• Title/Summary/Keyword: Single Supply

Search Result 1,063, Processing Time 0.03 seconds

Analysis of Operation Plan by Multipurpose Supply for Heightened Agricultural Reservoir (둑높임저수지 다중용수공급에 따른 운영 방안 분석)

  • Kim, Hae Do;Lee, Kwang Ya;Park, Jong Yoon;Han, Guk Heon;Lim, Heung Chang
    • KCID journal
    • /
    • v.19 no.1
    • /
    • pp.77-86
    • /
    • 2012
  • The aim of this study was to analyze the operation plan for heightened agricultural reservoir, in terms of water supply to downstream paddy fields and instreams. Operation of agricultural reservoir before the heightened reservoir project is easy to manage because of its single purpose, which is irrigation water supply. However, after proceeding the heightened project, there is needed to be set the operation rule because of its multiple purpose, which is water for irrigation and supply to the stream. In this paper, propose the method of design the criteria of supply to the stream and operation rule curve for the heightened reservoir. According to simulation results by proposed operating rule for the Gumsa reservoir, the yearly amount of water supply to the stream can be 2,588 thousand $m^3$, 3 times of the heightened space (2,588 thousand $m^3$).

  • PDF

Input-Series Multiple-Output Auxiliary Power Supply Scheme Based on Transformer-Integration for High-Input-Voltage Applications

  • Meng, Tao;Ben, Hongqi;Wei, Guo
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.439-447
    • /
    • 2012
  • In this paper, an input-series auxiliary power supply scheme is proposed, which is suitable for high input voltage and multiple-output applications. The power supply scheme is based on a two-transistor forward topology, all of the series modules have a common duty ratio, all the switches are turned on and off simultaneously, and the whole circuit has a single power transformer. It does not require an additional controller but still achieves efficient input voltage sharing (IVS) for each series module through its inherent transformer-integration strategy. The IVS process of this power supply scheme is analyzed in detail and the design considerations for the related parameters are given. Finally, a 100W multiple-output auxiliary power supply prototype is built, and the experimental results verify the feasibility of the proposed scheme and the validity of the theoretical analysis.

Integrated Vehicle Routing Model for Multi-Supply Centers Based on Genetic Algorithm (유전자알고리즘 및 발견적 방법을 이용한 차량운송경로계획 모델)

  • 황흥석
    • Journal of the Korea Society for Simulation
    • /
    • v.9 no.3
    • /
    • pp.91-102
    • /
    • 2000
  • The distribution routing problem is one of the important problems in distribution and supply center management. This research is concerned with an integrated distribution routing problem for multi-supply centers based on improved genetic algorithm and GUI-type programming. In this research, we used a three-step approach; in step 1 a sector clustering model is developed to transfer the multi-supply center problem to single supply center problems which are more easy to be solved, in step 2 we developed a vehicle routing model with time and vehicle capacity constraints and in step 3, we developed a GA-TSP model which can improve the vehicle routing schedules by simulation. For the computational purpose, we developed a GUI-type computer program according to the proposed methods and the sample outputs show that the proposed method is very effective on a set of standard test problems, and it could be potentially useful in solving the distribution routing problems in multi-supply center problem.

  • PDF

Standardization for receive and supply of electric power facility of airport (공항 수.배전 설비 표준화)

  • 최홍규;원진희;송영주;조계술
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.349-354
    • /
    • 2003
  • Airport facility is infrastructure that become external creditworthiness and linear measure of country competitive power. Among them, receive and supply of electric power facility of airport is very important in peculiarity, trustability, safety side of airport. In this parer, sorted domestic airline as 4 classes by code to accomplish standardization for receive and supply of electric power facility of airport. And established justice and coverage about receive and supply of electric power facility using without any standard present and analyze problem for receive and supply of electric power facility of existing airport and presents standard. Finally, present standard single-line diagram by airport grade and system grade standard of receive and supply of electric power facility of airport.

  • PDF

Design of Gate Driver Power Supply for 3-Phase Inverter Using SiC MOSFET (SiC MOSFET를 사용한 3상 인버터용 게이트 드라이버 전원 설계)

  • Lee, Sangyong;Chung, Se-Kyo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.429-436
    • /
    • 2021
  • The design of a gate driver power supply for a three-phase inverter using a silicon carbide (SiC) MOSFET. The requirements for the power supply circuit of the gate driver for the SiC MOSFET are investigated, and a flyback converter using multiple transformers is used to make the four isolated power supplies. The proposed method has the advantage of easily constructing the power supply circuit in a limited space as compared with a multi-output flyback converter using a single core. The power supply circuit for the three-phase SiC MOSFET inverter for driving an AC motor is designed and implemented. The operation and validity of the implemented circuit are verified through simulations and experiments.

A New Programming Method of Scaled SONOS Flash Memory Ensuring 1$\times$10$^{6}$ Program/Erase Cycles and Beyond (1x10$^{6}$ 회 이상의 프로그램/소거 반복을 보장하는 Scaled SONOS 플래시메모리의 새로운 프로그래밍 방법)

  • 김병철;안호명;이상배;한태현;서광열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.54-57
    • /
    • 2002
  • In this study, a new programming method, to minimize the generation of Si-SiO$_2$ interface traps of scaled SONOS flash memory as a function of number of program/erase cycles has been proposed. In the proposed programming method, power supply voltage is applied to the gate, forward biased program voltage is applied to the source and the drain, while the substrate is left open, so that the program is achieved by Modified Fowler-Nordheim (MFN) tunneling of electron through the tunnel oxide over source and drain region. For the channel erase, erase voltage is applied to the gate, power supply voltage is applied to the substrate, and the source and drain are open. A single power supply operation of 3 V and a high endurance of 1${\times}$10$\^$6/ prograss/erase cycles can be realized by the proposed programming method. The asymmetric mode in which the program voltage is higher than the erase voltage, is more efficient than symmetric mode in order to minimize the degradation characteristics of scaled SONOS devices because electrical stress applied to the Si-SiO$_2$ interface is reduced by short programming time.

  • PDF

Single-Stage Single-Switched AC/DC Converter with Magnetic Coupled Nondissipative Snubber (자기결합 무손실 스너버를 갖는 새로운 고역률 단일전력단 AC/DC 컨버터)

  • 조정욱;문건우;정영석;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.423-431
    • /
    • 1997
  • A new single-stage/single-switched forward converter with magnetic coupled nondissipa-tive snubber is proposed. The proposed converter gives the good power factor correction (PFC), low current harmonic distortion, and tight output voltage regulation. The prototype shows the IEC 555-2 requirements are met satisfactorily with nearly unity power factor. This proposed converter with magnetic coupled nondissipative snubber is particularly suited for low power level power supply applications.

  • PDF

How Quick Response affects the Supply Chain Performance

  • RYU, Chungsuk
    • Journal of Distribution Science
    • /
    • v.17 no.7
    • /
    • pp.87-98
    • /
    • 2019
  • Purpose - The goal of this research is to examine the influence of Quick Response on the supply chain performance. Furthermore, this study investigates the potential of Quick Response to be a more advanced form of supply chain collaboration program with extensive information sharing activities. Research design, data, and methodology - The mathematical model is developed to represent the two stage supply chain system with a single manufacturer and one retailer. In the numerical study with the proposed mathematical models, three supply chain systems including the traditional system, Quick Response, and the fully shared information system are compared in terms of their profits. Results - The numerical analysis shows both manufacturer and retailer obtain greater profits under Quick Response than in the traditional system. While the fully shared information outperforms Quick Response as well as the traditional system, it results in lower manufacturer's profit compared with Quick Response. Conclusions - According to the numerical examples, Quick Response is the effective supply chain collaboration program that is beneficial to every supply chain member. The fully shared information system, as a more advanced form of collaboration than Quick Response can bring more benefits to the whole supply chain system, but it is necessary to prepare the proper incentive program that enables every member to share its benefits equally.

An Inventory Rationing Method in a M-Store Regional Supply Chain Operating under the Order-up-to Level System

  • Monthatipkul, Chumpol
    • Industrial Engineering and Management Systems
    • /
    • v.8 no.2
    • /
    • pp.80-92
    • /
    • 2009
  • This paper addresses the inventory rationing issue embedded in the regional supply chain inventory replenishment problem (RSIRP). The concerned supply chain, which was fed by the national supply chain, consisted of a single warehouse distributing a single product to multiple stores (M-stores) with independent and normally distributed customer demand. It was assumed that the supply chain operated under the order-up-to level inventory replenishment system and had only one truck at the regional warehouse. The truck could make one replenishment trip to one store per period (a round trip per period). Based on current inventories and the vehicle constraint, the warehouse must make two decisions in each period: which store in the region to replenish and what was the replenishment quantity? The objective was to position inventories so as to minimize lost sales in the region. The warehouse inventory was replenished in every fixed-interval from a source outside the region, but the store inventory could be replenished daily. The truck destination (store) in each period was selected based on its maximum expected shortage. The replenishment quantity was then determined based on the predetermined order-up-to level system. In case of insufficient warehouse inventories to fulfill all projected store demands, an inventory rationing rule must be applied. In this paper, a new inventory rationing rule named Expected Cost Minimization (ECM) was proposed based on the practical purpose. The numerical results based on real data from a selective industry show that its performance was better and more robust than the current practice and other sharing rules in the existing literature.

Numerical Analysis on the Effects of Supply Channel and Jet Hole Arrangement on Heat Flow Characteristics of Impingement Jet (충돌제트에서의 유량공급 채널 및 제트 홀 배열에 따른 열유동 특성 수치해석)

  • Hwang, Byeong Jo;Chung, Heeyoon;Joo, Won Gu;Cho, Hyung Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.77-86
    • /
    • 2016
  • A numerical analysis is performed to investigate the effect of a supply channel and jet hole arrangement on the heat flow characteristics of impingement jet. The jet holes in a supply channel are composed of a single or staggered array from the center of a leading edge channel. The software ICEMCFD is used to generate the structured grids for calculation domain and a CFD code CFX 15.0 to perform the simulation. The present solutions are validated by comparison with the experimental and numerical ones of others. A comparison of mass flow rates of impingement jets and Nusselt numbers on the impingement surface for the single or staggered arrays is made.