• 제목/요약/키워드: Skin care medical device

검색결과 20건 처리시간 0.026초

Urosepsis and postrenal acute renal failure in a neonate following circumcision with Plastibell device

  • Kalyanaraman, Meena;McQueen, Derrick;Sykes, Joseph;Phatak, Tej;Malik, Farhaan;Raghava, Preethi S.
    • Clinical and Experimental Pediatrics
    • /
    • 제58권4호
    • /
    • pp.154-157
    • /
    • 2015
  • Plastibell is one of the three most common devices used for neonatal circumcision in the United States, with a complication rate as low as 1.8%. The Plastibell circumcision device is commonly used under local anesthesia for religious circumcision in male neonates, because of cosmetic reasons and ease of use. Occasionally, instead of falling off, the device may get buried under the skin along the shaft of the penis, thereby obstructing the normal flow of urine. Furthermore, the foreskin of neonates is highly vascularized, and hence, hemorrhage and infection are possible when the skin is cut. Necrosis of penile skin, followed by urethral obstruction and renal failure, is a serious surgical mishap requiring immediate corrective surgery and medical attention. We report a case of fulminant urosepsis, acute renal failure, and pyelonephritis in a 4-day-old male neonate secondary to impaction of a Plastibell circumcision device. Immediate medical management was initiated with fluid resuscitation and mechanical ventilation; thereby correcting life threatening complications. Pediatricians and Emergency Department physicians should be cognizant of the complications from Plastibell circumcision device in order to institute appropriate and timely management in neonates.

소아중환자실 환아의 호흡기계 의료장치 관련 욕창 발생 관련 특성 (Characteristics Influencing the Occurrence of Respiratory Medical Device-related Pressure Ulcers in the Pediatric Intensive Care Unit)

  • 김혜경;김영혜;손현미
    • Child Health Nursing Research
    • /
    • 제25권2호
    • /
    • pp.133-142
    • /
    • 2019
  • Purpose: This prospective study was conducted to determine the incidence and related characteristics of respiratory medical device-related pressure ulcers (MDRPU) in children admitted to a pediatric intensive care unit (PICU). Methods: The participants were 184 children who were admitted to the PICU of P University Hospital from April 2016 to January 2017. Data were collected on the occurrence of respiratory MDRPU and characteristics regarding the application of respiratory medical devices. Results: Respiratory MDRPU occurred in 11.9% of participants (58.3%: stage I ulcers, 37.5%: mucosal ulcers). The devices associated with respiratory MDRPU were endotracheal tubes (54.2%), high-flow nasal cannulas (37.5%), and oximetry probes (8.3%). Respiratory MDRPU associated with an endotracheal tube were significant differences according to the site and strength of fixation, the use of a bite block and adhesive tape, skin dryness, and edema. In high-flow nasal cannulas, significant differences were found according to the site of fixation, immobility after fixation, and skin dryness. Conclusion: The occurrence of respiratory MDRPU is significantly affected by the method and strength of fixation, as well as skin dryness and edema. Therefore, appropriate consideration of these factors in nursing care can help prevent respiratory MDRPU.

미세전류 자극이 얼굴 피부개선에 미치는 영향에 관한 임상시험 연구 (Clinical Test for Evaluation of Effectiveness of the Micro-current Stimulation in Facial Skin Care)

  • 조승관;김성국;김용민;박세근;이지환;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권5호
    • /
    • pp.195-207
    • /
    • 2016
  • This study examined the effectiveness of micro-current stimulation (MCS) to improve the facial skin qualities by performing clinical test. The MCS is generally known that provide healing response in the damaged tissue and pain relief through activating the adenosine triphosphate (ATP) and protein synthesis. In here, we can hypothesize that the improvement of facial skin qualities may occur due to MCS, since the induction of micro-current from outside may enhance the cellular activity according to ATP activation. From the clinical test, our results showed that a variety of evaluating categories, which is able to assess the skin qualities, significantly enhanced due to stimulation of micro-current after 7 and 14 days. Therefore, we can estimate that MCS in human facial skin may be effective to improve the skin qualities.

비만치료기 개발에 따른 저준위레이저에 관한 연구 (Study on low-level laser therapy device according to the obesity development)

  • 이상식;김준태;정진형;김남선
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권1호
    • /
    • pp.82-89
    • /
    • 2016
  • 경제성장과 더불어 고령화 사회로 진입하여 '아름답고 건강하게 사는 욕구'와, '항 노화'에 대한 관심이 증진됨에 따라 미학 산업이 유망사업으로 부각되어 스킨케어 시장을 크게 증가시켰다. 하지만 병원이나 전문 관리업체의 관리를 받기위해서는 시간적, 공간적, 비용적 제약이 발생하여, 이를 해결하기 위해 많은 업체들이 홈 케어 방면으로 접근하기 시작했다. 세계적인 추세로 개인용 스킨케어 시장이 활성화 되었으며, 국내는 경기침체로 인한 저비용, 개인용 시장이 활성화 되었다. 우리는 이러한 점을 보완하기 위하여 가정용 스킨케어 장치를 개발하기 위해 본 실험을 실시하였다. 본 논문에서는 개인용 스킨케어 제품을 만들기 위해 저준위 레이저를 개발하고 이를 피부 미용적으로 접목시키기 위해 노력하였다. 피부에 저준위 레이저를 사용함으로써 모공을 확장시켜 피부의 진피층까지 해당 앰플을 침투시키는데 목적을 두고 실험하였으며, 의료용 저준위 레이저와의 비교를 통하여 안정성 및 성능의 효율성 유무를 판단하고 상용화 할 수 있도록 노력하였다.

"내경(內經)" 중심으로 경락(經絡)과 피부(皮膚)에 관한 연구(硏究) (The mutation research which with problem of the Spleen and the Stomach appears in skin care)

  • 김명주;전현정
    • 대한한의정보학회지
    • /
    • 제14권2호
    • /
    • pp.11-20
    • /
    • 2008
  • This thesis' "Hwang Jae Nai Kyung(黃帝內經)", it is one among Uihak5kyung(醫學五經), is originally total of 18 volumes, the first half of 9 volumes are Somun(素問) and the latter half of the others are Youngchu(靈樞). Also, it is best of old book and literature integrating process of Chinese's medicine. Somun(素問) is comprehensive and extensive principles from fundamental problem of medical science related etiology, pathology, physiology to such parts of preventive medicine as regimen, recuperation. Moreover, therapeutic part of diagnosis and remedy, practice of acupuncture and moxibustion is recorded to Youngchu(靈樞). In the "Hwang Jae Nai Kyung(黃帝內經)", basic system takes precautions and medical cure for disease by approaching not method analyzing body but fundamentals of oriental medicine observed as organizing relation. For the purpose of mixing up beauty based on Buddhism of books, we shall pursuit notion of beauty treatment to method improving health because period flowing is changed to real well-being culture chasing outside beauty and healthy life. Then, to come close for part of oriental medicine and cosmetology, we shall present method of meridian pathways and understand device for cosmetic improvement by analyzing relation to 12 of pathways, the five viscera and the six entrails & skin.

  • PDF

Intense Pulsed Light의 안전성 및 성능평가를 위한 시험 항목 및 시험방법(안) 연구 (Guideline Development to Evaluate the Safety and Performance of Intense Pulsed Light(IPL))

  • 강동연;손태윤;주예일;최응호;정병조
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권2호
    • /
    • pp.129-133
    • /
    • 2010
  • Intense pulsed light(IPL) is a photo-therapeutic medical device using xenon lamps with optical characteristics of incoherence, defocusing, and polychromatic. IPL has been recognized as a representative medical therapeutic device with growth of domestic skin care market. However, there is no standard regulation manual and guideline to evaluate the safety and performance of IPL. International Electrotechnical Commission(IEC) is being statued "Technical Report IEC TR 60825-16" which is a guidelines for the safe use of intense light source equipment on humans and animals. In this study, a standard Korea Food & Drug Administration (KFDA) regulation for the safety and performance of IPL was suggested by developing minimal evaluation methods for optical parameters of IPL such as output energy density, pulse mode, spot size, wavelength and uniformity of output light. We expect that this study may be a step to statue a standard regulation manual and guideline for IPLs used in domestic.

플라즈마-초음파 자극에 의한 화장품의 피부 침투 증진 연구 (Study for Enhanced Skin Penetration of Cosmetics by Plasma-Sono Stimuli)

  • 황윤호;조혜연;박유진;장휘진;박상효;기재홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권4호
    • /
    • pp.275-283
    • /
    • 2023
  • The demand for skincare has increased due to the end of the COVID-19 pandemic, leading to a focus on skincare devices and technologies designed to improve the delivery of cosmetics. Among these technologies, skincare medical devices that utilize plasma therapy (Plasma) and sonophoresis (Sono) are commonly used in dermatology clinics. However, there is still a lack of quantitative analysis for transdermal absorption effects of Plasma and Sono skincare medical devices. In this study, we quantified enhanced transdermal absorption effects of Plasma and Sono devices through in-silico and ex-vivo studies. The Sono treatment demonstrated an increased transdermal absorption effect, showing a 10~13% difference in penetration compared to the control group in the in-silico experiment, and 159% and 184% increase in the ex-vivo experiment. The Plasma treatment revealed increased transdermal absorption effects, with a 1.0~2.5% penetration difference in the in-silico experiment, and a 124% increase in the ex-vivo experiment compared to the control group. We also observed a synergistic effect from the combined treatment of Plasma and Sono, as indicated by the highest increases of 197% and 242% in penetration. Furthermore, we have determined the optimal device settings and treatment conditions for Plasma-Sono skincare medical devices. Notably, higher on/off durations (Intensity levels) and longer Sono treatments resulted in greater transdermal absorption effects.

패치형 무선 피부 온도 측정 시스템의 설계 및 구현 (Design and implement of patch type wireless skin temperature measuring system)

  • 우상효;박수영;지아 모이 우딘;원철호;이정현;박희준;이정우;홍영진;서진호;염영일;조진호
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.350-360
    • /
    • 2008
  • In every large hospital, nurses must perform simple repetitive tasks such as measuring body temperature. Such tedious work reduces nurses' motivation to provide quality medical care, which is an important element of the medical services provided by a hospital. If a device were available to measure body temperature, nurses could focus on the more important aspects of providing quality medical care to the patients. However, body temperature is generally measured from the throat, anus, tympanum or armpit, where it is difficult to affix a patch type device. In addition, general body temperature measuring points shows moving artifact error; therefore, it is not good point to continually measure the temperature. In this paper, a patch type skin temperature measuring system was developed. To appropriately measure the skin temperature, a thermal transducer was implemented with a thin (0.5 mm) temperature sensor. The system is small and thin ($H6.6{\sim}5.3{\times}L35{\times}W24\;mm$), and weighs only 5 g including a battery, case and circuit; therefore, it is small and light enough to function as a patch type device. Moreover, the system worked for 5 days. To investigate differences between the experimental and conventional thermometer, simple clinical experiments were performed with 17 volunteers, and the result showed some correlation between the implemented system and conventional thermometer (Correlation coefficient = 0.647, P<0.1).

ICT기반의 피부 수분 및 자외선 측정이 가능한 스마트 밴드 및 데이터 모니터링 시스템 구현 (A Implementation of Smart Band and Data Monitoring System available of Measuring Skin Moisture and UV based on ICT)

  • 정세훈;심춘보;유강수;소원호
    • 한국전자통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.715-724
    • /
    • 2017
  • 현재 각종 스마트 기기가 발전되고 최근엔 인간의 신체에 부착되어 스마트 컴퓨팅이 가능한 Wearable Device 가 다양하게 연구되고 있다. 또한 인간의 환경적, 유전적 요인으로 인해 기미, 여드름, 아토피, 두피 트러블 등의 피부 질환들이 지속적으로 증가하고 있어 치료를 위한 개인의 의료 부담이 증가하고 있는 실정이다. 이에 따라 피부 미용과 관련된 다양한 피부 트러블을 분석하고, 관리할 수 있는 높은 휴대성과 진단 정확성을 가진 스마트폰이나 태블릿 기반의 스마트 헬스케어 이미징 시스템 개발의 필요성이 대두되고 있다. 이에 본 논문에서는 IoT를 기반으로 수분 및 UV 센서를 활용한 Wearable Device인 스마트 미밴드 H/W 및 센서정보 모니터링 S/W를 결합한 통합 시스템을 제안한다.

ECG 생체신호 측정을 위한 실용적 U-헬스케어 의복개발 (Development of the Practical Garment Apparatus to Measure Vital Sign of ECG for U-Health Care)

  • 박혜준;홍경희;김승환;신승철
    • 한국의류학회지
    • /
    • 제31권2호
    • /
    • pp.292-299
    • /
    • 2007
  • Development of portable device measuring the vital sign continuously with no limit of time and space is absolutely prerequisite for the U-health care that grafts the ubiquitous concept into medical system. Accordingly, it requires to develop a garment style apparatus for measuring vital-sign that is easy to wear on for a long time period. This study suggests a method to improve the insulation of electric cable and the skin adhesion of electrode by integrating the electric conductive material to garment, in order to develop a garment apparatus for measuring ECG for U-health care. Results of the research are as follows; In order to provide the adjacent conductive yarns with insulation, braid with narrow woven end was interlaced using polyester yarn. As a result, the direct contact between electric conductive yarns was restrained, which would be interposed into pin-tuck structured cable. Washable silicone gel applied around the electrode made of electric conductive fabric improved the adhesion, which prevents electrodes from dropping off from the skin surface during body movement. ECG signals on the human subject were tested using the garment apparatus developed by the above method. And the result was that the clear QRS wave formation in the typical form of ECG could be measured in both conditions of still and moving state as well. The result of this study is expected to contribute for the production of U-health care related medical apparatus by accelerating the practical uses of the garment measuring vital sign at a reasonable price.