• 제목/요약/키워드: Sink capacity

검색결과 106건 처리시간 0.027초

외부공기 유입관을 이용한 컴퓨터 냉각시스템의 효율향상에 관한 연구 (A Primary Study on the Enhancement of Efficiency in the Computer Cooling System using Entrance Tube of Outer Air)

  • 김순호;김문환
    • 동력기계공학회지
    • /
    • 제13권4호
    • /
    • pp.56-61
    • /
    • 2009
  • In recent years, since the continuing increase in the capacity in personal computer such as the optimal performance, high quality and high resolution image, the computer system's components produce large amounts of heat during operation. This study analyzes and investigates the ability and efficiency of a cooling system inside a computer by means of central processing unit (CPU) and power supply cooling fan. This research was conducted to enhancement of efficiency of the cooling system inside the computer by making a structure which produces different air pressures in an air inflow tube. Consequently, when temperatures of the CPU and room inside computer were compared with a general personal computer, temperatures of the tested CPU, the room and the heat sink were as low as $5^{\circ}C$, $2.5^{\circ}C$ and $7^{\circ}C$ respectively. In addition to, revolution per minute (RPM) was shown as low as 250 after 1 hour operation. This research explored the possibility of enhancing the effective cooling of high-performance computer systems.

  • PDF

동도금 EP방열판에 의한 소형LED조명등 방열 (Heat Radiation of LED Light using eu Plating Engineering Plastic Heat Sink)

  • 조영태
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.81-85
    • /
    • 2011
  • Recently, the electronic parts are to be thinner plate, smaller size, light weight material and CPU, HDD and DRAM in all the parts have been produced on the basis of the high speed and greater capacity. Also, conventional goods have replaced a LED (Light-Emitting Diode) in lighting products so; such industry devices need to have cooling. To maximize all the performance on the heat-radiated products, the area of heat-radiated parts is required to be cooled for keeping the life time extension and performance of product up. Existing cooling systems are using radiant heat plate of aluminum, brass by extrusion molding, heat pipe or hydro-cooling system for cooling. There is a limitation for bringing the light weight of product, cost reduction, molding of the cooling system. So it is proposed that an alternative way was made for bringing to the cooling system. EP (Engineering Plastic) of low-cost ABS (Acrylonitrile butadiene styrene Resin) and PC (Polycarbonate) was coated with brass and the coating made the radiated heat go up. The performance of radiant heat plate is the similar to the existing part. We have studied experimentally on the radiated heat plate for the light-weight, molding improvement and low-cost. From now on, we are going to develop the way to replace the exiting plate with exterior surface of product as a cooling system.

최대 수용량-기반 최소절단 알고리즘 (Maximum Capacity-based Minimum Cut Algorithm)

  • 이상운
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권5호
    • /
    • pp.153-162
    • /
    • 2011
  • 최소 절단 문제는 공급처 S에서와 수요처 T로의 흐름 용량이 최소가 되는 지점들을 절단하는 문제이다. 망의 병목지점을 찾는 방법은 대부분 유동망을 계산하여 최소 절단값을 찾는 유동-기반 알고리즘이 적용되고 있다. 이 알고리즘은 최소절단은 제시하지 않는 단점이 있다. 본 논문은 유동망을 구하지 않고 망으로부터 직접 최대 수용량을 가진 정점을 인접한 S 또는 T로 병합하는 방법으로 최소 절단값을 찾는 간단한 알고리즘이다. 13개의 한정된 그래프에 적용한 결과 제안된 알고리즘은 간단하면서도 정확하게 최소 절단 값 $_{\min}c$(S, T)을 찾을 수 있었다.

열전모듈을 이용한 에어컨의 방열부 냉각특성에 대한 연구 (Cooling Characteristics at Hot Side of the Thermoelectric Module for an Air Conditioner)

  • 김서영;강병하;장혁재;김석현
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.214-220
    • /
    • 2002
  • A small air conditioner using thermoelectric module has been designed and built. Three types of cooling methods, such as air cooling, closed-loop water cooling, and evaporative cooling, for hot side of thermoelectric module have been investigated. Among three types of cooling method, the evaporative cooling method is seen to be the most effective to achieve the steady state operation of a thermoelectric air conditioner The system performance with evaporative cooling method are also studied in detail for several oprating parameters, such as input power to the thermoelectric module, water or air flow rate at the hot side, and air flow rate at the cold side. The results obtained indicate that the cooling capacity of a system is increased with an increase in the input power to the thermoelectric module while the system COP is decreased. It is also found that the optimal air flow rate as well as water flow rate at the hot side is needed for the best system performance at a liven operating condition. Both the system COP and cooling capacity are increased as the air flow rate at cold side is increased.

통신 품질 향상을 위한 최단 시간 경로 알고리즘 (Quickest Path Algorithm for Improving Quality of Services in Communication Networks)

  • 윤석환;김평중;김진수
    • 품질경영학회지
    • /
    • 제26권1호
    • /
    • pp.192-200
    • /
    • 1998
  • The quickest path problem is one of the important things for quality of services in communication networks. It is to find a path to send a given amount of data from the source to the sink with minimum transmission time, where the transmission time is dependent on both the capacities and the traversal times of the arcs in the network. This is found under the networks that the capacity and the lead time of each ring are predetermined. It is general to solve the quickest path problem using shortest path algorithms. The relevant algorithms proposed till now are based on the capacity of rings in distributed environments. When the configuration of networks is changed, there can be two a, pp.oaches to find the quickest paths. The one is to find new quickest paths, and the other is to update the current quickest paths. As one of the algorithms for the latter, the distributed quickest path update algorithm was proposed. This paper aims to propose the distributed algorithm a, pp.icable to find the quickest path, when the configuration of networks is changed, using the quickest path tree update altorithm, and to verify its possibility of a, pp.ication by analyzing the transmission amount of data from one node to another from the theoretical point of view.

  • PDF

사무용건물에서 지열히트펌프냉난방시스템의 운전성능 평가 (Performance for Geothermal Heating & Cooling System by Heatpump in Office Building)

  • 안형준;백성권;조정식;손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권1호
    • /
    • pp.23-29
    • /
    • 2007
  • For the perfomance test of geothermal system, a large pilot of capacity of 50RT is built and operated in office building. This system is planed hybrid system with cooling tower as asisstance heat sink. From October, 2004 to September, 2005, this system is operated andmonitored. As the result, COP of heating periods is about 3.46 and COP of cooling periods is about 4.1. Therefore, geothermal system is useful and suitable in Korea.

  • PDF

펠티어 냉난방시스템 최적화 기술에 관한 연구 (A Study on Optimization Development of Peltier Air-conditioning System)

  • 박상훈;정수진;박영우;박유경;송범중
    • 융복합기술연구소 논문집
    • /
    • 제3권1호
    • /
    • pp.19-23
    • /
    • 2013
  • This study is concerned with air-conditioning system in use of thermoelectric device. It is introduced that the well designed structures for better cooling & heating performance with high efficiency. And also it is performed that the system performance test of four types trial products for the use of hybrid commercial vehicle. System performance is affected by many component parts, especially heat sink design & power control method. It is applied that dual extrusive fin tube with buffer zone for the effective radiating of circulating liquid in tube. And also it is applied that power supply method with constant-current system. It is attained that system cooling capacity is 1.2kW, COP is 0.95.

  • PDF

충적대수층을 이용한 지열히트펌프시스템의 냉방성능 (Cooling Performance of Geothermal Heat Pump using Alluvium Aquifer)

  • 강병찬;박준언;이철우;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.561-566
    • /
    • 2009
  • Alluvium is sedimentary stratum and composed of gravel, sand, silt, clay. Permeability of alluvium is the higher. If alluvium have lots of aquifer, will be of great use heat source and heat sink of heat pump. Alluvium aquifer contain the thermal energy of surrounding ground. Also geothermal heat pump using alluvium aquifer reduce expenses than general geothermal heat pump, because geothermal heat pump using alluvium aquifer make use of single well. In this study geothermal heat pump using alluvium aquifer was installed and tested for a building. The heat pump capacity is 30USRT. Temperature of ground water is in $12{\sim}17^{\circ}C$ annually and the quality of the water is as good as living water. The heat pump cooling COP is 4.4 ~ 4.7. The system cooling COP is 3.25 ~ 3.6. This performance is as good as BHE type ground source heat pump.

  • PDF

반도체 패키지 EMC의 열물성 연구 (Thermophysical Properties of Epoxy Molding Compound for Microelectronic Packaging)

  • 이상현;도중광;송현훈
    • 반도체디스플레이기술학회지
    • /
    • 제3권4호
    • /
    • pp.33-37
    • /
    • 2004
  • As the high speed and high integration of semiconductor devices and the generation of heat increases resulted in the effective heat dissipation influences on the performance and lifetime of semiconductor devices. The heat resistance or heat spread function of EMC(epoxy molding compound) which protects these devices became one of very important factors in the evaluation of semiconductor chips. Recently, silica, alumina, AlN(aluminum nitride) powders are widely used as the fillers of EMC. The filler loading in encapsulants was high up to about 80 vol%. A high loading of filler was improved low water absorption, low stress, high strength, better flowability and high thermal conductivity. In this study, the thermal properties were investigated through thermal, mechanical and microstructure. Thermophysical properties were investigated by laser flash and differential scanning calorimeter(DSC). For detailed inspection of materials, the samples were examined by SEM.

  • PDF

광합성산물의 아포플라스트 체관부적재 기작 (Apoplastic Phloem Loading of Photoassimilate)

  • 김성문;허장현;한대성
    • 한국잡초학회지
    • /
    • 제17권4호
    • /
    • pp.345-361
    • /
    • 1997
  • Photoassimilates translocate from regions of carbohydrate synthensis(source) to regions of carbohydrate utilization or storage(sink). In the source, assimilate loads into the phloem for long-distance transport. Current evidence suggests that there are twig loading mechanisms : one involves assimilate transfer via the apoplasm and then load into the phloem by carrier-mediated proton-sucrose cotransport, while the other involves movement through the continuous symplastic connections between the mesophyll cells and the phloem. Inspite of problems associated with the interpretation of experiments, the evidence for apoplastic loading remains convincing because the apoplastic loading systems explains well the observed accumulation capacity arid the selectivity of assimilate uptake by tile phloem.

  • PDF