• Title/Summary/Keyword: Single Sensor

Search Result 1,577, Processing Time 0.027 seconds

Design of electronic tongue using IEEE 1451.2 (IEEE 1451.2를 이용한 전자혀 설계)

  • Kim, Dong-Jin;Kim, Jeong-Do;Jung, Woo-Suk;Lee, Jung-Hwan;Kim, Myung-Guy;Yoon, Chul-Oh
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.150-158
    • /
    • 2007
  • The IEEE 1451 publication are available, this standard defines interface between sensor and processor, and plug and play in processor is possible. Also, Intelligence of sensor was possible because sensor includes transducer electronic data sheet (TEDS). In IEEE 1451 standards, IEEE 1451.4 is suitable standard in single sensor, and IEEE 1451.2 is suitable standard in multi-sensors (array sensor). In this paper, apply IEEE 1451 to electronic tongue system. In the case of electronic tongue system, because array sensor is used, it is that complex and difficult to apply IEEE 1451.4 that is standard for single sensor. In this paper, apply IEEE 1451.2 for array sensor to design of electronic tongue system. Communication interface method of IEEE 1451.2 for electronic tongue system is presented, and implemented TEDS of electronic tongue system.

Design of a MEMS sensor array for dam subsidence monitoring based on dual-sensor cooperative measurements

  • Tao, Tao;Yang, Jianfeng;Wei, Wei;Wozniak, Marcin;Scherer, Rafal;Damasevicius, Robertas
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.10
    • /
    • pp.3554-3570
    • /
    • 2021
  • With the rapid development of the Chinese water project, the safety monitoring of dams is urgently needed. Many drawbacks exist in dams, such as high monitoring costs, a limited equipment service life, long-term monitoring difficulties. MEMS sensors have the advantages of low cost, high precision, easy installation, and simplicity, so they have broad application prospects in engineering measurements. This paper designs intelligent monitoring based on the collaborative measurement of dual MEMS sensors. The system first determines the endpoint coordinates of the sensor array by the coordinate transformation relationship in the monitoring system and then obtains the dam settlement according to the endpoint coordinates. Next, this paper proposes a dual-MEMS sensor collaborative measurement algorithm that builds a mathematical model of the dual-sensor measurement. The monitoring system realizes mutual compensation between sensor measurement data by calculating the motion constraint matrix between the two sensors. Compared with the single-sensor measurement, the dual-sensor measurement algorithm is more accurate and can improve the reliability of long-term monitoring data. Finally, the experimental results show that the dam subsidence monitoring system proposed in this paper fully meets the engineering monitoring accuracy needs, and the dual-sensor collaborative measurement system is more stable than the single-sensor monitoring system.

The Mobile Robot Localizaion Using a Single Sonalr and Cylindrical Beacon (초음파 센서와 실린더형 등대를 이용한 이동 로봇의 위치 추정)

  • 범희락;조형석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.570-574
    • /
    • 1993
  • This paper proposes a new method of estimating the position and heading angle of a mobile robot moving on a flat surface. The proposed localization method utilizes two passive beacons and a single rotating ultrasonic sensor. The passive beacons consist of two cylinders with different diameters and reflect the ultrasonic pulses coming from the sonar sensor mounted on the mobile robot. The geometric parameter set of beacon is acquired from the sonar scan data obtained at a single mobile robot location using a new data processing algorithm. Form this parameter set, the position and heading angle of the mobile robot is determined directly. The performance and validity of the proposed method are evaluated using two beacons and a single sonar sensor attached at the pan-tilt device mounted on a mobile robot, named LCAR, in our laboratory.

  • PDF

Design of a CMOS Image Sensor Based on a 10-bit Two-Step Single-Slope ADC

  • Hwang, Yeonseong;Song, Minkyu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.246-251
    • /
    • 2014
  • In this paper, a high-speed CMOS Image Sensor (CIS) based on a 10-bit two step Single Slope A/D Converter (SS-ADC) is proposed. The A/D converter is composed of both 5-bit coarse ADC and a 6-bit fine ADC, and the conversion speed is 10 times faster than that of the single-slope A/D convertor. In order to reduce the pixel noise, further, a Hybrid Correlated Double Sampling (H-CDS) is also discussed. The proposed A/D converter has been fabricated with 0.13um 1-poly 4-metal CIS process, and it has a QVGA ($320{\times}240$) resolution. The fabricated chip size is $5mm{\times}3mm$, and the power consumption is about 35 mW at 3.3 V supply voltage. The measured conversion speed is 10 us, and the frame rate is 220 frames/s.

Fiber-Optic Temperature Sensor Based on Single Mode Fused Fiber Coupler

  • Kim, Kwang-Taek;Park, Kiu-Ha
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.152-156
    • /
    • 2008
  • This paper reports a fiber-optic temperature sensor using a single mode fused fiber coupler incorporating a thermo-optic external medium. The spectral transmission was altered by changing the refractive index of the external thermo-optic medium. A theoretical and experimental investigation was carried out with the aim of achieving high sensitivity. The measured sensitivity for the environmental temperature was as high as -1.5 $nm/^{\circ}C$.

Study on Fiber Polarimetric Vibration Sensor Based on Polarization-Maintaining Photonic Crystal Fiber (편광유지 광자결정 광섬유 기반 편광 간섭형 진동 센서)

  • Kim, Young-Suk;Park, Kyongsoo;Lee, Yong Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.13-18
    • /
    • 2015
  • In this paper, we implemented a polarimetric vibration sensor using a Sagnac birefringence interferometer composed of polarization-maintaining photonic crystal fiber(PM-PCF). By changing the amplitude and frequency of vibration applied to PM-PCF employed as the sensor head of the proposed sensor, sensor responses to various types of vibration were investigated. First, the vibration characteristic of the sensor was explored for a single frequency in a frequency range from 1 to 3000Hz with a cylindrical piezoelectric transducer, and then the sensor response to naturally damped vibration was examined by utilizing a metal cantilever. It was experimentally observed that the sensor output signal was deteriorated by more than 3dB at ~1900Hz in the single frequency vibration measurement with a minimum detectable strain perturbation of ${\sim}1.34n{\varepsilon}/Hz^{1/2}$ at 1500Hz and the peak value of the sensor output signal was proportional to the strength of initially applied stress in the naturally damped vibration measurement.

Modal identification of time-varying vehicle-bridge system using a single sensor

  • Li, Yilin;He, Wen-Yu;Ren, Wei-Xin;Chen, Zhiwei;Li, Junfei
    • Smart Structures and Systems
    • /
    • v.30 no.1
    • /
    • pp.107-119
    • /
    • 2022
  • Modal parameters are widely used in bridge damage detection, finite element model (FEM) updating and design optimization. However, the conventional modal identification approaches require large number of sensors, enormous data processing workload, but normally result in mode shapes with low accuracy. This paper proposes a modal identification method of time-varying vehicle-bridge system using a single sensor. Firstly, the essential physical relationship between the instantaneous frequency of the vehicle-bridge system and the bridge mode shapes are derived. Subsequently, based on the synchroextracting transform, the instantaneous frequency of the system is tracked through the dynamic response collected by a single sensor, and further the modal parameters are estimated by using the derived physical relationship. Then numerical and experimental examples are conducted to examine the feasibility and effectiveness of the proposed method. Finally, the modal parameters identified by the proposed method are applied in bridge FEM updating. The results manifest that the proposed method identifies the modal parameters with high accuracy via a single sensor, and can provide reliable data for the FEM updating.

Enhancement of Electrocatalytic Activity upon the Addition of Single Wall Carbon Nanotube to the Redox-hydrogel-based Glucose Sensor

  • Kim, Suk-Joon;Quan, Yuzhong;Ha, Eunhyeon;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.33-37
    • /
    • 2021
  • In electrochemical glucose sensing, the enhancement of the sensitivity and the response time is essential in developing stable and reliable sensors, especially for continuous glucose monitoring. We developed a method to increase the sensitivity and to shorten the response time for the sensing upon the appropriate addition of single wall carbon nanotube onto the osmium polymer-based hydrogel electrode. Also, the background stabilization is dramatically enhanced.

An Efficient Routing Protocol for Mobile Sinks in Sensor Networks (센서 네트워크에서 모바일 싱크를 위한 효율적인 라우팅 기법)

  • Wu, Mary
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.4
    • /
    • pp.640-648
    • /
    • 2017
  • Sensors have limited resources in sensor networks, so efficient use of energy is important. In order to use the energy of the sensor node efficiently, researches applying mobile sink to the sensor network have been actively carried out. The sink node moves the sensor network, collects data from each sensor node, which spread the energy concentrated around the sink node, thereby extending the entire life cycle of the network. But, when the sink node moves, it requires a reset of the data transmission path, which causes a lot of control messages and delays. In this paper, we propose a CMS(Cluster-based Mobile Sink) method to support the movement of mobile sink in a cluster sensor environment. The proposed scheme minimizes an amount of control messages without resetting the routing paths of entire sensor networks by supporting the sink mobility path using the neighbor cluster list. And, it simplifies the routing path setup process by setting a single hop path between clusters without a gateway. The experiment results show that the proposed scheme has superior energy efficiency in processing and network structure, compared with existing clustering and mesh routing protocols.

A Single Lens Micro-Angle Sensor

  • Saito, Yusuke;Gao, Wei;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.14-19
    • /
    • 2007
  • Angle sensors based on the principle of autocollimation, which are usually called autocollimators, can accurately measure small tilt angles of a light-reflecting flat surface. This paper describes a prototype micro-angle sensor that is based on the laser autocollimation technique. The new angle sensor is compact and consists of a laser diode as the light source and a quadrant photodiode as a position-sensing device. Because of its concise design, the microangle sensor facilitates dynamic measurements of the angular error motions of a precision stage without influencing the original dynamic properties of the stage. This is because the sensor only requires a small extra target mirror to be mounted on the stage. The sensitivity of the angle detection is independent of the focal length of the objective lens; therefore, an objective lens with a relatively short focal length is employed to reduce the size of the device. The micro-angle sensor uses a single lens for the both the laser collimation and focusing, which distinguishes it from the conventional laser autocollimation method that has separate collimate and objective lenses. The new micro-angle sensor has dimensions of $15.1\times22.0\times14.0mm$ and its resolution is better than 0.1 arc-second The optical design and performance of this micro-angle sensor were verified by experimental results.