal premenopausal patients. Materials and Methods: We identified 200 incidental $^{18}F$-FDG uptake in the ovary. The patient fasted at least 6 hours before receiving an intravenous injection of 370-592 MBq (10-16mCi) of $^{18}F$-FDG. Scanning from the base of the skull though the mid thigh was performed using the Discovery Ste PET/CT system (GE Healthcare, Milwaukee, WI, USA). Ovarian and endometrial $^{18}F$-FDG uptake (expressed as standardized uptake value) was measured on PET/CT image. Results: Two peaks of increased endometrial $^{18}F$-FDG uptake were identified during the menstrual cycle. The $SUV_{avg}$ and $SUV_{max}$ was $2.89{\pm}1.04$ and $3.17{\pm}1.59$ in menstruating patients, $2.4{\pm}0.88$ and $2.98{\pm}1.14$ in proliferative phase patients, $3.59{\pm}1.76$ and $3.17{\pm}1.67$ in ovulatory phase patients, $2.58{\pm}1.39$ and $3.1{\pm}1.8$ in secretory phase patients. Conclusions: Increased ovarian and endometrial $^{18}F$-FDG uptake could be found the time of menstrual flow and ovulatory phase of menstrual cycle. Increased uptake in endometrial adjacent to a cervical tumor does not necessarily reflect endometrial tumor invasion. Since increased uptake was dependent on the menstrual cycle, it can be avoided by scheduling PET/CT just after menstruation. Non-menstrual-related endometrial uptake may be instrumental in establishing a diagnosis in a premenopaual patient.

  • PDF

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Comparison of the SNR in the MR images on dental implant material (치아 임플란트 재료에 따른 자기공명영상의 SNR 비교)

  • Kim, Dong-Hyun;Ko, Seong-Jin;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.149-155
    • /
    • 2015
  • Tooth implant is located in oral cavity and affects neck, skull base, and facail image. These magnetic inhomogeneities are usually frequency encoding direction which cause artifacts due to change of signal strength and geometric distortion. First, to evaluate signal to noise ratio (SNR) of magnetic resonance image caused by tooth implant this study uses meat phantom which is similar to human body and is consisted with fat, muscle, and water to measure signal to noise ratio. Second, signal to noise ratio by using custom-made fixed phantom is measured, and then signal to noise ratio size of different tooth implant types is compared and analyzed. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for meat phantom were 2.76, 2.22, 1.88, and 1.57 on T1 SE, 1.88, 1.78, 1.65, and 1.79 on T2 FLAIR, 2.28, 2.25, 2.88, and 2.05 on T2 FSE, and 2.74, 1.94, 1.67, and 1.48 on T2 GRE. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for fixed water phantom were 1.2, 1.06, 1.12, and 1.22 on DWI, 1.93, 1.87, 1.93, and 2.06 T1 SE, 1.83, 1.76, 1.82, and 1.92 on T2 FLAIR, 1.85, 1.79, 7.86, and 1.97 on T2 FSE, and 1.97, 1.93, 1.99, and 2.06 on T2 GRE. By considering through the results, patients and dentists need to consider some impacts from testing many aspects although their main purpose of having tooth implants is a dental restoration. Moreover, depending on the tooth implant characteristics of individual patients this study results can be used as baseline data when choosing test protocol.

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF

Usefulness of Stomach Extension after Drinking Orange Juice in PET/CT Whole Body Scan (PET/CT 전신 영상에서 오렌지 주스(Orange Juice)를 이용한 위장 확장 영상의 유용성)

  • Cho, Seok-Won;Chung, Seok;Oh, Shin-Hyun;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.86-92
    • /
    • 2009
  • Purpose: The PET/CT has a clear distinction on the lesion of the functional image by adding anatomical information. It also could reduce the examination time using CT data as the attenuation-correction. When the stomach was contracted from a fast, it could bring a misinterpretation of the cancer of the lesion with a presence of physiological $^{18}F$-FDG uptake in stomach and it occasionally would bring an additional scan to confirm. To complement this shortcoming, the method that the patients had water before the examination to extend the stomach had been attempted. However, a short excretion time of the stomach did not give sufficiently extended image of the stomach. Then the patients had additional water and had the examination again. Therefore, the noticed fact is that the stomach excretion time depends on calories, protein content, and the level of carbohydrate. In this study, we use an orange juice to evaluate the extension of the stomach and usefulness of it. Materials and Methods: PET/CT scan were obtained on total 150 of patient from February 2008 to October2008, There were 3 groups in this study and each group had 50 patients. First group drank nothing, Second group drank water and third group drank orange juice. The patients (man 25, female 25) not drinking are the age of 30~71 years old (average: 54), the patients (man: 25, female: 25) drinking water (400 cc) are the age of 28~71 years old (average: 54) and the patients (man: 25, female: 25) drinking orange juice (400 cc) are the age of 32~74 years old (average: 56). The patients were fasted in 6-8 hours before the test, the patients were not diabetic. $^{18}F$-FDG 370~555 MBq were injected intravenously. The patients were in stable position for 1 hour, than the image was obtained. The patients drank water and other patients drank orange juice before Whole body scan. The image scan started from mid-femur to skull base. The emission scan acquired for three minutes per bed and the images were reconstructed. Stomach extension analysis is measured from vertical and horizontal length. Results: Stomach Extension was described as the vertical length of the Non Drink Group was $1.20{\pm}0.50\;cm$, horizontal length was $1.4{\pm}0.53\;cm$, the vertical length of the Water Drink Group was $1.67{\pm}0.63\;cm$, horizontal length was $1.65{\pm}0.77\;cm$, the vertical length of Orange juice Drink Group was $3.48{\pm}0.77\;cm$, horizontal length was $3.66{\pm}0.77\;cm$ in coronal image. Stomach Extension was described the vertical length of the Non Drink Group was $2.03{\pm}0.62\;cm$, horizontal length was $1.69{\pm}0.68\;cm$, the vertical length of Water Drink Group was $5.34{\pm}1.62\;cm$, horizontal length was $2.45{\pm}0.72\;cm$, the vertical length of Orange juice Drink Group was $7.74{\pm}1.62\;cm$, horizontal length was $3.57{\pm}0.77\;cm$ in transverse image. The Stomach Extension has specific differences (p<0.001). The SUVs shows the Non Drink Group were measured as Liver $2.52{\pm}0.42$, Lung $0.51{\pm}0.14$, the Water Drink Group were measured as Liver $2.47{\pm}0.38$, Lung $0.50{\pm}0.14$, Orange juice Drink Group were measured as Liver $2.47{\pm}0.38$, Lung $0.50{\pm}0.14$. The SUVs did not have specific differences (p>0.759). Conclusions: There was not a large difference of SUV in three groups. When the patients drank Orange juice and water, the range extension of stomach was higher than without drinking nothing and it was possible to acquire fully extended images. Therefore, it will be possible that unnecessary additional stomach scans will be reduced by drinking orange juice before the examination so that the patients' claim from uncomfortable and long period of fast will be minimized.

  • PDF