• Title/Summary/Keyword: Skin patch

Search Result 174, Processing Time 0.023 seconds

The Safety Evaluation of a Potent Antioxidant, Fructose 1,6-diphosphate(FDP), for the Skin Application (항산화력이 우수한 Fructose 1,6-diphosphate(FDP)를 피부적용제로 응용하기 위한 안전성 평가)

  • 김배환;이병석;정경미;안수미;안수선;심영철
    • Toxicological Research
    • /
    • v.18 no.3
    • /
    • pp.267-273
    • /
    • 2002
  • Fructose 1,6-diphosphate(FDP), a glycolytic metabolite, is reported to ameliorate inflammation and inhibit the nitric oxide production in murine macrophages stimulated with endotoxin. It is also reported that FDP has cytoprotective effects against hypoxia or ischemia/reperfusion injury in brain and heart, and may play a protective role in ultraviolet B (UVB, 280~320 nm)-injured keratinocyte by attenuating prostaglandin (PG)-E$_2$production and cyclooxygenase (COX)-2 expression, which are possibly through blocking the intracellular reactive oxygen species (ROS) accumulation. Therefore FDP is considered to act as a potent antioxidant especially in the skin. We conducted the several safety tests (single-dose toxicity, primary skin irritation test, eye irritation test, skin sensitization test, phototoxicity test, photosenitization test and human patch test) to see if FDP is safe in case used for the skin application. Our data obtained hitherto suggest that FDP is very safe if applied to the skin.

OBSERVATION ON PATCH TEST USING A FEW DENTAL MEDICAMENTS BASED ON NURSING ASPECT (치과용 약제 접촉이 인체피부조직에 미치는 영향에 관한 간호학적 고찰)

  • Han, Song-Ja
    • The Journal of the Korean dental association
    • /
    • v.16 no.12 s.115
    • /
    • pp.941-944
    • /
    • 1978
  • The author studied skin reactions and their incidences among 100 dental students and dental nurses to 2% Lidocaine HC1, 3% H₂O₂, Euginol, 5% Sodium Hypochlorite, Dycal and Adhesive plaster by means of Patch test. Following are the results of the study. 1. Eighty six cases out of 100 revealed slight response to 1 or 2 allergens. 2. 2% Lidocaine HC1 showed 1 case, 3% H₂O₂cases, Euginol 2 cases, 5% Sodium Hypochlorite 74 cases, Dycal 1 case Adhesive plaster 8 cases. 3. 5% Sodium Hypochlorite was the most influential to skin. 32 cases showed grade 1+, 20 cases showed grade 2++, 16 cases showed grade 3+++, 6 cases showed grade 4++++,

  • PDF

Development of Laser Speckle Flowgraphy System for Monitoring Blood Flow in Skin Tissue (레이저 산란 현상을 이용한 피부혈류 화상화 시스템의 개발)

  • Lee, M.C.;Fujii, H.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.392-396
    • /
    • 2007
  • In this paper, we develop a new system to visualize the blood flow map in skin tissue, using the technique of Laser Speckle Flowgraphy (LSFG). The measuring unit consists of the laser diode, imaging system, line sensor, scanning mirror, and one-board microcomputer. The speckle signal is analyzed and sent to a PC, where the blood flow in a tissue area of $14mm{\times}26 mm$ is evaluated and displayed in a 2-D color map. It is demonstrated that the new LSFG instrument is useful to evaluate the degree of allergic reaction in patch test.

Allergic to Pool Water

  • Stenveld, Harma
    • Safety and Health at Work
    • /
    • v.3 no.2
    • /
    • pp.101-103
    • /
    • 2012
  • To identify the allergy problem of a 36-year old swimming instructor, who experiences heavy itching and rashes whenever she comes in contact with pool water. Patch tests were performed with European standard series and materials from the work floor. A positive patch test to aluminum chloride and flocculant was observed. Occupational dermatitis is, based on a contact allergy to aluminum chloride in the flocculant.

Characterization of Fracture Behavior in Repaired Skin/Stiffener Structure with an Inclined Central Crack

  • Chung, Ki-Hyun;Yang, Won-Ho;Heo, Sung-Pil
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.599-608
    • /
    • 2002
  • Finite element analysis for the stress intensity factor (SIF) at the skin/stiffener structure with inclined central crack repaired by composite stiffened panels is developed. A numerical investigation was conducted to characterize the fracture behavior and crack growth behavior at the inclined crack. In order to investigate the crack growth direction, maximum tangential stress (MTS) criterion are used. Also, this paper is to study the performance of the effective bonded composite patch repair of a plate containing an inclined central through-crack. The main objective of this research is the validation of the inclined crack patching design. In this paper, the reduction of stress intensity factors at the crack-tip and prediction of crack growth direction are determined to evaluate the effects of various non-dimensional design parameter including; composite patch thickness and stiffener distance. We report the results of finite element analysis on the stiffener locations and crack slant angles and discuss them in this paper. The research on cracked structure subjected to mixed mode loading is accomplished and concludes that more work using a different approaches is necessary. The authors hope the present study will aid those who are responsible for the repair of damaged aircraft structures and also provide general repair guidelines.

A Fracture Mechanics Analysis of Bonded Repaired Skin/Stiffener Structures with Inclined Central Crack (경사균열을 갖는 Skin/Stiffener 구조물의 보수에 의한 균열의 파괴역학적 거동)

  • Chung, Ki-Hyun;Yang, Won-Ho;Kim, Cheol;Heo, Sung-Pil;Ko, Myung-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.292-297
    • /
    • 2001
  • Composite patch repair of cracked aircraft structures has been accepted as one of improving fatigue life and attaining better structural integrity. Analysis for the stress intensity factor at the skin/stiffener structure with inclined central crack repaired by composite stiffened panels are developed. A numerical investigation was conducted to characterize the fracture behavior and crack growth behavior. In order to investigate the crack growth direction, maximum tangential stress(MTS) criteria is used. The main objective of this research is the validation of the inclined crack patching design. In this paper, the reduction of stress intensity factors at the crack-tip and prediction of crack growth direction are determined to evaluate the effects of various non-dimensional design parameter including; composite patch thickness and stiffener distance. The research on cracked structure subjected to mixed mode loading is accomplished and it is evident that more work using different approaches is necessary.

  • PDF

Analysis of Characteristics of Peripheral Arterial Ischemia in Premature Babies and Effects of Nitroglycerin Patch Application

  • Kim, Jeongeun;Lee, Jin Won;Kim, Dong Yeon
    • Child Health Nursing Research
    • /
    • v.26 no.4
    • /
    • pp.434-444
    • /
    • 2020
  • Purpose: The aim of this retrospective study was to analyze the characteristics of peripheral arterial ischemia and tissue necrosis in premature babies, as well as the effects of nitroglycerin. Methods: In total, 513 newborns were enrolled who were admitted to the neonatal intensive care unit with a gestational age of 34 weeks or younger. Data were collected on general personal and clinical information, peripheral arterial ischemia, and nitroglycerin patch application in the premature infants. The collected data were analyzed using the χ2 test, t-test, Mann-Whitney U test, logistic regression. Results: Thirty-six (7.0%) infants had peripheral arterial ischemia, while 477 (93.0%) infants did not. Lower gestational age (χ2=35.97, p<.001), lower birth weight (χ2=29.40, p<.001), lower blood pressure (χ2=23.10, p<.001), and insertion of an umbilical artery catheter (p<.001) were significantly associated with the occurrence of peripheral arterial ischemia. Among the preterm infants in whom nitroglycerin patches were applied, 30 (83.3%) premature infants without necrosis improved without complications, 4 (11.1%) showed hypotension, and 2 (5.6%) showed skin damage. Conclusion: Based on a review of our experiences with nitroglycerin patches, we recommend closely observing skin color and using nitroglycerin patches on the skin to help improve flow in premature infants with peripheral arterial ischemia.

Development of Transdermal Delivery Systems Containing Clenbuterol (클렌부테롤 경피흡수제제의 개발)

  • Choi, Han-Gon;Quan, Qi-Zhe;Jung, Si-Young;Rhee, Jong-Dal;Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.247-252
    • /
    • 2000
  • The advantages of transdermal administration are avoiding hepatic first pass effect, minimizing inter- and intra-patient variation, maintaining steady-state plasma level to provide long-term therapy from a single dose, and allowing a rapid termination of drug input. Clenbuterol, a selective ${\beta}_2-adrenergic$ receptor stimulant, has been introduced as a potent bronchodilator for patients with bronchial asthma, chronic obstructive bronchial disease. For the development of transdermal systems containing clenbuterol, two limiting factors - long lag time and low flux - must be overcome. In this study, we attempted to select optimal formulation for preparation of clenbuterol patch using hairless mouse skin and flow-through diffusion cell. The flux of clenbuterol increased as the percent of clenbuterol dose dependently in the concentration range of 5-15%. Based on this result, we fixed the concentration of clenbuterol as 15%. The effect of various penetration enhancers on percutaneous absorption of clenbuterol through hairless mouse skin was investigated. Labrafil was the most effective enhancer, which increased the permeability of clenbuterol approximately 4-fold compared with the control without penetration enhancer. Optimal enhancer concentration was 3%. The effect of various adhesives on penetration of clenbuterol was also investigated. Among the adhesives studied, MA-31 was the most effective adhesive. Furthermore, the clenbuterol patch composed of 15% clenbuterol, 3% Labrafil and 82% MA-31, which gave most excellent penetration of drug in in vitro penetration study, maintained therapeutic plasma levels in in vivo study using S.D. rats. These studies demonstrated a good feasibility of clenbuterol administration through the intact skin using a transdermal patch, and show a possibility of the development of clenbuterol patches.

  • PDF

Synthesis and Biocompatibility Study of Hydrogel for Patch Sensor in Non-invasive Glucose Monitoring System (무채혈 혈당 측정시스템의 Patch Sensor용 수화젤의 합성 및 생체적합성에 관한 연구)

  • Kwon, Jeong-Woo;Kim, Dong-Chul;Yoon, In-Joon;Jeong, Yoon-Na;Jeong, Ji-Young;Hwang, In-Sik
    • Polymer(Korea)
    • /
    • v.33 no.2
    • /
    • pp.111-117
    • /
    • 2009
  • This study aims to verify for humans the suitability of the enzyme-fixed hydrogel used for the patch sensor of the blood sugar testing system without blood sampling, which utilizes reverse iontophoresis. Using acrylate monomers, hydrogel was synthesized to which a certain unit of enzyme is fixed. In order to analyze the material property of the synthesized hydrogel, a structural analysis was performed using FT-IR spectroscopy, while the DSC was used to verify the thermal stability. In addition, with the UV-Vis spectrophotometer, it was verified that the degree of active enzyme is at least 50% greater than the standard product. The SEM was used to verify secure fixation of the enzyme onto the surface. As a result, it was observed that the enzyme is successfully fixed to the surface. Since the hydrogel makes direct contact with a patient's skin, it is essential to evaluate the toxicity when making direct contact with the skin. For that purpose, various sets of tests were undertaken according to the ISO 10993-cytotoxicity, intracutaneous reactivity, skin irritation test and maximization sensitization. Consequently, it was successfully verified that the enzyme-fixed hydrogel have bioavailability.

A Case of Contact Dermatitis by Pain Relieving Patch Deteriorated after Taking Lotus Root (파스 접촉 알레르기 치료 중 연근 복용 후 악화된 중등도 알레르기 피부 1례)

  • Lim, Kyeong-Min;Choi, Jung-Hwa;Park, Soo-Yeon;Kim, Jong-Han;Kim, Seon-Jong;Shin, Jeong-Cheol;Jung, Min-Yeong
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.28 no.3
    • /
    • pp.126-134
    • /
    • 2015
  • Objectives : The purpose of this study is to report that Korean medical treatment is good for deteriorated moderate allergic skin after taking lotus root while getting treatment for contact dermatitis by pain relieving patch.Methods : A 54-year-old woman patient with allergic contact dermatitis received treatment with acupuncture, herbal medicine, etc. We used observation and Visual Anologue Scale(VAS) to evaluate recovery from erythema, pruritus and skin damages.Results : A visible symptoms to the naked eye and VAS scale were effectively decreased after Korean medicine treatments.Conclusions : Korean medical treatments were effective for allergic contact dermatitis deteriorated by lotus root while getting treatment contact dermatitis by pain relieving patch.