A study on the transient characteristics in Single-phase Line-start Permanent Magnet (단상 유도동기 전동기(LSPM)의 과도 특성에 관한 연구)

  • Jung, Dae-Sung;Lee, Ju;Ree, Cheol-Jick
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.631-632
    • /
    • 2006
  • This paper is written by research for the transient characteristics of the Single-phase Line-start permanent Magnet. The Single-phase Line-start permanent Magnet is most likely to substitute for Single-phase Induction Motor which is used about many appliance currently, because that has good points. For example, It has a Line-start of ability and a High-efficiency. And it need not power convergence device. The rotor of The Single-phase Line-start permanent Magnet has cage-bar with permanent magnet. This motor is started by cage-bar. When it entered synchronous condition, the rotor is rotated by the permanent magnet. But the design of the permanent magnet is very important, because the breaking torque of the permanent magnet interrupt to start a rotor. Finally, if Flux Barrier is not concerned, we do not get result of our object. Therefore this thesis is concerned about Flux Barrier.

  • PDF

A Single Phase Inverter Using the Central Arm (Central Arm을 이용한 Full-Bridge 단상 인버터)

  • Lee, Ho;Lee, Hwa-Choon;Kim, Seung-Ryong;Park, Sung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.78-84
    • /
    • 2011
  • In this paper, the switching frequency and THD for the reduction instead of traditional single phase inverter using a new type of central arm of the single phase inverter is proposed. The proposed single phase inverter topology, the existing one to add a arm by two-way central switch 3-level output voltage can be raised and, central arm, especially one or two of the switches by using a switch to the diode current switching algorithm was simplified. During the dead time because of this, depending on the direction of the current level does not appear in any other existing level compared to the inverter output voltage level of the THD has the advantage that less can be. The simulation and experimental results verified the validity of the proposed topology.

Drive of Single-phase Switched Reluctance Motors Using Search Coils (서치코일을 이용한 단상 SRM의 구동)

  • Shin, D.S.;Yang, H.Y.;Lim, Y.C.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.750-753
    • /
    • 2005
  • This paper presents a method of detecting rotor position for single phase Switched Reluctance Motors(SRMs) using searchs coil. In the single phase SRM, mainly Hall effect sensors or photo interrupters have been used to detect the rotor position. But these sensors cause high cost and increase the volume of the motor, Furthermore when the motor is used in very hostile environment like high temperature or pressure, its reliability goes down. In this paper, low cost and robust characteristics of rotor position detection method are focused in order to compensate for disadvantage of existing sensors. Search coils wound around the stator pole are used for detection of the rotor position in single phase SRM. Rotor position detection is achieved through electromotive force patterns induced by time-varying flux linkage in the search coil. The validity of the method is verified by experimental results.

  • PDF

Extended Boost Single-phase qZ-Source Inverter for Photovoltaic Systems

  • Shin, Hyun-Hak;Cha, Honnyong;Kim, Hongjoon;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.918-925
    • /
    • 2014
  • This study presents an extended boost single-phase qZ-source DC-AC inverter for a single-phase photovoltaic system. Unlike the previously proposed single-phase qZ-source and semi-qZ-source inverters that achieve the same output voltage as that of the traditional voltage-fed full-bridge inverter, the proposed inverter can obtain higher output than input voltage. The proposed inverter also shares a common ground between DC input voltage and AC output voltage. Thus, possible ground leakage current problem in non-isolated grid-tied inverters can be eliminated with the proposed inverter. A 120 W prototype inverter is built and tested to verify the performance of the proposed inverter.

Design and Drive Performance of Single-phase Hybrid SRM with Commercial Ferrite Permanent Magnets (상용자석을 사용한 단상 하이브리드 SRM의 설계 및 구동 특성)

  • Ahn, Jin-Woo;Heo, Jae-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.184-189
    • /
    • 2013
  • Compared to a multiphase SRM, a single-phase SRM has some advantages, such as lower number of switches and power converter size, which leads to gradually increasing in the household appliances and industrial applications. But the torque dead zone is existed in the single-phase SRM which decreases the starting capability of the motor and increases the torque ripple. In order to solve the aforementioned problems, a single-phase hybrid SRM with commercial ferrite permanent magnet is proposed in this paper. Basic design principle for the proposed structure is described. To verify the proposed structure, FEM is employed to get the characteristics of the proposed structure. Based on the analysis, a prototype is designed and manufactured. And, the experimental system is also constructed. The validity of the proposed structure is verified by the experimental results.

Experimental measurements of R-22 two-phase friction factor in plate heat exchangers (판형열교환기에서 R-22 냉매의 이상 압력 손실계수 평가)

  • Yoo, Sang-Roon;Jeong, Ji-Rwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2273-2278
    • /
    • 2007
  • Brazed Plate Heat Exchanger (BPHE) is a type of compact plate heat exchanger with parallel corrugated plates which are brazed together in series. Each plate hascorrugation called herringbone pattern. Inside a BPHE, hot fluid and cold fluid alternate its flow direction to establish counter current flow configuration. Two-phase flow heat transfer and pressure drop of R-22 in BPHE were experimentally measured in this study. In the present experiments, single-phase region and two-phase region coexist in a BPHE. Therefore, the inside of a BPHE have to be divided into single phase region and two phase region and analyzed accordingly. The results from the single phase flow analysis are then extended to the two phase flow analysis to correlate the condensation and evaporation heat transfer and pressure drop for the refrigerant R-22 in the BPHEs. Previous models for two- phase friction factor have been compared with the present experimental results.

  • PDF

A Study on the Sterling Characteristics for Capacitor-run Single Phase Permanent Magent Synchronous Motor (커패시터 운전 단상 영구자석형 동기전동기 기동특성에 관한 연구)

  • 홍선기
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2004
  • Although permanent magnet single phase synchronous motor which starts and runs through single phase voltage source has high efficiency, it is difficult to determine the rotating direction. In this paper, the starting characteristics of the capacitor-run single phase synchronous motor has been studied. The stator has same structure with the capacitor-run single phase induction motor, however the rotor consists of permanent magnet. In this case, the starting conditions according to the rotor and stator conditions are determined and the direction of the motor can be determined. From these results, it is desired that the proposed motor can be applied to the loads like the fans which has low starting torque.

The Low Current Starting Simulation of a Single Phase Induction Motor Using Sliding Mode Control (슬라이딩 모드 제어를 이용한 단상 유도전동기의 저 전류 기동 시뮬레이션)

  • Kim, Hyo-Ki;Lee, Byung-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.44-53
    • /
    • 2007
  • In this paper, the Sliding Mode Controller is applied to reduce the starting current of the single phase induction motor. The input voltage to the single phase induction motor is controlled so that the starting current of the motor may be maintained within the rating value and the velocity is also controlled, by adjusting the switching function of the Sliding Mode Controller. The switching of sliding control made appropriately with regard to velocity error signal and acceleration signal. It is shown that the starting characteristics of the single phase induction motor(SPIM) can be greatly enhanced through the sliding control of single phase induction motor.

Design of DC Battery Size & Controller for Household Single-Phase ESS-PCS Considering Voltage Drop and DC Link Voltage Ripple (주택용 단상 ESS-PCS의 전압손실과 직류링크 맥동을 고려한 직류측 배터리 사이즈 및 제어기 설계)

  • Kim, Yong-Jung;Lee, Jinsung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.94-100
    • /
    • 2018
  • Generally, in a single-phase energy storage system (ESS) for households, AC ripple component with twice the fundamental frequency exists inevitably in the DC link voltage of single-phase PCS. In the grid-connected mode of a single-phase inverter, the AC ripple component in the DC link voltage causes low-order harmonics on grid-side current that deteriorates power quality on an AC grid. In this work, a control system adopting a feedforward controller is established to eliminate the AC ripple interference on the DC link side. Optimal battery nominal voltage design method is also proposed by considering the voltage loss and AC ripple voltage on DC link side in a single-phase ESS. Finally, the control system and battery nominal voltage design method are verified through simulations and experiments.

Operation Characteristic of Single-phase PFC converter with 1-switch Voltage Doubler Strategy (단일 스위치 배전압 방식의 단상 PFC 컨버터의 동작 특성)

  • Ku, Dae-Kwan;Ji, Jun-Keun;Cha, Guee-Soo;Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.561-568
    • /
    • 2011
  • This paper describes the operation characteristic of a single-phase PFC converter with 1-switch voltage doubler strategy for single-phase double-conversion UPS. A single-phase PFC converter with 1-switch voltage doubler strategy needs a diode bridge and one bidirectional active switch. Thus it is possible to reduce the material cost. However, the study results of operation characteristic and controller design has not been known after the converter circuit was proposed. For the performance evaluation of PFC converter, single-phase 3kVA double-conversion UPS was tested. The performance of PFC converter is experimentally confirmed with followings - input current reference traking, input power factor correction.