• 제목/요약/키워드: Single-stage operation

검색결과 268건 처리시간 0.029초

방화문의 내화성능 향상을 위한 3단 문 결속기 연구개발 (Research and development of a three-stage door binder to improve the fire resistance of fire doors)

  • 임보혁;이주원;조동환;이해열
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.157-158
    • /
    • 2023
  • Doors that are opened and closed when entering or exiting a general building are connected to the door frame and open and close. They are equipped with door locking devices of various structures, and are either locked to the door frame for the closing operation or released from the door frame for the opening and closing operation. Here, a single-stage door binding device having a door latch that is independently disposed at the center of one axis of the door is commonly used. On the other hand, if the size of the door is over a certain size or if the door is medium to large, the opening and closing operation may not be performed smoothly with only a single stage binder, or the closing state may not be achieved stably during the closing operation. In particular, in the case of the single-stage binding device provided in medium to large fire doors, the door is fixed to the door frame unstable, causing fatal errors in the fire prevention function of the fire door. Accordingly, in order to fundamentally solve these problems, we researched and developed a three-stage door binding machine that combines a top and bottom fastening structure with a single-stage fastening structure. This 3-stage door binder not only has the fire resistance performance of a fire door, but also has a T-shaped terminal in its fastening method, so if you eliminate the upper and lower fastening, it is a 1-stage binder like a regular product, but if you remove the door latch of the 1st-stage binder, it functions as an upper and lower 2-stage binder and forms a single mold. We researched and developed a three-stage door binder that can manufacture and produce three products at the same time, satisfying both product performance and price.

  • PDF

Modified Ac-Dc Single-Stage Converters

  • Moschopoulos, Gerry;Liu, Yan;Bassan, Sondeep
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.44-54
    • /
    • 2007
  • Ac-dc power conversion can either be done with two separate converter stages or with a single converter stage. Two-stage ac-dc converters, however, can be costly and complex, while the performance of single-stage converters is compromised due to a reduced number of components. Several researchers have therefore proposed adding some sort of auxiliary circuit consisting of a second switch and some passive elements to single-stage converters to improve their performance. Although these modified single-stage converters may have two converters, they are not two-stage converters as they do not have two separate and independently controlled converters that are always operating to convert power from one form to another. In this paper, the operation of ac-dc single-stage converters is first reviewed and their strengths and weaknesses are noted. The operation of several modified single-stage converters, including one proposed by the authors, is then discussed, and the paper concludes by presenting experimental results that confirm the feasibility of the proposed converter.

Surgical Strategy for Primary Colorectal Carcinoma and Synchronous Pulmonary Metastasis Resection

  • Kim, Tae Yeon;Cho, Jong Ho;Choi, Yong Soo;Kim, Hong Kwan;Kim, Jhin Gook;Shim, Young Mog
    • Journal of Chest Surgery
    • /
    • 제55권1호
    • /
    • pp.37-43
    • /
    • 2022
  • Background: The surgical strategy for single-stage resection of primary colorectal cancer (CRC) and synchronous pulmonary metastases remains a matter of debate. Methods: Perioperative data of patients who underwent single-stage resection of primary CRC and synchronous pulmonary metastases were compared to those of patients who underwent 2-stage resections. The demographic data, number of metastases, type of pulmonary and colorectal resections, operation time, blood loss, postoperative complications, morbidities, mortality, medical costs, and length of hospital stay were analyzed. Results: Twenty-two patients underwent single-stage resection of primary CRC and pulmonary metastases, while 27 patients underwent 2-stage resection. Tumor size and the number of pulmonary metastases were not significantly different between the 2 groups. The extent of pulmonary metastasectomy and abdominal procedures were similar in both groups, as was the thoracic surgical approach (video-assisted thoracic surgery vs. thoracotomy). However, open laparotomy was performed more frequently in the 2-stage group than in the single-stage group (p=0.045), which also had a longer total anesthetic time (p=0.013). The operation time, medical costs, estimated blood loss, complication rates, and severity were similar in both groups, but the length of hospital stay was shorter in the single-stage group (p<0.001). Conclusion: Single-stage colorectal and pulmonary resection shortened the overall hospital stay, with no significant changes in operation time, medical costs, hospital mortality, and morbidity. Therefore, single-stage resection could be a good surgical strategy in selected patients.

적은 소자수를 갖고 전해커패시터가 없는 단일단 인터리브드 토템폴 전기자동차 탑재형 충전기 (A Reduced Component count Single-stage Electrolytic Capacitor-less Interleaved Totem-pole On-board Battery Charger)

  • 김병우;조우식;최세완
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.510-516
    • /
    • 2017
  • This paper proposes a single-stage interleaved totem-pole on-board battery charger with a simple structure and a reduced component count. Apart from achieving ZVS turn-on of all switches and ZCS turn-off of all diodes, this charger does not require an input filter due to its CCM operation and bulky electrolytic capacitors, which in turn result in a high power density. A single-stage power conversion technique is applied to the interleaved structure in order to achieve a high power density and high efficiency. A 2.5 kW prototype of the proposed charger is also built and tested to validate the proposed operation.

A Novel PCCM Voltage-Fed Single-Stage Power Factor Correction Full-Bridge Battery Charger

  • Zhang, Taizhi;Lu, Zhipeng;Qian, Qinsong;Sun, Weifeng;Lu, Shengli
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.872-882
    • /
    • 2016
  • A novel pseudo-continuous conduction mode (PCCM) voltage-fed single-stage power factor correction (PFC) full-bridge battery charger is proposed in this paper. By connecting a freewheeling transistor in parallel with an input inductor, the PFC cell can operate in the PCCM with a constant duty ratio. Thus, the dc/dc stage can be designed using this constant duty ratio and the restriction on the duty ratio of the PFC cell is eliminated. As a result, the input current distortion is less and the dc bus voltage becomes controllable over the wide output power range of the battery charger. Moreover, the operation principle of the dc/dc stage is designed to be similar to that of a conventional phase-shifted full-bridge converter. Therefore, it is easy to implement. In this paper, the operation of the new converter is explained, and the design considerations of the controller and key parameters are presented. Simulation and experimental results obtained from a 1 kW prototype are given to confirm the operation of the proposed converter.

Operation of a High-T$_c$ Rapid Single-Flux-Quantum 4-stage Shift Register

  • Park, J.H.;Kim, Y.H.;Kang, J.H.;Hahn, T.S.;Kim, C.H.;Lee, J.M.
    • Progress in Superconductivity
    • /
    • 제1권2호
    • /
    • pp.105-109
    • /
    • 2000
  • We have designed and fabricated a single-flux-quantum(SFQ) four-stage shift register using YBCO bicrystal Josephson junctions, and tested its operations using a digital measurement set-up. The circuit consists of 4 shift register stages and a read SQUID placed next to each side of the shift register. Each SQUID was inductively coupled to the nearby shift register stage. The major obstacle in testing the circuits was the interference between the two read SQUIDs, and we could get over the problem by determining the correct operation points of the SQUID from the simultaneously measured modulation curves. Loaded data ('1' or '0') were successfully shifted from a stage to the next by a controlled current pulse injected to the bias lines located between the stages, and the corresponding correct data shifts were observed with the two read SQUIDs.

  • PDF

단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석 (Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System)

  • ;박성룡
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

고온 초전도 경사형 모서리 접합을 이용한 4단 쉬프트 레지스터의 동작 (Operation of a Single Flux Quantum 4-stage Shift Register Fabricated with High $T_c$ Ramp-edge Junction Technology)

  • 김준호;박종혁;김상협;정구락;강준희;성건용;한택상
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.83-86
    • /
    • 2001
  • We have fabricated a single flux quantum 4-stage shift register with interface-controlled $Y_1$$Ba_2$$Cu_3$$O_{7-x}$(YBCO) Josephson junction. The YBCO Josephson junctions showed RSJ-like current-voltage(I-V) curves at temperatures 45~80K. We tested load and shift operation of shift register with binary data sequences “1000”, “1010”, “1011”, and “1111” at 58K. For all the binary data sequences, the shift register operated successfully. By operating the circuit with proper current pulses, we observed no errors during at least 12 hours operation for all the data sequences.s.

  • PDF

Direct Single-stage Power Converter with Power Factor Improvement for Switched Mode Power Supply

  • Kalpana, R.;Singh, Bhim;Bhuvaneswari, G.
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.468-476
    • /
    • 2010
  • This paper presents a direct single-stage power converter using single-phase isolated full-bridge converter modules, with inherent power factor correction (PFC) for a 12 kW switched mode power supply (SMPS). The advantages of the proposed converter are its simple control strategy, reduction in number of conversion stage, low input line current harmonics, and improvement in power factor. Analysis of the single-stage converter is carried out in continuous conduction mode of operation. Steady-state analysis of the proposed converter is conducted to obtain converter parameters. A systematic design procedure is also presented for a 12k W converter with a design example. The effect of load variation on SMPS is also studied in order to demonstrate the effectiveness of the proposed converter for the complete range of load conditions. A set of power quality indices on input ac mains for an SMPS fed from a single-stage converter is also presented for easy comparison of their performance.

The Output Ripple Current of Single-Stage Flyback Converter with High Power Factor in LED Driver

  • Park, In-Ki;Eom, Hyun-Chul
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.347-349
    • /
    • 2013
  • This paper describes analysis and calculation of line frequency ripple current according to output capacitor value and effects of LED connection in the single stage flyback converter with high power factor. The low frequency output ripple current delivered from single stage converter has been analyzed in detail and the method evaluating parasitic resistance included in LED has been provided. In order to verify the equation derived in this paper, the single stage flyback converter has been designed with constant output current regulation with DCM operation. Experiments were conducted with different LED load structures to analyze the effect of LED parasitic resistance on output ripple current. As test results, the calculation can provide guide line to select capacitor values depending on output ripple current and LED characteristics.

  • PDF