• Title/Summary/Keyword: Single panel

Search Result 437, Processing Time 0.03 seconds

The Relations between Parenting Behaviors and Adolescents' Externalizing Problems in Single Parent Families : The Mediating Roles of Self-Control and Self-Esteem (한부모 가정 청소년의 부모 양육태도와 외현화 문제 간 관계 : 자아통제와 자아존중감의 매개효과)

  • Lee, Ju-Lie
    • Journal of Families and Better Life
    • /
    • v.28 no.2
    • /
    • pp.123-130
    • /
    • 2010
  • This longitudinal study investigated the mediating effects of self-control and self-esteem on the associations between parenting behaviors and middle school students' externalizing problems in single parent families. Participants were 174(2003-2004 panel 1 data of Korea Youth Panel Survey). The results of structural equation modeling indicated that self-control and self esteem did not mediate the associations between time 1 parenting behaviors and time 2 middle school students' externalizing problems, after accounting for the effects of time 1 middle school students' externalizing problems.

Plasma discharge characteristics of MgO protection layer deposited by using targets made of single crystals, and nano powders

  • Yang, Choong-Jin;Park, Eun-Byeong;Lee, Ho-Sang;Park, Jung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.157-160
    • /
    • 2008
  • Improved properties of second electron emission was evaluated by assemble of 4 inch PDP panel. MgO protection layers were deposited and examined by using both pellets made of extremely pure MgO single crystals and sintered pellets using MgO nano powders. $\gamma$ coefficients higher than 0.11 were obtained from the panel by adopting dopant-controlled MgO single crystals. Especially the MgO layer deposited by sintered pellets made of nano powders showed the higher $\gamma$ coefficients at the operating voltage above 200 volts.

  • PDF

Analysis of fatigue Crack Growth Behavior in the Integrally Stiffened Panels Subjected to Single Overload (과하중을 받는 일체형 보강판의 피로균열 성장거동 해석)

  • 이환우;서정호
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.28-34
    • /
    • 2004
  • It is well known that tensile peak overloads may significantly delay suubsequent constant amplitude fatigue crack growth in many materials. Since real structures are usually subjected to complex load histories, the ability to predict accurate crack growth under realistic service conditions is of major engineering interest. This paper describes experiments on fatigue track growth in the integrally stiffened panel of 7075-T6 aluminum alloy. The effect of shape parameters and overload position on the fatigue crack growth behavior of integrally stiffened panels are discussed. Based on the experimental results, the following conclusions have been drawn: the overall fatigue crack growth retardation resulting from single overload in the stiffened panels was generally larger in the larger thickness ratio, although the retardation trends, according to the change in overload positions, were similar to those exhibited in the non-stiffened panels.

Viewing angle switching of a liquid crystal panel by using 3-terminal electrode structure

  • Kwon, Yong-Hoan;Baek, Jong-In;Kim, Jae-Chang;Yoon, Tae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.399-402
    • /
    • 2007
  • We propose a method to achieve both wide viewing angle (WVA) and narrow viewing angle (NVA) characteristics with a single liquid crystal (LC) panel and a single backlight system by using 3-terminal electrode structure. We could control the viewing angle of a single LC cell by using the horizontal or vertical alignment of LC for the dark state at the front.

  • PDF

Transmitted Noise Reduction Performance of Piezoelectric Single Panel through Piezo-damping (압전감쇠를 통한 압전단일패널의 전달 소음저감성능)

  • 이중근;김재환;김기선;이형식
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.49-56
    • /
    • 2001
  • The possibility of a noise reduction of piezoelectric single Panels is experimentally studied. Piezoelectric single panel is basically a plate structure on which piezoelectric patch with shunt circuit is mounted. The use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. Piezo-damping is implemented by using a newly proposed tuning method. This method is based on electrical impedance model and maximizing the dissipated energy at the shunt circuit. By measuring the electrical impedance at the piezoelectric patch bonded on a structure, an equivalent electrical model is constructed near the system resonance frequency. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of single Panel is tested on an acoustic tunnel. The tunnel is a tube with a square cross section and a loud speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across Panels is measured. By enabling the piezoelectric shunt damping noise reduction is achieved at the resonance frequencies as well. Piezoelectric single panel with piezoelectric shunt damping is a promising technology for noise reduction in a broadband frequency.

  • PDF

Analysis of Pumping Characteristics for Cryopump with Multipanel Cryoarray (다층 Panel Cryoarray를 갖는 Cryopump의 Pumping 특성해석)

  • 이진원;이영규;최헌오
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.3
    • /
    • pp.323-331
    • /
    • 1992
  • 다층 panel형 cryoarray를 갖는 원통형 cryopump의 정적 pumping 특성을 view factor를 이용한 수치적 방법으로 해석하였다. 해석모델은 단순 원판을 기본으로 하고, 여기 에 상향 및 하향의 skirt를 부착한 실질적 array를 대상으로 하였으며, 형상, 크기 및 panel 개수를 변화시키면서 array 전체의 총 pumping 효율과 array 내의 pumping 속도 분포를 모두 구하였다. 다층 panel array에서도 single panel의 경우와 같이 type III 개스(He, H2) 에 있어서는 pumping 효율을 최대로 하는 최적의 크기가 있으며, panel 수효가 증가하면 pumping 속도는 약간만 증가하나 총 pumping 용량은 이에 비례하여 증가한다. Skirt의 각 도를 상향으로 변화시키면 type III 개스의 상대적 pumping 속도가 증가되며 type II 개스에 의한 cryosorbent의 오염도는 대략 10% 정도이다.

  • PDF

A study on the arrangement of actuators and speaker zones of the panel speaker (패널 스피커의 가진기 및 스피커 배치에 관한 연구)

  • Jung-Han Woo;Seong-Hyun Lee;Yun-Ho Seo;Pyung-Sik Ma;Dongjoon Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.388-394
    • /
    • 2023
  • When the vibration of the thin panel by exciting single point is used to radiate sound, the inherent vibration characteristic of the plate itself causes influence on the radiated sound. A conventional panel speaker system usually uses the single or double point excitations for generating the sound through the panel itself. The radiated sound can be easily distorted due to the modal characteristics of the plate so it is difficult to expect sufficient sound power or high radiation efficiency. In this paper, to achieve an immersive sound field, the multiple speaker zones on a thin panel are created with the limited number of actuators. The designated vibration field which can generates directional sound is realized by employing the vibro-acoustic inverse rendering methods. Actuators are arranged from the positions which have the advantage of implementing with multi-modal excitations. The location and number of actuators are compared with the location and number of controllable speaker zones by conducting numerical simulations.

Performance Analysis of Heat Pump System with Air Source Evaporator and Single Unit Dual Sink Condenser (공기열원 2중히트싱크 열펌프의 성능해석)

  • Woo, J.S.;Lee, S.K.;Lee, J.H.;Park, H.S.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.11-22
    • /
    • 1998
  • Floor panel heating system using hot water is the primary heating system of domestic residential building. This paper presents the results of performance analysis of the heat pump system with air source evaporator and single unit dual sink(SUDSk) condenser. The heat exchanger combines two separated condensers into a single condenser and the object of the SUDSk condenser is to release energy to dual sinks, i.e. air for air heating system and water for panel heating system in one single unit. Simulation program is developed for single unit dual source(SUDS) SUDSk heat pump system and some experimental data are obtained and compared with simulation results. Differences of heating capacity and COP in dual source operating mode are 7% and 8% respectively. Simulation results are in good agreement with test results. Therefore, developed program is effectively used for design and performance prediction of dual source dual sink heat pump system with SUDS evaporator and SUDSk condenser.

  • PDF

Spot Weld Fatigue Life Prediction of Auto Set Belt Anchors Using $K_e$ (K_e에 의한 차량 안전벨트 앵커의 점용접 피로수명 예측)

  • Kim, Nam-Ho;Lee, Hyeong-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.3 s.174
    • /
    • pp.701-709
    • /
    • 2000
  • As the welding spot forms a singular geometry of an external crack type, fatigue failure of spot-welded specimens can be evaluated by means of a fracture parameter. Recasting the load vs. fatigue life relationships experimentally obtained, we predicted the fatigue life of spot-weld specimens with a single parameter denoted the equivalent stress intensity factor. This crack driving parameter is demonstrated to successfully describe the effects of specimen geometry and loading type in a comprehensive manner. The suggested fatigue life formula for a single spot weld can play a key role in the design and assessment of spot-welded panel structures, in that the fatigue strength of multi-spots is eventually determined by the fatigue strength of each single spot. We therefore attempt to evaluate the effectiveness and validity of $K_e$ in predicting the fatigue life of auto seat belt anchor panel. We first establish finite element models reflecting the actual mechanical behavior of 3 types of seat belt anchor specimens. Using finite element models elaborately established, we then obtain the effective crack driving parameter $K_e$ composed of its ductility -dependent modal components. It is confirmed that the $K_e$ concept successfully predicts the fatigue life of multi-spot welded panel structures represented by auto seat belt anchors here.

Electrostatic Suspension System of Glass Panels using Relay Feedback Control (릴레이 제어법을 이용한 유리패널의 정전부상에 관한 연구)

  • Jeon, Jong-Up
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.6
    • /
    • pp.71-79
    • /
    • 2008
  • In the manufacture of flat panel display devices, there is a strong demand for contactless glass panel handling devices that can manipulate a glass panel without contaminating or damaging it. To fulfill this requirement, an electrostatic suspension device far glass panels where the glass panel is supported by electrostatic forces without any mechanical contact is proposed. To implement the system with low cost and compactness, switched-voltage control scheme that is based on the relay feedback control is utilized. Relay feedback control method deploys only a single high-voltage power supply that can deliver a DC voltage of positive and/or negative polarity and thus high voltage amplifiers that are costly and bulky are not needed any more. It is shown that despite the inherent limit cycle property of the relay feedback based control, an excellent performance in vibration suppression is attained due to the presence of a relatively large squeeze film damping originating from the electrodes and levitated object. Using this scheme, a $100{\times}100mm^2$ glass panel was levitated stably with airgap variation decreasing down to $1\;{\mu}m$ at an airgap of $100\;{\mu}m$.