• Title/Summary/Keyword: Site Condition

Search Result 2,019, Processing Time 0.026 seconds

A Study on the Layout of the 2nd construction in Hwangnyongsa Buddhist Temple Site (황룡사 중건가람배치 연구)

  • Kim, Sookyung
    • Journal of architectural history
    • /
    • v.23 no.4
    • /
    • pp.81-90
    • /
    • 2014
  • This paper aimed to identify the variation of layout in Hwangnyoungsa buddhist temple site based on studying published the excavation research paper and texts related to layout. According to earlier studies, in 1st construction period(553~569) of Hwangnyoungsa, there were trisection spaces with one main hall and two corridors in inner part and then in 2nd period(584~645), unified one. But actually trisection spaces had been maintained until the middle part of 8th century. And in each space there was the main hall with large yard. That is the 2nd period layout of Hwangnyoungsa. For the attainment this result, each building remains are judged under duplicated situation which one was the previous and next by consideration of the construction condition and special features of foundation. Although the meaning of trisection system of Hwangnyoungsa is similar with the layout of ancient palace, it could be said to derive from accumulation excavation research in Silla's archeological site and such studies.

A Study on the Application in Site of the Concrete Using Fly Ash Produced in Combined Heat Power Plant (열병합발전소 플라이애쉬를 사용한 콘크리트의 현장적용에 관한 연구)

  • 김무한;이상수
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.41-49
    • /
    • 1999
  • This study dealt with the applicability and quality control of the concrete using fly ash produced in combined heat power in a construction site. Firstly, chemical and physical characteristics of the fly ash produced in combined heat power plant re analysed. Also, after investigating the properties of flesh and hardened concrete through various experiments, the fly ash concrete was placed in depositing construction in Ulsan Petrochemical Service Co. This field application was focussed on the quality control system in the site as production, placing and curing of concrete. As the result of this study, the quantity of CaO in the fly ash is relatively high based on the chemical analysis. The fly ash concrete showed slumping maintenance and high viscosity properties in the optimal mixing conditions (W/B:44~45%, S/a:$45\pm$2%, W:185kg/m). And, quality control and assurance of the fly ash concrete in actual site were verified by various testing methods.

Factor Analysis of the Aircraft Noise Impact Assessment in the Building Site Development District Around of Gimpo Airport (김포공항 주변 택지개발지구 항공기소음 영향평가에 미치는 요인분석)

  • Kim, Heung-Sik;Ju, Si-Woong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.718-723
    • /
    • 2005
  • The purpose of this study is to present a fundamental data for evaluating aircraft noise of building site development. By the field experiments and the predicted equal noise level contours using the INM program, actual condition in the building site development arranged district was investigated. In order to get the results, Analysis of factors effected on noise level, sound level on the rate of increase to aircraft demand and difference on the aircraft noise levels according to floor level in apartment house was carried out. As a result the influence of the take-off and landing direction were appeared greatly. The influences of the height at receiving point, movement number of aircraft and increase to aircraft demand were appeared small And the influence of 1 day average WECPNL must be considered.

The site application with 700kg/$\textrm{cm}^2$ high strength concrete (700kg/$\textrm{cm}^2$ 고강도 콘크리트의 현장적용)

  • 권영호;박정국;이보근;박칠림
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.124-131
    • /
    • 1993
  • A successful site application with 700kg/$\textrm{cm}^2$ ultra-high strength concrete was made by research team of Daewoo Institute of Construction Technology in Jinhae. Trial mixings of concrete, the productivity of batcher plant, the elapsed time and the pumpability had been investigated for the site condition, before the site application. As results, the efficiency of production by automatic batcher plant systems was improved and the method of quality control was estabilished for the security of fluidity due to the elapsed time, the pumping and consolidation and so on. The concrete strength cores as well as cylinders was showed more than 700kg/$\textrm{cm}^2$ for the required age. And this study would be provided valuable data base for the practical utilization of high strength concrete. Further, this study would be given new possibilities of high rise RC constructions.

  • PDF

Consciousness of Safety Engineer for Foreign Workers at a construction site (안전관리자의 건설현장 외국인 근로자에 대한 의식조사)

  • Son, Ki-Sang;Lee, Seung-Young
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.1
    • /
    • pp.41-47
    • /
    • 2008
  • Safety training for foreign workers should be thoroughly done. But it has not been done well even if field safety manager understand that the training has not been well provided. 72% of responders (Safety Managers) at field thinks that safety training has not been well provided at a site. It is shown that there are not any additional measures to correct this problem. Eventually, the reasons of that the training is not well provided, and foreign workers do not understand safe condition at site, well lead to an accident at construction site.

The Study On The Actual Condition Of Rebar Work In Korean Building Construction (국내 건설 현장의 철근공사 실태조사에 관한 연구)

  • 이응균;박우열;강경인
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.133-138
    • /
    • 2002
  • Rebar work takes up big proportion in a construction work. The current process of purchasing, cutting and election, and working of rebar induces a lot of loss in rebar. This study is focused on analyzing the problem and the present condition of the process from the calculating of rebar quantifies to the actual constructional stage through surveying those who have experience in the estimation department, or the construction site of a domestic construction company. Many reform measures such as diversification of standard(i.e., 8-meter)bar, calculation of rebar quantities and construction according to the rebar election drawing, expansion of accuracy in layout plan, thoroughness in examination of layout plan in advance, utilization of the worked material, systemization of rebar control(management), and a shift in attitude of the field(site) manager were proposed as the result of the survey.

  • PDF

Synecological Study on the Natural Reserve Forest for Academic Research in Gwangneung, Korea (光陵의 學術硏究保存林에 關한 群集生態學的 硏究)

  • Yim, Yang-Jai;Kum Soon Kim
    • The Korean Journal of Ecology
    • /
    • v.8 no.3
    • /
    • pp.147-152
    • /
    • 1985
  • The forest vegetation of natural reserve area (175ha) at north-eastern slope of Solibong (537m), Gwangneung, was studied by plant sociological method and two dimensional ordination technique. In the area dominated by Carpinus laxiflora, from the lower site to peak of Solibong, a zonal distribution of C. laxiflora-Quercus mongolic forest, C. laxiflora-C. cordata forest, C. laxiflora-Q. serrata forest, C. laxiflora forest and C. laxiflora-Rhododendron schlippenbachii forest were recognized by the plant sociological survey. It is seem that the optimal range of Carpinus laxiflora forest occur in mesic-warm site by two dimensiional ordination with thermal condition and soil moisture condition. The optimal range (over 100 in importance value) was the range of 76~89。C.month in warmth index and 18~45% in soil water content.

  • PDF

A Study on the Actual Condition of Electrical Construction Supervision and Countermeasure of It (전기분야감리제도의 운영실태 및 개선방안에 관한 연구)

  • 고선환;장우진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.147-150
    • /
    • 2002
  • Domestic electrical construction inspection system was introduced into building site in 1963 by registered architects' law, meanwhile, inspector appointed by ministry of owners lake charge of Government managing building site. Afterwards several systems has been adopted to heal some problems each of them has revealed. These times Government granted authority for inspection on surveillancer, furthermore, formulate a supervising system which articulate the responsibilities of supervision and put it in effect as of 1st, January, 1994. This supervision system gets rid of factors causing faulty work to a considerable extent. However, as it is still in early stage, the system has various problems to overcome, For example, actual state of handling modifications of design in accordance with supervision system in field shows a difference between process provided by law and field process. Thus this study inquire and analyze actual condition of supervision system, at the same time, problems occuring in modifications of design under supervision, and then propose a way to improve it

  • PDF

The Experimental Evaluation and Verification of a 300kW Small Engine Cogeneration System (300kW급 가스엔진 열병합발전시스템 성능평가 및 실증)

  • Choi, Jae-Joon;Park, Hwa-Choon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.332-337
    • /
    • 2009
  • The importance of the evaluation and verification of small-size cogeneration system has been emphasized because there is no KS-code related to the small-size cogeneration system. The evaluation method of small-size engine cogeneration system, regarding Japanese standard JIS B-8122 and international standard organization, ISO-8528, was applied to the system. The evaluation methods, start-test, rapid-load-up and rapid-load-down, etc. were executed at the system, and reasonable results were acquired. The electrical and thermal efficiencies were executed and analyzed at various load conditions. The NOx emission at various load condition was also measured. Finally, the gas engine cogeneration system was installed to a site for actual usage and it was continually operated during more than 6 months as the site condition.

  • PDF

The Effects of Design Parameters for Small Scale Hydro Power Plant with Rainfall Condation (강우상태에 의한 소수력발전소 설계인자의 영향)

  • Park, Wan-Soon;Lee, Chul-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.43-49
    • /
    • 2008
  • The effects of design parameters for small scale hydro power(SSHP) plants due to rainfall condition have been studied. The model to predict hydrologic performance for SSHP plants is used in this study. The results from analysis for rainfall conditions based on Weibull distribution show that the capacity and load factor of SSHP site had large difference between the variation of shape and scale parameter. Especially, the hydrologic performance of SSHP site due to variation of shape parameter varied more sensitive than the case of variation of scale parameter. And also, the methodology represented in this study can be used to decide the primary design specifications of SSHP sites.