• Title/Summary/Keyword: Single-System Design

Search Result 2,430, Processing Time 0.03 seconds

Test Methodology for Multiple Clocks Single Capture Scan Design based on JTAG IEEE1149.1 Standard (IEEE 1149.1 표준에 근거한 다중 클럭을 이용한 단일 캡쳐 스캔 설계에 적용되는 경계 주사 테스트 기법에 관한 연구)

  • Kim, In-Soo;Min, Hyoung-Bok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.980-986
    • /
    • 2007
  • Boundary scan test structure(JTAG IEEE 1149.1 standard) that supports an internal scan chain is generally being used to test CUT(circuit under test). Since the internal scan chain can only have a single scan-in port and a single scan-out port; however, existing boundary test methods can not be used when multiple scan chains are present in CUT. Those chains must be stitched to form a single scan chain as shown in this paper. We propose an efficient boundary scan test structure that adds a circuit called Clock Group Register(CGR) for multiple clocks testing within the design of multiple scan chains. The proposed CGR has the function of grouping clocks. By adding CGR to a previously existing boundary scan design, the design is modified. This revised scan design overcomes the limitation of supporting a single scan-in port and out port, and it bolsters multiple scan-in ports and out ports. Through our experiments, the effectiveness of CGR is proved. With this, it is possible to test more complicated designs that have high density with a little effort. Furthermore, it will also benefit in designing those complicated circuits.

A Basic Study on the Effect of the Wind Pressure according to Form on the Flat Roof mounted PV System (평지붕 PV거치 시스템의 형태에 따른 풍압영향에 관한 기초연구)

  • Yun, Doo-Young;Lee, Eung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.105-112
    • /
    • 2013
  • The new renewable energy became popular as a clean and sustainable alternative energy under the circumstances that the entire world is facing severe abnormal climate due to the use of fossil fuel, and among which, solar energy can be obtained anywhere and is not difficult to apply it into the existing buildings, which makes it possible to be widely distributed. However, as PV module is installed into a single plate system, it shows structural weaknesses which are vulnerable to wind load and give loss to design elements in external appearance. Accordingly, this study planned one-step parallel system to complement the problems occurring from a single plate system and used STAR-CCM+ V.8 made by CD-Adapco, a computational fluid dynamics(CFD) simulation tool to measure wind load stability and support based on the design standards for a single plate system and one-step parallel system. Building height was limited to less than 10m and wind speed was given when increasing from 35m/s to 50m/s by 5m/s on PV system installed into the flat roof. In this case, our analysis suggested that step-one parallel system was in class 7-9 according to Beaufort's wind power classification, which did not have an impact on the fixed PV system, and the single plate system is considered to cause risks in designing wind speed in central districts because it is more than wind power class 12.

A study on digital control of the single-rod hydraulic cylinder using variable (가변구조이론을 이용한 편로드 유압실린더의 디지탈제어)

  • 이교일;김동춘
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1133-1138
    • /
    • 1991
  • A control of nonlinear system is motivated by the fact that all real plants are nonlinear systems and model identification introduces parameter errors. The purpose of this study is to design a Discrete Variable Structure Controller(DVSC) for single-rod hydraulic cylinder system. The model contains uncertain parameters which we known to lie upper and lower bounds. In the design of DVSC, the boundary layer concept was adopted to reduce cattering. The DVSC was evaluated through digital computer simulation and compared with a VSC (analog controller).

  • PDF

Half Bridge Inverter for Single Phase Induction Motor Driving (단상 유도 전동기를 위한 하프브리지 인버터)

  • 이종규;김영삼;원영진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.181-183
    • /
    • 1999
  • This paper is about the design of half-bridge inverter controller with low cost and simple configuration for low power single-phase induction motor driving. The simple controller is composed of MCU and PLD. Also, to limit the overcurrent at initial driving, auxiliary function is added, and stabilizes the system. In order to verify the performance of the proposed methode, we design 500W inverter system, and in result, the response time of the proposed method compared with line voltage driving method is reduced by 200[msec].

  • PDF

Controller design for single link robot with flexible joint using nonlinear observer (비선형 관측기를 이용한 유연한 관절을 가진 로봇 팔의 제어기 구성)

  • Lee, Jang-W.;Seo, Jin-H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1128-1130
    • /
    • 1996
  • A canonical form observer design method for nonlinear systems is studied. Through this method, an observer of single link robot system with flexible joint is proposed. It is shown through simulation that the system can be stabilized when using the nonlinear feedback linearizing controller and the supposed observer.

  • PDF

A Design of Realtime Monitoring System of Automatic gas Control DC-MOTOR for Single Crystal($A1_2O_3$) growth (단결정($A1_2O_3$) 성장을 위한 자동가스 조절용 DC-MOTOR의 실시간 모니터링 시스템 구현)

  • Lee, Hyung-Chung;Park, Chong-Kug;Cho, Hyeon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2489-2491
    • /
    • 2004
  • DC-Motor is needed more and more sophisticated control to follow the highest precision of industrial automation and used in a number of control equipment or industrial fields. It is also useful to control single crystal($A1_2O_3$) growth. It is possible to procure a quality crystal utilizing a DC-Motor, if you mix Hydrogen and Oxygen gas properly and keep proper temperature in accordance with time process. In this paper, we will study about electrical valve positioning system for the gas mixture to improve the quality of single crystal($A1_2O_3$) growth and we will design about realtime monitoring systems of the automatic gas control DC- Motor for single crystal($A1_2O_3$) growth.

  • PDF

A Study on the Modeling and Design of Single Phase Induction Generators

  • Kim Cherl-Jin;Lee Kwan-Yong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.331-336
    • /
    • 2005
  • With increasing emphasis on non-conventional energy systems and autonomous power generation, development of improved and appropriate generating systems has recently taken on greater significance. This paper describes the performance analysis of a single phase self-excited induction generator (SEIG), suitable for autonomous/standby power systems. The system is also appropriate for wind energy systems and small portable systems. Both windings of the induction machine, the main and the auxiliary, are utilized. One winding will be devoted to the supply excitation current only, by being connected to the excitation capacitor, while the load is connected across the other winding. As the design of excitation, the minimum of self-excited capacitor connected auxiliary winding is determined as the suitable value using a circuit equation of auxiliary winding. For the steady state analysis, the equivalent circuit of the single-phase induction generators is used as a basis for modeling using the double-revolving field theory. The validity of the designed generator system is confirmed by experimental and computed results.

The conceptual design and analysts of three phase superconducting fault current limiter (일체형 삼상 고온 초전도 한류기의 단락 특성 해석)

  • Lee, Sueng-Je;Lee, Chan-Joo;Lee, Chang-Yul;Jang, My-Hye;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.94-97
    • /
    • 1998
  • The conceptual design of integrated three phase superconducting fault current limiter (SFCL) is presented. And through simulation of power system where this SFCL is installed, the characteristics of this SFCL is analyzed. It is like three-phase transformer. So it has the same characteristics with inductive single phase SFCL. But it has more merits than single phase SFCL. Differently to single phase SFCL, integrated three phase SFCL induces impedance at all phase by any single phase fault to protect the power system more safely.

  • PDF

The Development of Optimal Design and Control System for Ultra-Precision Positioning on Single Plane X-Y Stage (평면 X-Y 스테이지의 초정밀 위치결정을 위한 최적 설계 및 제어시스템 개발)

  • 한재호;김재열;심재기;김창현;조영태;김항우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.348-352
    • /
    • 2002
  • a basis such as IT(Information Technology), NT(Nano Technology) and BT(Bio Technology). Recently, NT is applied to various fields that are composed of science, industry, media and semiconductor-micro technology. It has need of IT that is ultra-precision positioning technology with strokes of many hundreds mm and maintenance of nm precision in fields of ultra micro process, ultra precision measurement, photo communication part and photo magnetic memory. This thesis represents optimal design on ultra-precision positioning with single plane X-Y stage and development of artificial control system for adequacy of industrial demand. Also, dynamic simulation on global stage is performed by using ADAMS (Automated Dynamic Analysis of Mechanical System) for the purpose of grasping dynamic characteristic on user designed X-Y global stage. The error between displacements from micro stage and from FEM(Finite Element Method) is 3.53% by verifications of stability on micro stage and control performance. As maximum Von-mises stress on hinge of micro stage is 5.981kg/mm$^2$ that is 1.5% of yield stress, stability on hinge is secured. Preparing previous results, optimal design of micro stage can be possible, and reliance of results with FEM can be secured.

  • PDF

A Comparison Study between Composite and Multiple Single-Segment Profile Control (Profile의 Composite와 Multiple Single-Segment Control의 비교 연구)

  • Kim, Jun-Ho;Chang, Sung-Ho;Ra, Doo-Wan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.4
    • /
    • pp.1-6
    • /
    • 2016
  • As manufacturing industries become globalized, product design affects every area of organization. The design sets the goals for a number of different departments, so if it fails to effectively communicate these goals, the entire organization is less efficient. In addition, To communicate clearly, the design must represent a product that meets its technical specification. GD&T (Geometric Dimensioning and Tolerancing) is one of the most important factors, which has an effect on efficiency of manufacture system, in designing products. However, most of designers in different industries are prone to ignore the importance of GD&T. To analyse the importance of GD&T compliance with international standards for design drawing, a comparison analysis of the difference between two methods, composite profile control and multiple single segment profile control, is performed on three different cases and suggests how it used to be more suitable. Composite profile tolerance is specified by a dual feature control frame that has one profile symbol specified with two lines of tolerance information. Whereas a multiple single segment profile control is when two or more single segment profile callouts are used to define the location and/or orientation and/or size and/or form of a part feature. In this study, the following results will be provided : a clear definition and an obvious difference of the tolerance zone, datums and datums sequence and minimization of tolerances. On this study, composite profile tolerance and multiple single segment profile tolerance were discussed. Next steps of research will consist on reaching more accurate results for profile control. Further research will be focused on dealing with the remaining 14 symbols of GD&T.