• 제목/요약/키워드: Sirocco fan

검색결과 50건 처리시간 0.032초

ESPI를 이용한 에어콘용 시로코팬의 신뢰성평가

  • 김경석;강기수;양승필
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2002년도 정기학술대회
    • /
    • pp.253-260
    • /
    • 2002
  • This paper propose Electronic Speckle Pattern Interferometry(ESPI) for reliability evaluation of electronic device. Especially, vibration problem in a fan of air conditioner, motor of washing machine and etc. is important factor to design the devices. However, it is difficult to apply previous method, accelerometer to the devices with lightweight and complex geometry. ESPI, non-contact measurement technique is applied for vibration analysis of a sirocco fan inside air conditioner. Vibration mode shapes, natural frequency and the range of the frequency are decided and compared with that of FEM analysis. In mechanical deign of new product, ESPI is able to supply effective design information.

  • PDF

저소음 패키지 에어컨 실내외기 개발에 관한 연구 (Study on the Development for Low Noise Indoor and Outdoor Package Air-Conditioner)

  • 김장권
    • 대한기계학회논문집A
    • /
    • 제20권6호
    • /
    • pp.1913-1920
    • /
    • 1996
  • The purpose of this study was to reduce the airborne noise emitted from the package air-conditioner(PAC) therefore, the optimim design melthods of the fans and the flow-paths were investigated experimentally through the anlaysis of the nose problems caused by the conventional PAC system, and the fan performance tests and the systme resistance measurements of the parts which belong to the flow-paths of the PACwere used to study these noise problems. As a results, through the optimized flow-paths of the new PAC system with the lowset system resistance, and by adjusting and matching the operating point of each fan to each PAC system, the airborne noise reductions from the new indoor PAC and the outdoor one were achieved upto 5.5 dBA and 6.6 dBA respectively in overall noise level as compared with the conventional PAC system.

회전형 미세입자 분무장치의 입자 분포 특성에 관한 기초 연구 (A Basic Study on Particle Distribution Characteristics of Rotary Mist Spraying Device)

  • 유영선;장재경;김형권;김영화;이태석;오성식;진병옥;오경민;강태경
    • 생물환경조절학회지
    • /
    • 제28권4호
    • /
    • pp.454-460
    • /
    • 2019
  • 이 연구에서는 염수를 증발냉각법을 이용하여 담수를 생산할 목적으로 회전형 미세입자 분무장치를 설계 제작하여 회전체의 표면조도, BLDC 시로코 팬의 회전수 그리고 염수 공급량의 변화에 따른 분무입자의 크기와 분포 특성을 실험적으로 분석하고자 하였다. 회전체의 표면조도 $Ra=0.27{\sim}7.65{\mu}m$인 경우 분무입자 크기는 $0.117{\sim}1.360{\mu}m$ 였고, 분무입자의 90% 가 $0.50{\mu}m$ 이하인 것으로 나타났다. $Ra=12.70{\sim}22.84{\mu}m$인 경우에는 분무입자 크기가 $2.51{\sim}184.79{\mu}m$의 범위에 분포하였고, 분무입자의 98%가 $13.59{\mu}m$ 이하인 것으로 나타났다. BLDC 시로코 팬의 회전수가 분무입자의 크기와 분포에 미치는 영향을 분석하기 위하여 표면조도 $Ra=0.27{\mu}m$로 고정한 상태에서 염수 공급량을 일정하게 유지하면서 팬의 회전수를 3,800~5,600rpm 로 변화시켜가며 실험을 수행한 결과 염수 공급량이 2.77~8.28mL/min 인 경우에는 분무입자의 크기가 $0.314{\sim}0.541{\mu}m$의 범위에 분포하였다. 또한 염수공급량이 9.74mL/min 이고 회전수가 5,600rpm인 경우에는 분무입자의 98.23% 이상이 $2.51{\sim}13.59{\mu}m$의 범위에 분포하였다.

고층 아파트에서 응축기 적층문제 분석 (Analysis of the Condenser Stack Effect in a High-Rise Apartment Building)

  • 최석호;이관수;김인규;이동혁
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.796-803
    • /
    • 2004
  • The stack effect of a new type condenser installed in a high-rise apartment building was studied numerically A sirocco fan is introduced to the new type condenser instead of an axial flow In. The new type condenser intakes the cold air through the lower inlet and exhausts the hot air through the upper outlet. The effects of the building height and frontal wind on the performance of an air-conditioner were analyzed. The performance of an air-conditioner was evaluated by using COP (coefficient of performance) and CGPI (condenser group performance indicator). the hot air was exhausted by the new type condenser at an angle of 50$^{\circ}$ from the outer wall of the building. If there was no draft, the new type condenser installed in the high-rise apartment building had a good performance and its performance on each floor is not influenced by the stack effect. It is shown that the efficiency of the air-conditioner installed in several floors below the top floor decreased when the frontal wind velocity was greater than 8 m/s.

가전제품 홴 공력소음 특성 및 해석 (A Characteristics and Analysis of Aeroacoustic Noise for Appliance Fans)

  • 전완호;김창준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1140-1145
    • /
    • 2003
  • In this paper, some dominant aeroacoustic characteristics of fans used in appliances are reviewed. The numerical attempts to analyze tile aeroacoustic noise of fans are briefly reviewed for various fans. Axial fans for refrigerator, cross flow fans fer air-conditioner, sirocco fans and turbo fans are anal: zed. The unsteady flow field, which is essential data for aeroacoustic analysis, is calculated by commercial CFD code. Acoustic pressure is calculated by Ffowcs Williams and Hawkings equation and Lowson's equation. During the analysis, dominant noise sources are identified.

  • PDF

자동차 HVAC용 Blower Unit 내부 유동장의 PIV 계측 (PIV Measurement of Flow Inside of HVAC Blower Unit)

  • 지호성;김보람;이상준
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.165-173
    • /
    • 2007
  • Flow characteristics inside a blower unit of an automotive HVAC module were investigated experimentally using a high-resolution PIV technique. The PIV system consists of a 2-head Nd:YAG laser, a high-resolution CCD camera, optics and a synchronizer. The prototype siroco-fan with forward-curved blades was operated under the same condition of real car. The scroll casing was made transparently for capturing clear flow images. The time-averaged velocity fields were measured in three cross sections. Flow is accelerated with going toward the outer wall of scroll due to centrifugal force and large pressure gradient formed in the region between the fan and the outer casing wall. The presence of the cut-off region and diffusing duct of fan outlet influences largely the flow structure inside the blower unit.

전산해석에 의한 자동차용 HVAC 시스템의 성능 연구 (A Numerical Study for Performance of Automotive HVAC System)

  • 이대웅;유성연
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1084-1091
    • /
    • 2004
  • In automotive air handling system, mixing of air streams by the cooler and the heater affects the comfort of cabin room. In the present study, computer-aided analysis is done to improve the thermal comfort and for the optimal design of automotive HVAC system. The simulation software used was FLUENT, and complicate geometries were created by three dimensional CAD. Air flow volume, fir distribution rate and temperature controllability and temperature differences between upper and lower discharge air are analyzed through numerical simulation at vent, floor and defrost mode. Also, velocity vector of sirocco fan is investigated through the scroll housing. The velocity vector magnitude is larger at lower region of fan than that at any other regions. Recirculation and disturbance of air is relatively high near the cut-off edge in the scroll housing. By using the results of this study, the time for prototype production can be reduced and timely decisions can be made to determine initial design directions.

터널용 에어커튼 시스템의 내열 및 제연 성능 평가 연구 (The study on performance evaluation of heat resistance and smoke control system using air-curtain system in tunnel)

  • 박병직;신현준;유용호;박진욱;김양균;김휘성
    • 한국터널지하공간학회 논문집
    • /
    • 제20권4호
    • /
    • pp.743-755
    • /
    • 2018
  • 터널은 지하공간과 유사한 반밀폐 형태로서 화재 발생 시 연기가 빨리 차오르고 외부로 연기가 천천히 빠져나가는 구조이다. 이에 따라 교통사고로 인한 화재 발생 시 사고차량 뒤에 차량이 연속으로 정차되어 차량을 이용한 피난이 어려우며, 화재 현장에 소방차 진입이 어렵기 때문에 소화하기가 매우 어렵다. 따라서 국내외적으로 터널 방재등급을 설정하고 이에 맞는 방재시설을 설치하고 운영하고 있다. 우리나라 도로터널은 1 km 미만의 터널의 80.0%를 차지하고 있으며, 1 km 미만의 터널은 방재등급 3등급으로서 제연시설을 설치하지 않아도 된다. 본 연구에서는 내열시로코 팬을 이용한 에어커튼 시스템을 1 km 미만 터널에 제연설비로 활용하기 위해서 실물화재실험을 통하여 성능평가를 수행하였다. 이에 따라, $250^{\circ}C$의 온도에서 60분 이상 작동하는지 내열시험을 통해서 확인하였으며, 실물화재실험을 수행하여 에어커튼 내부(터널 화재방향)에서는 온도 및 이산화탄소 농도가 급격히 상승하였지만, 에어커튼 외부(터널 외기방향)에서는 초기의 상태를 유지하고 있는 것을 확인하였다.

에너지 절감형 항온항습기 운전 특성에 관한 연구 (Study on the energy-saving constant temperature and humidity machine operating characteristics)

  • 차인수;하민호;정경환
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.27-33
    • /
    • 2016
  • 본 연구에서 적용한 열회복 방식은 적은 동력사용으로 최대의 냉각능력을 낼 수 있는 에너지 절약형이다. 항온항습기의 온습도를 보다 정밀 한 제어 기능을 갖도록 하기 위해 제어 알고리즘은 퍼지 PID 제어기를 설계하여 적용하였고, 외기보상장치(공냉식)를 갖추어 동절기에 $-20^{\circ}C$에서도 우수한 제습능력을 발휘하게 하였다. 고효율, 저소음형 시로코 팬을 채용하여 정숙운전이 되며 장비특성에 따라 상향식과 하향식에 맞도록 설계하였다. 실험한 결과 변환 효율은 95%이상, 정전복귀는 5sec 이내, 정지지연은 30sec 이내, 펌프다운은 10sec, 펌프지연은 5sec, 히팅지연은 5sec, 온도편차는 ${\pm}2^{\circ}C$(냉방편차: $2^{\circ}C$, 난방 편차: $2^{\circ}C$), 습도편차는 ${\pm}5%$(가습편차 3.0%, 제습편차 3.0%)을 갖게 하였다. 최근 유비쿼터스 기술이 중요시 되고 있기에 핸드폰을 통해 항온항습기를 원격 제어 할 수 있도록 하였고, MMI 소프트웨어와 자동 인터페이스를 지원하여 확장성이 뛰어나게 하였다. 또한 지능형 컨트롤러 고장진단에 의한 부품 및 장비의 수명이 연장 되도록 하였다.