• 제목/요약/키워드: Size deviation

검색결과 699건 처리시간 0.029초

한국성우(韓國成牛)의 혈액학치(血液學値) 및 혈액화학치(血液化學値)에 관한 연구(硏究) 제1보(第一報) 한국성우(韓國成牛)의 혈액학치(血液學値)에 관한 연구(硏究) (Studies on the Hematology and Blood Chemistry of Korean Cattle Part I. Studies on the Hematology of Korean Cattle)

  • 정창국
    • 대한수의학회지
    • /
    • 제5권1호
    • /
    • pp.61-96
    • /
    • 1965
  • Observations were made on the blood picture of total 196 heads of healthy Korean cattles, including 98 males and 98 females in the purpose of determination of hematological values and its sex difference, and seasonal variations during one year period from December 1963 to November 1964. The blood sampling were scheduled by random in four different seasons and the sample size of both sex included in each season were designated to be same size. The ranges, averages or mean values of the erythrocytes, hemoglobin, hematocrit, mean corpuscular hemoglobin concentration, total white blood cell count and differential count were determined in this studies and their respective standard deviation, standard error of means, sex defferences and seasonal variations were as follows; 1. The erythrocyte count of male showed a range of $5.0{\times}10^6/c.mm$ to $8.75{\times}10^6/c.mm$ with a mean of $6.5{\pm}0.096{\times}10^6/c.mm$. Female showed a range of $5.0{\times}10^6/c.mm$ to $8.30{\times}10^6/c.mm$, with a mean of 6. $131{\pm}0.078{\times}10^6/c.mm$. There was a highly significant sex difference and seasomal variation was not found to be significant. 2. The hemoglobin value of male showed a range of 9.0g/100cc. to 14.5g/100cc. with a mean of $11.074{\pm}0.143g/100cc$. Female showed a range of 9.0g/100cc to 13.0g/100cc. with a mean of $10.745{\pm}0.034g/100cc$. There was a highly significant sex difference and seasonal variation was not found to be significant. 3. The hematocrit value of male showed a range of 28% to 45% and with a mean of $34.867{\pm}0.468%$. Female showed a range of 28% to 42% with a mean of $32.888{\pm}0.322%$. There was a highly significant sex difference and seasonal variation was not found to be significant. 4. The mean corpuscular hemoglobin of male showed a range of 14.4rr. to 19.6rr. with a mean of $17.1{\pm}0.112rr$. Female showed a range of 14.7rr. to 19.5rr. with a mean of $17.6{\pm}0.113rr$. 5. The mean corpusular volume of male showed a range of $42.5{\mu}^3$ to $62.2{\mu}^3$ with a mean of $53.9{\pm}0.419{\mu}^3$, Female showed a range of $44.2{\mu}^3$ to $60.0{\mu}^3$ with a mean of $53.8{\pm}0.375{\mu}^3$. 6. The mean corpuscular hemoglobin concentration of male showed a range of 28.1 % to 34.9% with a mean of $31.4{\pm}0.161%$. Female showed a range of 28.0% to 34.9% with a mean of $30.9{\pm}0.169%$. 7. The total leucocyte count of male showed a range of 4,000/c.mm to 13,100/c.mm. with a mean of $9,338{\pm}218.23/c.mm$. Female showed a range of 4,000/c.mm. to 14,000/c.mm. with a mean of $9,338{\pm}235.90/c.mm$. Six difference was not found to be significant and there was a highly significant seasonal variation. 8. The differential count of male, the means of neutrophil, stab, segmented cell, Iymphocyte, monocyte, eosinophil and basophil were $31.173{\pm}0.570%$, 0.3%. $30.867{\pm}0.564%$, $55.112{\pm}0.603%$, $3.745{\pm}0.082%$, $9.867{\pm}0.422%$ and 0.14% rspectively. Female showed means of $31.010{\pm}0.572%$, 0.2%, $30.806{\pm}0.569%$, $53.929{\pm}0.634%$, $4.082{\pm}0.109%$, $10.908{\pm}0.503%$ and 0.12% respectively. There were significant sex differences in monocyte and highly significant sex difference in eosinophil, and seasonal variation were found to be highly significant in neutrophil, monocyte and eosinophil. 9. Hematological comparison made between cattles infested with so called "small type piroplasma" and non-infested group. The result of investigation showed no significant difference upon the red blood cell, hemoglobin and hematocrit values between lighty infested group and non-infested group. 10. Age distribution of test group in this study ranged from 2 years to 6 years in both sex and their average age were $4.45{\pm}0.114$(male) and $4.50{\pm}0.116$(female). There found to be no significant sex difference and seasonal variations in the age of test group.

  • PDF

단일집진법(單一集塵法)에 의(依)한 라돈 붕괴생성물(崩壞生成物)의 농도측정(濃度測定) (Measurement of Radon Daughters' Radioactivities by Using Single Filtering Method)

  • 장시영;노성기;홍종숙
    • Journal of Radiation Protection and Research
    • /
    • 제6권1호
    • /
    • pp.25-30
    • /
    • 1981
  • 단일집진법(單一集塵法)을 써서 공기부유진중(空氣浮游塵中)에 존재(存在)하는 라돈 붕괴생성물(崩壞生成物), 즉, RaA, RaB 및 RaC 의 방사능(放射能)(또는 농도(濃度))을 측정(測定)하였다. 이것은 단일집진장치(單一集塵裝置)를 이용하여 평균공격(平均孔隔)(mean pore size)이 $0.8{\mu}m$인 membrane 노지(瀘紙)에 채취(採取)한 시료(試料)의 전(全) 알파방사능(放射能)을 시차별(時差別)로 측정(測定)한 후 그 결과(結果)로부터 라돈 붕괴생성물(崩壞生成物)의 농도(濃度)를 Ci 또는 WL(working level) 단위(單位)로 산출(算出)하는 방법(方法)이다. 여기서는 농도외(濃度外)에도 농도치(濃度値)의 표준편차(標準偏差) 및 라돈 붕괴생성물(崩壞生成物)의 방사평형상태(放射平衡狀態)를 나타내는 방사평형인자(放射平衡因子)와 방사평형비(放射平衡比)를 구(求)하였다. Ci 및 WL단위(單位)로 주어진 라돈 붕괴생성물(崩壞生成物)의 농도(濃度)는 실험기간중(實驗期間中) 각각 $0.30{\sim}2.36pCi/l$$0.89{\times}10^{-3}{\sim}6.57{\times}10^{-3}WL$로서 시간적(時間的) 요동이 심하였는데 대개 하루중(中) 오전(午前)에 높고 오후(午後)에 낮은 현상을 보여 주었다. RaA, RaB 및 RaC의 농도산출(濃度算出)에 따른 표준편차(標準偏差)는 각각 ${\pm}57.75%,\;{\pm}22.32%$${\pm}31.29%$였으며 방사평형인자(放射平衡因子)는 평균(平均) 0.322였다. 그리고 RaA를 모핵종(母核種)으로 가정(假定)했을 때 각핵종간(各核種間)의 방사평형비(放射平衡比)는 대개 $C_1>C_2>C_3$인 것으로 나타났다. 여기서 $C_1,\;C_2$$C_3$는 각각 RaA, RaB 및 RaC의 농도(濃度)를 나타낸다.

  • PDF

3T Multi Voxel Spectroscopy에서 SENSE와 NEX 변화에 따른 정상인 뇌 대사물질 변화 분석 (Alteration Analysis of Normal Human Brain Metabolites with Variation of SENSE and NEX in 3T Multi Voxel Spectroscopy)

  • 성열훈;임재동;이재현;조성봉;우동철;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.256-262
    • /
    • 2008
  • 자기공명분광법(magnetic resonance spectroscopy: MRS)은 인체내 대사물질을 정량분석하여 병변의 조기진단 및 정밀진단에 도움을 주고 있으며, 최근 임상에 이용되고 있는 자기공명분광법은 single voxel spectroscopy (SVS) 기법과 multi voxel spectroscopy (MVS) 기법이 있다. 본 연구에서는 SENSE와 NEX를 변화시킨 multi voxel spectroscopy (MVS)의 데이터와 기존 single voxel spectroscopy (SVS)의 데이터를 비교 분석하여, 각각의 데이터의 유의성 차이를 평가하고자 하였다. 정상 성인 지원자 13명(남자: 5명, 여자: 8명, 평균 41세, 표준편차 11.65세)을 대상으로 chemical shift image (CSI)를 이용한 MVS검사를 시행하였다. 장비는 3.0T Achieva Release Version 2.1 (Philips Medical System, Netherland)을 이용하였고, 8 channel head coil을 사용하여 brain thalamus 부위에서 CSI spectrum을 1 slice 획득하였다. Scan parameter로는 FOV (field of view): $230{\times}184mm^2$, TR (time to repetition): 2000 msec, TE (time to echo): 288 msec, matrix: $15{\times}12$, VOI(view of interest): $110{\times}110mm^2$, voxel size: $15{\times}15{\times}15mm^3$로 하였다. SENSE factor (S)와 NEX (N)는 S1*N1, S2*N1, S2*N2, S3*N2로 변화하여 스펙트럼을 획득하였고, 각 scan time은 5분 54초, 3분 32초, 6분 20초, 4분 20초였다. 얻은 모든 MRS 데이터는 jMRUI 3.0 Version 프로그램에서 분석하였고, SENSE factor와 NEX를 변화시켜 얻은 MVS data 그룹들이 정상 성인 뇌 대사물질의 변화에 영향을 주는지 검증하기 위해 그룹 간에 ANOVA분석을 실행하여 P 값이 0.05보다 크게 나오면 그룹들 사이에 유의한 차이가 없다고 분석하였다. NAA/Cr과 Cho/Cr의 상대적 비율은 MV와 SVS사이에서는 유의한 차이가 없었다. 즉, SENSE factor와 NEX를 변화시켜 얻은 MVS data에서 정상 성인 뇌조직의 대사물질의 변화를 관찰한 결과, S1*N1의 NAA/Cr은 $1.45{\pm}0.03$, Cho/Cr은 $0.88{\pm}0.03$이고, S2*N1의 NAA/Cr은 $1.44{\pm}0.03$, Cho/Cr은 $0.87{\pm}0.05$, S2*N2의 NAA/Cr은 $1.43{\pm}0.02$, Cho/Cr은 $0.87{\pm}0.04$이며, S3*N2의 NAA/Cr은 $1.45{\pm}0.03$, Cho/Cr은 $0.87{\pm}0.03$으로 나타났다(F-value : 1.37, D.F : 3, P-value : 0.262). 그러나 데이터의 질을 측정하기 위한 MVS 데이터의 NAA Peak line-width는 SVS 데이터의 NAA Peak line-width 보다 약 3배 정도 넓었다. 본 연구에서는 MVS에서 SENSE factor와 NEX 값을 다양하게 변화시킨 MVS의 데이터와 SVS의 데이터가 큰 차이가 없음을 확인하였다. 즉, 어는 특정 부위의 뇌 조직의 대사물질은 MVS와 SVS 기법 모두 큰 차이가 없음을 확인할 수 있었다. 그러므로 MVS는 SVS보다 광범한 부위를 짧은 시간 안에 검사할 수 있으므로 매우 유용한 방법이라고 사료된다.

  • PDF

농산물 소매유통환경 변화에 따른 국내 산지유통조직 개선방안에 관한 연구: 조직화·규모화·전문화를 중심으로 (A Study 0n the Improvement of the domestic in producing area organizations According to the change retail environment: Focused on organized, scaled, Specialization.)

  • 김대윤
    • 산경연구논집
    • /
    • 제2권2호
    • /
    • pp.5-14
    • /
    • 2011
  • 1996년도의 유통시장개방을 계기로 소매유통 환경이 급변하기 시작하였으며, 이러한 소매유통 환경변화에 대한 대응력을 강화하기 위해 조직화를 통한 규모화가 산지의 중요한 과제로 대두되고 있다. 이에 산지에서는 여건변화에 대응하기 위하여 소규모 개별농가가 조직화를 통해 전문화·대규모화 되어 가고 있고, 품목별·지역별로 특화되어 가는 양상을 보이고 있다. 하지만 소비지 시장에 대한 경쟁력 강화라는 관점에서는 여전히 문제점을 보이고 있는 것이 사실이다. 이러한 문제점의 가장 대표적인 경우가 시장대응상의 산지유통조직의 조직화·규모화 문제이다. 본 연구에서는 선행연구들을 통한 농산물 유통환경 변화에 따른 산지 조직화 배경 및 필요성, 국내 산지유통조직의 현황 및 문제점, 국내·외 산지유통조직 우수사례를 살펴보고, 조직화·규모화를 중심으로 향후 산지유통조직 경쟁력 제고방안을 위한 개선방안에 대해 제시하였다. 연구 결과, 농산물 소매유통환경 변화에 따라 산지유통조직의 경쟁력을 제고하기 위한 개선방안으로 1) 원물수집 체계 다양화를 통한 가동률 향상 및 조직화 강화, 2) 전문화된 품목의 광역연합마케팅 추구를 통한 규모화 실현, 3) 국외 산지유통조직 우수사례인 프랑스 "브레따뉴 청과물 경제위원회"와 같은 관리 운영조직 설치 및 운영, 4) 국내에 적합한 산지유통조직모델 개발을 위한 지원체계 확립 등의 4가지를 제시하였다. 특히 국내 산지의 경우 산지조직화·규모화에 성공한 각종 사례분석을 통해, 조직적 규모화의 과정 속에서 생겨나는 각종 어려움과 그에 대한 극복방식 등을 일반화 시켜가는 노력이 요구된다.

  • PDF

"감자에 대한 항생제(抗生劑) 피마리신의 통계적(統計的) 효과(效果) 분석(分析)" (INVESTIGATION OF THE EFFECT OF AN ANTIBIOTIC "P" ON POTATOES)

  • 김종훈
    • 품질경영학회지
    • /
    • 제5권2호
    • /
    • pp.59-120
    • /
    • 1977
  • An antibiotic 'P', which is one of the products of the Gist Brocades N. V. is being tested by its research department as fungicide on seed-potatoes. For this testing they designed experiments, with two control groups, one competitor's product, eight formulations of the antibiotic to be tested in different concentrations and one mercury treatment which can not be used in practice. The treated potatoes were planted in three different regions, where bifferent conditions prevail. After several months the harvested potatoes are divided in groups according to their diameter, potato illness is analysed and counted. These data were summarised in percentage and given to us for Analysis. We approached and analysed the data by following methods: a. Computation of the mean and standard deviation of the percenage of good results in each size group and treatment. b. Computation of the experimental errors by substraction of each treatment mean from observed data. c. Description of the frequency table, plotting of a histogram and a normal curve on same graph to check normality. d. Test of normality paper and chi-sqeare test to check the goodness of fit to a normal curve. e. Test for homogeneity of variance in each treatment with the Cochran's test and Hartley's test. f. Analysis of Variance for testing the means by one way classifications. g. Drawing of graphs with upper and lower confidence limits to show the effect of different treatments. h. T-test and F-test to two Control mean and variance for making one control of Dunnett's test. i. Dunnett's Test and calculations for numerical comarision of different treatments wth one control. In region R, where the potatoes were planted, it was this year very dry and rather bad conditions to grow potatoes prevailed during the experimental period. The results of this investigation show us that treatment No.2, 3 and 4 are significantly different from other treatments and control groups (none treated, just like natural state). Treatment no.2 is the useless mercury formulation. So only No. 3 and 4, which have high concentrations of antibiotic 'P', gave a good effect to the potatoes. As well as the competitors product, middle and low concentrated formulations are not significantly different from control gro-ups of every size. In region w, where the potatoes got the same treatments as in region R, prevailed better weather conditions and was enough water obtainable from the lake. The results in this region showed that treatment No. 2, 3, 4, and 5 are Significantly different from other treatments and the control groups. Again No.2 is the mercury treatmentin this investigation. Not only high concentrated formulation of antibiotic 'P', but also the competitor's poroduct gave good results. But, the effect of 'P', was better than the competitors porduct. In region G, where the potatoes got the same treatments as in the regions R and w. and the climate conditions were equal to region R, the results showed that most of the treatments are not significantly different from the control groups. Only treatment no. 3 was a little bit different from the others. but not Significantly different. It seems to us that the difference between the results in the three regions was caused by certain conditions like, the nature of the soil the degres of moisture and hours of sunshine, but we are not sure of that. As a conclusion, we can say that antibiotic 'P' has a good effect on potatoes, but in most investigations a rather high concentration of 'P' was required in formulations.

  • PDF

복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성 (Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera)

  • 이원호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권3호
    • /
    • pp.287-292
    • /
    • 2008
  • 방사선 반응에서의 위치정보는 방사선 선원의 영상을 재구성하는데 있어서 매우 중요한 기본정보이다. 이에 대부분의 위치 검출 기술을 이용하여 검출기안에서의 일어난 단일 반응의 위치정보를 알아낼 수 있다. 그러나 섬광체 안에서의 다중산란의 경우 각각의 산란위치를 개별적으로 측정할 수 없고 여러 산란위치의 평균만이 구해질 수 있어서 측정된 방사능의 위치정보에 불확실성이 존재하게 된다. 이 논문에서는 이러한 다중산란에 따른 위치 불확실성을 몬테카를로 시뮬레이션으로 계산하였다. 시뮬레이션 모델은 복합 집속 카메라에 사용된 $50{\times}50{\times}5mm\;LaCl_3$(Ce) 섬광체(pixel크기는 $2{\times}2{\times}5mm$)이다. 복합 집속 카메라는 광전효과와 컴프턴 산란 모두에서 정보를 얻으므로 방사선의 반응에서 부분에너지만 (검출기에) 검출되는 경우와 모든 에너지가 검출 되는 경우를 나누어 위치 불확실성을 계산하였다. 부분에너지만 검출되는 경우 (PED) 위치의 표준편차는 $1{\sim}2mm$ 미만으로 다중산란에 의한 불확실성이 크지 않다는 것을 알 수 있다. PED의 경우 다중산란의 영향이 크지 않으므로 이러한 다중산란은 컴프턴 카메라의 성능에 큰 영향을 미치지 않는다는 것을 알 수 있다. 그러나 모든 에너지가 검출되는 경우 (FED), 122keV입사방사선의 경우를 제외하면, 그 위치의 표준편차가 1차 검출기의 pixel크기에 2배에 달한다. 그러므로 복합 집속 카메라의 코드화된 마스크를 설계하는데 있어 재구성된 영상의 잡음을 방지하기 위해 다중산란에 의한 표준편차가 고려되어야 한다. 모든 입사 방사선에너지에 대하여 FED에 의한 위치 불확실성은 PED에 의한 것 보다 크며 PED 대 FED의 비는 입사방사선의 에너지가 증가함에 따라서 커진다. PED와 FED의 경우 모두 위치의 불확실성이 입사방사선의 에너지에 따라 달라졌다.

  • PDF

전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교 (Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus)

  • 김병수;박주영;박병석;송용민;박병수;송기원
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.163-170
    • /
    • 2014
  • 목 적 : 표재성 종양 치료를 위하여 선택한 전자선은 bolus와 동시에 사용할 경우 표면선량에 급격한 변화를 보이게 되며 이는 치료결과의 중요한 변수로 작용할 수 있다. 이에 본 논문에서는 전자선 치료에서 bolus가 적용될 경우 표면선량을 좌우할 수 있는 4 가지 변수에 따른 치료계획시스템(Treatment Planning System, TPS)의 표면선량 계산 값과 실제 측정값을 비교 분석하였다. 대상 및 방법 : 치료계획시스템(Pinnacle 9.2, philips, USA)과 실제 측정값을 비교하기 위하여 실제 치료 시 주로 발생되는 4가지 변수(A: bolus 두께 - 3, 5, 10 mm, B: 조사야 크기 - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: 에너지 - 6, 9, 12 MeV, D: 겐트리 각도 - 0, $15^{\circ}$)를 설정하였다. 16 cm 두께의 solid water phantom을 이용하여 bolus(Action Products, USA) 없이 전산화단층촬영(lightspeed ultra 16, General Electric, USA)을 시행하였고 치료 계획은 TPS 상에서 각각 3, 5, 10 mm bolus를 생성하여 A, B, C, D를 조합한 총 54개의 beam으로 계획하였다. 이때 SSD 100 cm, 300 MU를 조사하였고 TPS와 실제 측정값을 비교 분석하기 위해 EBT3 film(International Specialty Products, NJ, USA)을 이용해 iso-center에 위치시켜 2회 반복 측정하였다. 측정된 film은 디지털 평판 스캐너(Expression 10000XL, EPSON, USA)와 선량 농도 분석시스템(Complete Version 6.1, RIT, USA)을 사용하여 각각의 평균값과 표준편차 값으로 분석하였다. 결 과 : bolus 두께에 따른 값은 3, 5, 10 mm에서 실제 측정된 값이 TPS의 계산 값보다 각각 101.41%, 99.58%, 101.28%, 표준편차는 각각 0.0219, 0.0115, 0.0190 으로 나타났다. 조사야 크기에 따른 실제 측정값은 $6{\time}6$, $10{\time}10$, $15{\time}15cm2$ 각각 계산 값에 비해 99.63%, 101.40%, 101.24%, 표준편차는 0.0138, 0.0176, 0.0220 으로 나타났다. 에너지에 따른 값은 상대적으로 6, 9, 12 MeV 각각 99.72%, 100.60%, 101.96%, 표준편차는 0.0200, 0.0160, 0.0164로 나타났다. 빔 각도에 따른 실제 측정값은 계산된 값에 비하여 0, $15^{\circ}$에서 각각 100.45%, 101.07%, 표준편차는 0.0199, 0.0190 으로써 $15^{\circ}$에서 $0^{\circ}$보다 0.62% 높게 측정되었다. 결 론 : 본 논문에서 사용한 변수에 따른 계산 값과 측정값을 분석한 결과 5 mm bolus, $6{\time}6cm2$ 조사야, 저 에너지 전자선, $0^{\circ}$ 겐트리 각도에서 TPS로 계산한 값이 측정값에 더 가까웠지만 다른 변수를 적용한 비교에서도 최대 2% 오차범위 내에 포함되는 결과를 보였다. 전자선과 bolus를 동시에 사용하는 경우 본 논문에서 선택된 변수의 범위를 벗어난다면 각각의 변수에 따라 실제 측정값이 TPS와 달라질 수 있기 때문에 정확한 표면선량에 대한 QA를 반드시 실시해야 한다.

폐쇄성 수면무호흡 증후군과 일차성 불면증에서 심박동률 변이도 지수의 비교 (Comparison of Heart Rate Variability Indices between Obstructive Sleep Apnea Syndrome and Primary Insomnia)

  • 남지원;박두흠;유재학;유승호;하지현
    • 수면정신생리
    • /
    • 제19권2호
    • /
    • pp.68-76
    • /
    • 2012
  • 목 적: 수면 장애는 자율신경계의 변화를 유발하여 심혈관계에 영향을 준다. 일차성 불면증(primary insomnia, 이하 PI)은 수면부족 및 각성으로, 폐쇄성 수면무호흡 증후군(obstructive sleep apnea syndrome, 이하 OSAS)은 수면 중 빈번한 각성, 저산소증 등으로 교감신경계 항진을 유발한다. 이에 OSAS와 PI 사이에서 심박동률 변이도(heart rate variability, 이하 HRV) 분석을 통해 자율신경계의 변화 정도를 비교하고자 하였다. 방 법: 임상병력 및 야간수면다원검사(nocturnal polysomnography, 이하 NPSG)로 선택된 PI와 OSAS 전체 315 명의 대상자 중 OSAS는 무호흡-저호흡 지수(apnea-hypopnea index, 이하 AHI)에 따라서 경도, 중등도, 중증도 OSAS로 분류하여 PI를 포함하여 4개의 군으로 분류되었다. 이후 연령, 성별, 군간 개체수를 고려하여 최종적으로 110명의 대상자가 선택되었고, PI군(평균나이 41.50, 표준편차 13.16, AHI <5, n=20), 경도 OSAS군(평균나이 43.67, 표준편차 12.11, AHI 5~15, n=30), 중등도 OSAS군(평균나이 44.93, 표준편차 12.38, AHI 16~30, n=30), 중증도 OSAS군(평균 나이 45.87, 표준편차 12.44, AHI >30, n=30)의 4개 군으로 나누었다. 이후 NPSG를 통해 얻은 각 군의 HRV 지수 비교를 위하여 연령과 체질량지수(body weight index, BMI)를 공변량으로 하여 공분산분석(analysis of covariance, ANCOVA)를 실시한 후 사후분석으로 Sidak test를 실시하였다. 결 과: HRV 지수의 비교 결과 PI군과 경도, 중등도의 OSAS군 간에 유의한 차이는 없었다. 그러나 PI군과 중증도 OSAS군 사이에는 유의한 차이가 있었다. 군간비교에서 통계적으로 가장 현저한 차이를 보인 PI군과 중증도 OSAS군에서 HRV 지수 중 통계적으로 의미 있는 각각의 값은 다음과 같았다. Average RR interval은 $991.1{\pm}27.1$$875.8{\pm}22.0$ ms(p=0.016), standard deviation of NN interval(SDNN)은 $85.4{\pm}6.6$$112.8{\pm}5.4$ ms(p=0.022), SDNN index는 $57.5{\pm}5.2$$87.6{\pm}4.2$(p<0.001), total power는 $11893.5{\pm}1359.9$$8097.0{\pm}1107.2ms^2$(p=0.008), very low frequency(VLF)는 $7534.8{\pm}1120.1$$11883.8{\pm}912.0ms^2$(p=0.035), low frequency(LF)는 $2724.2{\pm}327.8$$4351.6{\pm}266.9ms^2$였다(p=0.003). 결 론: 본 연구에서는 PI군에 비해 중증도의 OSAS군에서 HRV 지수 중 교감신경계의 영향을 많이 받는 VLF, LF 등이 상승하는 양상을 보였고, 이를 통해 PI에 비해 중증도의 OSAS가 교감신경계 활동증가에 보다 더 큰 영향을 끼치는 것을 알 수 있었다.

16M-Color LTPS TFT-LCD 디스플레이 응용을 위한 1:12 MUX 기반의 1280-RGB $\times$ 800-Dot 드라이버 (A 1280-RGB $\times$ 800-Dot Driver based on 1:12 MUX for 16M-Color LTPS TFT-LCD Displays)

  • 김차동;한재열;김용우;송남진;하민우;이승훈
    • 대한전자공학회논문지SD
    • /
    • 제46권1호
    • /
    • pp.98-106
    • /
    • 2009
  • 본 논문에서는 ultra mobile PC (UMPC) 및 휴대용 기기 시스템 같이 고속으로 동작하며 고해상도 저전력 및 소면적을 동시에 요구하는 16M-color low temperature Poly silicon (LTPS) thin film transistor liquid crystal display (TFT-LCD) 응용을 위한 1:12 MUX 기반의 1280-RGB $\times$ 800-Dot 70.78mW 0.13um CMOS LCD driver IC (LDI) 를 제안한다. 제안하는 LDI는 저항 열 구조를 사용하여 고해상도에서 전력 소모 및 면적을 최적화하였으며 column driver는 LDI 전체 면적을 최소화하기 위해 하나의 column driver가 12개의 채널을 구동하는 1:12 MUX 구조로 설계하였다. 또한 신호전압이 rail-to-rail로 동작하는 조건에서 높은 전압 이득과 낮은 소비전력을 얻기 위해 class-AB 증폭기 구조를 사용하였으며 고화질을 구현하기 위해 오프 셋과 출력편차의 영향을 최소화하였다 한편, 최소한의 MOS 트랜지스터 소자로 구현된 온도 및 전원전압에 독립적인 기준 전류 발생기를 제안하였으며, 저전력 설계를 위하여 차세대 시제품 칩의 source driver에 적용 가능한 새로운 구조의 slew enhancement기법을 추가적으로 제안하였다. 제안하는 시제품 LDI는 0.13um CMOS 공정으로 제작되었으며, 측정된 source driver 출력 정착 시간은 high에서 low 및 low에서 high 각각 1.016us, 1.072us의 수준을 보이며, source driver출력 전압 편차는 최대 11mV를 보인다. 시제품 LDI의 칩 면적은 $12,203um{\times}1500um$이며 전력 소모는 1.5V/5.5V 전원 저압에서 70.78mW이다.

쐐기필터 사용에 따른 선량증가 영역에서 선량평가 (Dose Evaluation at The Build Up Region Using by Wedge Filter)

  • 김연래;문성공;서태석;정진범;김진영;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권4호
    • /
    • pp.341-348
    • /
    • 2014
  • 쐐기필터는 고선량 부분의 선량분포를 균등하게하기 위해서 사용된다. 금속쐐기필터와 기능강화 동적쐐기필터가 광자선과 상호 작용으로 표면과 선량강화영역 조사면내, 외에 선량변화를 평가하였다. 본 논문에서는 2차원적 조직등가물질로 공간 선량분포가 우수하고, 흡수선량에 따라 현상 없이 실시간으로 광학농도가 변하는 가프크로믹 EBT3 필름을 사용하여 선량평가를 실시하였다. 선형가속기 광자선 에너지는 6 MV, SSD 100 cm, 조사면 $10{\times}10cm^2$으로 고정하고 최대선량점에 400 cGy로 조사하였다. 선량분포는 열린 조사면과 $15^{\circ}$, $30^{\circ}$, 그리고 $45^{\circ}$ 금속쐐기필터와 기능강화 동적쐐기필터를 사용 하였을 때 비교 평가 하였다. $15^{\circ}$ 금속쐐기필터를 사용하면 조사면내 표면선량과 선량증가영역 선량은 기능강화 동적쐐기필터보다 증가하였다. $30^{\circ}$ 금속쐐기필터를 사용하면 조사면내 표면선량과 선량증가영역 선량은 기능강화 동적쐐기필터 보다 감소하였다. $45^{\circ}$ 금속쐐기필터를 사용하면 조사면내 표면선량과 선량증가영역 선량은 많은 차이로 감소하였다. 조사면 주변 반음영 영역에서는 두꺼운 방향은 증가하고 얇은 방향은 감소하였다. 선량분포를 변화하고자 하는 치료 부위에 금속쐐기필터를 적절히 사용하고 유방암 치료와 같이 표면과의 거리가 가까워지지 않으면 표면 및 선량증가영역 선량이 감소하리라 사료된다.