• Title/Summary/Keyword: Single gamma

Search Result 659, Processing Time 0.024 seconds

Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique (렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.

Effect of Ethyl Alcohol Fraction of Cervus nippon on Mouse T-Lymphocyte (녹용 에탄올 분획이 생쥐의 T-Lymphocyte에 미치는 영향)

  • Suh, Jeong-Sook;Oh, Chan-Ho;Yum, Jung-Yul;Eun, Jae-Soon;Jeon, Kil-Ja
    • Korean Journal of Pharmacognosy
    • /
    • v.29 no.4
    • /
    • pp.312-317
    • /
    • 1998
  • In this study, the effect of 70% ethyl alcohol fraction of Cervus nippon(CN-E) on mouse T-lymphocyte was investigated in vivo. The administration of CN-E(100 mg/kg) enhanced the proliferation of thymocytes, the population of $CD4^+CD8^-$ single-positive cells and the production of $interferon-{\gamma}$ in thymocytes and splenocytes. The administration of CN-E did not induce DNA fragmentation and reduce mitochondrial transmembrane potential in thymocytes. These results indicate that the CN-E contams a stimulative component on the proliferation of thymocytes, the population of $T_H$ cells and the production of $interferon-{\gamma}$ in T-lymphocytes.

  • PDF

A Study on the Microstructures of Rapidly Solidified Ti-($45{\sim}58at%$)Al Intermetallic Compound (급속응고된 TiAl 금속간화합물의 Al함량 변화에 따른 미세조직변화에 관한 연구)

  • Kim, Jae-Hoon;Jeoung, Tae-Ho;Nam, Tae-Woon
    • Journal of Korea Foundry Society
    • /
    • v.18 no.6
    • /
    • pp.550-554
    • /
    • 1998
  • The microstructures of rapidly solidified binary Ti-Al alloys containing $45{\sim}58\;at%Al$ have been studied using C/S (carbon/sulfur), N/O (nitrogen/oxygen) analyser, X-ray fluorescence spectrometer (XRF), X-ray diffractometer (XRD), optical microscope (OM) and scanning electron microscope (SEM). The phases present in the alloys and their distribution were found to be a sensitive function of Al content. Essentially single-phase (${\gamma}$) microstructures were observed to alloys with 45 at%Al, 55 at%Al and 58 at%Al. In other content alloys, two phase (${\alpha}_2$, ${\gamma}$) microstructures were observed. The 48 at%Al, 52 at%Al alloys contain (${\gamma}+{\alpha}_2$) phase and ${\alpha}_2$ phase. These results indicate that rapid solidification affect the solidification path, then metastable phase forming during solidification.

  • PDF

Effect of Baicalin on the Ex vivo Production of Cytokines in Pristane-Induced Lupus Mice (프리스탄 유도한 루푸스 생쥐에서 사이토카인 Ex vivo 생산에 미치는 Baicalin의 효과)

  • Chae, Byeong Suk
    • YAKHAK HOEJI
    • /
    • v.60 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • Systemic lupus erythematosus (SLE) is characterized by dysregulatory production of proinflammatory cytokines and helper T (Th) cytokine-dependent autoantibody production. This study aims to investigate the protective effect of baicalin on the dysregulatory production of proinflammatory cytokines and Th cytokines in pristane-induced lupus mice. Mice were received i.p. a single injection of 0.5 ml of pristane, and then, later about 3 months, were used as a pristane-induced lupus model. The pristane-induced lupus mice were administrated orally with baicalin 50 mg/kg once in a day for 10 days. Immune cells obtained from the pristane-primed lupus control group (lupus control) and baicalin-treated pristaneprimed lupus mouse group (BAC lupus) were cultured for 24 h or 36 h with/without mitogens. These results demonstrated that LPS-induced production of macrophage and splenic TNF-${\alpha}$ and Con A-induced production of thymic IFN-${\gamma}$ were attenuated in BAC lupus compared to lupus control, while LPS-stimulated production of macrophage IL-10, Con A-stimulated production of splenic IL-10 and, $PGE_2$-reduced production of splenic IFN-${\gamma}$ enhanced. Therefore, these findings suggest that baicalin may protect from autoimmunity and disease activity in lupus via modulatory effect of proinflammatory cytokine overproduction and Th cytokine imbalance.

Background reduction by Cu/Pb shielding and efficiency study of NaI(TI) detector

  • Ramadhan, Revink A.;Abdullah, Khairi MS.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.462-469
    • /
    • 2018
  • The background spectrum of a $3^{{\prime}{\prime}}{\times}3^{{\prime}{\prime}}$ NaI(Tl) well-type scintillation SILENA detector was measured without shielding, in 6 cm thick lead shielding, and with 2 mm thick electrolytic copper covering the detector inside the lead shielding. The relative remaining background of the lead shield lined with copper was found to be ideal for low-level environmental radioactive spectroscopy. The background total count rate in the (20-2160 KeV) was reduced 28.7 times by the lead and 29 times by the Cu + Pb shielding. The effective reduction of background (1.04) by the copper mainly appeared in the energy range from X-ray up to 500 KeV, while for the total energy range the ratio is 1.01 relative to the lead only. In addition, a strong relation between the full-energy peak absolute efficiency and the detector well height was found using gamma-ray isotropic radiation point sources placed inside the detector well. The full-energy peak efficiency at a midpoint of the well (at 2.5 cm) is three times greater than that on the detector surface. The energy calibrations and the resolution of any single energy line are independent of the locations of the gamma source inside or outside of the well.

Stereotactic Radiosurgery

  • Chung, Hyun-Tai;Lee, Dong-Joon
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.63-70
    • /
    • 2020
  • Stereotactic radiosurgery is one of the most sophisticated forms of modern advanced radiation therapy. Unlike conventional fractionated radiotherapy, stereotactic radiosurgery uses a high dose of radiation with steep gradient precisely delivered to target lesions. Lars Leksell presented the principle of radiosurgery in 1951. Gamma Knife® (GK) is the first radiosurgery device used in clinics, and the first patient was treated in the winter of 1967. The first GK unit had 179 cobalt 60 sources distributed on a hemispherical surface. A patient could move only in a single direction. Treatment planning was performed manually and took more than a day. The latest model, Gamma Knife® IconTM, shares the same principle but has many new dazzling characteristics. In this article, first, a brief history of radiosurgery was described. Then, the physical properties of modern radiosurgery machines and physicists' endeavors to assure the quality of radiosurgery were described. Intrinsic characteristics of modern radiosurgery devices such as small fields, steep dose distribution producing sharp penumbra, and multi-directionality of the beam were reviewed together with the techniques to assess the accuracy of these devices. The reference conditions and principles of GK dosimetry given in the most recent international standard protocol, International Atomic Energy Agency TRS 483, were shortly reviewed, and several points needing careful revisions were highlighted. Understanding the principles and physics of radiosurgery will be helpful for modern medical physicists.

Fabrication of $Li_2B_4O_7$ Series Single-Crystal TLDs and their TL properties ($Li_2B_4O_7$ 계열 단결정 TLD 소자의 제작과 특성)

  • Park, Myeong-Hwan;Park, Kang-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • High-quality single crystals of pure $Li_2B_4O_7$ as well as $Li_2B_4O_7$ doped with Cu, Mn and Mg impurities (1.0mol%, respectively) have been grown from the melt of $Li_2CO_3+2B_2O_3$ by Czochralski method in platinum crucibles. To study the thermoluminescent properties, $Li_2B_4O_7$ series single crystal TLDs were made by cutting in the size of $4{\times}5{\times}1\;mm^3$. The glow curves show two or three peaks which can be easily deconvoluted. It is observed that room temperature($20{\sim}30^{\circ}C$) fadings of the dosimetric peaks of $Li_2B_4O_7$ series single crystal TLDs were about 10 % for 30 days. The relative photon energy response for $Li_2B_4O_7$ series single crystal TLDs were about 85 % when the responses were normalized to that measured with $^{60}Co\;(1.25\;MeV)\;{\gamma}-rays$. The measured data are in a good agreement with theoretical ones. The $Li_2B_4O_7$ series single crystal TLDs fabricated in this work can be used for monitoring personal and environmental radioactivity.

  • PDF

The effects of PWHT on the toughness of weld HAZ in Cu-containing HSLA-100 steel (Cu를 함유한 HSLA-100강 용접 열 영향부의 인성에 미치는 후열처리의 영향)

  • 박태원;심인옥;김영우;강정윤
    • Journal of Welding and Joining
    • /
    • v.13 no.4
    • /
    • pp.55-64
    • /
    • 1995
  • A study was made to examine the effects of postweld heat treatment(PWHT) on the toughness and microstructures in the weld heat affected zone(HAZ) of Cu-bearing HSLA-100 steel. The Gleeble thermal/mechanical simulator was used to simulate the weld HAZ. The details between toughness and PWHT of HAZ were studied by impact test, optical microscopy(O.M.), scanning electron microscopy (SEM), transmission electron microscopy(TEM) and differential scanning calorimetry(DSC). The decrease of HAZ toughness in single thermal cycle comparing to base plate is ascribed to the coarsed-grain formed by heating to 1350.deg.C. The increase of HAZ toughness in double thermal cycle comparine to single thermal cycle is due to the fine ferrite(.alpha.) grain transformed from austenite(.gamma.)formed by heating to .alpha./.gamma. two phase region. Cu precipitated during aging for increasing the strength of base metal is dissolved during single thermal cycle to 1350.deg.C and is precipitated little on cooling and heating during subsequent weld thermal cycle. It precipitates by introducing PWHT. Thus, the decrease of toughness in triple thermal cycle of $T_{p1}$ = 1350.deg.C, $T_{p2}$ = 800.deg.C and $T_{p3}$ = 500.deg.C does not occur owing to the precipitation of Cu. The behaviors of Cu=precipitates in HAZ is similar to that in base plate. PWHT at 550.deg.C shows highest hardness and lowest toughness, whereas PWHT at 650.deg.C shows reasonable toughness, which improves the toughness of as-welded state.state.

  • PDF

Analysis of gamma-ray-induced DNA damage in human, mouse and rat peripheral blood lymphocytes using single-cell gel electrophoresis (단세포 전기영동법을 이용한 인체, 마우스 및 랫드 림프구의 방사선에 의해 유발된 DNA 손상 측정)

  • Oh, Heon;Jung, Uhee;Park, Hae-Ran;Kim, Sung-Ho;Jo, Sung-Kee
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.41-47
    • /
    • 2004
  • The alkaline single-cell gel electrophoresis (SCGE) assay, called the comet assay, has been applied to detect DNA damage induced by a number of chemicals and biological factors in vivo and in vitro. The DNA damage was analysed by tail moment (TM) and tail length (TL), which were markers of DNA strand breaks in SCGE. Human, mouse and rat peripheral blood lymphocytes (PBLs) were irradiated with different doses of $^{60}Co$ ${\gamma}$-rays, e.g. 1, 2, 4, and 8 Gy at a dose rate of 1 Gy/min. A dose-dependent increase in TM (p<0.01) and TL (p<0.01) was obtained at all the radiation doses (1-8 Gy) in human, mouse and rat PBLs. Mouse PBLs were more sensitive than human PBLs which were in turn more sensitive than rat PBLs when the treated dosages were 1 and 2 Gy. However, human PBLs were more sensitive than mouse PBLs which were in turn more sensitive than rat PBLs when the irradiation dosages were 4 and 8 Gy. Data from all three species could be fitted to a linear-quadratic model. These results indicated that there may be inherent differences in the radio-sensitivity among PBLs of mammalian species.

Radiosurgical Considerations in the Treatment of Large Cerebral Arteriovenous Malformations

  • Lee, Sung-Ho;Lim, Young-Jin;Choi, Seok-Keun;Kim, Tae-Sung;Rhee, Bong-Arm
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.378-384
    • /
    • 2009
  • Objective : In order to establish the role of Gamma Knife radiosurgery (GKS) in large intracranial arteriovenous malformations (AVMs), we analyzed clinical characteristics, radiological features, and radiosurgical outcomes. Methods : Between March 1992 and March 2005, 28 of 33 patients with large AVMs (> $10\;cm^3$ in nidus-volume) who were treated with GKS underwent single session radiosurgery (RS), and the other 5 patients underwent staged volumetric RS. Retrospectively collected data were available in 23 cases. We analyzed treatment outcomes in each subdivided groups and according to the AVM sizes. We compared the estimated volume, defined as primarily estimated nidus volume using MR images, with real target volume after excluding draining veins and feeding arteries embedded into the nidus. Results : Regarding those patients who underwent single session RS, 44.4% (8/18) had complete obliteration; regarding staged volumetric RS, the obliteration rate was 40% (2/5). The complete obliteration rate was 60% (6/10) in the smaller nidus group ($10-15\;cm^3$ size), and 25% (2/8) in the larger nidus group (over $15\;cm^3$ size). One case of cerebral edema and two cases (8.7%) of hemorrhage were seen during the latent period. The mean real target volume for 18 single sessions of RS was $17.1\;cm^3$ ($10.1-38.4\;cm^3$), in contrast with the mean estimated volume of $20.9\;cm^3$ ($12.0-45.0\;cm^3$). Conclusion : The radiosurgical treatment outcomes of large AVMs are generally poor. However, we presume that the recent development in planning software and imaging devices aid more accurate measurement of the nidus volume, therefore improving the treatment outcome.