• Title/Summary/Keyword: Site assessment test

Search Result 219, Processing Time 0.018 seconds

The Study on the Improvement of Environmental Assessment Method through Analysis of Environmental Investigation Results of Taean Thermal Power Plant (환경영향평가와 사후환경조사의 비교에 관한 연구 - 태안화력발전소 사례분석 -)

  • Chun, Sang-Ki;Lee, Sung-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.1
    • /
    • pp.61-74
    • /
    • 2000
  • This study compares the results of environmental impact assessment with the results of post-environmental investigation, using the case of Taean thermal power plant construction. The atmospheric and water qualities were not greatly changed before and after the construction of the power plant. However, the site of the highest concentration predicted by the atmospheric quality modeling in environmental impact assessment was different from that after operation of 4 power plants. There was also a difference in the diffusion range of thermal discharge water between the measured result(1km) and the predicted value(1.5km) with the model. Thus, environmental impact evaluation should be based on long-term (more than a year) environmental monitoring data. For the modeling of atmospheric quality and numerical thermal discharge water diffusion, appropriate models for each plant should be selected and the numerical modeling should be accompanied by computer simulation, wind tunnel test, etc. Moreover, environmental evaluation should focus more on the degree of impact on surroundings than the prediction of changes in surroundings caused by operation of plants.

  • PDF

Assessment of a concrete arch bridge using static and dynamic load tests

  • Caglayan, B. Ozden;Ozakgul, Kadir;Tezer, Ovunc
    • Structural Engineering and Mechanics
    • /
    • v.41 no.1
    • /
    • pp.83-94
    • /
    • 2012
  • Assessment of a monumental concrete arch bridge with a total length of 210 meters having three major spans of 30 meters and a height of 65 meters, which is located in an earthquake-prone region in southern part of the country is presented in this study. Three-dimensional finite element model of the bridge was generated using a commercially available general finite element analysis software and based on the outcomes of a series of in-depth acceleration measurements that were conducted on-site, the model was refined. By using the structural parameters obtained from the dynamic and the static tests, calibrated model of the bridge structure was obtained and this model was used for necessary calculations regarding structural assessment and evaluation.

Probabilistic Risk Assessment Techniques for the Risk Analysis of Construction Projects (건설공사의 위험도분석을 위한 확률적 위험도 평가)

  • 조효남;임종권;박영빈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.04a
    • /
    • pp.27-34
    • /
    • 1997
  • In this paper, systematic and comprehensive approaches are suggested for the application of quantitative PRA techniques especially for those risk events that cannot be easily evaluated quantitatively In addition, dominant risk events are identified based on their occurrence frequency assessed by both actual survey of construction site conditions and the statistical data related with the probable accidents. Practical FTA(Fault Tree Analysis) and ETA(Event Tree Analysis) models are used for the assessment of the identified risks. When the risk events are lack of statistical data, appropriate Bayesian models incorporating engineering judgement and test results are also introduced in this paper. Moreover, a fuzzy probability technique is used for the quantitative risk assessment of those risk components which are difficult to evaluate quantitatively.

  • PDF

A Study on On-Site Railroad Track Structure Performance Improvement Methods for Low-Maintenance (현장궤도 생력화를 위한 도상구조 개선에 관한 연구)

  • 양재성;이희현;남보현
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.479-486
    • /
    • 2000
  • There has been recently an on-going effort in railway community to improve the dynamic performance of on-site railroad track with limited track possession time. In this paper, train running test lateral resistant force test and static/dynamic analyses are conducted before and after sprinkle of the ballast stabilizer in order to investigate the dynamic behaviors and parameters of the railroad track. Based upon the above results, effects of the stabilizer is verified, and a table for the track modulus representing on-site track condition and the methods to reduce the vibration and the transmitting forces of the ballasted track components to the infrastructures are suggested. It is thought that the suggestions made in this paper could be used as the preliminary data for the condition assessment and the maintenance of the track in the future.

  • PDF

Accelerated Life Test Design of an Electromagnetic Shielding Door Hinge (전자파 차폐도어용 힌지의 가속 수명 시험법 설계)

  • Kim, Do Sik;Cheong, Han Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.887-895
    • /
    • 2017
  • This paper presents a study on the accelerated life tests of parts that operate during the opening and closing of door frames, particularly door hinges. Hinge theoretical verification and validation of the test equipment in the present study and the different structures and fault mode, depending on the purpose of usage analysis, failure mode for one of the hinges of the switchgear components used for electromagnetic shielding facilities and on-site operating conditions. The accelerated life test was designed for the characteristic lifetime prediction of the components, by estimating the shape parameter and the acceleration factor.

Toxicity test of wetland sediments by Simocephalus mixtus (국내종 물벼룩 Simocephalus mixtus에 의한 습지퇴적물 독성도 측정)

  • 이찬원;권영택;윤종섭;문성원
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.851-855
    • /
    • 2002
  • A comparison of Daphnia magna, Ceriodaphnia dubia and Simocephalus mixtus toxicity test was performed to study the relative sensitivities and discrimination abilities with both pore and elutriate water of Woopo wetland sediments. Sediment risk assessment has been done by standardized preparation method of pore and elutriate water described in the joint US EPA-US Army Crops of Engineers manual. Simocephalus mixtus which was obtained from Woopo wetlands in Korea was cultured and applied to sediment toxicity test. Water quality in Woopo wetland had great site and seasonal variations. S. mixtus was more sensitive than D. magna in heavy metal toxicity test. The toxicity results with S. mixtus reflected the water quality of elutriate and pore water. The results also suggested that S. mixtus could be used as a test organism in estimating potential risk of contaminated sediments.

Stability Assessment of an Adjacent Ground Storage Tank by Blast-induced Vibration (발파진동에 대한 인접한 지상 저장탱크의 안정성 평가)

  • Jong, Yong-Hun;Lee, Chung-In;Choi, Yong-Kun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.1 s.106
    • /
    • pp.19-26
    • /
    • 2006
  • The test blasts were carried out by detonating some single blastholes at two upper sites of the underground storage cavern for the crude oil. One was performed at the entrance site of the construction tunnel and the other at the middle area of the underground storage cavern. Based on the blast-induced nitration measured by the test blasts, we suggested the propagation equations of blasting vibration that were capable of estimating the peak particle velocity. In addition, in order to assess the stability of the adjacent ground storage tank, we did the frequency analysis and the response spectrum analysis with the particle velocity-time history and the particle acceleration-time history that were measured by the test blast carried out on the entrance site of the construction tunnel. In result, it was predicted that the displacement on the highest part of the tank shell was less than the allowable displacement.

A Case Study on the Stability Assessment of Structures by Blast-induced Vibration (발파진동에 대한 구조물 안정성 평가 - 지하비축기지 건설 사례)

  • Lee, Chung-In;Choi, Yong-Kun;Jong, Yong-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.479-484
    • /
    • 2005
  • The test blasts were carried out by detonating some single blastholes at two upper sites of the underground storage cavern the crude oil. One was performed at the entrance site of the construction tunnel and the other at the middle part of the underground storage cavern. Based on the blast-induced vibration measured by the test blasts, we suggested the propagation equations of blasting vibration that were capable of estimating the peak particle velocity. In addition, in order to assess the stability of the nearest ground storage tank, we did the frequency analysis and the response spectrum analysis with the particle velocity-time history and the particle acceleration-time history that were measured by the test blast carried out on the entrance site of the construction tunnel. In result, it was predicted that the displacement on the highest part of the tank shell was less than the allowable displacement.

  • PDF

Non-Point Source Pollutions of the Youngsan River Basins I - The Method of Land-Use Types and Rainfall - (영산강 수계의 비점오염원에 관한 연구 I - 토지이용 및 강우를 중심으로 -)

  • Cha, Jin Myeong;Shin, Sung Euy;Cha, Gyu Suk
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.1
    • /
    • pp.41-49
    • /
    • 1999
  • This study was carried out to estimate the runoff loading characteristics of the non-point source pollutions in the Youngsan river basins by the method of land-use types and rainfall. The lysimeter test, rainfall and stream flowmeter measurement were performed to develop the pollutant loading unit discharged from the non-point sources. As the non-point sources, the unit pollutant discharge rates were different from the land-use types such as paddy field, upland, forest, housing site and others. The pollutant loading units classified by land-use types in the Youngsan river basins are as follows: The total BOD loading rate is 15.3 ton/day and the housing site is discharged 50.6%, the total T-N loading rate is 6.0 ton/day and the paddy field and upland is discharged 77.6%, and the total T-P loading rate is 0.39 ton/day and the paddy field and upland is discharged 81.2%. The pollutant loadings by rainfall in the Youngsan river basins are about 7,425 ton/year of BOD, 324 ton/year of T-N and 118 ton/year of T-P, respectively.

  • PDF

Characteristic Accelerated Aging Assessment for Coolant Rubber Hose of Automotive Radiator (자동차 냉각기 고무호스의 가속 노화거동 평가)

  • Kwak, Seung-Bum;Choi, Nak-Sam;Kang, Bong-Sung;Shin, Sei-Moon
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.27-31
    • /
    • 2006
  • Rubber hoses for automobile radiators are apt to degraded and thus failed due to the influence of contacting stresses of air and coolant liquid under thermal and mechanical loadings. The aging behaviors of the skin part of the hoses due to thermo-oxidative and electro-chemical stresses were experimentally analyzed. Through the thermo-oxidative aging test, it was shown that the surface hardness IRHD(International Rubber Hardness Degrees) of the rubber increased with a considerable reduction of failure strain as the aging time and temperature were large. On account of the penetration of coolant liquid into the skin part the weight of rubber specimens influenced by electro-chemical degradation (ECD) test increased, whereas their failure strain and IRHD hardness decreased. The hardness decreased further as the test site on the hose skin approached to the negative pole.

  • PDF