• Title/Summary/Keyword: Size ratio

Search Result 6,945, Processing Time 0.031 seconds

Evaluation of Validity Thyroid Scintigraphy Using Parallel Hole Collimator (갑상샘 신티그래피 검사 시 평행다공형 조준기 적용의 유효성 평가)

  • Su-Young Park;Ji-Youn Kim;Sung-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.27-36
    • /
    • 2024
  • In this study, When acquisition thyroid scintigraphy images, a parallel hole collimator was applied, and the difference from the pinhole collimator was quantitatively analyzed under each image acquisition condition. Visual size, resolution, sensitivity, signal to noise ratio (SNR), and contrast to noise ratio (CNR) were evaluated using thyroid phantom and point source. When comparing visual size, it was confirmed that an image similar to the size of the pinhole collimator could be obtained only when a magnification ratio of about 2.00 to 2.09 times when applying a parallel hole collimator. There was no tendency in FWHM(mm) measurement using a point source, and sensitivity was high in the parallel hole collimator. SNR and CNR were high when using a low magnification ratio, matrix size of 128×128, and a parallel hole collimator. In images of similar size to the naked eye, when the matrix size was the same, both SNR and CNR were high in the pinhole collimator. Therefore, when performing a thyroid scintigraphy test, if appropriate conditions are set according to the situation of each hospital and a parallel hole collimator is applied, it can be a good option in terms of equipment utilization and work efficiency.

Plasma LDL Particle Sizes Affect the Blood Lipid Profile and Dietary Intakes among Korean Adults (한국 성인에서 혈중 LDL 입자의 크기에 영향을 미치는 관련 인자 연구)

  • 서연경;김형숙;김정숙;김철호;최혜미
    • Korean Journal of Community Nutrition
    • /
    • v.9 no.1
    • /
    • pp.58-65
    • /
    • 2004
  • The purpose of this research was to examine the relationship between the plasma LDL particle size and blood lipid profile, dietary factors and anthropometric values (body mass index, waist circumference and waist/hip ratio). The subjects were 173 adults aged 23 to 81 years, selected from the Outpatient Clinic and Cardiovascular Department of the Seoul Municipal Hospital. Dietary data were obtained using a 3-day food record and analyzed using Korean and US nutrient databases. The subjects were divided into three groups by LDL particle size : type A (large buoyant LDL, > 25.5 nm, n=96), type I (Intermediate LDL,$25.2\leq-\leq25.5$ nm, n=18), and type B (small dense LDL, < 25.2 nm, n=59) groups. The type B group had higher age, waist circumference, and waist/hip ratio (WHR) than the type A and type I groups. Serum concentration of triglyceride, Apo B, LDL/HDL cholesterol ratio and atherogenic index were significantly higher in the type B group as compared to those in the other two groups. HDL cholesterol level and Apo A-I/Apo B ratio were significantly lower in the type B group than the other two groups. The plasma LDL particle size was highly correlated with triglyceride (r= -0.450), Apo B (r= -0.402) and HDL cholesterol (r= 0.418). However, there was no correlation between plasma LDL particle size and dietary intakes. This study showed that small dense LDL was an important biochemical risk factor that was associated with other risk factors.

The Effect of the Loading Size on Displacements of Stiffened Plates with Open Ribs (재하 크기가 개단면 리브 보강판의 처짐에 미치는 영향)

  • Chu, Seok Beom
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.563-574
    • /
    • 2006
  • The objective of this study is to determine the effect of the loading size on displacements of stiffened plates with open ribs using the orthotropic rigidity ratio as the parameter. To analyze the displacement behavior of stiffened plates according to the loading size, a concentrated load and three types of uniform distributed loads were applied on the rib at the center of some plates. The results of the analysis of various stiffened plates show that the central displacement ratio of the distributed load to the concentrated load increased according to the decrease in the loading size, and that the ratio can be expressed as a function of the rigidity ratio for each rib space. The maximum displacement of the stiffened plate subjected to the distributed load did not appear at the center of the plate due to the local behavior, and the increasing ratio of the maximum displacement to the central displacement can be expressed as a function of the rigidity ratio for each rib space. Orthotropic plate analysis can achieve more accurate results using the proposed functions, and the application of the functions to examples of a different aspect ratio and support condition shows good accuracy. Therefore, using the functions proposed in this study, the central and maximum displacements can easily be achieved in the orthotropic plate analysis of stiffened plates subjected to the distributed load.

Luminescent Characteristics of CdSe Quantum Dot Phosphor Depending on Se Precursor Ratio (Se 전구체 함량 따른 CdSe 양자점 형광체의 발광특성)

  • Eom, Nu Si A;Kim, Taek-Soo;Choa, Yong-Ho;Kim, Bum Sung
    • Journal of Powder Materials
    • /
    • v.19 no.6
    • /
    • pp.442-445
    • /
    • 2012
  • The quantum dots (QD) have unique electrical and optical properties due to quantum dot confinement effect. The optical properties of QDs are decided by various synthesis conditions. In a prior QDs study, a study on the QDs size with synthesis condition such as synthesis time and temperature is being extensively researched. However, the research on QDs size with composition ratio has hitherto received scant attention. In order to evaluate the ratio dependence of CdSe crystal, synthesis ratio of Se precursor is changed from 16.7 mol%Se to 44 mol%Se. As the increasing Se ratio, the band gap was increased. This is caused by red shift of emission. We confirmed optical property of CdSe QDs with composition ratio.

A Study on the Determination Information of Cash holdings in Korean Export-Oriented Companies (한국의 수출지향형 기업에서 현금유동성 결정정보에 관한 연구)

  • Kim, Jong-Taek;Shin, Yeon-Soo;Shin, Yong-Jae
    • International Commerce and Information Review
    • /
    • v.11 no.1
    • /
    • pp.157-176
    • /
    • 2009
  • This study analyzed the information factors which determine cash liquidity in Korean export-oriented companies. In this paper, cash liquidity means the ratio of the value of cash or cash equivalent to the asset value subtracted marketable securities value from total asset value. The empirical test shows that main information factors are the size of company, the growth opportunity of company, the volatility of operating cash flows and free cash flows, the credit yield spread of company, the debt ratio, the turnover ratio of cash flows and free cash flows, and the estimate of bankruptcy that amounts to the inverse number of Z score. In summary, the size of company, debt ratio, turnover ratio of cash flows and free cash flows, and Z-score have negative influence on the cash liquidity of Korean export-oriented companies. but the volatility of operating cash flows affect the cash liquidity positively.

  • PDF

The Relation of Crystallite Size and Ni2+ Content to Ferromagnetic Resonance Properties of Nano Nickel Ferrites

  • Lafta, Sadeq H.
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.188-195
    • /
    • 2017
  • The ferromagnetic resonance and other magnetic properties dependence on $Ni^{2+}/Fe^{3+}$ ratio and crystallite size were investigated for nano nickel ferrite ($NiFe_2O_4$). The crystallite size was controlled by controlling the nickel content in the starting material solution. The XRD and TEM were utilized to measure the crystallite size through Scherrer formula and particle size respectively. The most frequent particle sizes were lower than crystallite size, which ranged from 16.5 to 44.65 nm. The general behavior of M-H loop shapes and parameters showed superparamagnetic one. The saturation magnetization had a maximum value at $Ni^{2+}/Fe^{3+}$ molar ratio equal to 0.186. The FMR signals showed, generally, broad linewidths, where the maximum width and minimum resonance field were for the sample of the lowest crystalline size. Furthermore, FMR resonance field shows linear dependence on crystalline size. The fitting relation was estimated to express this linear dependency on the base of behavior coincidence between particle size and the inverse of saturation magnetization. The given interpretations to understand the intercept and the slope meanings of the fitted relation were based on Larmor equation, and inhomogeneous in the anisotropy constant.

Thermoluminescent Properties by the Cooling Temperature and Grain Size in the LiYSiO4 : La Phosphors (LiYSiO4: La 열형광체의 온도에 따른 열발광 특성)

  • Kim, Young-Kook
    • Korean Journal of Materials Research
    • /
    • v.19 no.9
    • /
    • pp.494-498
    • /
    • 2009
  • The thermoluminescent phosphors of LiYSi$O_4$ containing rare earth metal(La) dopants of 1 wt.%5 wt.% were prepared, and their TL characteristics have been investigated as a function of parameters such as the doping level and the heating rate. The grain size and cooling temperature of the highly sensitive LiYSi$O_4$: La phosphors have been investigated. The glow curve of LiYSi$O_4$: La has two peaks ($P_1,\;P_2$), and the peak height ratio of the two peaks is called $P_2/P_1$; here, the main peak is $P_2$. Experimental results indicate that the peak height ratios of the glow curve for LiYSi$O_4$: La are clearly correlated with the grain size and cooling temperature. The maximum $P_2/P_1$ ratio 3.25, the maximum sensitivity was observed for a grain size between 100-150 ${\mu}m$. The intensity of the TL peak of the phosphors was linearly proportion to the dose of X-rays.

Synthesis of Tungsten Carbide Powders by SHS Method (SHS법에 의한 탄화텅스텐 분말 합성)

  • Jun, H.B.;Cho, D.H.;Lee, H.B.;Park, S.
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.10
    • /
    • pp.1159-1168
    • /
    • 1994
  • We powders were synthesized from W powders in differnet particle sizes by Self-propagating High-temperature Synthesis process (SHS) using a chemical furnace. The effects of the mole ratio of chemical fuel content, pellet thickness and the mole ratio between carbon and tungsten (C/W Ratio) on synthesis were investigated with the tungsten powders have different particle size each other. Compositional and structural characterization of these powders was carried out by scanning electron microscope (SEM0 and x-ray diffractometer. Powder characterization was carried out by the measurement of particle size distribution with laser-particle size analyzer. The amounts of WC obtained by SHS process depend very much on the particle size of tungsten powder and heat contents given in a product, i.e. as the particle size of W powder is smaller, the amounts of WC produced increase. Also the more heat contents is given, the more amounts of WC increase. By optimizing the synthesis conditions, it is possible to fabricate WC powders which have little secondary phases (W2C, C).

  • PDF

Effect of Ceramic-Electrode Interface on the Electrical Properties of Multilayer Ceramic Actuators (적층형 세라믹 액츄에이터의 세라믹-전극간 계면이 전기적 특성에 미치는 영향에 대한 연구)

  • 하문수;정순종;송재성;이재신
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.896-901
    • /
    • 2002
  • The polarization and strain behavior of multilayer ceramic actuators fabricated by tape casting using a PNN-PZT ceramics were investigated in association with electrode size and internal layer number. Spontaneous polarization and strain decreased with increasing electrode size. In addition, the increase of internal layer number brought reduced spontaneous polarization and increased the field-induced strain. Because the actuators structure is designed to stack ceramic layer and electrode layer alternatively, the ceramic-electrode interfaces may act as a resistance to motion of domain wall. To analyze the effect of ceramic-electrode interface, the diffraction intensity ratio of (002) to (200) planes was calculated from X-ray diffraction patterns of samples subjected to a voltage of 200 V. The diffraction intensity ratio of (002) to (200) planes was decreased with increasing electrode size and internal layer number. The diffraction intensity ratio and straining behavior analyses indicate that the Polarization and strain were affected by the amount of 90°domain decreasing with increasing electrode size and internal layer number. Consequently, the change of polarization and displacement with respect to electrode size and layer number is likely to be caused by readiness of the domain wall movement around the interface.

A Study on the Characteristics of Continuous Scouring and Shrinking Equipment -Rota-drum and conveyor type- (연속 정련축소 장치의 특성 연구 -로터드럼형과 컨베이어형-)

  • 허만우;서말용
    • Textile Coloration and Finishing
    • /
    • v.12 no.1
    • /
    • pp.68-75
    • /
    • 2000
  • In this study, polyester DTY faille(yoryu) and N/NP microfiber fabrics were pretreated (desizing, scouring and shrinking) by Continuous Scouring and Shringking Equipment with rota-drum and conveyor type in which types were different with retaining method. The results were as follows. The shrinkage ratio of wp/wf direction of DTY fabrics scoured by conveyor type was 1.5/23% higher than those by rota-drum type at $97^\circ{C}$ with 10min. treatment. In this case, The shrinkage ratio of wp/wf direction by those types was about 15/27%, respectively. The shrinkage ratio of wp/wf direction of N/NP microfiber fabrics scoured by conveyor type was 1.5/23% higher than that by rota-drum type at $97^\circ{C}$ with 10min. treatment. The size add-on of DTY fabrics scoured at $97^\circ{C}$ with 10min. treatment by conveyor type and by rota-drum type were 0.15% and 0.42%, respectively. The size add-on of DTY fabric treated by rota-drum type decreased until 9min. of treated time, but increased after 9min. The size add-on of N/NP microfiber fabrics treated by conveyor type was decreased by increasing temperature and treated time, while the size add-on of that treated by rota-drum type was decreased until 6min. treated time and increased after 6min. The size add-on of N/NP microfiber fabrics treated by conveyor type at $97^\circ{C}$ for 10min. was 0.3% lower than that by rota-drum type.

  • PDF