• Title/Summary/Keyword: Single prosthesis

Search Result 132, Processing Time 0.026 seconds

Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

  • Bacchi, Atais;Regalin, Alexandre;Bhering, Claudia Lopes Brilhante;Alessandretti, Rodrigo;Spazzin, Aloisio Oro
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.375-379
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at $10^6$ cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS. The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION. The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

SURVIVAL RATE OF THE DENTAL IMPLANTS PLACED IN POSTERIOR MAXILLA WITHOUT SINUS AUGMENTATION (상악동 골이식술 없이 상악 구치부에 식립된 임프란트의 생존율)

  • Park, Hye-Won;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.3
    • /
    • pp.170-175
    • /
    • 2009
  • Purpose : The purpose of this study is to evaluate 7-year survival rate of implants placed without bone graft in posterior maxilla and compare the survival rate by the age and gender of patient, length and diameter of implant, region of implant placement, bicortical engagement of fixture, and connection of prosthesis. Material and methods : 78 patients (170 implants) who visited our institution from 2002 to 2007 and were followed up with panoramic view and medical records. Kaplan-Meier survival analysis and Log Rank (Mantel-Cox) test were used. Results and conclusions : A 7-year cumulative survival rate for implants placed in posterior maxilla without sinus graft was 95.3%. The survival rate in men was 91.8%, significantly lower than 98.8% in woman.(p<0.05). However, the survival rate by the length of the implants did not show any significant differences.(p>0.05), while the wide platform implant resulted in 85% survival rate which was statistically lower than 98.5% in regular platform. The posterior maxillary implants engaged bicortically showed 97.6% of 7-year Survival rate, comparing 88.6% in not engaged implants. The survival rate of the single implant was 91.2%, while 98.5% in splinted prosthesis. Therefore, the bicortical engagement of the fixtures and splinted prosthesis may be recommended to get a long-term survival rate in posterior maxilla.

The analysis of cost-effectiveness of implant and conventional fixed dental prosthesis

  • Chun, June Sang;Har, Alix;Lim, Hyun-Pil;Lim, Hoi-Jeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.53-61
    • /
    • 2016
  • PURPOSE. This study conducted an analysis of cost-effectiveness of the implant and conventional fixed dental prosthesis (CFDP) from a single treatment perspective. MATERIALS AND METHODS. The Markov model for cost-effectiveness analysis of the implant and CFDP was carried out over maximum 50 years. The probabilistic sensitivity analysis was performed by the 10,000 Monte-Carlo simulations, and cost-effectiveness acceptability curves (CEAC) were also presented. The results from meta-analysis studies were used to determine the survival rates and complication rates of the implant and CFDP. Data regarding the cost of each treatment method were collected from University Dental Hospital and Statistics Korea for 2013. Using the results of the patient satisfaction survey study, quality-adjusted prosthesis year (QAPY) of the implant and CFDP strategy was evaluated with annual discount rate. RESULTS. When only the direct cost was considered, implants were more cost-effective when the willingness to pay (WTP) was more than 10,000 won at $10^{th}$ year after the treatment, and more cost-effective regardless of the WTP from $20^{th}$ year after the prosthodontic treatment. When the indirect cost was added to the direct cost, implants were more cost-effective only when the WTP was more than 75,000 won at the $10^{th}$ year after the prosthodontic treatment, more than 35,000 won at the $20^{th}$ year after prosthodontic treatment. CONCLUSION. The CFDP was more cost-effective unless the WTP was more than 75,000 won at the $10^{th}$ year after prosthodontic treatment. But the cost-effectivenss tendency changed from CFDP to implant as time passed.

Systemic-Pulmonary Shunts Using Microporous Polytetrafluoroethylene Prosthesis [Early and Late Results] (Polytetrafluoroethylene 인조혈관을 이용한 체-폐동맥 단락술의 조기성적 및 원격 성적)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.50-57
    • /
    • 1986
  • Sixty-nine patients with various types of cyanotic congenital heart disease underwent systemic-pulmonary artery shunts with a microporous polytetrafluoroethylene [PTFE] prosthesis between 1979 and 1985. Their ages ranged from 2 months to 39 years [mean$\pm$SD: 5.2$\pm$7.4, median: 3.3 years]. Diagnosis included the following: Tetralogy of Fallot, 45: Double outlet right or left ventricle, 11: Single ventricle, .5: Transposition of great vessels, 4: Tricuspid atresia, 3 and Pulmonary atresia with intact ventricular septum, 1. Forty-eight patients had subclavian-pulmonary artery anastomosis, 12 patients aorta-right pulmonary artery anastomosis, 6 patients aorta-main pulmonary artery anastomosis, and 3 patients descending aorta-pulmonary artery anastomosis. The PTEE graft of 3 mm in diameter was used in 1, 4 mm in 29, 5 mm in 35 and 6 mm in 4 patients. Ten patients were died within 30 days after operation [mortality rate: 14.5%]. Among them, 6 patients were operated in urgency due to cardiac arrest or severe anoxic spell after cardiac catheterization, and so surgical mortality of elective operation is 9.5%. The 59 survivors showed improvement of the arterial oxygen saturation [65.4% - 9.8%] and hemoglobin [18.8 gm/dl - 16.0 gm/dl] values [V<0.01]. The follow up period ranged from 1 month to 67 months, [752 patient-months] and during this periods there were 4 late shunt failures after 3 months postoperatively with 4 mm graft, and 2 with 5 mm graft. The over-all patency rate of 4 mm PTFE was 85.9$\pm$9.2% [SEM] in 12 months and 40.9$\pm$22.5% in 24 months. The over-all patency rate of 5 mm PTFE was 87.5$\pm$9.6% in 12 months and 58.3$\pm$24.6% in 36 months. The lowest systolic pressure in death group was 64.9$\pm$15.0 mmHg and in survival group, 86.4$\pm$12.1 mmHg [P<0.001]. We think that the PTFE graft is useful in palliative shunt operation, but the effectiveness of the 4 mm PTFE graft may be limited. The blood pressure also may play an important role in patency of Prosthesis.

  • PDF

Effects of a Personalized Nurse-Led Educational Program for New Patients Receiving Oral Anticoagulant Therapy after Mechanical Heart Valve Prosthesis Implantation on Adherence to Treatment

  • Eltheni, Rokeia;Schizas, Nikolaos;Michopanou, Nektaria;Fildissis, Georgios
    • Journal of Chest Surgery
    • /
    • v.54 no.1
    • /
    • pp.25-30
    • /
    • 2021
  • Background: Life-long anticoagulant therapy is mandatory for patients who undergo heart valve replacement with implantation of a mechanical prosthesis. The aim of this study was to investigate the effects of a nurse-led patient educational program concerning oral anticoagulant therapy intake after heart valve replacement surgery on patients' knowledge of important parameters of anticoagulant administration. Methods: In this single-center study, 200 patients who underwent surgical implantation of a mechanical prosthesis were divided into 2 groups. The control group received the basic education concerning oral anticoagulants, while the intervention group received a personalized educational program. Results: Personalized education was correlated with a better regulation of therapeutic international normalized ratio (INR) levels and adequate knowledge among patients. Therapeutic levels of INR were achieved in 45% of the patients during the first month, 71% in the third month, and 89% in the sixth month after discharge in the intervention group, compared to 25%, 47%, and 76% in the control group, respectively. Patients' satisfaction with the information was higher in the intervention group than in the control group. The percentage of satisfaction reached 80% for the intervention group versus 37% for the patients of the control group. Conclusion: The implementation of the nurse-led educational programs was associated with improved clinical results and increased adherence to oral anticoagulant treatment.

Biomechanical characteristics of the distal filling effects in cementless femoral stem (무시멘트형 대퇴스템에서 원위부 압박 정도에 따른 생체역학적 특성)

  • Park, Sang-eok;Park, Jae-Won;Chae, Soo-Won
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.387-392
    • /
    • 2000
  • In cementless total hip replacement(THR), an initial stability of the femoral component is important to long term fixation of femoral stem. The initial stability has close relationship with the relative displacement of prosthesis and spongy bone at the proximal of femur. After implantation of the prosthesis. the surrounding bone is partially shielded from load carrying and starts to resort. Stress shielding is the cause of the loss of proximal bone. Assessing stress distribution of femur is important to predict stress shielding. The initial stability and the stress shielding were investigated for two loading conditions approximating a single leg stance and a stair climbing. Three types of stems were studied by the finite element method to analyze the biomechanical effects of distal filling of cementless femoral stems, Three types of stems employed are a distal filling stem, a distal flexible stem, and a distal tapered stem.

  • PDF

Development of a Control Strategy for a Multifunctional Myoelectric Prosthesis

  • Kim Seung-Jae;Choi Hwasoon;Youm Youngil
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.243-249
    • /
    • 2005
  • The number of people who have lost limbs due to amputation has increased due to various accidents and diseases. Numerous attempts have been made to provide these people with prosthetic devices. These devices are often controlled using myoelectric signals. Although the success of fitting myoelectric signals (EMG) for single device control is apparent, extension of this control to more than one device has been difficult. The lack of success can be attributed to inadequate multifunctional control strategies. Therefore, the objective of this study was to develop multifunctional myoelectric control strategies that can generate a number of output control signals. We demonstrated the feasibility of a neural network classification control method that could generate 12 functions using three EMG channels. The results of evaluating this control strategy suggested that the neural network pattern classification method could be a potential control method to support reliability and convenience in operation. In order to make this artificial neural network control technique a successful control scheme for each amputee who may have different conditions, more investigation of a careful selection of the number of EMG channels, pre-determined contractile motions, and feature values that are estimated from the EMG signals is needed.

Time Serial Change of Proximal Contact Tightness after Crown Restoration (인공치관 수복 후 인접면 접촉강도의 경시적 변화)

  • Na, Hyun-Joon;Kang, Dong-Wan;Oh, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.197-204
    • /
    • 2010
  • The purpose of the study was to observe the time serial changes in proximal contact tightness after single crown restoration. Initial proximal contact tightness before crown preparation and after prosthesis restoration were measured repeatedly in 12 subjects. In consequence proximal contact tightness of temporary setting on prosthesis was bigger than contact tightness before initial preparation, contact tightness of the prostheses of 1-2 weeks after the setting was similar to that before the preparation, tightness of 2-4 weeks after the setting showed little change and maintained constant contact tightness.

Long-Term Clinical Results of the St. Jude Medical Valve in Mitral Position (St. Jude 승모판막의 장기 임상성적)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.27 no.8
    • /
    • pp.664-668
    • /
    • 1994
  • A total of 217 patients underwent single mitral valve replacement [MVR] with the St. Jude Medical valve between September 1984 and the end of 1992. There were 86 males and 131 females with a mean age of 34.6 $\pm$ 14.4 years[range 5 months-61 years]. A previous valve replacement had been performed in 46 patients [21.2 %]. An early mortality rate was 7.4 % [5.2 % in primary MVR; and 15.2 %in re-replacement MVR]. Early survivors of 201 patients were followed up for a total of 934.5 patient-years[mean 4.7 $\pm$ 2.1years]. A late mortality rate was 2.5 % or 0.54%/patient-year. The linearized rates of thromboembolism, valve thrombosis and anticoagulation-related bleeding were 1.301 %, 0.214 % and 0.428 %/patient-year, respectively. The actuarial survival including operative mortality was 89.9 % $\pm$ 2.1% at postoperative 10 years. The freedom from thromboemolism was 91.3 %$\pm$ 2.5% and the actuarial estimate of incidence free from late deaths and all complications were 80.9 % $\pm$ 3.8 % at 10 years. There were no mechanical failures. In summary, the St. Jude Medical prosthesis performed satisfactorily with an acceptable rate of late complications.

  • PDF

A within-subject comparison of short implants in the posterior region: retrospective study of up to 10 years

  • Segalla, Douglas Blum;Villarinho, Eduardo Aydos;Correia, Andre Ricardo Maia;Vigo, Alvaro;Shinkai, Rosemary Sadami Arai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.172-179
    • /
    • 2021
  • Purpose. This intra-patient retrospective study of up to 10 years evaluated the clinical success and risk factors of 6- and 8-mm long implants and their respective prostheses. Materials and Methods. The sample consisted of patients treated at a Military Polyclinic dental service, who received both 6- and 8-mm long tissue level implants in the posterior region of the same arch. Data were collected from the dental charts, clinical and radiographic exams, self-report of sleep bruxism, measurement of maximum occlusal force, and clinical crown-to-implant (C/I) ratio. Data were analyzed by descriptive and inferential statistics with univariate and hierarchical multivariate models, at the 0.05 significance level. Results. The 30 patients (27 women) had 85 implants and 83 prostheses. Two implants were lost before prosthesis installation (implant survival: 97.6%). Ten events of prosthetic complication (screw tightening loss) occurred in five patients (success rate: 87.9%) in a single moment. Only the variable C/I ratio had a significant effect for repairable prosthesis complication (P<.05). Conclusion. The results suggest that 6- and 8-mm long implants have similar long-term clinical success for implants and prostheses.