• Title/Summary/Keyword: Size Fit

Search Result 798, Processing Time 0.03 seconds

A Survey on the Actual Wearing Condition for the Improvement of Fit of Brassiere (브래지어의 맞음새 향상을 위한 착용실태 조사 -1924세대 소비자를 중심으로-)

  • Oh, Song-Yun;Choi, Hei-Sun;Yi, Kyong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.9_10 s.157
    • /
    • pp.1378-1388
    • /
    • 2006
  • We conducted a questionnaire survey of 481 Korean female college students and measured anthropometrically 2 girth of their bodies(bust, under bust girth) in order to understand the psychological needs about brassiere and the physical characteristics of consumers aged between 19 and 25(the 1924 generation). There were two major problems to be solved to improve the fit of brassiere in aspect of size. First, most brands for this age group aimed at product differentiation mainly on visual design not on brassiere size. According to the body measurements, the distribution of brassiere size had 6 sections '70AA, 70A, 70B, 75AA, 75A and 75B cups' showing a rate of 63.8% but most brands for this age group were producing '75A, 80A, 85A, 75B, 80B and 85B cups' showing a rate of 24.7%. Second, most subjects of this survey didn't know their own breast size and the sizing system of brassiere which are necessary in order to select the proper brassiere size. And most subjects were wearing a bigger size brassiere than their own body size even though one was in the range of '75A, 80A, 85A, 75B, 80B and 85B'. It might be possible that the dimensions of brassiere products in the market and the sizes indicated on the labels do not correspond. For increasing the consumer satisfaction it is necessary to adjust the production rate of brassiere sizes and to develop ergonomic brassiere products with proper dimensions and shapes for each brassiere size.

THE ANALYSIS OF INITIAL APICAL FILE SIZE BEFORE AND AFTER CORONAL FLARING (Coronal flaring 전, 후 초기근관장 파일크기의 분석)

  • Hwang, Ho-Keel;Park, Chan-Ho;Bae, Seong-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.64-71
    • /
    • 2003
  • The purpose of this study was to compare the initial apical file(IAF) first Ole that fits to the apex in each canal before and after early flaring to analyze if the size of file to fit to the apex would increase after flaring. Eighty anterior teeth with complete apical formation and patent foramens were selected. The samples were randomly divided into 4 groups(GG, OS, GT, PT Group) of 20 teeth each. A file was fit to the apex in each canal and that size recorded. Radicular flaring were completed using different types of instruments. After flaring a file was again fit to the apex in the same manner as before and its size recorded. The results of this study were as follows : 1. The mean diameter of IAF before flaring(file diameters in $mm{\times}10^{-2}$) was $19.81{\pm}8.32$ before and $25.94{\pm}9.21$ after(p<0.05). 2. The increase in diameter of IAF was approximately one file size for all groups. 3. Ranking of increasing diameter of IAF were GG>CT>OS>PT group. There was a statistically significant difference between before and after flaring(p<0.05). 4 Ranking of the time for flaring were GG>GT>OS>PT group. There was a statistically significant difference between GG group and other groups(p<0.05). 5. In the case without change of IAF diameter, they showed decrease in force after flaring when IAF was pulled out from root canal(p<0.05). This study suggested that early radicular flaring increases the file size that is snug at the apex, and awareness of that difference gives the clinician a better sense of canal size. Early flaring of the canal provides better apical size information and with this awareness, a better decision can be made concerning the appropriate final diameter needed for complete apical shaping.

A Study on Natural Frequency of Shrink Fit Shaft (열박음축의 고유진동수에 關한 硏究)

  • Yoo, Eun-Yul;Oh, Jae-Eung;Yim, Tong-Kyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.14-24
    • /
    • 1990
  • A Study is made on shrink fit shaft in which its part is modelled and spring stiffness per unit length is estimated, then obtained transfer matrix. Transfer matrix of shaft is found by Myklestad's method and natural frequency is found by shrink fit tolerance on shrink fit shaft, too. In order to verify effectiveness of shrink fit effect, hollow shaft of the same size is compared with shrink fit shaft which will verified on experiment. As a result of this study, the more shrink fit tolerance increases, the more spring stiffness per unit length increases. It is obvious from the above results that shrink fit shaft due to shrink fit tolerances decreases natural frequency.

  • PDF

Comparison of the marginal and internal fit of cores fabricated by Ni-Cr alloy(non-beryllium) and Co-Cr alloy (베릴륨이 함유되지 않은 니켈-크롬 합금 코어와 코발트-크롬 합금 코어의 적합도 비교평가)

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.353-359
    • /
    • 2012
  • Purpose: The aim of this study measured and compared the marginal and internal fit of metal cores with two base metal alloy (Ni-Cr alloy(non-beryllium), Co-Cr alloy). Methods: Maxillary right first molar abutment fabricated by titanium was prepared for this study. Impressions(10ea) were made from titanium model, and study models were poured with improved dental stone. Wax cores of twenty were prepared for burn-out and casting. Ten wax cores cast Ni-Cr alloy(non-Be), and finally ten cast Co-Cr alloy. Marginal and internal fit of cores was evaluated using silicone replica technique and digital microscope(x160). The data were statistically analyzed with the independent samples t-test (${\alpha}$ <.05). Results: Mean(standard deviation, SD) marginal and internal fit total size of Ni-Cr alloy(non-Be) group was $73.3(14.4){\mu}m$ and of Co-Cr alloy group $65.6(17.4){\mu}m$. The marginal and internal fit total size of Ni-Cr alloy group(non-Be) was statistically significantly greater than that of Co-Cr alloy group (P=.004). Conclusion: Co-Cr alloy cores in this study had a better marginal fit than Ni-Cr alloy(non-Be) cores.

A study on the development of the slim-fit tailored jacket prototype - Focused on the standard somatotype of women in their 30s - (슬림 핏 테일러드 재킷 원형 개발 연구 - 30대 여성 표준체형을 중심으로 -)

  • Jeong, JaeChul;Park, SunKyung;Uh, MiKyung
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.3
    • /
    • pp.454-467
    • /
    • 2015
  • Reflecting the consumer's desire to look young, the "down-aging" trend, which blurs the distinctions between age groups, is the latest craze in the fashion market. The popularity of this trend made brand identities similar, resulting in customers becoming more interested in segmented notions of fashion (in terms of the story, design, high-quality material, etc.) regarding the product, and in particular, focus has become oriented to the fitness to the human body. In this sense, the researcher aimed to develop the prototype of a slim-fit tailored jacket that fits the standard somatotypes of women in their 30s well. For the purpose of this research, slim-fit tailored jackets from existing brands were collected and analyzed, and a subsequent wearability test was conducted based on the standard somatotype of women in their 30s. The research patterns were prototype of the developed slim fit tailored jacket are bust size of 3.8 cm, waist of 7 cm, and hip size of 3.8 cm. Then the research patterns were selected to develop the prototype of a properly fitting slim-fit tailored jacket. As outlined above, the development of a slim-fit tailored jacket prototype for the standard somatotypes of women in their 30s was conducted by solving the fitness issues of existing brands in order to produce properly fitting jackets that satisfy consumers.

Lower Body Analyses and Pattern Development of Slim-fit Jeans for Upper Grade Elementary School Girls (학령 후기 여아의 하반신 체형 분석과 슬림핏 청바지 패턴 개발)

  • Kim, Hea Suk;Lee, Jeong Yim
    • Fashion & Textile Research Journal
    • /
    • v.23 no.4
    • /
    • pp.491-503
    • /
    • 2021
  • The purpose of this study is to develop a slim-fit jeans pattern that is suitable for the lower body of upper grade elementary school girls, who are beginning to show gender differences in body shape. Four age groups of two years each were considered for girls 7 to 14 years old. The mean and standard deviation of body measurements were calculated for each age group to analyze body shape variation, and hence the body characteristics of upper grade elementary school girls were identified. The high-frequency measurements of stature-waist circumference and waist circumference-hip circumference combinations were analyzed. In order to determine the size of each part of the jeans pattern and derive the drafting formula, the pattern sizes of brand A jeans, which had received a high score in the evaluation for ready-to-wear jeans(Kim & Lee, 2020), were used as the base criteria. In addition, the body sizes observed and calculated in the study were applied. Additionally, the requirements for better fit of ready-to-wear jeans, found in the survey on jeans wearing conditions and size dissatisfaction(Kim & Lee, 2019), were taken into consideration. Based on this research, a model set of jeans was prepared with the pattern developed and its fit evaluation was conducted. Thus, a slim-fit jeans pattern suitable for the lower body of upper grade elementary school girls was finalized. The pattern proposed in this study has excellent appearance and motion functionality, and is expected to contribute to reduce the fit dissatisfaction.

Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study

  • Lim, Joon-Ryul;Yoon, Tae-Hwan;Lee, Hwan-Mo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.66-71
    • /
    • 2021
  • Background: Extra-articular distal humerus locking plates (EADHPs) are precontoured anatomical plates widely used to repair distal humeral extra-articular diaphyseal fractures. However, EADHPs frequently cause distal protrusion and resulting skin discomfort. The purpose of this study was to predict the occurrence of anatomic fit mismatch. We hypothesized that the smaller the humerus size, the greater the anatomic fit mismatch with EADHP. Methods: Twenty humeri were analyzed in this study. Humeral length and distal humeral width were used as parameters of humeral size. Plate protrusion was measured between the EADHP distal tip and the distal humerus. We set the level of unacceptable EADHP anatomic fit mismatch as ≥10 mm plate protrusion. Results: A significant negative linear correlation was also confirmed between humeral size and plate protrusion, with a coefficient of determination of 0.477 for humeral length and 0.814 for distal humeral width. The cutoff value of humeral length to avoid ≥10 mm plate protrusion was 293.6 mm (sensitivity, 88.9%; specificity, 81.8%) and for distal humeral width was 60.5 mm (sensitivity, 100%; specificity, 81.8%). Conclusions: Anatomic fit mismatch in distal humeral fractures after EADHP fixation has a negative linear correlation with humeral length and distal humeral width. For patients with a distal humeral width <60.5 mm, ≥10 mm plate protrusion will occur when an EADHP is used, and an alternative implant or approach should be considered.

Estimation of the Number of Change-Points with Local Linear Fit

  • Kim, Jong-Tae;Choi, Hey-Mi
    • Journal of the Korean Data and Information Science Society
    • /
    • v.13 no.2
    • /
    • pp.251-260
    • /
    • 2002
  • The aim of this paper is to consider of detecting the location, the jump size and the number of change-points in regression functions by using the local linear fit which is one of nonparametric regression techniques. It is obtained the asymptotic properties of the change points and the jump sizes. and the correspondin grates of convergence for change-point estimators.

  • PDF

A Study on the Wearing and Preferences of Brassiere for Female College Students (여대생의 브래지어 착용과 선호에 관한 연구)

  • Pan, Hong-Yu;Choi, Jong-Myoung;Kweon, Soo-Ae;Sohn, Boo-Hyun
    • Korean Journal of Human Ecology
    • /
    • v.18 no.5
    • /
    • pp.1093-1101
    • /
    • 2009
  • To provide basic data to manufacture superior brassieres, we performed a survey on the wearing and buying habits, and preference of functions and materials of brassieres for 189 women subjects in their twenties. The results of this research are as follows; Style and size are the most important in purchasing brassieres. Flat breasted and sagging breasted subjects were dissatisfied in the fit of the upper cup. 70% of the subjects were ignorant of their brassiere size. Sagging breasted subjects were less satisfied with smoothness, softness, and weight when wearing their bras in comparison with the other types. Conical type breasts were common amongst women in their 20s. They are more likely to wear size 75A and 80A where the full bust girth is 10cm larger than the under-bust. They preferred demi cup brassieres with thin or moderate padding to full cup brassieres with thick padding. On the other hand, 56.8% of subjects wore brassieres all day. The subjects were dissatisfied with the slipping down of the shoulder straps. Large-breasted subjects were concerned more with dampness and the fit on the center front of the brassiere, and brassieres with too thick padding had a poor fit on the center front. Sports-brassieres which fit close to the skin and used stretchable fabric caused more itching and dampness and dissatisfaction in removal of the brassiere.

The Moderating Effects of Firm Size on the Relation of Environmental Uncertainty-Logistics Information Systems Fit and Logistics Performance (환경불확실성과 물류정보시스템 간의 적합성이 물류성과에 미치는 영향: 기업규모의 조절효과를 중심으로)

  • Lee, Changsoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.53-61
    • /
    • 2016
  • This paper investigates the moderating effect of firm size on the relationship between environmental uncertainty and logistics information systems fit and performance, and suggests logistics strategies that would help to achieve goals. Based on our empirical research results, the findings of this paper can be summarized as follows: First, firms with higher levels of harmony between environmental uncertainty and logistics information systems fit featured significantly better logistics performance than firms with lower levels of fit. Second, logistical performance can be maximized based on the firm size and the harmonization between environmental uncertainty and logistics information systems. The results of this study will assist firms align and focus on improving competitive strategies for logistics systems.