• Title/Summary/Keyword: Skin Surface

Search Result 1,142, Processing Time 0.027 seconds

Can Daily-use Lipstick Make Lips More Fresh and Healthy\ulcorner - A New Lipstick Containing $\alpha$-Glucosyl-hesperidin Can Remove the Dull-color from Lips

  • Iwai, I.;Yamashita, T.;Ochiai, N.;Masuda, Y.;Hosokawa, K.;Kohno, Y.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.162-177
    • /
    • 2003
  • It has been known that the color of skin reflects the blood flow within. In lips, the capillaries close to the skin surface are numerous; hence lips are redder than the rest of face. However, dermatological research on lips is not as advanced as research on facial or body skin, and little was known about the relationship between relatively dull-colored lips and skin blood flow. The physiological differences between colorful and dull-colored lips were studied by a two-dimensional laser Doppler blood flow analyzer, a spectrometer for the measurement of the degree of oxygen saturation, and a confocal microscope for observing inside lips non-invasively. Dull-colored lips and the corner of lips (dull-colored compared to the center) showed relatively poor blood flow and lower oxygenated hemoglobin. It was found that colorful lips (generally the young) had a blood flow that tended to run straight in parallel with the skin surface. This unique blood-capillary structure can express clear red blood. Those with dull-colored lips had lost this unique structure. Their blood ran perpendicularly from the deep of the skin and down back again into the deep part as like the blood circulation patterns of facial skin. Therefore, the lips of the latter group had fewer blood capillaries near skin surface in the lips than that of the colorful-lips group. A lipstick containing a-glucosyl-hesperidin, which is derived from certain citrus fruits and can enhance blood circulation, was applied for evaluating its effects. Blood flow was increased 30 min after the application. After two weeks of daily application, the lips' condition became noticeably less dull. These findings suggest that the decrease of blood flow in dull-colored lips is caused by the loss of the unique capillary structure and the use of the lipstick to increase blood flow can give a vivid color to lips.

  • PDF

Heterogeneity of hard skin layer in wrinkled PDMS surface fabricated by Ar ion beam irradiation (아르곤 이온빔 조사로 형성된 주름진 PDMS 표면 경화층의 이질성)

  • Lee, Seunghun;Byeon, Eunyeon;Kim, Do-Geun;Jung, Sunghoon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.43.1-43.1
    • /
    • 2018
  • Spatial distribution of binding state in depth direction is investigated in a hard skin layer on soft polydimethylsiloxane (PDMS) fabricated by Ar ion beam irradiations. The hard skin layer known as a silica-like homogenous layer was composed of two layers. Impinging Ar ions transfer energy to PDMS as a function of collisional energy transfer rate, which is the maximum at surface and decreases gradually as an ion penetrates. This formed the heterogeneous hard skin layer that consists of a top-most layer and an intermediate layer. XPS depth profiling showed the existence of the top-most layer and intermediate layer. In the top-most layer, scission and cross-linking were occurred simultaneously and Si-O bond showed dissociated status, SiOx (x = 1.25 - 1.5). Under the top-most layer, there was the intermediate layer in which cross-linking is mainly occurred and Si-O bond showed silica-like binding status, SiOx (x = 1.75 - 2). And theoretical analysis which calculates the collisional energy transfer and a displacement per atom explained the thickness variation of top-most layer according to Ar ion energy from 360 eV to 840 eV.

  • PDF

3D Measurement of Skin Deformation for the Design of a Tight-fitting Torso Pattern (밀착형 셔츠 설계를 위한 피부변형의 3차원 측정)

  • Park, Hye-Jun;Wu, Yanjun;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.11
    • /
    • pp.1824-1835
    • /
    • 2010
  • This study develops tight-fitting torso patterns for performance garments by taking into account the skin deformation generated directly from a 3D scan during arm movements. The skin deformation caused during the arm movements was scanned after scanning the skin surface stamped with a circle. To create a torso pattern in response to skin deformation, the ratio and direction of the skin deformation were first measured and analyzed so that the 3D human body could be segmented. After translating, the 3D skin surface was segmented into 2D flat patterns, designing nude patterns and reducing them as well as tight-fitting shirts: the skin deformation segment shirts were made in response to the skin deformation. The features of the fabric deformation and the garment pressure were analyzed and evaluated. In comparison with a clothing construction segment shirt, the diameter of the skin deformation segment shirt was smaller as well the ratios of extension and reduction was less. The garment pressure of the skin deformation segment shirt was higher. The skin deformation segment shirt fitted more tightly compared to a clothing construction segment shirt as it covered the body more thoroughly and was as comfortable as the other shirts with less fabric deformation made as the body moved.

Optimization of Gelatin Extracting Condition from Korean Native Black Goat Skin and Quality Comparison with Commercial Gelatin

  • Youn-Kyung Ham;Sin-Woo Noh;Jae-Hyeok Lee;Na-Eun Yang;Yun-Sang Choi;Hyun-Wook Kim
    • Food Science of Animal Resources
    • /
    • v.43 no.1
    • /
    • pp.61-72
    • /
    • 2023
  • The practical use of Korean native black goat skin as a source of gelatin extraction is limited. The objective of this study was to optimize the extraction temperature and time of gelatin from Korean native black goat skin, and to compare the quality characteristics of goat skin gelatin and other commercial gelatin products. Response surface methodology was applied to optimize the extraction temperature and time of gelatin obtained from native Korean black goat skin. The effects of temperature (50℃-70℃) and time (2-4 h) on extraction yield and gel strength were investigated using a face-centered central composite design with 13 experiments. Gelatin extraction from Korean native black goat skin was prepared through the serial processes of alkali pre-treatment, bleaching, neutralization, hot-water extraction, and freeze-drying. Using the optimization plot of Minitab software, the optimized conditions for extracting temperature and time of goat skin gelatin were 59.49℃ and 3.03 h, and the optimized values of extraction yield and gel strength were 12.52% and 263.37 g, respectively. Based on a quality comparison of goat skin gelatin with commercial gelatin, the pH value of gelatin extracted from Korean native black goat skin was 5.57. The color of gelatin extracted from Korean native black goat skin was darker than that of commercial gelatin (p<0.05). Higher emulsifying properties and gel strength of goat skin gelatin were observed when compared to those of commercial gelatin (p<0.05). Therefore, the results of this study indicate that Korean native black goat skin may be a valuable source for gelatin extraction.

Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature (손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정)

  • Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.141-147
    • /
    • 2017
  • A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperature sensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuring pulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at $35^{\circ}C$ (the maximum wrist temperature), the device was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sensor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during temperature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect to thickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the compensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.

The Suggestion of MF BIA Analyzer Method to Reflect the Resistance in the Extracelluar and Intracelluar Fluid at Acupoint & the Evaluation of Reflection Rate on the Tissue under Skin (MF-BIA Analyzer를 이용한 경혈의 세포 내액과 외액에 의한 저항성분 추정 방법 제시 및 반영률 평가)

  • Kim, Soo-Byeong;Lee, Na-Ra;Kim, Won-Ky;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.29 no.4
    • /
    • pp.563-572
    • /
    • 2012
  • Objectives : The aim of this study was to suggest a new method to estimate the resistance by acupoint compositions by using the multi-frequency bioelectrical impedance analysis(MF-BIA) of 5 kHz, 50 kHz and 200 kHz within 2 cm of acupoints as a local segment. Moreover, we try to confirm the relation to between measured resistance at skin surface and measured resistance by various manual acupuncture needle insertion depth. Methods : Ten male subjects participated in this study. We measured the resistance at left/right ST36 at skin surface and various manual acupuncture needle insertion depth(skin, 5 mm, 10 mm, 15 mm, 20 mm, 25 mm and 30 mm). Results : It was also observed that the all measured resistances were the highest at 5 kHz and the lowest at 200 kHz. There were significant differences at 5 kHz, 50 kHz and 200 kHz between measured resistance at skin surface and measured resistance by various manual acupuncture needle insertion depth(p<0.05). There was no significant difference in the left and right identical acupoints under the identical condition(p>0.05). Conclusions : We conclude that the measured resistance at skin surface has limitation as to reflect the information of tissue. However, the measured resistance at each frequency was changed as similar pattern by different insertion depth. Hence, we confirmed the possibility of assumption on information of tissue which was expected to locate an acupoint.

A comparison of the Effects of Intravenous Fluid Warming and Skin Surface Warming on Peri-operative Body Temperature and Acid Base Balance of Elderly Patients with Abdominal Surgery (수액가온요법과 피부가온요법이 개복술 환자의 저체온 예방에 미치는 효과 비교)

  • Park, Hyo-Sun;Yoon, Hae-Sang
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.7
    • /
    • pp.1061-1072
    • /
    • 2007
  • Purpose: The purpose of this study was to compare the effects of intravenous fluid warming and skin surface warming on peri-operative body temperature and acid base balance of abdominal surgical patients under general anesthesia. Method: Data collection was performed from January 4th, to May 31, 2004. The intravenous fluid warming(IFW) group(30 elderly patients) was warmed through an IV line by an Animec set to $37^{\circ}C$. The skin surface warming(SSW) group(30 elderly patients) was warmed by a circulating-water blanket set to $38^{\circ}C$ under the back and a 60W heating lamp 40 cm above the chest. The warming continued from induction of general anesthesia to two hours after completion of surgery. Collected data was analyzed using Repeated Measures ANOVA, and Bonferroni methods. Results: SSW was more effective than IFW in preventing hypothermia(p= .043), preventing a decrease of $HCO_3{^-}$(p= .000) and preventing base excess(p= .000) respectively. However, there was no difference in pH between the SSW and IFW(p= .401) groups. Conclusion: We conclude that skin surface warming is more effective in preventing hypothermia, and $HCO_3{^-}$ and base excess during general anesthesia, and returning to normal body temperature after surgery than intravenous fluid warming; however, skin surface warming wasn't able to sustain a normal body temperature in elderly patients undergoing abdominal surgery under general anesthesia.

MONO-MATERIAL PRSSURE-CONDUCTIVE RUBBER SENSOR WITH TEMPERATURE SENSITIVITY FOR REALIZING ARTIFICIAL SKIN SENSING

  • Yuji, Jun-ichiro;Shida, Katsunori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1314-1317
    • /
    • 1997
  • For realizing artificial skin sensing as a final goal, a mono-material pressure-conductive rubber sensor which is also sensitive for temperature is described. Firstly, discimination of the hardness and the thermal property of material using a proposed sensor is presented. Furthermore, a tactile sensor constints of four pressure-conductive rubber sensor to discriminate surface model which imitaties the surface roughness of material is proposed.

  • PDF

Rejuvenating Effects of Facial Hydrofilling using Restylane Vital

  • Lee, Bong Moo;Han, Dong Gil;Choi, Won Seok
    • Archives of Plastic Surgery
    • /
    • v.42 no.3
    • /
    • pp.282-287
    • /
    • 2015
  • Background Morphological changes that accompany aging, such as wrinkles and skin laxity, are particularly prominent on facial skin. Recently, facial rejuvenation using the hydrofilling effect of hyaluronic acid (HA) filler has been employed for improvement of skin texture. In this study, we studied rejuvenating effects of stabilized HA (Restylane Vital) through direct intradermal injections. Methods A total of 30 female patients underwent a series of procedures on face, including three sessions at intervals of four weeks. A total of 2 mL of Restylane Vital was injected along the whole face using an automatic injector. Improvement of skin surface roughness, elasticity, brightness, moisture, and fine wrinkles was evaluated. Patient satisfaction was evaluated, and pictures of patients were taken at each visit and 6 months after last treatment session. Scoring for each patient was performed by three doctors according in five subjects. Moisture, oil and elasticity were measured before the procedure and before the last treatment in 10 patients. Results The majority of patients (77%) were satisfied with the therapeutic outcomes. Approximately 66% of patients responded that the effects of this procedure persisted for longer than four months, and the majority of patients (77%) wanted to undergo this procedure again and would recommend this procedure to acquaintances. Regarding doctors' evaluation, scores for improvement of skin surface roughness, elasticity, and brightness were significantly higher than those for improvement of moisture and fine wrinkle. Conclusions Intradermal injection of HA can have a rejuvenating effect on dry and tired facial skin, especially in improvement of skin surface roughness.

A Study of Effect on Skin Temperature by Jadeite Powder Containing O/W Emulsion Formulation (원적외선 방사체인 경옥 파우더를 함유하는 스킨케어 화장품 제형이 피부 온도 변화에 미치는 영향에 대한 연구)

  • Kim, Na Ri;Shim, Jongwon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.2
    • /
    • pp.201-210
    • /
    • 2018
  • In this study, we formulated oil-in-water emulsion composition for skin care products containing jadeite powder which is well known as far-infrared radiating material. Jadeite powder could sustain stable dispersion in aqueous solvents over a month and this helped mixing it high content in oil-in-water emulsion formulation. To identify the effect of jadeite as a far-infrared radiator materials relating to the skin surface temperature change, we applied emulsion formulation containing 2 weight percent jadeite powder onto facial skin surface and blank formulation together and analyzed surface temperature with thermo-vision. Our results showed that the temperature difference between jadeite powder formulation applied region and blank formulation reached to 1.5 ~ 2.0 degree Celsius. We also performed same test with nephrite powder and titanium dioxide powder but only jadeite powder containing formulation showed significant skin temperature change. To elucidate main cause of heat energy transfer, we tested heat radiation, energy dispersive spectrometer analysis and measured far infrared radiance emissivity, diffuse reflectance spectra and water evaporation rate. We found out jadeite powder could retard water evaporation effectively from the skin surface and resist temperature drop down. This is because of the innate chemical composition and surface structure of jadeite, which can bind with water molecules to form hydrogen bonds. It is concluded that we can develop novel skin care products for moisturizing and thermos with jadeite powder.