• Title/Summary/Keyword: Size interval

Search Result 980, Processing Time 0.025 seconds

A Performance Evaluation of Multimedia Data Downstream with PDA over Wireless LAN (무선 랜 환경에서 PDA의 멀티미디어 데이터 다운스트림 성능 평가)

  • Hur Hye Sun;Hong Youn Sik;Woo Yo Seop
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.1
    • /
    • pp.71-78
    • /
    • 2005
  • When a PDA is used as a mobile terminal in an infrastructure network based on 802.11b standard wireless LAN, we measured and evaluated the performance of multimedia data transmission. In general, PDAs are mainly used tot receiving bulk data like multimedia data. However, while a PDA as a mobile host transfers multimedia data to a desktop PC as a fixed host in such a network, the time taken to receive data from the PC to the PDA is always longer than the time taken to send data from the PDA to the PC by at least 53%. Thus, we consider some critical factors that affect the time taken to receive Our experimental results show that with the PDA the time taken to access a file for writing is longer than the time taken to access a file for reading of to 4.11 times. In addition, a dramatic change of the site of the receiver window, from 686 bytes to 32,383 bytes, prolongs the time taken to receive. To transfer data without any inter-packet interval for the PDA and to increase the size of the TCP receive buffer will be effective in improving the delay to receive data.

  • PDF

Bone Flap Resorption Following Cranioplasty with Autologous Bone : Quantitative Measurement of Bone Flap Resorption and Predictive Factors

  • Park, Sang Pil;Kim, Jae Hoon;Kang, Hee In;Kim, Deok Ryeong;Moon, Byung Gwan;Kim, Joo Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.749-754
    • /
    • 2017
  • Objective : To quantitatively measure the degree of bone flap resorption (BFR) following autologous bone cranioplasty and to investigate factors associated with BFR. Methods : We retrospectively reviewed 29 patients who underwent decompressive craniectomy and subsequent autologous bone cranioplasty between April 2005 and October 2014. BFR was defined as : 1) decrement ratio ([the ratio of initial BF size/craniectomy size]-[the ratio of last BF/craniectomy size]) >0.1; and 2) bone flap thinning or geometrical irregularity of bone flap shape on computed tomographic scan or skull plain X-ray. The minimal interval between craniectomy and cranioplasty was one month and the minimal follow-up period was one year. Clinical factors were compared between the BFR and no-BFR groups. Results : The time interval between craniectomy and cranioplasty was $175.7{\pm}258.2$ days and the mean period of follow up was $1364{\pm}886.8$ days. Among the 29 patients (mean age 48.1 years, male : female ratio 20 : 9), BFR occurred in 8 patients (27.6%). In one patient, removal of the bone flap was carried out due to severe BFR. The overall rate of BFR was $0.10{\pm}0.11$ over 3.7 years. Following univariate analysis, younger age ($30.5{\pm}23.2$ vs. $54.9{\pm}13.4$) and longer follow-up period ($2204.5{\pm}897.3$ vs. $1044.1{\pm}655.1$) were significantly associated with BFR (p=0.008 and 0.003, respectively). Conclusion : The degree of BFR following autologous bone cranioplasty was 2.7%/year and was associated with younger age and longer follow-up period.

Astronomical Instruments with Two Scales Drawn on Their Common Circumference of Rings in the Joseon Dynasty

  • Mihn, Byeong-Hee;Choi, Goeun;Lee, Yong Sam
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.1
    • /
    • pp.45-54
    • /
    • 2017
  • This study examines the scale unique instruments used for astronomical observation during the Joseon dynasty. The Small Simplified Armillary Sphere (小簡儀, So-ganui) and the Sun-and-Stars Time-Determining Instrument (日星定時儀, Ilseong-jeongsi-ui) are minimized astronomical instruments, which can be characterized, respectively, as an observational instrument and a clock, and were influenced by the Simplified Armilla (簡儀, Jianyi) of the Yuan dynasty. These two instruments were equipped with several rings, and the rings of one were similar both in size and in scale to those of the other. Using the classic method of drawing the scale on the circumference of a ring, we analyze the scales of the Small Simplified Armillary Sphere and the Sun-and-Stars Time-Determining Instrument. Like the scale feature of the Simplified Armilla, we find that these two instruments selected the specific circumference which can be drawn by two kinds of scales. If Joseon's astronomical instruments is applied by the dual scale drawing on one circumference, we suggest that 3.14 was used as the ratio of the circumference of circle, not 3 like China, when the ring's size was calculated in that time. From the size of Hundred-interval disk of the extant Simplified Sundial in Korea, we make a conclusion that the three rings' diameter of the Sun-and-Stars Time-Determining Instrument described in the Sejiong Sillok (世宗實錄, Veritable Records of the King Sejong) refers to that of the middle circle of every ring, not the outer circle. As analyzing the degree of 28 lunar lodges (lunar mansions) in the equator written by Chiljeongsan-naepyeon (七政算內篇, the Inner Volume of Calculation of the Motions of the Seven Celestial Determinants), we also obtain the result that the scale of the Celestial-circumference-degree in the Small Simplified Armillary Sphere was made with a scale error about 0.1 du in root mean square (RMS).

Factors Associated with Echinococcosis-Induced Perioperative Anaphylactic Shock

  • Ye, Jianrong;Zhang, Qin;Xuan, Yan;Chen, Siyu;Ma, Long;Zhang, Yongqiang;Zheng, Hong
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.6
    • /
    • pp.769-775
    • /
    • 2016
  • This retrospective case-control study explored the factors associated with anaphylactic shock during surgery for cystic echinococcosis (CE) at the First Affiliated Hospital of Xinjiang Medical University between October 2008 and September 2013. Patients who suffered from anaphylactic shock (n=16) were age-matched 3:1 to patients who did not (n=43). Multivariate analysis suggested that IL-4 levels (odds ratio=1.096; 95% confidence interval=1.015-1.185; P=0.02) and cyst size (odds ratio=3.028, 95% confidence interval=1.259-7.283, P=0.013) were independently associated with CE-induced perioperative anaphylactic shock. Using the receiver operating characteristic (ROC) curves and a cut-off value of 415.7 ng/ml, IL-4 showed an area under the ROC (AUC) of 0.926, sensitivity of 75.0%, and specificity of 97.7%. Using a cut-off value of 7.8 cm, cyst size showed an AUC of 0.828, sensitivity of 81.3%, and specificity of 76.7%. In conclusion, results suggest that levels of IL-4 and cyst size were independently associated with echinococcosis-induced perioperative anaphylactic shock. These results could help identifying patients with echinococcosis at risk of anaphylactic shock in whom appropriate prophylaxis could be undertaken.

The Brief as a Measurement Garment (3차원 인체측정을 위한 측정용 브리프에 관한 연구)

  • Lee, Jun-Ok;Choi, Kyung-Mi;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.10 no.3
    • /
    • pp.329-334
    • /
    • 2008
  • The purpose of this research is to develop the design, pattern and size system of brief as a measurement garment in order to obtain more precise silhouettes and sizes of the body in 3D measurements. The results of this research are as follows: First, nylon/lycra materials which elasticity is equivalent to 18%(wale) and 27%(course), were selected as a material for briefs to minimize possible error in measurement and deformation of body shape caused by looseness or tightness in its measured parts. And T-back style design was selected, of which briefs neither deform human body nor cause overlapping or excessive tightness when was put on the measurement garment over it. Second, different darts for men and women were adopted into the pattern in consideration for the shape of hip. Third, the waist band of briefs was located between the waistline and abdominal girth line so that it didn't interfere with measurement, and using a wide band of 40mm minimized the tightness of the human body. In addition, the stitch lines and sewing procedure were simplified to minimize the deformation of body shape resulting from inseams and stitch lines. Finally, for the size of briefs, 6 cm intervals were set on the basis of the waist girth and 8 kinds for men and 6 kinds for women were selected in descending order of appearance rate by the interval sections. English T meaning T-back design and numbers representing the waist girth were marked in parallel for the name of size.

A Study on a Ranging Protocol for the ATM-PON Based ell ITU-T G.983.1 (G.983.1 기반의 ATM-PON을 위한 Ranging 프로토콜에 관한 연구)

  • Chung, Hae;Kim, Jin-Hee;Kwun, Sun-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.17-25
    • /
    • 2000
  • ATM PON system is regarded as a solution of the next generation access network because it can cover various types of subscribers in a single platform. In this paper, we describe the merit of the ATM PON and the key protocols for its operation. Above all, the ranging is the most important protocol providing a mean of the time-division multiple access in the system. A problem in the protocol is that the window size, the time interval that ranging cell arrives, is too long. During the interval, user traffics cannot be send to the upstream, which makes the quality of service degraded. In this paper, we suggest a method to minimize the window size when the length of the optic fiber is known with some deviation. The window size can be reduced as 7 % of the conventional method when the deviation of the length is 1 Km.

  • PDF

Assessment of population structure and genetic diversity of German Angora rabbit through pedigree analysis

  • Abdul Rahim;K. S. Rajaravindra;Om Hari Chaturvedi;S. R. Sharma
    • Animal Bioscience
    • /
    • v.36 no.5
    • /
    • pp.692-703
    • /
    • 2023
  • Objective: The main goals of this investigation were to i) assess the population structure and genetic diversity and ii) determine the efficiency of the ongoing breeding program in a closed flock of Angora rabbits through pedigree analysis. Methods: The pedigree records of 6,145 animals, born between 1996 to 2020 at NTRS, ICAR-CSWRI, Garsa were analyzed using ENDOG version 4.8 software package. The genealogical information, genetic conservation index and parameters based on gene origin probabilities were estimated. Results: Analysis revealed that, 99.09% of the kits had both parents recorded in the whole dataset. The completeness levels for the whole pedigree were 99.12%, 97.12%, 90.66%, 82.49%, and 74.11% for the 1st, 2nd, 3rd, 4th, and 5th generations, respectively, reflecting well-maintained pedigree records. The maximum inbreeding, average inbreeding and relatedness were 36.96%, 8.07%, and 15.82%, respectively. The mean maximum, mean equivalent and mean completed generations were 10.28, 7.91, and 5.51 with 0.85%, 1.19%, and 1.85% increase in inbreeding, respectively. The effective population size estimated from maximum, equivalent and complete generations were 58.50, 27.05, and 42.08, respectively. Only 1.51% of total mating was highly inbred. The effective population size computed via the individual increase in inbreeding was 42.83. The effective numbers of founders (fe), ancestors (fa), founder genomes (fg) and non-founder genomes (fng) were 18, 16, 6.22, and 9.50, respectively. The fe/fa ratio was 1.12, indicating occasional bottlenecks had occurred in the population. The six most influential ancestors explained 50% of genes contributed to the gene pool. The average generation interval was 1.51 years and was longer for the sire-offspring pathway. The population lost 8% genetic diversity over time, however, considerable genetic variability still existed in the closed Angora population. Conclusion: This study provides important and practical insights to manage and maintain the genetic variability within the individual flock and the entire population.

Change of MTF for Sampling Interval in Digital Detector (디지털 검출기에서 샘플링 간격에 따른 MTF의 변화)

  • Cho, Hyungwook;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.225-230
    • /
    • 2014
  • Assessments of medical image was improved in accordance with development of medical imaging systems. One of them is edge method to determining MTF(Modulation Transfer Function) based on the Fujita method. Fujita was reduced sampling interval used slightly angulated slit to the direction of pixel array and composited finely sampled LSF to determine presampling MTF. In this study, we investigate the effect of sampling interval on the MTF under a digital imaging system by changing wire angle. The wire method was equivalent to the slit method except signal appearance. A Simens's MAMMOMAT Inspiration with $0.085{\times}0.085mm^2$ pixel size made by amorphous selenium was used and 96% accuracy on MTF in twice sampling interval compared with Fujita was obtained. However, three times of sampling interval showed 93% accuracy on 50% of MTF and 85% accuracy on 10% of MTF.

Survey on the Brand of Online Custom Dress Shirts and Analysis of the Sizing System (온라인 맞춤 드레스셔츠 업체 현황조사 및 치수체계 분석)

  • An, Dong-joo;Lee, Jeong-yim
    • Fashion & Textile Research Journal
    • /
    • v.20 no.5
    • /
    • pp.556-568
    • /
    • 2018
  • In this study, we surveyed the current status and sizing system of the custom dress shirts sold through online shopping, compared with the sizing system of the ready-made dress shirts. We tried to collect the information needed to make the well fitted dress shirts for middle-aged men from this study. The 17 online custom dress shirt brands were selected and the sales type, sales price, design options and size options of each brand were analyzed. The sizing systems of online custom dress shirt brands were compared with the sizing system of the 10 ready made dress shirt brands. The result showed that online custom dress shirts brands offered a variety of design options and size options to meet the consumers' individuality, taste and demand for good fit. In the ready-made brands, all 10 brands were using the same size notation system. In the same size designation, the difference in product size among the ready-made brands showed a tendency to be smaller than the online custom brands. The online custom brands had the different size notation system among brands. The size notation, the number of size designation and the size interval were different for each brand. Also, in the online custom brands, the product size among brands differed from each other in the same size designation. Therefore, the standardized size information and sizing system for middle-aged men that could be used as criteria when making the product size and pattern design in online custom brands were needed.

A Study on the Effect of Specimen Size using Resistivity Estimation Model (비저항추정모델을 이용한 실험체 크기의 영향에 대한 연구)

  • Lim, Young-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.113-119
    • /
    • 2019
  • This study aims at the analysis using the Resistivity Estimation Model (REM) to examine the effect of specimen size on the measurement of electrical resistivity. In the experiment, specimens of concrete were fabricated and the apparent resistivity was measured for each electrode interval. The apparent resistivity measured was found to be distorted in the apparent resistivity as the specimen size became smaller and closer to the outside (edge). As a result of comparing the experimental and analysis values, it is expected that REM can be used to examine the effect of the size of the specimen.