• Title/Summary/Keyword: Single Material

Search Result 3,428, Processing Time 0.027 seconds

Mid- and Long Term Outcome of Fontan Procedure: Extracardiac Conduit Fontan versus Lateral Tunnel Fontan (폰탄 술식의 중장기 성적: 심장외 도관 술식과 가측터널 술식의 비교)

  • Kwak, Jae-Gun;Kim, Dong-Jung;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.805-810
    • /
    • 2007
  • Background: This paper reviews our experience retrospectively to examine the clinical results and effectiveness of lateral tunnel (LT) and extracardiac conduit (ECC) Fontan procedures at a single institution. Material and Method: One hundred and sixty five Fontan procedures were performed (67 LT and 98 ECC) between January 1996 and December 2006. Preoperative and postoperative hemodynamic values, arrhythmia, hospital and intensive care unit stay, chest tube drain, morbidity and mortality were reviewed. Result: The overall operative mortality in the LT and ECC groups was 4.5% (3) and 2.0% (2), respectively. There was a significant difference in the immediate postoperative transpulmonary gradient (LT $8.5{\pm}2.5$ vs ECC $6.6{\pm}2.4$, p-value<0.001) and central venous pressure (LT $18.3{\pm}3.8$ vs ECC $15.6{\pm}2.4$, p-value=0.001) between the two groups. The mean follow-up in the LT and ECC groups was $74.1{\pm}31.5$ and $38.1{\pm}29.1$ months, respectively. There was one late death. The actuarial survival at 10 years in the LT and ECC groups was 92% and 89%, respectively. In arrhythmia, the ECC patients showed a slightly low incidence but the difference was not statistically significant. Conclusion: Both the LT and ECC Fontan procedures showed comparable early and mid-term outcomes in terms of the surgical morbidity and mortality, postoperative hemodynamics, and mid-term survival. The ECC Fontan procedure reduces the risk of arrhythmia in the follow up period.

Factors Affecting Wet-Paddy Threshing Performance (탈곡기의 제작동요인이 벼의생탈곡성능에 미치는 영향)

  • 남상일;정창주;류관희
    • Journal of Biosystems Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-14
    • /
    • 1980
  • Threshing operation may be one of the most important processes in the paddy post-production system as far as the grain loss and labor requirement are concerned . head-feeding type threshers commercially available now in Korea originally were developed for threshing dry paddy in the range of 15 to 17 % in wet basis. However, threshing wet-paddy with the grain moisture content above 20 % has been strongly recommended, especially for new high-yielding Indica -type varieties ; (1) to reduce high grain loss incurred due to the handling operations, and (2) to prevent the quantitative and qualitative loss of milled -rice when unthreshed grains are rewetted due to the rainfall. The objective of this study were to investigate the adaptability of both a head-feeding type thresher and a throw-in type thresher to wet-paddy , and to find out the possiblilities of improving the components of these threshers threshing. Four varieties, Suweon 264 and Milyang 24 as Tongil sister line varieties, minehikari and Jinhueng as Japonica-type varieties, were used at the different levels of the moisture content of grains. Both the feed rate and the cylinder speed were varied for each material and each machine. The thresher output quality , composition of tailing return, and separating loss were analyzed from the sampels taken at each treatment. A separate experiment for measurement opf the power requirement of the head-feeding type thresher was also performed. The results are summarized as follows : 1. There was a difference in the thresher output quality between rice varieties. In case of wet-paddy threshing at 550 rpm , grains with branchlet and torn heads for the Suweon 264 were 12 % and 7 % of the total output in weight, respectively, and for the Minehikari 4.5 % and 2 % respectively. In case of dry paddy threshing , those for the Suweon 264 were 8 % and 5% , and for the Minehikari 4% and 1% respectively. However, those for the Milyang 23 , which is highly susceptable to shattering, were much lower with 1 % and 0.5% respectively, regardless of the moisture content of the paddy. Therefore, it is desirable to breed rice varieties of the same physical properties as well as to improve a thresher adaptable to all the varieties. Torn heads, which increased with the moisture content of rall the varieties except the Milyang 23 , decreased as the cylinder speed increased, but grains with branchlet didnt decrease. The damaged kernels increased with the cylinder speed. 3. The thresher output quality was not affected much by the feed rate. But grains with branchlet and torn heads increased slightly with the feed rate for the head-feeding type thresher since higher resistance lowered at the cylinder speed. 4. In order to reduce grains with branchlet and torn heads in wet-paddy threshing , it is desirable to improve the head-feeding type thresher by developing a new type of cylinder which to not give excess impact on kernels or a concave which has differenct sizes of holes at different locations along the cylinder. 5. For the head-feeding type thresher, there was a difference in separating loss between the varieties. At the cylinder speed of 600 rpm the separating losses for the Minehikari and the Suweon 264 were 1.2% and 0.6% respectively. The separating loss of the head-feeding type thresher was not affected by the moisture content of paddy while that of the Mini-aged thresher increased with the moisture content. 6. From the analysis of the tailings return , to appeared that the tailings return mechanism didn't function properly because lots of single grains and rubbishes were unnecessarily returned. 7. Adding a vibrating sieve to the head-feeding type thresher could increase the efficiency of separation. Consequently , the tailing return mechanism would function properly since unnecessary return could be educed greatly. 8. The power required for the head-feeding type thresher was not affected by the moisture content of paddy, but the average power increased linearly with the feed rate. The power also increased with the cylinder speed.

  • PDF

Progress of Composite Fabrication Technologies with the Use of Machinery

  • Choi, Byung-Keun;Kim, Yun-Hae;Ha, Jin-Cheol;Lee, Jin-Woo;Park, Jun-Mu;Park, Soo-Jeong;Moon, Kyung-Man;Chung, Won-Jee;Kim, Man-Soo
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.3
    • /
    • pp.185-194
    • /
    • 2012
  • A Macroscopic combination of two or more distinct materials is commonly referred to as a "Composite Material", having been designed mechanically and chemically superior in function and characteristic than its individual constituent materials. Composite materials are used not only for aerospace and military, but also heavily used in boat/ship building and general composite industries which we are seeing increasingly more. Regardless of the various applications for composite materials, the industry is still limited and requires better fabrication technology and methodology in order to expand and grow. An example of this is that the majority of fabrication facilities nearby still use an antiquated wet lay-up process where fabrication still requires manual hand labor in a 3D environment impeding productivity of composite product design advancement. As an expert in the advanced composites field, I have developed fabrication skills with the use of machinery based on my past composite experience. In autumn 2011, the Korea government confirmed to fund my project. It is the development of a composite sanding machine. I began development of this semi-robotic prototype beginning in 2009. It has possibilities of replacing or augmenting the exhaustive and difficult jobs performed by human hands, such as sanding, grinding, blasting, and polishing in most often, very awkward conditions, and is also will boost productivity, improve surface quality, cut abrasive costs, eliminate vibration injuries, and protect workers from exposure to dust and airborne contamination. Ease of control and operation of the equipment in or outside of the sanding room is a key benefit to end-users. It will prove to be much more economical than normal robotics and minimize errors that commonly occur in factories. The key components and their technologies are a 360 degree rotational shoulder and a wrist that is controlled under PLC controller and joystick manual mode. Development on both of the key modules is complete and are now operational. The Korean government fund boosted my development and I expect to complete full scale development no later than 3rd quarter 2012. Even with the advantages of composite materials, there is still the need to repair or to maintain composite products with a higher level of technology. I have learned many composite repair skills on composite airframe since many composite fabrication skills including repair, requires training for non aerospace applications. The wind energy market is now requiring much larger blades in order to generate more electrical energy for wind farms. One single blade is commonly 50 meters or longer now. When a wind blade becomes damaged from external forces, on-site repair is required on the columns even under strong wind and freezing temperature conditions. In order to correctly obtain polymerization, the repair must be performed on the damaged area within a very limited time. The use of pre-impregnated glass fabric and heating silicone pad and a hot bonder acting precise heating control are surely required.

Analysis of Complications Associated with the Nuss Procedure: Risk Factors and Preventive Measures (너스수술의 합병증에 대한 고찰: 위험인자 분석과 예방책의 제시)

  • Park, Hyung-Joo;Chang, Won-Ho;Jeon, Cheol-Woo;Park, Han-Gyu;Lee, Seock-Yeol;Lee, Cheol-Sae;Youm, Wook;Lee, Kihl-Roh
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.524-529
    • /
    • 2004
  • Background: Since the Nuss procedure for the correction of pectus excavatum is in its early stage, there have been problems that need to be solved. We examined complications in a single-institute experience of the Nuss technique in order to develop possible solutions to prevent them. Material and Method: 335 consecutive patients, who underwent the modified Nuss procedure between August 1999 and October 2002, were studied retrospectively. Median age was 8 years (range 1 to 46). 264 patients (78.8%) were in pediatric group (age$\leq$15) and 71 patients (21.2%) were in adult group (age> 15). 193 patients (57.6%) had symmetric and 142 patients (42.4%) had asymmetric pectus configurations. Risk factors predicting postoperative complications were analyzed using multi-variate logistic regression. Result: Postoperative complication rates were 18.9% (61/335) in total patients. Frequent complications were pneumothorax 24 (7.5%), bar displacement 11 (3.4%), and wound seroma 10 (3.1%) in order. Early complications (within a month, 49 cases, 15.2%) were pneumothorax (n=23, 6.9%), wound seroma (n=12, 3.6%), and bar displacement (n=8, 2.4%). Late complications (after a month, 12 cases, 3.7%) were pericarditis and pericardial effusion (n=5, 1.5%), bar displacement (n=4, 1.2%), and hemothorax (n=3, 0.9%). Techniques were modified to prevent complications especially in bar shaping and fixation, which led to decrease complication rate in later experience (Operation Date 1: 15/51 (29.4%) vs Operation Date 2: 34/284 (12.0%), p=0.004). Grand Canyon type (eccentric long canal type) showed higher complication rate than other types (GC type: 12/30(40%) vs Others: 37/305 (12.1%), p<0.001). Major risk factors are severity of pectus (OR=2.88, p=0.038), Grand Canyon type (OR=2.82, p=0.044), and Op. Date 1 (OR=4.05, p=0.001). Conclusion: Major complications were related to severe eccentric type of pectus configuration (Grand Canyon type) and lack of surgeon's experience (Op. Date 1). Com-plication rate was reduced with accumulation of experience and advancement of surgical techniques. The Nuss procedure can be performed at a low risk of complications with our current technique.

Is Skeletonized Internal Mammary Artery Harvesting better than Pedicled Harvesting in Respect of the Sternal Blood Flow\ulcorner: An Estimation Using Bone Scan (내유동맥의 골격화 채취는 흉골로의 혈류 감소 측면에서 과연 유리한가 \ulcorner: 골주사를 이용한 평가)

  • 손국희;김영삼;김정택;윤용한;김광호;최원식;백완기
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.511-516
    • /
    • 2004
  • Background: One of the theoretical advantages of skeletonized internal mammary artery harvesting in coronary artery bypass surgery is to minimize the interruption of the sternal blood flow inevitably accompanied by internal mammary harvesting. A study using bone scan is designed to determine the effects of internal mammary artery harvesting technique on the sternal blood flow. Material and Method: From April 2002 to March 2003, 27 patients out of 48 patients who underwent the isolated coronary bypass surgery were enrolled into the study. The enrolled patients underwent bone scan in the preoperative period and postoperative period respectively. Bilateral internal mammary artery was used in 8 patients (BIMA group) and single left internal mammary artery in 19 patients (LIMA group). The patients in LIMA group were divided into two groups: LlMA_skel group, in whom left internal mammary artery was harvested in skeletonized fashion (n=12), and LlMA_ped group, in whom left internal mammary artery was harvested in pedicled fashion (n=7). After the bone scan, the region of interest (ROI) was created on the left of the sternum and the mirror image with the same pixel numbers was placed on the right half of the sternum. The mean counts per pixel on the left side of the sternum was compared with those on the right side and expressed as left to right ratio (L/R ratio). Result: In LIMA group, the L/R ratio decreased from 94.6$\pm$4.1% to 87.9$\pm$6.9% (p=0.003) after the operation as compared to BIMA group, in which no change of the L/R ratio was observed. The changed of the L/R ratio in LlMA_skel group and LlMA_ped group were from 95.3$\pm$4.2% to 88.3$\pm$7.7% and from 93.4$\pm$3.9% to 87.4$\pm$5.8% respectively. The % changes in L/R ratio were -7.44 $\pm$7.08 in LIMA_skel group and -6.17$\pm$9.08 in LiMA_ped group, which did not reach the statistical difference. Conclusion: Ipsilateral sternal blood flow is interrupted by internal mammary artery harvesting as evidenced by the decrease in L/R ratio after left internal mammary artery harvesting irrespective of the harvesting techniques. Skeletonized harvesting did not show superiority in respect to sternal blood flow as compared to pedicled harvesting.

Acceptability of Low Intensity Anticoagulation Therapy after Mechanical Heart Valve Replacement (기계식 인공 심장판막 치환술 후 낮은 강도 항응혈 관리의 적정성에 관한 연구)

  • Kim, Jong-Woo;Rhie, Sang-Ho;Kim, Young-Chun;Yang, Jun-Ho;Jang, In-Seok;Choi, Jun-Young
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.193-200
    • /
    • 2009
  • Background: The long-term administration of oral anticoagulant to the patients with a mechanical heart valve prosthesis is mandatory. However, the appropriate intensity of oral anticoagulant therapy to prevent thromboembolic or hemorrhagic complications is still controversial. We tried to apply low intensity anticoagulant therapy for which the International Normalized Ratios ranged between 1.5 and 2.5, and we analyzed the anticoagulation-related long term outcomes. Material and Method: From January 1992 to December 2002, 144 patients who underwent a single cardiac valve replacement were included in the study, and their ages ranged from 15 to 72 years (mean age: $47.4{\pm}15.1$): there were 49 aortic valve replacements (AVR) and 95 mitral valve replacements (AVR). The patients were followed up monthly or bi-monthly at the outpatient clinic with clinical examinations and measuring the prothrombin time to adjust the International Normalized Ratios (INRs) within the low-intensity target range between 1.5 and 2.5. Result: The follow-up period was 835.3 patient-years (mean: $5.9{\pm}3.5$) and the INRs of 7,706 measurements were available for evaluation. The mean INRs of the aortic and the mitral valve replacement groups were significantly different (p<0.01). All the patients' INRs were within the target range in 61.9% of the measurements. The mean INRs $(2.16{\pm}0.23)$ of the patients with atrial fibrillation, which was found in 30.3% of the patients, were definitely higher than those $(2.03{\pm}0.27)$ measured in the patients with regular rhythm (p<0.01). Thromboembolic episodes occurred in 9 patients with an incidence of 1.08%/patient-year. Major bleeding occurred in 2 patients (MVR) with an incidence of 0.24%/patient-year. The patients who displayed better compliance showed a lower incidence of complications (p=0.000). Conclusion: The anticoagulation therapy with a low-intensity target range after MVR or AVR seems to be effective and feasible, and increasing the patients’ compliance should be done for achieving more effective anticoagulation therapy.

The Dynamic and Histologic Changes of Variously Fixed Bovine Pericardiums Specimens after Mechanical Fatigue Stimuli (다양한 고정 처리법을 이용한 소 심낭의 기계적 피로 자극 후 역학적 및 조직학적 변화)

  • Chang, Hyoung-Woo;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Park, Chun-Soo;Kim, Woong-Han;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.148-156
    • /
    • 2009
  • Background: As cardiovascular operations become more complex and sophisticated, there is an increasing need for various bioprostheses for use as components of blood vessels and heart valves. We developed a fatigue stimuli test instrument to objectively evaluate the mechanical durability of a bioprosthesis, and we tested several currently known processing methods for bovine pericardium and we then compared the results. Material and Method: Fresh bovine pericardium was collected at the butcher shop with using aseptic technique, and each piece of pericardium was fixated and/or decellularized by 16 representative methods. We measured the permeability and compliance of the processed bovine pericardium samples, and measured them again after exposure to the fatigue stimuli. All the pieces of pericardium underwent microscopic examinations before and after the fatigue stimuli. Result: A mixture of glutaraldehyde and solvent treatment showed better mechanical durability than did the single glutaraldehyde treatment. High concentration glutaraldehyde treatment showed equal or no worse results than did low concentration glutaraldehyde treatment. After SDS (sodium dodecylsulfate) decellularization, the mechanical property of the bioprosthesis became much worse ($20{\sim}190$ times) and the mechanical durability to the fatigue stimuli was also very poor. Conclusion: We obtained the basic durability data after various fixation methods with using a home-made fatigue test instrument.

Transaortic Mitral Commissuroplasty with a Bentall Procedure or Artic Valve Replacement (대동맥 판막 치환술과 벤탈 수술 환자에서 대동맥 근부를 통한 승모판막 교련 성형술)

  • Kim, Si-Wook;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.727-732
    • /
    • 2007
  • Background: The reciptents of aortic valve replacement or a Bentall operation usually display various degrees of mitral regurgitation. When deciding whether or not to correct the mitral regurgitation, one must consider its severity, underlying causes and operative risk. Recently, the operation method for correcting the concomitant mitral regurgitation has been done through aortic root to reduce the operation time and the cardiac trauma. We report our experiences that transaortic mitral valve commissuroplasty done with aortic valve replacement or a Bentall operation has been a simple, less invasive, effective method in the operative management of mitral valve regurgitation without significant organic changes. Material and Method: Between June 2002 and June 2005, twenty patients under-went mitral valve commissuroplasty via the aortic root with aortic valve replacement (n=14) or a Bentall operation (n=7). The mitral valve regurgitation of the patients didn't exceed a moderate (grade 2) degree and there was no significant organic disease. The preoperative diagnosis of MR was established by TTE and intraoperative TEE, and the patients were followed postoperatively by TTE. The operative technique was a simple anterolateral commissuroplasty of the mitral valve with a single mattress suture via the transaortic annular approach after excision of the aortic valve leaflets. Result: The mean patient age was 56.2 years and 65% (n=13) were male. The preoperative MR was mild (grade 1) in 9 (45%), mild to moderate in 8 (40%), and moderate (grade 2) in 3 (15%) patients. There were no operative mortalities. The MR improved in all patients (p=0.002) and the left ventricular ejection fraction (LV EF) improved in 14 (70%) patients (p=0.005). The mean cross-clamp time for the patients who under- went aortic valve replacement with transaortic mitral repair was $62.1{\pm}13.9 min$ and this was $137.5{\pm}7.2 min$ for the patients who underwent a Bentall operation with transaortic mitral repair. Conclusion: For selected patients without significant mitral organic disease, transaortic mitral valve commissuroplasty combined with aortic valve replacement or a Bentall operation may be a feasible, effective method without adding significant aortic cross clamping time and more cardiotomy.

MICROLEAKAGE OF RESILON: EFFECTS OF SEVERAL SELF-ETCHING PRIMER (Resilon을 이용한 근관충전 시 수종의 치면처리제에 따른 미세누출 평가)

  • O, Jong-Hyeon;Park, Se-Hee;Shin, Hye-Jin;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.133-140
    • /
    • 2008
  • The purpose of this study was to compare the apical micro leakage in root canal filled with Resilon by several self-etching primers and methacrylate-based root canal sealer. Seventy single-rooted human teeth were used in this study. The canals were instrumented by a crown-down manner with Gate-Glidden drills and .04 Taper Profile to ISO #40. The teeth were randomly divided into four experimental groups of 15 teeth each according to root canal filling material and self-etching primers and two control groups (positive and negative) of 5 teeth each as follows: group 1 - gutta percha and $AH26^{(R)}$ sealer: group 2 - Resilon, $RealSeal^{TM}$ primer and $RealSeal^{TM}$ sealer: group 3-Resilon, Clearfil SE $Bond^{(R)}$ primer and $RealSeal^{TM}$ sealer group 4-Resilon, $AdheSe^{(R)}$ primer and $RealSeal^{TM}$ sealer. Apical leakage was measured by a maximum length of linear dye penetration of roots sectioned longitudinally by diamond disk. Statistical analysis was performed using the One-way ANOVA followed by Scheffe's test. There were no statistical differences in the mean apical dye penetration among the groups 2, 3 and 4 of self-etching primers. And group 1, 2 and 3 had also no statistical difference in apical dye penetration. But, there was statistical difference between group 1 and 4 (p < 0.05). The group 1 showed the least dye penetration. According to the results of this study, Resilon with self-etching primer was not sealed root canal better than gutta precha with $AH26^{(R)}$ at sealing root canals. And there was no significant difference in apical leakage among the three self-etching primers.

Outcome of the Modified Norwood Procedure: 7 Years of Experience from a Single Institution (변형된 노우드(Norwood) 수술의 결과: 단일병원의 지난 7년간의 경험)

  • Kim, Hyung-Tae;Sung, Si-Chan;Kim, Si-Ho;Bae, Mi-Ju;Lee, Hyoung-Doo;Park, Ji-Ae;Chang, Yun-Hee
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.364-374
    • /
    • 2010
  • Background: We assessed the early and mid-term results of the modified Norwood procedure for first-stage palliation of hypoplastic left heart syndrome (HLHS) and its variants to identify the risk factors for hospital mortality. Material and Method: Between March, 2003, and December, 2009, 23 patients (18 males and 5 females) with HLHS or variants underwent the modified Norwood procedure. The age at operation ranged from 3 to 60 days (mean, $11.7{\pm}13.2days$) and weight at operation ranged from 2.2 to 4.8 kg (mean, $3.17{\pm}0.52kg$). We used a modified technique that spared the anterior wall of the main pulmonary artery in 20 patients. The sources of pulmonary blood flow were RV-PA conduit in 15 patients (group I) and RMBTS in 8 (group II). Follow-up was completed in 19 patients (19/20, 95%) in our hospital (mean $26.0{\pm}22.8months$). Result: Early death occurred in 3 patients (3/23, 13%), of whom 2 had TAPVC. Fourteen patients underwent subsequent bidirectional cavopulmonary connection (BCPC, stage 2) and seven underwent the Fontan operation (stage 3). Three patients died between stages, 2 before stage 2 and one before stage 3. The estimated 1-year and 5-year survival rates were 78% and 69%, respectively. On multivariate regression analysis, aberrant right subclavian artery (RSCA) and associated total anomalous pulmonary venous connection (TAPVC) were risk factors for hospital mortality after stage 1 Norwood procedure. Conclusion: HLHS and its variants can be palliated by the modified Norwood procedure with low operative mortality. Total anomalous pulmonary venous connection adversely affects the survival after a stage 1 Norwood procedure, and interstage mortality rates need to be improved.