• Title/Summary/Keyword: Single length technique

Search Result 226, Processing Time 0.029 seconds

Influence of the Adhesive, the Adherend and the Overlap on the Single Lap Shear Strength

  • da Silva, Lucas F.M.;Ramos, J.E.;Figueiredo, M.V.;Strohaecker, T.R.
    • Journal of Adhesion and Interface
    • /
    • v.7 no.4
    • /
    • pp.1-9
    • /
    • 2006
  • The single lap joint is the most studied joint in the literature in terms of both theory and practice. It is easy to manufacture and the lap shear strength is a useful value for strength assessment and quality control. Simple design rules exist such as the one present in standard ASTM 1002 or in a recent paper by Adams and Davies. The main factors that have an influence on the lap shear strength are the type of adhesive, i.e. ductile or brittle, the adherend yield strength and the overlap length. The overlap increases the shear strength almost linearly if the adhesive is sufficiently ductile and the adherend does not yield. For substrates that yield, a plateau is reached for a certain value of overlap corresponding to the yielding of the adherend. For intermediate or brittle adhesives, the analysis is more complex and needs further investigation. In order to quantify the influence of the adhesive, the adherend and the overlap on the lap shear strength, the experimental design technique of Taguchi was used. An experimental matrix of 27 tests was designed and each test was repeated three times. The influence of each variable could be assessed as well as the interactions between them using the statistical software Statview. The results show that the most important variable on the lap shear strength is the overlap length followed by the type of adherend.

  • PDF

Transtibial Double Bundle PCL Reconstruction using TransFix Tibial Fixation - Technical Note - (TransFix 경골부 고정을 이용한 경 경골 두 다발 후방십자인대 재건술 - 수술 술기 -)

  • Lee, Yong-Seuk;Jung, Young-Bok;Ahn, Jin-Hwan;Kang, Bun-Jung;Shin, Yun-Chang;Kong, Chae-Gwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.203-208
    • /
    • 2006
  • Purpose: Previous transtibial double bundle posterior cruciate ligament (PCL) reconstruction methods have several problems in graft length and tibial fixation. We introduce new surgical method that is less restrictive by graft length and is more stable with single tibial fixation. Operative technique: After diagnostic arthroscopy, we prepare the graft, ream the tibial tunnel and perform the procedure for TransFix tibial fixation. Femoral 2 tunnel is made and graft is passed via anteromedial (AM) portal. Tibial fixation is done and femoral 2 graft is fixed sequentially at each knee position. Conclusion: TtransFix tibial single fixation method in double bundle PCL reconstruction provides more stable fixation, more free graft selection and prevents graft damage by passing the graft via AM portal.

  • PDF

THE IMPROVEMENT OF THE RELATIVE POSITIONING PRECISION FOR GPS L1 SINGLE FREQUENCY RECEIVER USING THE WEIGHTED SMOOTHING TECHNIQUES (가중 평활화 기법을 이용한 GPS L1 단일 주파수 수신기의 상대 측위 정밀도 향상)

  • Choi, Byung-Kyu;Park, Jong-Uk;Joh, Jeong-Ho;Lim, Hyung-Chul;Park, Phi-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.371-382
    • /
    • 2004
  • To improve the precision of relative positioning for GPS single frequency(L1) receiver, we accomplished the GPS data processing using the weighted smoothing techniques. The weighted phase smoothing technique is used to minimize the measurement error of pseudorange and position domain smoothing technique is adopted to make the complement of cycle-slip affection. we also considered some component errors like as ionospheric error, which are related with baseline length, and processed for several baselines (5, 10, 30, 40, and 150 km) to check the coverage area of this algorithm. This paper shows that weighted phase smoothing technique give more stable results after using this technique and the position domain smoothing technique can reduce the errors which are sensitive to the observational environment. Based on the results, we could find out that this algorithm is available for post-time and real-time applications and these techniques can be substitution methods which is able to get the high accuracy and precision without resolving the Integer ambiguity.

Characterization of Electrical Properties and Gating Effect of Single Wall Carbon Nanotube Field Effect Transistor

  • Heo, Jin-Hee;Kim, Kyo-Hyeok;Chung, Il-Sub
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.169-172
    • /
    • 2008
  • We attempted to fabricate carbon nanotube field effect transistor (CNT-FET) using single walled carbon nanotube(SWNT) on the heavily doped Si substrate used as a bottom gate, source and drain electrode were fabricated bye-beam lithography on the 500 nm thick $SiO_2$ gate dielectric layer. We investigated electrical and physical properties of this CNT-FET using Scanning Probe Microscope(SPM) and conventional method based on tungsten probe tip technique. The gate length of CNT-FET was 600 nm and the diameter of identified SWNT was about 4 nm. We could observed gating effect and typical p-MOS property from the obtained $V_G-I_{DS}$ curve. The threshold voltage of CNT-FET is about -4.6V and transconductance is 47 nS. In the physical aspect, we could identified SWNT with phase mode of SPM which detecting phase shift by force gradient between cantilever tip and sample surface.

Single Longitudinal Mode Operation of a Pulsed Dye Laser Injection-seeded with a CW Ring Dye Laser (인젝션 록킹 방법에 의한 펄스 색소레이저의 단일 종모우드 발진)

  • 김재완;공홍진;한재원;박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.84-89
    • /
    • 1994
  • A tunable pulsed dye laser was operated in a single longitudinal mode by injection locking with a cw ring dye laser. A doubled Nd:YAG laser was used as the pumping source. Phase sensitive detection technique was applied to maintain the required match between the master laser frequency and the slave resonator cavity length. The fluctuation of the center frequency of the pulsed laser was < 10 MHz, and the pulse duration (FWHM) was 6 ns. The linewidth measured by scanning confocal interferometer was 130 MHz. When pumped by 50 mJ of the doubled Nd:YAG laser, the output energy of the pulsed dye laser was 2 mJ and the peak power was 330 kW. 30 kW.

  • PDF

A modular function decomposition of multiple-valued logic functions using code assignment (코드할당에 의한 다치논리함수의 모듈러 함수분해에 관한 연구)

  • 최재석;박춘명;성형경;박승용;김형수
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.7
    • /
    • pp.78-91
    • /
    • 1998
  • This paper presents modular design techniques of multiple-valued logic functions about the function decomposition method and input variable management method. The function decomposition method takes avantage of the property of the column multiplicity in a single-column variable partitioning. Due to the increased number of identical modules, we can achieve a simpler circuit design by using a single T-gate, which can eliminate some of the control functions in the module libraty types. The input variable management method is to reduce the complexity of the input variables by proposing the look up table which assign input variables to a code. In this case as the number of sub-functions increase the code-length and the size of the code-assignment table grow. We identify some situations where shard input variables among sub-functions can be further reduced by a simplicication technique. According to the result of adapting this method to a function, we have demonstrated the superiority of the proposed methods which is bing decreased to about 12% of interconnection and about 16% of T-gate numbers compare with th eexisting for th enon-symmetric and irregular function realization.

  • PDF

An Overview of Different Techniques on the Microbial Community Structure, and Functional Diversity of Plant Growth Promoting Bacteria

  • Kim, Kiyoon;Islam, Rashedul;Benson, Abitha;Joe, Manoharan Melvin;Denver, Walitang;Chanratan, Mak;Chatterjee, Poulami;Kang, Yeongyeong;Sa, Tongmin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.2
    • /
    • pp.144-156
    • /
    • 2016
  • Soil is a dynamic biological system, in which it is difficult to determine the composition of microbial communities. Knowledge of microbial diversity and function in soils are limited because of the taxonomic and methodological limitations associated with studying the organisms. In this review, approaches to measure microbial diversity in soil were discussed. Research on soil microbes can be categorized as structural diversity, functional diversity and genetic diversity studies, and these include cultivation based and cultivation independent methods. Cultivation independent technique to evaluate soil structural diversity include different techniques such as Phospholipid Fatty Acids (PLFA) and Fatty Acid Methyl Ester (FAME) analysis. Carbon source utilization pattern of soil microorganisms by Community Level Physiological Profiling (CLPP), catabolic responses by Substrate Induced Respiration technique (SIR) and soil microbial enzyme activities are discussed. Genetic diversity of soil microorganisms using molecular techniques such as 16S rDNA analysis Denaturing Gradient Gel Electrophoresis (DGGE) / Temperature Gradient Gel Electrophoresis (TGGE), Terminal Restriction Fragment Length Polymorphism (T-RFLP), Single Strand Conformation Polymorphism (SSCP), Restriction Fragment Length Polymorphism (RFLP) / Amplified Ribosomal DNA Restriction Analysis (ARDRA) and Ribosomal Intergenic Spacer Analysis (RISA) are also discussed. The chapter ends with a final conclusion on the advantages and disadvantages of different techniques and advances in molecular techniques to study the soil microbial diversity.

A Study on Logic Built-In Self-Test Using Modified Pseudo-random Patterns (수정된 의사 무작위 패턴을 이용한 효율적인 로직 내장 자체 테스트에 관한 연구)

  • Lee Jeong-Min;Chang Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.8 s.350
    • /
    • pp.27-34
    • /
    • 2006
  • During Built-In Self-Test(BIST), The set of patterns generated by a pseudo-random pattern generator may not provide sufficiently high fault coverage and many patterns were undetected fault. In order to reduce the test time, we can remove useless patterns or change from them to useful patterns. In this paper, we reseed modify the pseudo-random and use an additional bit flag to improve test length and achieve high fault coverage. the fat that a random tset set contains useless patterns, so we present a technique, including both reseeding and bit modifying to remove useless patterns or change from them to useful patterns, and when the patterns change, we choose number of different less bit, leading to very short test length. the technique we present is applicable for single-stuck-at faults. the seeds we use are deterministic so 100% faults coverage can be achieve.

Effect of Relative Position of Vane and Blade on Heat/Mass Transfer Characteristics on Stationary Turbine Blade Surface (베인과 블레이드 사이의 상대위치 변화에 따른 터빈 블레이드 표면에서의 열/물질전달 특성)

  • Rhee, Dong-Ho;Cho, Hyung Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.4 s.31
    • /
    • pp.27-38
    • /
    • 2005
  • The present study investigated the effect of relative position of the blade on blade surface heat transfer. The experiments were conducted in a low speed wind tunnel with a stationary annular turbine cascade. The test section has a single turbine stage composed of sixteen guide vanes and blades. The chord length of the blade is 150 mm and the mean tip clearance of the blade is $2.5\%$ of the blade chord. The Reynolds number based on blade inlet velocity and chord length is $1.5{\times}105$ and mean turbulence intensity is about $3\%$. To investigate the effect of relative position of blade, the blade at six different positions in a pitch was examined. For the detailed mass transfer measurements, a naphthalene sublimation technique was used. In general, complex heat transfer characteristics are observed on the blade surface due to various flow characteristics, such as a laminar flow separation, relaminarization, flow acceleration, transition to turbulence and tip leakage vortices. The results show that the blade relative position affects those heat transfer characteristics because the distributions of incoming flow velocity and turbulence intensity are changed. Especially, the heat transfer pattern on the near-tip region is significantly affected by the relative position of the blade because the effect of tip leakage vortex is strongly dependent on the blade position. On the pressure side, the effect of blade position is not so significant as on the suction side surface although the position and the size of the separation bubble are changed.

A Study on the Shaping Ability of Three Different Rotary Nickel-Titanium Instruments in Simulated Curved Root Canal (만곡 근관에서 다양한 엔진 구동형 Nickel-Titanium 파일의 근관 성형능력에 대한 연구)

  • Kim, Kyoung-A;Chon, Seong-Min;Kwon, Su-Mi;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.293-302
    • /
    • 2007
  • I. Objectives The purpose of this study was to compare the shaping ability between the single length technique performed with Mtwo instruments (VDW, Munich, Germany) and the crown-down technique using K3 (SybronEndo, West Collins, CA, USA) and RaCe (FKG, La Chaux-de-Fonds, Switzerland) instruments. II. Materials & Methods Forty five curved canals in resin blocks were equally divided in to three groups. Group 1 (Mtwo) was instrumented used the full length of canal according to the manufacturer's instructions. The simulated canals was prepared to an instrument size of 35, 0.04 taper canal terminus. In group 2 (Race) and group 3 (K3) was instrumented in a crown-down manner and prepared to an instrument size of 30, 0.06 taper canal terminus. Pre- and post-instrumentation images were scanned and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 7 measuring points, beginning 1mm from the end point of preparation. Differenced of centering ratio were statistically analyzed using One-way ANOVA followed by Duncan's test. II. Results & Conclusion There was no significant difference on 1, 2, 3 and 7mm measuring point. At 4 and 5 measuring point, significant difference showed between the Mtow instruments and other two instruments. (p<0.05)