• 제목/요약/키워드: Site investigation

검색결과 1,550건 처리시간 0.032초

국내 오염부지 조사 개선을 위한 US EPA 스마트 스코핑 기술 소개 (Introduction to US EPA Smart Scoping Technical Guide for Improving Pollution Site Investigation)

  • 김보민;김한석;권만재;조호영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권2_spc호
    • /
    • pp.70-85
    • /
    • 2020
  • This paper introduces the 'Smart Scoping for Environmental Investigations Technical Guide' issued by the US Environmental Protection Agency in 2018, which describes the use of smart scoping during lifecycle of remedial investigation projects. This paper also briefly summarizes the guidelines of soil and groundwater contamination investigation of South Korea. The smart scoping practices can support the development of a robust and realistic conceptual site model that is very useful for investigations and evaluations of the contaminated site. The application of evaluation tools relevant for the site-specific characteristics is important for the development of a conceptual site model. The smart scoping recommends the use of previous investigation data and implementation of best proven strategies for successful remedial investigation project. The use of smart scoping in contaminated site investigation will provide better management of contaminated sites.

건강보험 현지조사제도에서 일반적 억제이론에 대한 경험적 연구 (An Empirical Study on General Deterrence Effects of the On-site Investigation System in the Korean National Health Insurance)

  • 강희정;홍재석;김세라;최지숙
    • 보건행정학회지
    • /
    • 제19권3호
    • /
    • pp.109-124
    • /
    • 2009
  • Background: This study aimed to examine whether cases of punishing false claimants threat general physicians to check their medical cost claims with care to avoid being suspected, and identify empirically general deterrence effects of the on-site investigation system in the Korean National Health Insurance. Methods: 800 clinics were selected among a total of 15,443 clinics that had no experience of on-site investigation until June 2007 using a stratified proportional systematic sampling method. We conducted logistic multiple regression to examine the association between factors related to provider's perception of on-site investigation and high level of perceived deterrence referring to fear of punishment after adjusting provider's service experiences and general characteristics. Results: The probability of high perceived deterrence was higher 1.7 times (CI: 1.13-2.56), 2.73 times (CI: 1.68-4.45) each among clinics exchanging the information once or more per year or once or more for 2-3 months than among clinics no exchanging the information about on-site investigation. Also, the probability of high perceived deterrence was higher 2.27 times (CI: 1.28-4.45) among clinics that knows more than 3 health care institutions having experienced an on-site investigation than among clinics knowing no case. Conclusion: A clinic knowing more punishment cases by onsite investigation and exchanging more frequently information about on-site investigation is likely to present high perceived deterrence. This result will provide important information to enlarge preventive effects of on-site investigation on fraud and abuse claims.

산업공장 주변 토양오염도 조사 분석 (Investigation and Analysis of Soil Contamination at Industrial Site)

  • 정하익;김상근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.99-102
    • /
    • 2000
  • There has been a steady increase in contaminated ground at municipal and industrial site. In this study, investigation and analysis on soil contamination at industrial site was carried out. Testing contaminated soils were sampled at this site. As a result of this study, the concentration of soil was investigated, and measured concentration was compared with related concentration criteria.

  • PDF

해체부지의 잔류방사능 조사 절차 수립에 관한 연구 (Study on the Establishment of Residual Radioactivity Investigation Procedure in Decommissioning Site)

  • 김학수;임용규;박경록;손중권;강기두;김경덕;정찬우
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.24-31
    • /
    • 2004
  • 원자력발전소를 안전하게 해체하기 위해서는, 해체부지 개방기준의 준수여부를 확인하기 위해 수행되는 환경이나 설비의 방사선학적 조사의 계획, 실시 그리고 평가에 대한 상세 지침을 제공하는 절차가 필요하다. 본 연구에서는 해외 원전 해체 사례와 MARSSIM을 근간으로 부지운영이력평가, 오염범위조사, 오염현황 상세 조사, 제염복구 지원조사, 최종부지조사의 순으로 해체 부지내 잔류방사능을 조사하는 절차를 제시하였다.

  • PDF

초등학교(初等學敎) 입지(立地)에 따른 건축적(建築的) 환경(環境) 조사연구(調査硏究) - 부산시내 택지개발지구를 중심으로 - (A Study to investigate architectural environment caused by the location of an Elementary school - On the basis of district of building site development in Busan city -)

  • 손윤득;류종우
    • 교육시설
    • /
    • 제12권1호
    • /
    • pp.41-53
    • /
    • 2005
  • The purpose of this study is to suggest the reference materials in the selection of location of elementary school at the planning of building site development by analyzing the environment of architecture in the district of building site development. The method of investigation adapted the site investigation and drawing analysis of the elementary school, after collecting materials of the district of building site development within Busan city, under the object of investigation including 17 elementary schools within 15 districts of building site development and the object of investigation.

가습기살균제 사용 의료기관 노출 현황 연구: 23개 노출 현장 실지 조사를 중심으로 (Investigation of Exposure Status to Humidifier Disinfectant in Hospitals: An On-site Investigation of 23 Hospitals)

  • 한경희;조은경;서영준;곽정현;양원호;김판기;최윤형
    • 한국환경보건학회지
    • /
    • 제46권4호
    • /
    • pp.433-443
    • /
    • 2020
  • Objective: This study aimed to introduce the use of humidifier disinfectant (HD) in hospitals based on an on-site investigation. Methods: A preliminary survey and on-site investigation of HD use were conducted in 23 hospitals. Among them, one hospital without previous information on HD use was selected for a pilot investigation; 22 hospitals were selected based on previous documents and exposure statements from parliamentary investigation and exposure assessment regarding HD. Descriptive statistics were used to present distribution and characteristics of HD purchase and HD use in hospitals. Also, details on interviews from the on-site investigation were described. Results: Among the 23 hospitals, a total of ten were confirmed to have purchased and used an HD (nine hospitals) or HD-like product (one hospital). For the purchased HD products, four hospitals reported 'Aekyung Gaseupgi Mate', two hospitals reported 'Oxy Ssakssak New Gaseupgi Dangbun', and one hospital reported 'Homeplus Gaseupgi Chungjungje' (one hospital used three kinds of HD products). One hospital reported an HD-like product and four hospitals were 'Unknown'. For the number of HD products purchased, five hospitals reported '100 or less', two hospitals reported 'More than 100', and three hospitals were 'Unknown'. For each of the ten hospitals, we described detailed characteristics of HD purchase and its exposure status obtained through on-site investigation, including the purchase volume (i.e., number of products), exposure space (i.e., patient's room, staff space), and exposure period. Additionally, a comparison of on-site investigation and parliamentary investigation or exposure assessment regarding HD was reported. Conclusion: This study introduced detailed cases of HD purchase and HD use in hospitals based on an on-site investigation, and our findings revealed a possibility of a considerable volume of HD exposure in various multiuse facilities, including hospitals.

조력발전 구조물 설계를 위한 지반조사;인천만 지반조사 사례 (Geotechnical Site Investigation for Designing of Tidal Power Plant Structures)

  • 오명학;이광수;박진순;염기대;차대욱;양근훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.613-616
    • /
    • 2007
  • The main structures that comprise a tidal power plant are turbine structure, sluice structure, tide embankment and gate. Since these structures are founded on seabed ground, an extensive geotechnical site investigation to evaluate the engineering properties of field soils must be conducted prior to design and construction. According to the results of geotechnical site investigation conducted at the planned site for construction of Incheon bay tidal power plant, soft ground generally lie 7 meters below the seabed surface level. This research suggests the reliable and economical design of foundations and ground improvements required for construction of main structures in Incheon bay tidal power plant, with considerations on field conditions.

  • PDF

유류오염부지 정밀조사에 기반한 부지개념모델 구축 및 개선 (Construction and Refinement of Conceptual Site Model Based on Scrutiny of Oil Contaminated Site)

  • 배민서;김민경;김주희;이순재;권만재;조호영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제28권2호
    • /
    • pp.12-29
    • /
    • 2023
  • Conceptual site model (CSM) development and enhancement for contaminated sites assists in identifying data gaps during the site investigation process. In this study, CSM was developed and enhanced for a contaminated site in Korea as a case study. Site Y was scrutinized four times previously. The site profiles for each scrutiny were reorganized based on the scrutiny reports, and the relevant data was utilized to develop and enhance CSMs. CSM for the first investigation was developed in various forms including table, flowchart, diagram, and narrative formats. CSM was enhanced in a stepwise manner by incorporating the updated profile information obtained in next investigation to existing CSM. The hypothetical data gap analysis between each investigation step was established to meet the purpose of the follow-up investigation. This case study showed that CSM is a useful tool to identify the history and current status of contaminated sites and thereby help in planning supplementary investigations for better site characterization.

표면파 분산특성과 전기비저항 분포특성에 대한 인접구조물의 영향 (Influence of Adjacent Structures on Surface-Wave Dispersion Characteristics and 2-D Resistivity Structure)

  • 조성호;김봉찬;조미라;김석철;윤대희;홍재호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1318-1327
    • /
    • 2008
  • Geotechnical sites in urban areas may have embedded structures such as utility lines and underground concrete structures, which cause difficulties in site investigation. This study is a preliminary research to establish knowledge base for developing an optimal technique for site investigation in urban areas. Surface-wave method and resistivity survey, which are frequently adopted for non-destructive site-investigation for geotechnical sites, were investigated to characterize effects of adjacent structures. In case of surface wave method, patterns of wave propagation were investigated for typical sets of multi-layered geotechnical profiles by numerical simulation based on forward modeling theory and field experiments for small-size model tests and real-scale tests in the field. In case of resistivity survey, 3-D finite element analyses and field tests were performed to investigate effects of adjacent concrete structures. These theoretical and experimental researches for surface-wave method and resistivity survey resulted in establishing physical criteria to cause interference of adjacent structures in site investigation at urban areas.

  • PDF

해상 지반조사 분야의 기술 동향 (Technical Trend of Offshore Geotechnical Site Investigations)

  • 조성민
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.639-653
    • /
    • 2007
  • Offshore geotechnical site investigation of the seabed ground has been a key factor of the successful construction of various types of offshore structures like as sea-crossing bridges, submerged tunnels, and other marine facilities. Offshore investigations are not easy tasks because of the wave, wind, tidal ebb and flows, and others. Recent developments of offshore equipment including platforms and testing devices like as maine cone penetrator have inspired us to get more reliable characteristics of the seafloor. General information on the offshore site investigations and technical trends concerned are introduced.

  • PDF