• Title/Summary/Keyword: Sitting position

Search Result 364, Processing Time 0.027 seconds

Development of Patient Transfer Techniques based on Postural-stability Principles for the Care Helpers in Nursing Homes and Evaluation of Effectiveness (자세안정성 원리에 기반한 환자이동기술 개발 및 효과검정)

  • Ma, Ryewon;Jung, Dukyoo
    • Journal of Korean Academy of Nursing
    • /
    • v.46 no.1
    • /
    • pp.39-49
    • /
    • 2016
  • Purpose: This study was done to develop a postural-stability patient transfer technique for care helpers in nursing homes and to evaluate its effectiveness. Methods: Four types of patient transfer techniques (Lifting towards the head board of the bed, turning to the lateral position, sitting upright on the bed, transferring from wheel chair to bed) were practiced in accordance with the following three methods; Care helpers habitually used transfer methods (Method 1), patient transfer methods according to care helper standard textbooks (Method 2), and a method developed by the author ensuring postural-stability (Method 3). The care helpers' muscle activity and four joint angles were measured. The collected data were analyzed using the program SPSS Statistic 21.0. To differentiate the muscle activity and joint angle, the Friedman test was executed and the post-hoc analysis was conducted using the Wilcoxon Signed Rank test. Results: Muscle activity was significantly lower during Method 3 compared to Methods 1 and 2. In addition, the joint angle was significantly lower for the knee and shoulder joint angle while performing Method 3 compared to Methods 1 and 2. Discussion: Findings indicate that using postural-stability patient transfer techniques can contribute to the prevention of musculoskeletal disease which care helpers suffer from due to physically demanding patient care in nursing homes.

The Effects of Paced Breathing in Specific Respiration Rate on Heart Rate Variability (특정 호흡수에서 행한 통제호흡이 심박변이도에 미치는 영향)

  • Kim, Ji-Hwan;Kim, Byoung-Soo;Park, Seong-Sik;Lee, Yong-Jae;Keum, Na-Rae;Bae, Hyo-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.28 no.2
    • /
    • pp.123-131
    • /
    • 2016
  • Objectives We observed what effects of Paced Breathing(PB) in specific respiration rate have on heart rate variability (HRV) according to Sasang Constitution.Methods HRV of 72 healthy participants in sitting position was recorded while they carried out usual breathing, 0.2Hz, 0.1Hz, and 0.05Hz PB each 5 minutes in consecutive order. Five minute of relaxation was permitted between each breathing. Finally, HRV indices were statictically analyzed of 32 participants (SOEUM: 11, SOYANG: 10, TAEEUM: 11) after data out of accord with respiration rate or outliers were excluded.Results and Conclusions According to respiration rates, there was no statistical significance of HRV among Sasang Constitution. Regardless of Sasang Constituion, 0.2Hz PB increased mean heart rate and decreased natural logarithmic low frequency(lnLF) oscillation of HRV without the change of natural logarithmic high frequency(lnHF), while 0.1Hz PB increased lnLF and standard deviation of N-N interval(SDNN), and slightly decreased lnHF without the change of mean heart rate. 0.05 Hz PB also showed the same effect as 0.1Hz PB, but was impracticable.

The Effect of Navicular Drop on The Clinical Measures of Lower Extremity Alignment (주상골 하강이 하지 배열의 임상적 평가에 미치는 영향)

  • Kim, Jun-Woo;Lee, Eun-Hee;Ko, Kyoung-Hee;Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Purpose : This study aimed to examine the relationships among five clinical measures for functional alignment of the lower extremity. Methods : Thirty healthy subjects (15 males and 15 females) were recruited for the study. The five clinical measures of functional alignment of the lower extremity included navicular drop, quadriceps angle, internal rotation of hip, and anterior and lateral pelvic tilt angles. The level of navicular drop was calculated by the difference between the height of the navicular bone in the sitting (non-weight bearing) and standing (weight bearing) positions. The quadriceps angle and internal rotation of hip were measured using a standard goniometer with photographic markers while the subjects were lying in a prone position on a table with their knee at $90^{\circ}$ flexion. Anterior and lateral pelvic tilt angles were determined using a inclinometer. Results : Correlation and a simple linear regression analysis were used to assess relationships between the clinical measures. There were significant correlations between navicular drop and quadriceps angle (p<.05), between navicular drop and internal rotation of hip (p<.05), and between quadriceps angle and internal rotation of hip (p<.01). In simple linear regression analysis, the navicular drop appeared to be a factor affecting the quadriceps angle and internal rotation of hip (p<.05). The findings suggest that navicular drop has a great impact on lower extremity alignment. Conclusion : This study might help us to examine lower extremity function and clarify its role as a potential injury risk factor.

  • PDF

Comparison of Upper and Lower Trapezius Activity During Shoulder Elevation and Depression for Acute and Chronic Whiplash-associated Disorder Patients (급성과 만성 편타성-관련 손상 환자의 상지 거상과 하강 동작시 상승모근과 하승모근의 근활성도 비교)

  • Kim, Sang-Su;Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.26-36
    • /
    • 2010
  • Purpose: The study compared the muscle activity and ratio of upper trapezius (UT) to lower trapezius (LT) activity between acute and chronic whiplash-associated disorder (WAD) patients. Methods: Twelve healthy (male: 7), 14 acute WAD (male: 7), and 11 chronic WAD (male: 3) volunteers participated in this study. Electromyography using a surface EMG recorded the activity of the upper trapezius and lower trapezius of both shoulders (dominant and non-dominant) during $120^{\circ}$ elevation when standing and shoulder depression when sitting. The testing order was selected randomly. Subjects were asked to maintain each experimental position for 5 seconds at end range. EMG activity was normalized using the maximal voluntary isometric contraction (MVIC) elicited using a manual muscle-testing technique. One-way repeated measures analysis of variance (ANOVA) was used to compare the average root mean square (RMS) value of EMG activity for each condition. Results: The EMG activity of the dominant UT for chronic WAD subjects was significantly higher than for acute WAD subjects during $120^{\circ}$ elevation (p<.05). The EMG activity of the dominant LT for acute WAD subjects was significantly lower than for the control group (p<.05) during $120^{\circ}$ elevation. The EMG activity of the dominant LT for WAD patients was significantly lower than for the control group during shoulder depression (p<.05), and the chronic WAD patients scored significantly the lowest (p<.01). The dominant UT/LT for chronic WAD patients was significantly higher than the ratio for acute WAD subjects during shoulder depression (p<.05); this result was higher than for the control group (p<.01). The non-dominant UT/LT (ratio) for chronic WAD patients was significantly higher than the ratio for acute WAD subjects during shoulder depression (p<.05). Conclusion: The UT for chronic WAD subjects was hyperactive when compared to the acute WAD subjects, and the was hypoactive for both acute and chronic patients, therefore intra-trapezius imbalance was more prevalent during shoulder depression.

  • PDF

The immediate effects of local vibration on ankle plantar flexor muscle activation and peak torque in healthy adults

  • Cho, Minjo;Yoon, Doyoo;Yoo, Jaehyun;Yi, Donghyun;Kang, Daewon;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.2
    • /
    • pp.113-119
    • /
    • 2020
  • Objective: The vibration device is one of the most commonly used warm-up devices not only for healthy athletes but also for healthy individuals. Therefore, this study aimed to investigate the immediate effects of local vibration on ankle plantar flexor muscle activation and peak torque in healthy adults. Design: One-group pretest-posttest design. Methods: This was a single-group study comprising a total of 36 (16 males and 20 females) participants. The average age of the 36 participants was 22.3 years. All the participants' concentric and eccentric peak torques of the gastrocnemius lateralis muscle were measured using an isokinetic device. Simultaneously, the participants' muscle activity was measured by surface electromyography. After the pre-experimental data were collected, the participants comfortably sat on the prepared chair with their hips and knees flexed to 90°. While in sitting position, local vibration was applied for 10 minutes using a 1:1 ratio intermittent pulsing mode device based on a previous study. Then, the post-experimental data were collected immediately after the local vibration by performing a similar process performed during the pre-experimental data collection. Results: The results showed a significant difference in muscle activity and eccentric peak torque (p<0.05). On the contrary, concentric peak torque values showed an insignificant difference with pre- and post-value. Conclusions: The results of this study demonstrated that local vibration can be possibly considered as one of the effective ways to increase ankle plantar flexor muscle activity and muscle performance, specifically the eccentric peak torque, in healthy adults.

Reliability and validity of pelvic mobility measurement using a cushion sensor in healthy adults

  • Jung, Seung-Hwa;Kim, Su-Kyeong;Lee, Ji-Hyun;Choi, Soo-Ih;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.2
    • /
    • pp.74-81
    • /
    • 2020
  • Objective: To prevent low back pain, an objective evaluation tool to evaluate pelvic mobility and exercise to improve the flexibility of the lumbar region is needed. The purpose of this study was to compare the results of pelvic mobility measurements using the Wii Balance Board (WBB) and Sensbalance Therapy Cushion (STC), evaluate the usefulness of the STC as a tool for measuring pelvic mobility. Design: Cross-sectional study. Methods: Fifty healthy subjects participated in this study. The subjects performed pelvic mobility range, proprioception, reaction time and reach of the arm using the STC. The pelvic movement parameter was measured two times to determine the intra-rater reliability. To measure the correlation between lumbar muscle tension and pelvic mobility, Myovision was used to measure tension of L4, L5 level erector spinae muscle. Correlations between measured variables were checked to determine the validity of the pelvic mobility assessment tool. Results: STC showed high test-retest reliability in pelvic tilt measurement and reaching task [intraclass correlation coefficients (3,1)=0.804-0.915]. The relationship between WBB and STC showed a significant positive correlation with the pelvic tilt and reaching task (p<0.05). Posterior tilt and erector spinae activation (Lt. L5) showed a significant negative correlation (p<0.05). Left, right tilt and erector spinae activation (L5) showed a significant negative correlation (p<0.05). Conclusions: This study confirmed the advantages of the STC and found efficiency as an objective measuring device of pelvic mobility.

Wearing Acceptability of Chemical Protective Clothing during Fire Training (소방훈련시 화학보호복 착용에 따른 동작만족도 연구)

  • Bang, Changhoon;Kwan, Jungsuk
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.110-115
    • /
    • 2020
  • The aim of this study was to investigate the wearing acceptability of chemical protective clothing during fires and to provide basic data for the safety of firefighters. The results of the study were as follows: Wearer acceptabilities of chemical protective clothing under static movement (e.g., looking at the ceiling with maximum head bending, wrapping one's arms around oneself, sitting obliquely on the floor, and maintaining a crouching position) were 21.7%-47.8% lower than those of general uniforms. When wearing chemical protective suits, the acceptability under static movement was statistically low (p < .001). Wearer acceptabilities of chemical protective clothing under dynamic movement (e.g., running, lifting a heavy object (20 kg) up to the waist, lifting and moving a heavy object (20 kg) by 1 m, lifting a stretcher and walking forward, and lifting a stretcher and walking backward) were 19.2%-47.8% lower than those of general uniforms. When wearing chemical protective suits, the acceptability under dynamic movement was also statistically low (p < .001).

A Study on the Clothing Easiness of Movement for Casual Hanbok as School Summer Uniform (생활한복형 하절교복의 동작기능성)

  • Yoo, Jung-Ja;Kweon, Soo-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.2
    • /
    • pp.212-222
    • /
    • 2008
  • This study investigated the clothing easiness of movement when wearing casual Hanbok(Saenghwal Hanbok), as a high school student uniform, and produced some recommendations for improving the Hanbok. Casual summer-uniform Hanbok produced from different types of materials were produced for this study. They were P/R, P100, P/C, and P/R/S for the blouses, with P/W, P100, P/R, and P/W/F for the skirts. Their clothing easiness of movement were then tested at $25{\pm}1^{\circ}C$ and $50{\pm}10%$ R. H. The results were as follows: The easiness of movement for casual Hanbok was marked as $3.7l({\pm}1.03)$ on average which is higher than those of other garments, so it can be presumed that the easiness of movement for the tested clothes was quite good. The easiness of movement was lower, however, when students had their arms up front, right arms upright, arms crossed on the cheats, and bent forward whereas they were more comfortable when standing straight and sitting on a chair at 90 degrees. In terms of easiness of movement, the following ranking was revealed: waist, bust, shoulder, back, armhole, and upper arm. The easiness of movement for casual Hanbok skirts was quite good, and on average marked around $4.26({\pm}.77)$. Standing straight was the most comfortable position, when they bend forward 45 degree and 90 degree were the most uncomfortable positions. The buttocks area was also more comfortable than the waist area for casual Hanbok skirts.

Reliability study of the Pectoralis Minor Muscle Thickness Measurement using Rehabilitative Ultrasound Imaging

  • Lim, Ji Young;Lee, Se-Yeong;Jung, Seung-Hwa;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2021
  • PURPOSE: This study examined the imaging procedure of pectoralis minor muscle thickness and assessed the intra- and inter-rater reliability of the muscle thickness measured by two raters using rehabilitative ultrasound imaging (RUSI) in healthy individuals. METHODS: Fifteen participants (aged 21 - 28, seven females, and eight males) were involved in the study. The primary rater palpated the coracoid process and the fourth rib, defined as the width of the index finger lateral to the sternum to avoid breast tissues, and lined the two landmarks. The second examiner checked 1 / 3 (1st point) and 1 / 2 (2nd point) of the line length as measurement points. The two raters obtained right side muscle images of the participants at a standardized sitting position using RUSI with a 7.5 MHz linear transducer at 40mm depth. For intra-rater reliability, the principal rater took three images per point and tried to take one more with an interval. For the inter-rater reliability, the other rater performed the same tasks as the principal rater on the same day. The reliability was analyzed using the intra-class correlation coefficient (ICC), the standard error of the measurement (SEM), and Bland and Altman plots. RESULTS: The reliability at all points was excellent for the same rater (ICC3,1 = .973 - .978, SEM = .042 - .046), and between raters (ICC2,1 = .939 - .959, SEM = .059 - .097). CONCLUSION: These findings show that the RUSI could be reliable for examining the pectoralis minor muscle thickness in healthy individuals at all measurement sites.

Improvement of Peak Cough Flow After the Application of a Mechanical In-exsufflator in Patients With Neuromuscular Disease and Pneumonia: A Pilot Study

  • Jung, Ji Ho;Oh, Hyeon Jun;Lee, Jang Woo;Suh, Mi Ri;Park, Jihyun;Choi, Won Ah;Kang, Seong-Woong
    • Annals of Rehabilitation Medicine
    • /
    • v.42 no.6
    • /
    • pp.833-837
    • /
    • 2018
  • Objective To investigate and demonstrate persistent increase of peak cough flow after mechanical in-exsufflator application, in patients with neuromuscular diseases and pneumonia. Methods A mechanical in-exsufflator was applied with patients in an upright or semi-upright sitting position (pressure setting, +40 and $-40cmH_2O$; in-exsufflation times, 2-3 and 1-2 seconds, respectively). Patients underwent five cycles, with 20-30 second intervals to prevent hyperventilation. Peak cough flow without and with assistive maneuvers, was evaluated before, and 15 and 45 minutes after mechanical in-exsufflator application. Results Peak cough flow was 92.6 L/min at baseline, and 100.4 and 100.7 L/min at 15 and 45 minutes after mechanical in-exsufflator application, respectively. Assisted peak cough flow at baseline, 15 minutes, and 45 minutes after mechanical in-exsufflator application was 170.7, 179.3, and 184.1 L/min, respectively. While peak cough flow and assisted peak cough flow increased significantly at 15 minutes after mechanical in-exsufflator application compared with baseline (p=0.030 and p=0.016), no statistical difference was observed between 15 and 45 minutes. Conclusion Increased peak cough flow after mechanical in-exsufflator application persists for at least 45 minutes.