• Title/Summary/Keyword: Sinusoidal rotation

Search Result 41, Processing Time 0.031 seconds

Experimental Evaluation of Levitation and Imbalance Compensation for the Magnetic Bearing System Using Discrete Time Q-Parameterization Control (이산시간 Q 매개변수화 제어를 이용한 자기축수 시스템에 대한 부상과 불평형보정의 실험적 평가)

  • ;Fumio Matsumura
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.964-973
    • /
    • 1998
  • In this paper we propose a levitation and imbalance compensation controller design methodology of magnetic bearing system. In order to achieve levitation and elimination of unbalance vibartion in some operation speed we use the discrete-time Q-parameterization control. When rotor speed p = 0 there are no rotor unbalance, with frequency equals to the rotational speed. So in order to make levitatiom we choose the Q-parameterization controller free parameter Q such that the controller has poles on the unit circle at z = 1. However, when rotor speed p $\neq$ 0 there exist sinusoidal disturbance forces, with frequency equals to the rotational speed. So in order to achieve asymptotic rejection of these disturbance forces, the Q-parameterization controller free parameter Q is chosen such that the controller has poles on the unit circle at z = $exp^{ipTs}$ for a certain speed of rotation p ( $T_s$ is the sampling period). First, we introduce the experimental setup employed in this research. Second, we give a mathematical model for the magnetic bearing in difference equation form. Third, we explain the proposed discrete-time Q-parameterization controller design methodology. The controller free parameter Q is assumed to be a proper stable transfer function. Fourth, we show that the controller free parameter which satisfies the design objectives can be obtained by simply solving a set of linear equations rather than solving a complicated optimization problem. Finally, several simulation and experimental results are obtained to evaluate the proposed controller. The results obtained show the effectiveness of the proposed controller in eliminating the unbalance vibrations at the design speed of rotation.

  • PDF

Development of a Flywheel Energy Storage System using Superconducting Magnetic Bearing (초전도 플라이휠 에너지 저장시스템 개발)

  • 정환명;연제욱;최재호;고창섭
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.433-441
    • /
    • 1999
  • This paper presents a S-FES(Superconducting magnetic becuing Flywheel Energy Storage System) for the p purpose of replacing battery used to store the energy. Especially, the design elements of FES, such as the b beming, wheel mateηaI, and power converter, etc., are described. The design and manufacturing techniques of t the controllable IXlwer converter are proposed to generate the sinusoidal output current in the high speed operation and to get the const빠synchronous motor with halbach cuTay of high coesive I\d-Fe-B permanent magnet is used as the driver of F FES. The proposed S-FES system shows the stable rotation characteristics at high speed range about l 10,000[rpm]. To verify the validity of proposed system, the comparative study with the conventional ball b beming s~rstem is proceeded and it is well confirmed with the result of the lower friction losses of S-FES S system.

  • PDF

Unsteady Aerodynamic Characteristics depending on Reduced Frequency for a Pitching NACA0012 Airfoil at Rec=2.3×104

  • Kim, Dong-Ha;Chang, Jo-Won;Sohn, Myong Hwan
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.8-16
    • /
    • 2017
  • Most of small air vehicles with moving wing fly at low Reynolds number condition and the reduced frequency of the moving wing ranges from 0.0 to 1.0. The physical phenomena over the wing dramatically vary with the reduced frequency. This study examines experimentally the effect of the reduced frequency at low Reynolds number. The NACA0012 airfoil performs sinusoidal pitching motion with respect to the quarter chord with the four reduced frequencies of 0.1, 0.2, 0.4 and 0.76 at the Reynolds number $2.3{\times}10^4$. Smoke-wire flow visualization, unsteady surface pressure measurement, and unsteady force calculation are conducted. At the reduced frequency of 0.1 and 0.2, various boundary layer events such as reverse flow, discrete vortices, separation and reattachment change the amplitude and the rotation direction of the unsteady force hysteresis. However, the boundary layer events abruptly disappear at the reduced frequency of 0.4 and 0.76. Especially at the reduced frequency of 0.76, the local variation of the unsteady force with respect to the angle of attack completely vanishes. These results lead us to the conclusion that the unsteady aerodynamic characteristics of the reduced frequency of 0.2 and 0.4 are clearly distinguishable and the unsteady aerodynamic characteristics below the reduced frequency of 0.2 are governed by the boundary layer events.

A Motor/Generator for Flywheel Energy Storage System Levitated by Bulk Superconductor (초전도 부상 플라이휠 에너지 저장시스템의 구동을 위한 전동/발전기)

  • Go, Chang-Seop;Yeon, Je-Uk;Choe, Jae-Ho;Jeong, Hwan-Myeong;Hong, Gye-Won;Lee, Ho-Jin
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.411-420
    • /
    • 2000
  • The energy storage systems are being widely researched for the high quality of the electric power. The FES(flywheel energy system) is especially, on the center of the research because it does not make any pollution and its life is long. The FES converts the electrical energy into the mechanical kinetic energy of the flywheel and reconverts the mechanical energy into the electrical energy. In order to store as much energy as possible, the flywheel is supposed to be rotated with very high speed. The motor/generator of the FES should be high efficient at high speed, and generate constant torque with respect to the rotation. In this paper, a motor/generator employing a Halbach array of permanent magnets is designed and constructed to meet the requirements, and its characteristics are examined. The magnetic field is analysed by using the magnetic surface charge method. The armature winding is designed for the harmonic components to be minimized by using the FFT. The sinusoidal current for the motor driving are generated by the hysteresis current controller. A sample superconducting flywheel energy storage system is constructed with a duralumin flywheel which has a maximum rotating speed of 40,000[rpm] and a stored energy of 240[Wh] and its validity is examined through the experiment.

  • PDF

Buckling Loads and Post-Buckling Behaviors of Shear Deformable Columns with Regular Cross-Section (전단변형을 고려한 정다각형 단면 기둥의 좌굴하중 및 후좌굴 거동)

  • Lee, Byeoung Koo;Lee, Tae Eun;Kwon, Yun Sil;Kim, Sun Gi
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.6
    • /
    • pp.683-691
    • /
    • 2001
  • Numerical methods are developed for solving the elastica and buckling load of tapered columns with shear deformation, subjected to a compressive end load. The linear, parabolic and sinusoidal tapers with the regular polygon cross-sections are considered, whose material volume and span length are always held constant. The differential equations governing the elastica of buckled column are derived. The Runge-Kutta method is used to integrate the differential equations, and the Regula-Falsi method is used to determine the rotation at left end and the buckling load, respectively. The numerical methods developed herein for computing the elastica and the buckling loads of the columns are found to be efficient and reliable.

  • PDF

Effects of Electroacupuncture on the excitability in Medial Vestibular Nuclei of Rats (흰쥐의 내측 전정신경핵 흥분성에 대한 전침자극의 효과)

  • Kim, Jae-Hyo;Lee, Sung-Ho;Sohn, In-Chul;Kim, Young-Sun;Kim, Min-Sun
    • Korean Journal of Acupuncture
    • /
    • v.26 no.3
    • /
    • pp.27-42
    • /
    • 2009
  • Objectives : The vestibular system detects head movement and serve to regulate and maintain the equilibrium and orientation of the body. It is known that the vestibular imbalance leads to vestibular symptoms such as nausea, vomiting, vertigo and postural disturbance. The objectives of the present study were to examine a modification of the dynamic activities of medial vestibular nucleus (MVN) neurons following electroacupuncture (EA) of GB43 (Hyepgye). Methods : In Sprague-Dawley rats weighing $250{\sim}300g$, dynamic responses induced by sinusoidal whole body rotation about vertical axis at 0.2 Hz were observed in MVN of rats during EA of GB43 (Hyepgye) with 0.2 ms, 40 Hz and $600{\pm}200{\mu}A$. Also, expression of cFos protein was observed 2 hours after EA for 30 mins. Results : In dynamic response of vestibular neuron, the excitatory or inhibitory responses of gain were predominant in the ipsilateral MVN neurons during EA but not predominant in the contralateral MVN. Most neurons showing decreased gain were classified to inhibitory responses of spontaneous firing discharge during EA and ones showing increased gain were classified to excitatory response of spontaneous firing discharge during EA. Also, EA of the left GB43 (Hyepgye) for 30 mins produced the expression of cFos protein in MVN, inferior olive (IO) and solitary tract nuclei (SOL). Spatial expressions of cFos protein were predominant in the contralateral MVN, ipsilateral IO and bilateral SOL. Conclusion : These results suggest that the excitability of MVN neurons was influenced by EA of GB43 (Hyepgye) and EA may be related to the convergence on MVN.

  • PDF

Electroacupuncture of $GB_{43}$ Modulates Neuronal Activities in Medial Vestibular Nuclei of Rats (협계(俠谿)에 대한 전침자극이 흰쥐의 내측 전정신경핵 자발활동성에 미치는 효과)

  • Kim, Jae-Hyo;Park, Byung-Rim;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.25 no.3
    • /
    • pp.117-135
    • /
    • 2008
  • Objectives: It is known that the vestibular imbalance leads to vestibular symptoms such as nausea, vomiting, vertigo and postural disturbance. Since the non-labyrinthine inputs from the limbs and viscera converge on the vestibular nucleus neurons receiving signal from peripheral vestibular endorgan, acupuncture to the periphery may influence the activities of vestibular nuclear neurons and produce a therapeutic effect on the vestibulacr symptoms. The present study was to examine a modification and characteristics of the static and dynamic activities of medial vestibular nucleus (MVN) neurons following electroacupuncture (EA) of GB43' acupoint. Methods: In 54 Sprague-Dawley adult male rats weighing 250${\sim}$300g, spontaneous firing discharges and dynamic responses induced by sinusoidal whole body rotation about vertical axis at 0.2 Hz were observed in MVN of rats during EA of GB43' acupoint, located between the left 4th and 5th toe, which is the territory of sural and peroneal nerves, with 0.2 ms, 40 Hz and 600${\pm}$200 ${\mu}A$. Results: EA of the left GB43' acupoint induced modifications of spontaneous firing rates in 45% of MVN neurons recorded, and the percentage of modified neurons was 44% in type I, 52% in type II and 46% in non-type neurons. The excitatory or inhibitory responses of spontaneous firing discharges were predominant in the ipsilateral MVN neurons during EA. The excitatory response was abolished after EA but the inhibitory response was prolonged after EA in the ipsilateral MVN. The neurons of MVN showing modified spontaneous firing discharges by EA showed lower frequency (${\geq}$10 spikes/sec) of mean spontaneous firing rates than non affected ones. Conclusion: These results suggest that the neuronal activities of MVN neurons were influenced by EA of GB43' acupoint and the effects of EA may be related to the convergence of the peripheral vestibular inputs and ascending somatosensory inputs on MVN.

  • PDF

Surface Tribology of Total Ankle Joint Replacement (인공발목관절의 표면 마모 특성)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF

Development of a Cardiac Catheter Remote Control Robot Platform for Radiofrequency Ablation Intervention (고주파 절제술을 위한 심장전극도자 원격 제어 로봇 플랫폼의 개발)

  • Park, Jun-Woo;Song, Seung-Joon;Lee, Jung-Chan;Choi, Hyuk;Lee, Jung-Joo;Choi, Jae-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1417-1426
    • /
    • 2011
  • Radiofrequency ablation through cardiac catheterization is one of minimally invasive intervention procedures used in drug resistant arrhythmia treatment. To facilitate more accurate and precise catheter navigation, systems for robotic cardiac catheter navigation have been developed and commercialized. The authors have been developing a novel robotic catheter navigation system. The system is a network-based master-slave configuration 3-DOF (Degree-Of-Freedom) robotic manipulator for operation with conventional cardiac ablation catheter. The catheter manipulation motion is composed of the translation (forward/backward) and the roll movements of the catheter and knob rotation for the catheter tip articulation. The master manipulator comprises an operator handle compartment for the knob and the roll movement input, and a base platform for the translation movement input. The slave manipulator implements a robotic catheter platform in which conventional cardiac catheter is mounted and the 3-DOF motions of the catheter are controlled. The system software that runs on a realtime OS based PC, implements the master-slave motion synchronization control in the robot system. The master-slave motion synchronization performance tested with step, sinusoidal and arbitrarily varying motion commands showed satisfactory results with acceptable level of steady state error. The developed system will be further improved through evaluation of safety and performance in in vitro and in vivo tests.

Electrical Stimulation Can Facilitate Vestibular Compensation Following Unilateral Labyrinthectomy in Rats

  • Park, Byung-Rim;Kim, Jin-Ok;Kim, Min-Sun;Lee, Moon-Young;Kim, Jae-Hyo;Jin, Yuan-Zhe;Choi, Myung-Ae
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.2
    • /
    • pp.123-131
    • /
    • 2001
  • To investigate the effects of electrical stimulation on vestibular compensation, which is the recovery of vestibular symptoms following unilateral labyrinthectomy (UL), intermittent electrical stimulation was applied to the injured vestibular portion in Sprague-Dawley rats. Vestibuloocular and vestibulospinal reflexes, electrical activity and expression of c-Fos protein in medial vestibular nuclei (MVN) were measured with time following UL. Spontaneous nystagmus occurred with frequency of $2.9{\pm}0.2$ beats/sec at 2 hours after UL and disappeared after 72 hours. Electrical stimulation decreased the frequency of nystagmus significantly till 24 hours after UL. Roll head deviation was $107{\pm}9.7^{\circ}$ at 2 hours after UL and the deviation was maintained till 72 hours, but electrical stimulation decreased the deviation significantly 6 hours after UL. Resting activity of type I neurons in ipsilateral MVN to the injured vestibular side decreased significantly compared with control at 6 and 24 hours after UL, but the activity of type I neurons was recovered to control level by electrical stimulation at 24 hours after UL. Gain of type I neurons induced by sinusoidal rotation of 0.1 Hz decreased significantly till 24 hours after UL, but electrical stimulation restored the activity at 24 hours. The gain of type II neurons decreased significantly at 6 hours after UL, but electrical stimulation restored the activity. Expression of c-Fos protein was asymmetric between bilateral MVN till 24 hours after UL, but the asymmetry disappeared by electrical stimulation 6 hours after UL. These results suggest that electrical stimulation to the injured vestibular portion facilitates vestibular compensation following UL by restoration of symmetry of neuronal activity between bilateral vestibular nuclei resulting from increased activity in ipsilateral vestibular nuclei to the injured side.

  • PDF