• Title/Summary/Keyword: Size distribution measurement

Search Result 516, Processing Time 0.03 seconds

A Study on the Suggestion for the Revision of Standard Sizing System for Infant Clothing (유아복의 KS 치수체계 개정을 위한 제안 연구)

  • Jung, Myoung Sook;Suh, Chu Yeon;Lee, Jin Hee
    • Fashion & Textile Research Journal
    • /
    • v.16 no.1
    • /
    • pp.118-127
    • /
    • 2014
  • This study proposed a revision of standard sizing system for infant clothing to provide exact information for consumers and manufacturers. The size designation was set up by compensating the defect of existing system. Basic body measurement and reference body measurement were analysed according to size designation. The ages of the infants ranged from 0 to 36 month in accordance with safety standard of KC Self-Regularity Safety Confirmation. The results are as follows: Size designation for infant clothing was based on height that was basic body measurement. Chest girth, waist girth, head girth, arm length, foot length and weight were also analysed according to age of the month. It was proposed that height could be written alone and height with age of month did together for size designation. Size intervals of basic and reference body measurements were fixed as follows: size intervals are 5 cm in height, 2 cm in chest girth, 2 cm in waist girth, 1 cm in head girth, 2 cm in arm length, 0.5 cm in foot length and 2 kg in weight. The distributions of height and chest girth showed normal distributions. As height was taller, chest girth was also bigger. But the distribution of waist girth didn't show remarkable change with age of month. The distributions of arm length and weight showed remarkable difference with growth in 0~9 months, but the amount of growth variation got less in 12~18 months.

The effect of particle size on the determinability of maize composition in reflection mode.

  • MVaradi, Maria;Turza, Sandor
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1129-1129
    • /
    • 2001
  • Maize, in Hungary, is the fodder-plant grown in the biggest quantity. It is not only used as a fodder but other products such as iso-sugar are made from it, too. The quality of the fodder and the produce is largely dependent on the composition of the supplied maize to the processing site. The examination of quality parameters besides conventional methods are investigated and measured by NIR spectroscopy on a routine basis. The investigated parameters are the following: water, total protein, starch and oil content. The accuracy and precision of determining these parameters we, apart from the wet chemical methods, influenced by sample preparation to a great extent. One of the main features of this is the sample particle size and its distribution across the sample. The uneven distribution of particle size negatively influences the measurement accuracy, decreases model robustness and prediction ability. With these in mind the aim of our experiment was to investigate the effect of particle size on the accuracy of maize composition determination using reflection measurement setup. In addition, we tested different spectrum transformations, which are suitable for canceling this effect. In our experiment 47 samples were analyzed with three different mesh sizes (1.5mm, 1.8mm and 2mm). The results of our findings are presented here.

  • PDF

Formation of Silicon Particles Using $SiH_4$ pyrolysis at atmospheric pressure (상압에서 열분해법을 이용한 실리콘 입자 제조)

  • Woo, Dae-Kwang;Nam, Kyung-Tag;Kim, Young-Gil;Kim, Kwang-Su;Kang, Yun-Ho;Kim, Tae-Sung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.126-129
    • /
    • 2007
  • The particle formation using pyrolysis has many advantages over other particle manufacturing techniques. The particles by pyrolysis have relatively uniform size and chemical composition. Also, we can easily produce high purity particles. Thus, we studied the formation of silicon particles by pyrolysis of 50% $SiH_4$ gas diluted in Ar gas. A pyrolysis furnace was used for the thermal decomposition of $SiH_4$ gas at $800^{\circ}C$ and atmospheric pressure. The aerosol flow from furnace is separated into two ways. The one is to the Scanning Mobility Particle Sizer (SMPS) for particle size distribution measurement and the other is to the particle deposition system. The produced silicon particles are deposited on the wafer in the deposition chamber. SEM measurement was used to compare the particle size distribution results from the SMPS. Depending on the experimental conditions, particles of high concentration in the $30\sim80$ nm size range were generated.

  • PDF

Measurement of Focal Spot Size of Heavy Loaded X-ray Tubes (X선관의 실효초점 측정에 관한 고찰)

  • Chang, Kwang-Hyun;Lim, Oh-Soo;Kim, Hyung-Kee;Song, Chang-Wook;Cheung, Kyung-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.101-106
    • /
    • 1993
  • In order to assure safety of both patient and operator, and to provide uniform quality radiographs, it is necessary to perform periodic calibration of diagnostic X-ray equipment. A basic parameter of diagnostic equipment's and its image sharpness is the size(and shape the energy distribution) of the focal spot as viewed along the central X-ray beam. This size determines the resolution possible with the equipment and also determines the heat characteristics of an anode. A fine focus tube gives high resolution but causes high local heating of target. In past, the pin-hole and star pattern image measurement for evaluation of resolution have been widely used, but it produced blurring and inaccuracy of image. So newly inverted Ug-meter has advantage in more convenient measurement method and less out-put bias than other image measurement. The authors intended to compare measured focal size between Ug-meter and focal spot test tool, changed state from setting to now of units.

  • PDF

Classification of Size Specifications for the Ready-made Jacket-from 28 years to 35 on the Korean adult male- (신사복 상의제작을 위한 사이즈스팩의 분류-28세에서 35세 우리나라 남성을 대상으로-)

  • 김구자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.8
    • /
    • pp.1090-1098
    • /
    • 1998
  • The purpose of this study was to classify size specifications of the Korean adult male for the men's ready-made garments, especially jacket and dress shirts. By the stratified sampling method, data were collected by the real anthropometric measurement and by the photo-graphic sources. Sample size was 532 subjects as the sample and their age range was from 28 to 35 years old. 66 variables from the direct anthropometric data in total were applied to analyze. ANOVA in SPSS WIN package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. This study was performed to classify size specifications by the control dimensions and at the same interval of KS-K. The drop values of 15, 12 and 9 have the high coverage rate of 26.00%, 24.29% and 21.06% respectively and are composed of the majority of 71.35% of the subjects. According to the drop values, size specifications and distribution of control and reference dimensions are predicted. About 52.12% of the expected frequency distribution without stature were covered by 12 size specifications.

  • PDF

Measurement of Spray Distribution of Swirl Injector by Tomography Method at High Pressure Condition (토모그래피 기법을 이용한 고압 조건에서의 스월 분사기의 분무 분포 계측)

  • Park, Gu-Jeong;Cho, Seong-Ho;Chung, Jae-Mook;Kim, Tae-Sung;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.5
    • /
    • pp.66-71
    • /
    • 2011
  • The spray distribution at high pressure condition was measured by the Tomography method. The constructed spray distribution was compared with the images by Indirect Photography method so that the spray size confirmed and took the boundary of the distribution. It confirmed that the Tomography applies to construct the distribution at high pressure.

Measurement of Spray Distribution of Swirl Injector by Tomography method (토모그래피 기법을 이용한 스월 인젝터의 분무 분포 계측)

  • Park, Gu-Jeong;Cho, Seong-Ho;Chung, Jae-Mook;Kim, Tae-Sung;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.39-44
    • /
    • 2011
  • This study constructed the spray distribution by the Tomography method at high pressure condition. The constructed spray distribution was compared with the images by Indirect Photography method so that the spray size was confirmed and took the boundary of the distribution. It was confirmed that the Tomography applies to construct the distribution at high pressure.

  • PDF

Measurement of Welding Residual Stress in a 25-mm Thick Butt Joint using Inherent Strain Method (고유변형도법에 의한 두께 25mm 맞대기용접부의 두께방향의 잔류응력측정)

  • Park, Jeong-Ung;An, Gyu-Baek;Woo, Wanchuck;Heo, Seung-Min
    • Journal of Welding and Joining
    • /
    • v.31 no.4
    • /
    • pp.67-72
    • /
    • 2013
  • Overlay welding is carried out to improve the corrosion resistance, wear resistance and heat resistance on the surface of the chemical plant and steelmaking plant structures. In overlay welding, control of the bead size and the temperature distribution of weldment are particularly important because that is directly connected to the improvement of quality and productivity. The aim of this study is to model the welding heat source that is very useful to analyze the bead size and temperature distribution of weldment. To find the welding heat source model, numerical analyses are performed by using FE software MSC-marc.

Non-contact critical current measurement of superconducting coated conductor using Hall Probe (Hall Probe를 이용한 초전도선재의 비접촉 임계전류 측정 방법)

  • Kim, Ho-Sup;Oh, Sang-Soo;Lee, Nam-Jin;Ha, Dong-Woo;Baik, Seung-Kyu;Ko, Rock-Kil;Ha, Hong-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.12-12
    • /
    • 2010
  • The hall probe measurement system was used to measure the critical current distribution of superconducting coated conductor. The system consists of reel to reel moving apparatus, 7 array hall probe, a rotary encoder and permanent magnet. The magnetic field profile across the width of superconducting coated conductor using Bean's critical state model was calculated. The effect of various parameters of the formulas on the magnetic field distribution and the effect of shape and size of artificial defects, which were formed on the surface of SmBa2Cu3O7-d(SmBCO) coated conductor using laser marking system, on the hall probe magnetic field signal of the hall probe measurement system was investigated.

  • PDF