• Title/Summary/Keyword: Sinusoidal Input Current

Search Result 192, Processing Time 0.023 seconds

Design and Simulation of High Efficiency PWM Modulation Method for Three-phase Matrix Converter (3상 매트릭스 컨버터의 고효율 변조방법 설계 및 시뮬레이션)

  • Lim, Hyun-Joo;Cha, Han-Ju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.337-344
    • /
    • 2012
  • A matrix converter is used for converting AC/AC power directly. In order to generate sinusoidal input/output waveform in matrix converter, it uses nine bidirectional switches and PWM modulation. This paper presents an analytical averaged loss model of matrix converter with DDPWM(direct duty ratio PWM) and proposes a new switching method for reducing switching losses. A Mathematical loss models with average magnitude of voltage/current are classed as conduction and switching loss. The proposed switching pattern is improved with existing DDPWM. To prove improved efficiency with proposed DDPWM, this paper compares losses between suggested switching pattern and conventional switching pattern using mathematical and simulation method. Each loss types are influenced by environmental factors such as temperature, switching frequency, output current and modulation method.

New High Efficiency Zero-Voltage-Switching AC-DC Boost Converter Using Coupled Inductor and Energy Recovery Circuit (결합 인덕터 및 에너지 회생 회로를 사용한 새로운 고 효율 ZVS AC-DC 승압 컨버터)

  • Park, Gyeong-Su;Kim, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.10
    • /
    • pp.501-507
    • /
    • 2001
  • In this paper, new high-efficiency zero voltage switching (ZVS) AC-DC boost converter is proposed to achieve power factor correction by simplifing energy recovery circuit. A lot of high power factor correction circuits have been proposed and applied to increase input power factor and efficiency. Most of these circuits may obtain unity power factor and achieve sinusoidal current waveform with zero voltage or/and zero current switching. However, it is difficult for them to obtain low cost, small size, low weight, and low noise. The topology proposed to improve these problems can compact the devices in circuit and can achieve high efficiency ZVS AC-DC boost converter. Simulation and experimental results show that this topology is capable of obtaining high power factor and increasing the efficiency of the system.

  • PDF

The Control of Three Phase High Power Factor PWM converter using Reduced - Order Luenberger Observer (축소차원 Luenberger 관측기를 이용한 3상 PWM 컨버터의 고역률 제어)

  • Yang, Lee-Woo;Kim, Young-Cho;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2478-2480
    • /
    • 1999
  • In this paper, the authors propose a current control system for three phase PWM AC/DC converter without the source voltage sensors. The sinusoidal input current and unity effective power factor are realised based on the estimated source voltage in the controller. The estimation of source voltage is performed based on Luenberger observer using actual currents. The estimated source voltage is used to accomplish unity power factor. The proposed method is proved by simulations.

  • PDF

Analysis on Induction Watthour Meter Performance With Frequency Variation (유도형 적산전력량계의 주파수 변화 특성해석)

  • Jang, S.M.;Lee, S.H.;Seo, J.H.;Jeong, S.S.;Park, Y.T.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.25-27
    • /
    • 1997
  • The precise measurement of consumed power for a given time is very important in the energy management aspect. Up to days, most power meter has been used and designed for use on circuits in which the voltage and current are essentially sinusoidal. Recently the increase of switching element in power system causes the current and voltage with harmonics. Therefore, power energy involving harmonics is supplied to the system and the error of power measurement of watthour meter is existed. In this paper, we present a characteristic analysis by input frequency variation and analytical basis of induction watthour meter considering harmonics.

  • PDF

Transformer-less Type Grid-Connected PV Power Conditioning System (변압기 없는 계통연계형 PV PCS고찰)

  • Jung, Young-Seok;Yu, Gwon-Jong;Jung, Myoung-Woong;Choi, Jae-Ho;Choi, Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.551-554
    • /
    • 2002
  • This paper describes a new interactive inverter between a photovoltaic(PV) array and single-phase utility that avoid the bulky input (60Hz) transformer on the AC side. The interface employs a pwm boost converter on the DC side followed by a pwm current-forced single-phase rectifier for injecting the power from the PV array into the mains. The current waveform at the AC side remains sinusoidal and exactly in phase at all time. The circuit also has the advantage of requiring fewer switching device than high-frequency link system. This paper describes modeling of PV array and new system topology. Simulation results on the performance of the connection are also presented.

  • PDF

Characteristics on the Harmonic Sensitivity of an Induction Watthour Meter (유도형 적산전력량계의 고조파 민감도 특성)

  • Jang, Seok-Myeong;Lee, Seong-Ho;Park, Yeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.587-596
    • /
    • 1999
  • The use of Switching elements in power systems causes the current or voltage to involve harmonic waves. Harmonics bring about registration errors of the equipment for measuring power. In case the induction watthour meter designed on sinusoidal source is used in the measurement of power with harmonics, the precise measurement of power has many problems because harmonics cause a decrease of power factor and vibration by the unstable driving force on the aluminum disc. In this paper, analysis and test results on the harmonic sensitivity of an induction watthour meter is reported when the input voltage and current with harmonics were supplied to single-phase watthour meter.

  • PDF

ZVZCS Single-Stage Power Factor Corrected Converter (영전압, 영전류 스위칭 1단 방식 역률 보상 AC/DC 컨버터)

  • Kang, Feel-Soon;Park, Sung-Jun;Kwon, Soon-Jae;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1348-1350
    • /
    • 2000
  • Zero-voltage and zero-current switched single-stage approach with high power factor is presented to reduce the switching losses and to achieve sinusoidal, unity power factor input currents. This single-stage approach, which combines a boost converter used as PFC with a half-bridge converter used as do to do conversion into one power stage, has a simple structure and low cost. At the same time, since the switches of the proposed converter are designed to be turned on at zero-voltage and off at zero-current, the switching losses could be reduced considerably. Detailed analysis and experimental results are presented on the proposed converter, which is operated at constant switching frequency and in discontinuous conduction mode.

  • PDF

Electrochemical Frequency Modulation: Solution Resistance and Double Layer Capacitance Considerations

  • Lalvani, Shashi;Ullah, Sifat;Kerr, Lei
    • Corrosion Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.231-241
    • /
    • 2021
  • The objective of this study was to evaluate total current under steady-state conditions for a material undergoing corrosion using the electrochemical frequency modulation (EFM) technique, taking into account the presence of solution resistance and double layer capacitance. The analysis involving linearization of the Tafel curve allowed for the estimation of corrosion parameters. Results showed that the output signal was dependent on fundamental frequencies and their multiples. In addition, the output signal almost manifested itself at frequencies that were sums of fundamental frequencies of the applied sinusoidal signal. The harmonics calculated showed a significant shift from the principal frequency of input signals. The investigation involved the influence of corrosion current and anode-to-cathode Tafel slope ratio on faradaic and non-faradaic currents (including the average and RMS). The model presented showed both qualitative and quantitative improvements over the previously developed EFM technique that ignored the influence of solution resistance and the double layer capacitance while assuming the applied DC potential corresponded to the corrosion potential of the corroding material.

The Speed Control for Direct Current Motors Using Matrix Converter Topology (매트릭스 컨버터 토폴로지를 이용한 직류전동기 속도제어)

  • Jeong, Bum-dong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.238-245
    • /
    • 2018
  • This paper proposes the applicability of matrix converter topology for the speed control of direct current motors. Matrix convertesr are divided into direct and indirect components. This paper utilizes an indirect matrix converter which is expected to be used widely because of making a variety of output side. The proposed converter has advantages which improves input current shape, has no large energy storage component causing short life. Simulation results are provided to verify effectiveness by comparing and analyzing features of the proposed and conventional topology. The proposed method shows similar performance for speed control, torque control, and load current control compared to a conventional method. Furthermore Harmonics are greatly reduced because the input current is controlled in a manner similar to sinusoidal wave by directly controlling switches at the rectifier stage.

Measurement of Transient Current by using the Rogowski Coil (로고우스키코일을 이용한 과도전류의 측정)

  • 이복희;길경석;정승수;정상진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1206-1213
    • /
    • 1994
  • This paper presents the operation principle and design rule of the Rogowski coil which can measure the transient current and describes the calibration and application experimental results for performance evaluation. It is obtained that the response curves of the Robowski coil with the turns of 300 and the passive integrator to sinusoidal input give a good linearity up to the frequency of 500 [kHz] and the current measurement system gaving the Rogowski coil is the frequency bandwidth of 40 [Hz]~700 [kHz]. As an application experiment for the fabricated modeling power transmission line, the impulse current, which limitates the direct lightning return stroke to overhead ground wire, is measured by the Rogowski coil and its fast Fourier transformation is carried out. The equivalent circuit of the Rogowski coil considering the stray capacitances is proposed, and the theoretical analysis is in good agreement with the measurement results. Also, it is found that for high frequency domain the stray capacitance such as a distributed capacitance to the shield and the capacitance between windings of coil should be considered in designing the Rogowski coils since the resonance originates from the stray capacitance and the self-inductance of the Rogowski coil.

  • PDF