• Title/Summary/Keyword: Single cavity

Search Result 465, Processing Time 0.029 seconds

A Study on the Dynamic Behavior of Underground Tunnels with a Cavity (주변 공동을 고려한 터널의 동적거동에 관한 연구)

  • 김민규;이종우;이종세
    • Tunnel and Underground Space
    • /
    • v.12 no.3
    • /
    • pp.171-178
    • /
    • 2002
  • A dynamic analysis of a horseshoe_shaped tunnel near to cavity was performed to study the effect of the cavity on the dynamic behavior of the tunnel. In order to obtain the dynamic response of the tunnel embedded in a semi-infinite domain, a hybrid numerical technique was primarily developed. A dynamic fundamental solution in frequency domain for multi-layered half planes was derived and subsequently incorporated in the boundary element method. Coupling of the boundary element method for the far field with the finite element method for the near field is made by imposing compatibility condition of a displacement at the interface. The boundary element method is then coupled with the finite element method, which is utilized to model the near field including the tunnel and the cavity. In order to demonstrate the validity of the proposed technique, dynamic responses of single and multiply-layered semi-infinite structural systems are obtained by using the Kicker waveform and investigated in the limestone layer to find how the being and the location of the cavity affect the dynamic characteristics of the system.

Establishment of prediction table of parturition day by ultrasonography in Korean Jindo bitches (진도개에서 초음파검사에 의한 분만일 예정표 확립)

  • Kim, Se-ra;Kang, Hyun-gu;Oh, Ki-seok;Park, In-chul;Park, Sang-guk;Kim, Sung-ho;Son, Chang-ho
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.2
    • /
    • pp.373-381
    • /
    • 2000
  • Serial ultrasonographic examinations were performed on pregnant Korean Jindo bitches. Measurements of inner chorionic cavity diameter and fetal head diameter were made from pregnancy day 15 to parturition. These measurements were converted retrospectively based on the day of parturition (day 0). The data of inner chorionic cavity diameter obtained from day -42 to day -25 and fetal head diameter obtained from day -24 to day -1 were used to prediction of parturition day. Formulas for the prediction of parturition day using the method of least squares were derived. These formulas were then used to predict parturition dates based on single measurements of inner chorionic cavity diameter or fetal head diameter in 17 additional pregnant Korean Jindo bitches. Predicted date of parturition was then compared to actual whelping date. In the prediction of parturition based on inner chorionic cavity diameter, 7 of 10 bitches were coincided prediction date and actual whelping date, and the prediction was accurate to within 1 day in 3 of 10 bitches. The prediction of parturition based on fetal head diameter was accurate to within 1 day in 6 of 7 bitches and within 2 days in 1 of 7 bitches. In conclusion, the ultrasound measurement of inner chorionic cavity diameter and fetal head diameter are practical and accurate tool in the prediction of parturition.

  • PDF

Differences in CT Findings According to Sputum Smear Results in Patients with Active Pulmonary Tuberculosis Having a Single Cavity (한 개의 공동이 있는 활동성폐결핵 환자에서 객담도말검사 결과에 따른 흉부CT 소견의 차이)

  • Song, In Sup;Lee, Hwa Yeun;Yoo, Seung Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.6
    • /
    • pp.479-485
    • /
    • 2007
  • Background: The purpose of this study was to evaluate the differences in CT findings according to sputum smear-positive or -negative results in patients with active pulmonary tuberculosis having a single cavity. Methods: A total of 32 patients with active pulmonary tuberculosis having a single cavity on CT were classified into two groups: smear-positive (n=19) and smear-negative (n=13). The CT findings were reviewed retrospectively. The presence of consolidation, the number of lobes showing consolidation, ground-glass opacity, micronodules and nodule, the maximum diameter of the cavity, and the shape and maximum thickness of the cavity wall were assessed. Result: The maximum diameter of the cavity was $33.84{\pm}13.65mm$ and $27.08{\pm}9.04mm $ in the smear-positive and -negative groups, respectively (p>0.05). The amount of consolidation and the number of lobes with consolidation were found to be 89.5% and 30.8% (p=0.01) and $1.37{\pm}0.90$ and $0.31{\pm}0.48$ (p=0.0002) in the smear-positive and -negative groups, respectively. Consolidations in two or more lobes were only noted in 31.6% of in the sputum smear- positive group (p< 0.05). There were no other significant differences between the two groups. The sensitivity, specificity, positive and negative predictive values for the presence of consolidation were 89.5%, 69.2%, 73.9%, and 81.8%, respectively. Conclusion: While the absence of consolidation on CT may be associated with sputum smear-negative results in patients with active pulmonary tuberculosis having a single cavity, the presence of consolidation in two or more lobes on CT may be associated with spear-positive results in these patients.

Crystal Growth of Superconducting $YBa_2Cu_3O_{7-x}$ Single Crystals ($YBa_2Cu_3O_{7-x}$초전도 단결정 성장)

  • 정광철;오근호;최종건
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.4
    • /
    • pp.536-542
    • /
    • 1990
  • Single crystals of YBa2Cu3O7-x have been grown in BaCuO2 flux at temperature of 125$0^{\circ}C$ and examined using XRD, EDAX and light microscopy. The YBCO crystals were grown in a cavity which was formed by the reduction of CuO and became large by the directional solidification in the crucible. The observed crystal growth habit is square planar with the c-axis normal to the plane. The surface morphology of grown crystals were growth ledges and growth sprial paterns on a (001) face.

  • PDF

Construction and Study of Longitudinally Pumped single Mode Pulsed Dye Laser (종펌핑 단일 종모드 섹소레이저 제작 및 특성연구)

  • 이종훈
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.43-45
    • /
    • 1989
  • Single mode pulsed incidence dye laser which has TEMoo spatial beam pattern, near gaussian temporal shape and narrow band width(less than 500MHz) has been constructed The improved performance comes as a results of cavity length(~5cm) and definition of optical path by means of longitudinal pumping. Using 1.0X10-4M RH-6G dye, conversion efficiency was approximately 2.2% and tuning range was 548-564nm.

  • PDF

Single Mode Lasing in InGaAsP/InP Semiconductor Coupled Square Ring Cavities

  • Hyun, Kyung-Sook;Lee, Taekyu;Moon, Hee-Jong
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.157-161
    • /
    • 2012
  • This work reports the stability of the resonant characteristics in multimode interferometer coupled square ring semiconductor cavities. Based on the analysis of single square ring cavities, the single mode operations in the multimode interferometer coupled ring cavities are analyzed and the devices are demonstrated on the semiconductor multiple quantum well epitaxial structure. By varying the lasing conditions such as substrate temperature and input pump power, single resonant mode operations are also observed.

Single Incision Flexible Endoscopic Cholecystectomy in Dogs : Feasibility Study (개에서 단일 통로 유연 내시경 담낭 절제술 : 유용성 연구)

  • Lee, So-Yeon;Shin, Beom-Jun;Jeong, Seong-Mok
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.555-561
    • /
    • 2011
  • Laparoscopic surgery is a well-established alternative to open surgery across disciplines. However, in veterinary medicine, laparoscopic surgery in dogs was rarely reported because of small abdominal size for multiple ports insertion. The concept of single-incision laparoscopic surgery (SILS) is to perform the entire laparoscopic operation through a single incision rather than conventional multiple small skin incisions. Indirect evidence of potential benefits of SILS, decreases operative morbidity related to reduction in port size, already exists. Therefore, this study was performed to evaluate the safety and feasibility of the modified form of SILS using flexible endoscope in Cholecystectomy before clinical adoption. A 2 cm single periumbilical incision was performed, and flexible endoscope was introduced into the abdominal cavity. A laparoscopic grasper was inserted into the abdominal cavity for the traction of gall bladder. Cystic duct and artery were ligated by 5 mm Hem-o-lok$^{(R)}$. Then, gall bladder was dissected and resected from the liver with 5 mm Autonomy Laparo-Angle Maryland dissector and endoscopic needle knife. Resected gall bladder was wrapped by using specimen pouch and was retrieved through abdominal incision from the cavity. All three gall bladders were successfully removed. Hematological changes were not observed during examination periods. No leakage sign was identified at necropsy. The flexible endoscope, as distinct from conventional rigid laparoscope, allows the visualization from various angles and the wide range of motion, result in less crowding.