• Title/Summary/Keyword: Single photon emission computed tomography

Search Result 146, Processing Time 0.026 seconds

Post-Coronary Artery Bypass Grafting Myocardial Ischemia Caused by an Overgrown Left Internal Thoracic Artery Side Branch

  • Kim, Eung Re;Oh, Se Jin;Kang, Hyun-Jae;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.47 no.5
    • /
    • pp.465-467
    • /
    • 2014
  • We present a patient who developed recurrent angina after coronary artery bypass grafting (CABG). Myocardial single-photon emission computed tomography (SPECT) demonstrated deterioration in the myocardial perfusion, and coronary angiography revealed an overgrown side branch of the grafted left internal thoracic artery (ITA); otherwise, there were no significant changes compared with previous imaging studies obtained after the CABG. After percutaneous embolization of the grafted left ITA side branch, the angina was resolved and myocardial SPECT showed improved perfusion.

The Influence of Collimators on SPECT COR Measurements (SPECT 회전중심 측정에 있어서 콜리메타의 영향)

  • Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.19 no.1
    • /
    • pp.89-94
    • /
    • 1996
  • Misalignment between the electronic and mechanical axes of rotation will result in artifact generation and image degradation during single photon emission computed tomography(SPECT) reconstruction. Acceptance and quality control testing procedures have not emphasized the variability in center of rotation(COR) measurements caused by collimators and the need to verify uniformity across the full collimator field of view (FOV). Variation from the mean COR across the FOV was tested in four different collimators using multiple point source acquisitions. The mean COR was different for each collimator and one of the four had a > 0.5 pixel difference from the mean COR on some area of the FOV, This variation makes this collimator unacceptable for SPECT acquisition. Thus, initial acceptance testing of SPECT collimators should verify a uniform COR across the full FOV and collimators with a variability from the mean COR > 0.5 pixels should be rejected.

  • PDF

Redo-Coronary Artery Bypass due to Progression of the Celiac Axis Stenosis

  • Yeom, Sang-Yoon;Hwang, Ho-Young;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.45 no.4
    • /
    • pp.251-253
    • /
    • 2012
  • We report a redo coronary artery bypass grafting (CABG) in a 55-year-old man. Angina recurred 7 years after the initial surgery. Coronary angiography showed all patent grafts except a faint visualization of the in situ right gastroepiploic artery (RGEA) graft, which was anastomosed to the posterior descending coronary artery, associated with celiac axis stenosis. Redo-CABG was performed at postoperative 10 years because of aggravated angina and decreased perfusion of the inferior wall in the myocardial single photon emission computed tomography. The saphenous vein graft was interposed between the 2 in situ grafts used previously; the right internal thoracic artery and RGEA grafts. Angina was relieved and myocardial perfusion was improved.

Significant Reperfusion on $^{99m}Tc-HMPAO$ SPECT in a Case of Subacute MCA Infarction (한의학적 치료로 $^{99m}Tc-HMPAO$ SPECT상 현저한 재관류를 보인 아급성기 중대뇌동맥경색 환자 1례)

  • Park, Jung-Mi;Jung, Woo-Sang;Seo, Al-An
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.437-442
    • /
    • 2001
  • For ischemic cerebrovascular disease, it is well known that early luxury perfusion is related to a good clinical outcome and single photon emission computed tomography(SPECT) has the potential for providing useful information about regional cerebral blood flow. We report one case of Rt. MCA infarction mainly treated by oriental medicine and revealed luxury perfusion without thrombolysis. In acute stage, neurological deficits of the patient were very severe. 99mTc-HMPAO SPECT images obtained 10days after the attack showed large perfusion defect in the Rt. MCA territory. We followed up 99mTc-HMPAO SPECT 40days after the ictus. Despite of the poor early perfusion, we found considerably improved perfusion and neurological improvement.

  • PDF

Effect of Radioisotope Position on Performance of Industrial SPECT (방사성동위원소 위치에 따른 산업용 SPECT 성능에 미치는 영향)

  • Moon, Jinho;Kim, Jongbum;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.245-249
    • /
    • 2012
  • Demand of fluid flow visualization has increased in industrial processes, because medical imaging technology is highly developed. As a part of the industrial process imaging technology, industrial single photon emission computed tomography (SPECT) system was developed to measure the cross-sectional distribution of the process fluid. The SPECT consists of 36 NaI (Tl) detectors with the hexagonal configuration. Reconstructed images were acquired for various positions of radioactive source to estimate SPECT device performance. To evaluate the reliability of the experimental results, the Monte Carlo simulation results are compared with experimental results. In general, the experimental and simulation results were consistent. However, as the source position was getting far from the center of the reactor, the accuracy of reconstructed images was compromised. It seems to be due to the inconsistent spatial resolution of the collimators according to the source position.

Influence of Void on Performance of Industrial SPECT System (공정 내 기포가 산업용 SPECT의 성능에 미치는 영향)

  • Park, Jang Guen;Jung, Sung-Hee;Kim, Jong Bum;Moon, Jinho;Kim, Chan Hyeong
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.23-27
    • /
    • 2014
  • Industrial single photon emission computed tomography (SPECT) is an useful technique to investigate the dynamic behavior of process flow. In the present study, to evaluate the influence of a void on the performance of industrial SPECT, industrial SPECT with various radioisotope sources and gas holdups was modeled by the Monte Carlo simulation. The results are very encouraging; that is, the void little influences the performance of industrial SPECT, which means that industrial SPECT could be a suitable tool to investigate the dynamic characteristics of the flow in a water-air phase process.

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY FINDINGS IN ATTENTION DEFICIT- HYPERACTIVITY DISORDER (주의력결핍 ${\cdot}$ 과잉운동장애의 단일광자방출 전산화단층촬영 소견에 관한 연구)

  • Cho, Soo-Churl;Lee, Myung-Chul;Moon, Dae-Hyuk
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.1 no.1
    • /
    • pp.27-39
    • /
    • 1990
  • The neural mechanisms involved in attention deficit hyperactivity disorder are largely unknown. In order to investigate the neuroanatomical lesions of attention deficit hyperactivity disorders and their relationships with psychopathology, Single Photon Emission Computed Tomography(SPECT) using HMPAO was performed in 46 ADHDS and Yale Children's Inventory(YCI), Conners Parent Questionaire and DSM-III-R Questionaire for Disruptive Behavior Disorder were used to assess the psychopathology of ADHDS The results are summarized as follows; 1) 30.4% (14/46) of this series revealed decreased perfusion In SPECT. 2) Regions of hypoperfusion were seen in cerebral cortex(17.4%, 8/46), thalamus(13.0%, 6/46), deep gray matter(8.7%, 4/46), basal ganglia(6.5%, 3/46) and cerebellum(2.2%, 1/ 46). 3) The mean scores of the total YCI revealed significant difference between the two groups(SPECT abnormal versus normal group), and among the subscales, hyperactivity, language and fine-motor subscales showed significant differences between the two groups. Although the relationship between the abnormal findings and specific symptom clusters of ADHDS remains unclear, we can suggest that these abnormal findings could be associated with ADHD, and based on these findings, the ADHDS can be subclassified into two groups. This study can be said to reinforce the current conception of heterogeneity of ADHD.

  • PDF

SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY FINDINGS IN TOURETTE'S AND CHRONIC MOTOR TIC DISORDER (뚜렛씨병과 만성틱장애의 단일광자방출전산화단층촬영 소견에 관한 연구)

  • Cho, Soo-Churl;Lee, Myung-Chul;Kim, Ja-Sung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.4 no.1
    • /
    • pp.68-78
    • /
    • 1993
  • The pathophysiology and neural mechanism involved in Tourette's and chronic motor tic disorder are highly controversial. In order to investigate the functional abnormalities of brain. In Tourette's and chronic motor tic disorder, 42 children with Tourette's and chronic motor disorder underwent single photon emission computed tomography(SPECT) using Tc-99m-HM-PAO. The results are summarized as follows : 1) 31.0% (13/42) of this series revealed perfusion defect in cerebral cortex. 2) 4.8% (2/42) revealed perfusion defect in basal ganglia. 3) 4.8(2/42) revealed perfusion defect in thalamus. 4) 16.7%(7/42) showed perfusion defect in cerebellum. 5) The frequency of abnormal perfusion showed no significant difference between tic with and without attention deficit hyperactivity disorder. 6) The frequency of abnormal perfusion showed no significant difference between Tourette's and chronic motor tic disorder. These findings support the hypothesis of a possible involvement of brain dysfunction in the production of Tourette's and chronic motor tic disorder, and quantification of blood flow and co-registration with magnetic resonance imaging will increase the validity of this study.

  • PDF