• Title/Summary/Keyword: Size Dimension

Search Result 825, Processing Time 0.023 seconds

Effects of Recycled Washwater on Pollutant Removal and Particle Characteristics during Coagulation (회수수가 응집공정의 오염물질 제거 및 입자특성에 미치는 영향)

  • 문병현;김승현;박미선;이향인;이강춘
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.955-960
    • /
    • 2002
  • The recycled washwater, which has different water quality and is produced about 5 to 20% of the total water volume treated, affects the unit operation of water treatment, especially coagulation process. However, the effects of recycled washwater on unit operation of water treatment have not been fully investigated. In this study, effects of recycled washwater on coagulation process were investigated to find the optimum coagulation condition by analyzing turbidity, $UV_{254}$, TOC removal efficiencies. In addition, effects of recycled washwater on residual Al after coagulation were studied by analyzing soluble and particulate Al. The size distribution and fractal dimension of coagulated also analyzed. The recycled washwater was lower pH than the raw water. And the recycled washwater had higher $UV_{254}$, TOC and residual Al concentration than the raw water. Residual Al concentration of recycled washwater was about 50 times higher than that of raw water. Optimum coagulant dosages on the blending recycled washwater and the raw water for turbidity, $UV_{254}$ and Al removal were lower than that on the raw water. However, TOC removal increased by increasing coagulant dosage. The size and fractal dimension of coagulated particle produced in the blending recycled washwater were larger, which imply faster settling velocity, than those produced in the raw water only.

Vascular Morphometric Changes During Tumor Growth and Chemotherapy in a Murine Mammary Tumor Model Using OCT Angiography: a Preliminary Study

  • Kim, Hoonsup;Eom, Tae Joong;Kim, Jae Gwan
    • Current Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.54-65
    • /
    • 2019
  • To develop a biomarker predicting tumor treatment efficacy is helpful to reduce time, medical expenditure, and efforts in oncology therapy. In clinics, microvessel density using immunohistochemistry has been proposed as an indicator that correlates with both tumor size and metastasis of cancer. In the preclinical study, we hypothesized that vascular morphometrics using optical coherence tomography angiography (OCTA) could be potential indicators to estimate the treatment efficacy of breast cancer. To verify this hypothesis, a 13762-MAT-B-III rat breast tumor was grown in a dorsal skinfold window chamber which was applied to a nude mouse, and the change in vascular morphology was longitudinally monitored during tumor growth and metronomic cyclophosphamide treatment. Based on the daily OCTA maximum intensity projection map, multiple vessel parameters (vessel skeleton density, vessel diameter index, fractal dimension, and lacunarity) were compared with the tumor size in no tumor, treated tumor, and untreated tumor cases. Although each case has only one animal, we found that the vessel skeleton density (VSD), vessel diameter index and fractal dimension (FD) tended to be positively correlated with tumor size while lacunarity showed a partially negative correlation. Moreover, we observed that the changes in the VSD and FD are prior to the morphological change of the tumor. This feasibility study would be helpful in evaluating the tumor vascular response to treatment in preclinical settings.

A Study on the Measurement of Korean Hand - Focusing on Glove & Hand Dimension - (한국인을 위한 장갑 패턴 고찰 (1) - 업체 조사를 통한 손계측 항목을 중심으로 -)

  • Ryu, Kyoung-Ok
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.5
    • /
    • pp.866-877
    • /
    • 2009
  • The purpose of this study was to develop the dimension of hand pattern-making for Korean glove. The glove pattern-making has difficult problem in combination of anthropometric and engineering aspects. In addition, existing dimension data are not enough for glove pattern-making. Therefore, to develop the dimension for glove this study comprehensive list of candidate hand data was reviewed and the manufacturers(career over the 15 years) were interviewed on the method of glove. The result of comparing between the structures in hand and existing glove pattern, there draw deduction from follows. Pattern-making for glove need size of hand length, thumb length, index finger length, middle finger length, ring finger length, hand circumference, thumb-ring finger circumference and maximum hand thickness.

  • PDF

A Study on the Body Proportion and Proportional Dimension Standards for Chinese Women - Focusing on the analysis of the high-frequence group -

  • Kim, Eun-Hee;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.10 no.6
    • /
    • pp.91-109
    • /
    • 2006
  • This study aims at strengthening the national competitiveness of Korea's clothing industry as it provides substantial information on the human body proportion and proportional dimension standards for Chinese women and improves the fitness of clothing, considering human proportion in the production of clothing products for export to China. This study selected by simple random sampling Chinese women in Beijing and Shanghai, China, whose age is between 19-50 from June 23 to August 7, 2004. The stature of the average Chinese woman belonging to the High Frequency group is 7.09 times as long as the length of the head. We developed the body proportional dimension standards with the same proportion with High-Frequence group. The basic size of proportional dimension standards for Chinese women has the stature of 159cm, (chest circumference)/2 of 42.8cm.

The Soil Particles Distributions and Fractal Dimension (흙의 입도분포와 플랙탈 차원)

  • Yu, Chan;Ahn, Sung-Yul;Lee, Chang-No;Baveye, Philippe C.
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.6
    • /
    • pp.25-32
    • /
    • 2002
  • The fractal dimension that was evaluated with soil components from the traditional particle-size distribution(PSD) curve was analyzed using the results of Wu et al.(1993) and Bittelli et al.(1999). In order to find the change of the variation of fractal dimension with the upper and lower limit, three limit values(200$\mu{m}$, 63$\mu{m}$, and 125$\mu{m}$) were chosen, and these results of fractal dimension analysis were compared to the result that was evaluated in the whole range of the soils. The results showed that it is possible to evaluate fractal dimension from the traditional PSD curve with the soil contents, and it showed that Bittelli et at.(1999)'s upper and lower limit value was more reasonable than Wu et al.(1993). Equations that were presented by Bittelli et at.(1999) also showed a good agreement with the analytical results in the silt domain.

Designation of Bodytypes and Size Specifications for Designing of the Ready-made Jacket (신사복 상의 설계를 위한 체형의 호칭 분류와 사이즈 스팩;36세에서 43세 우리나라 남성을 대상으로)

  • 김구자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.8
    • /
    • pp.1240-1247
    • /
    • 1999
  • The purpose of this study was to classify size specifications of Korean adult male for the men's ready-made garments especially jacket and dress shirts By the stratified sampling method data were collected by the real anthropometric measurement. Sample size was 263 subjects as the sample and their age range was from 36 to 43 years old 66 variables from the direct anthropometric data were applied to analyze. ANOVA is SPSSWIN 8.0 package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. This study was performed to classify size specificatios by the control dimensions. The drop values of 9,12 and 6 have the high coverage rate of 28.52% 23.44% respectively Obese body type ; H type HD type and HE type are composed of the majority of 55.47% of the subjects. According to the drop values size specifications and distribution of control dimensions are predicted About 69.82% of the expected frequency distribution were covered by 19 size specifications.

  • PDF

A study on the upper body type and size of men aged 30-44 for men jacket pattern design (남성 재킷 패턴 설계를 위한 30-44세 남성의 상반신 체형 및 유형별 사이즈 연구)

  • Kwon, Dong Kuk
    • The Research Journal of the Costume Culture
    • /
    • v.29 no.6
    • /
    • pp.881-903
    • /
    • 2021
  • This study aimed to analyze adult men's body sizes and shapes and suggest size specifications to provide preliminary data to academia and industries. A total of 814 adult men aged 30-44 were selected from the 7th Size Korea data, and 55 direct upper body measurement and calculation items were analyzed using SPSS 25.0. In individual Individual differences, thickness, circumference, and width were high, and height and length were low. Height above the waist base line and shoulder dimension decreased in early 40s age group, while height below the waist base line declined as age increased. In addition, buttocks shape changes were found in early 40s age group. According to factor analysis, 'upper body and upper-extremity horizontal size', 'torso height and upper extremity length', 'shoulder dimension', 'upper body length' and 'shoulder angle' were derived. Using clustering analysis, four different body types were classified: i) big abdomen with flat chest, ii) slender with big, raised shoulders, iii) dwarfish with small, droopy shoulders, and iv) obese with large shoulders. 'Slender with big, raised shoulders' was a typical body shape among men aged 30-44. In older participants, the 'big abdomen with flat chest' ratio was low, while 'obese with large shoulders' was more common. This study proposed size specifications by body type considering the above characteristics.

An Ensemble Classifier using Two Dimensional LDA

  • Park, Cheong-Hee
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.6
    • /
    • pp.817-824
    • /
    • 2010
  • Linear Discriminant Analysis (LDA) has been successfully applied for dimension reduction in face recognition. However, LDA requires the transformation of a face image to a one-dimensional vector and this process can cause the correlation information among neighboring pixels to be disregarded. On the other hand, 2D-LDA uses 2D images directly without a transformation process and it has been shown to be superior to the traditional LDA. Nevertheless, there are some problems in 2D-LDA. First, it is difficult to determine the optimal number of feature vectors in a reduced dimensional space. Second, the size of rectangular windows used in 2D-LDA makes strong impacts on classification accuracies but there is no reliable way to determine an optimal window size. In this paper, we propose a new algorithm to overcome those problems in 2D-LDA. We adopt an ensemble approach which combines several classifiers obtained by utilizing various window sizes. And a practical method to determine the number of feature vectors is also presented. Experimental results demonstrate that the proposed method can overcome the difficulties with choosing an optimal window size and the number of feature vectors.

Investigation of the effects of particle size and model scale on the UCS and shear strength of concrete using PFC2D

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Lazemi, Hossein Ali
    • Structural Engineering and Mechanics
    • /
    • v.67 no.5
    • /
    • pp.505-516
    • /
    • 2018
  • In this paper, the effects of particle size and model scale of concrete has been investigated on the failure mechanism of PFC2D numerical models under uniaxial compressive test. For this purpose, rectangular models with same particle sizes and different model dimensions, i.e., $3mm{\times}6mm$, $6mm{\times}12mm$, $12mm{\times}24mm$, $25mm{\times}50mm$ and $54mm{\times}108mm$, were prepared. Also rectangular models with dimension of $54mm{\times}108mm$ and different particle sizes, i.e., 0.27 mm, 0.47 mm, 0.67 mm, 0.87 mm, 1.07 mm, 1.87 mm and 2.27 mm were simulated using PFC2D and tested under uniaxial compressive test. Concurrent with uniaxial test, direct shear test was performed on the numerical models. Dimension of the models were $75{\times}100mm$. Two narrow bands of particles with dimension of $37.5mm{\times}20mm$ were removed from upper and lower of the model to supply the shear test condition. The particle sizes in the models were 0.47 mm, 0.57 mm, 0.67 mm and 0.77 mm. The result shows that failure pattern was affected by model scale and particle size. The uniaxial compressive strength and shear strength were increased by increasing the model scale and particle size.

A Study on Characteristics of Sedimentation Rate of Suspended Fine Particles under Floc Size and Density (플록의 입경과 밀도에 따른 부유된 미세 미립자의 침전률 특성에 관한 연구)

  • Kim, Jong-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.4
    • /
    • pp.107-113
    • /
    • 2009
  • This paper considers the influence of floc on the sedimentation rate for the cohesive material. The effects of floc density and size changes were also taking into consideration during the experiment. The settling velocity of a discrete floc was measured in a quiescent water column. Floc diameter and density were investigated using a modified Stokes equation with some constants such as water density, viscosity, material density and the floc fractal dimension $n_f$ obtained from the relationship between the floc diameter and the floc settling. The floc diameter of quartz and alumina increased at increasing initial concentrations. The floc size of quartz with increasing NaCl concentration varied between approximately 0.8 um to $10{\mu}m$. Floc density decreased as floc size increased. The floc settling velocity and the floc diameter have a straight line relationship on a logarithm. The floc fractal dimension nf was 2.65 with increasing of initial concentration and 2.93 with increasing of NaCl. The exponent n to predict the settling velocity was proposed and varied from 1 to 1.93.