• 제목/요약/키워드: Single Ground

검색결과 1,209건 처리시간 0.032초

GSHP용 수직형 지중열교환기의 열전달 성능에 관한 연구 (A Study on Heat Transfer Performance of Vertical Ground Heat Exchanger of GSHP(Ground Source Heat Pump))

  • 정민호;장기창;나호상;백영진;박성룡;유성연
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2102-2107
    • /
    • 2007
  • GSHP systems are used for air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal and vertical type according to the installation method. Vertical type is usually constructed by placing small diameter high density polyethylene tube in a vertical borehole. Vertical tube sizes range from 20 to 40 mm nominal diameter. Borehole depth range between 100 and 200 m depending on local drilling conditions and available equipment. In this study, to evaluate the performance of single u-tube with bentonite grouting, single u-tube with broken stone grouting and double u-tube bentonite grouting of vertical ground heat exchangers, test sections are buried on the earth and experimental apparatus is installed. Therefore the heat transfer performance and pressure loss of these are estimated.

  • PDF

Ground Plane레이어를 적용한 SMPS 특성분석 (Analysis of SMPS Characteristics applying Ground Plane Layer)

  • 박진홍
    • 한국산학기술학회논문지
    • /
    • 제15권1호
    • /
    • pp.436-440
    • /
    • 2014
  • 본 논문에서는 PCB Plane 레이어가 SMPS에 미치는 영향을 확인하기 위하여 일반적인 단면 PCB와 Plane을 갖는 양면 PCB를 이용한 SMPS의 출력특성을 각각 분석하였다. 그 이후 동일한 레이아웃을 갖는 PCB의 반대 면에 Ground Plane을 설치한 양면PCB를 이용하여 SMPS 기판을 작성하여 단면 PCB SMPS에 적용해서 분석한 모든 부품을 이동 실장한 후 두 SMPS의 출력특성을 전압, 전류, 고주파잡음 측면에서 비교 분석하였다. 그 결과 단면PCB의 SMPS는 100MHz대역의 고주파 잡음이 150mV인 반면, Ground Plane을 설치한 SMPS에서는 50mV로 1/3 저감되는 현상을 확인하였다. 그리고 고주파 잡음 성분 또한 감소됨을 확인하였다.

Parameters affecting the seismic response of buildings under bi-directional excitation

  • Fontara, Ioanna-Kleoniki M.;Kostinakis, Konstantinos G.;Manoukas, Grigorios E.;Athanatopoulou, Asimina M.
    • Structural Engineering and Mechanics
    • /
    • 제53권5호
    • /
    • pp.957-979
    • /
    • 2015
  • The present paper investigates the influence of the orientation of the ground-motion reference axes, the seismic incident angle and the seismic intensity level on the inelastic response of asymmetric reinforced concrete buildings. A single storey asymmetric building is analyzed by nonlinear dynamic analyses under twenty bi-directional ground motions. The analyses are performed for many angles of incidence and four seismic intensity levels. Moreover three different pairs of the horizontal accelerograms corresponding to the input seismic motion are considered: a) the recorded accelerograms, b) the corresponding uncorrelated accelerograms, and c) the completely correlated accelerograms. The nonlinear response is evaluated by the overall structural damage index. The results of this study demonstrate that the inelastic seismic response depends on the orientation of the ground-motion reference axes, since the three individual pairs of accelerograms corresponding to the same ground motion (recorded, uncorrelated and completely correlated) can cause different structural damage level for the same incident angle. Furthermore, the use of the recorded accelerograms as seismic input does not always lead to the critical case of study. It is also shown that there is not a particular seismic incident angle or range of angles that leads to the maximum values of damage index regardless of the seismic intensity level or the ground-motion reference axes.

Feasibility Study of High-Efficiency Ground Heat Exchanger using Double U-tube through a Real-Scale Experiment

  • Bae, Sangmu;Kim, Jaemin;Nam, Yujin
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.33-39
    • /
    • 2017
  • Purpose: The use of renewable energy system is essential for building energy independence and saving energy consumption in the building sector. Among renewable energy technologies, ground source heat pump(GSHP) system is more energy-efficient and environmental-friendly than other heat source systems due to utilize stable ground heat source. However, the GSHP system requires a high initial installation cost and installation space in limited urban area, so it is difficult to have superiority in the market of heat source system. Therefore, it is necessary to develop the installation method of low-cost and improve system performance. This paper aims to evaluate the performance of double u-tube ground heat exchanger(GHX) and verify system feasibility through real-scale experiment. Method: In this study, the real-scale experiment of vertical closed-type GSHP system was conducted using double u-tube GHX and high-efficiency grout. Through the verification experiment, heat source temperature, heat exchange rate(HER) and seasonal performance factor(SPF) were measured according to the long-term operation. In addition, the feasibility analysis was conducted comparing to the single u-tube system. Result: In the results of experiment, average HER was 136.27 W/m and average SPF was 5.41. Furthermore, compared to the single u-tube, the installation cost of the developed system could be reduced about 70% in the same heating load condition.

Investigation of effectiveness of double concave friction pendulum bearings

  • Ates, Sevket
    • Computers and Concrete
    • /
    • 제9권3호
    • /
    • pp.195-213
    • /
    • 2012
  • This paper presents the investigation of the stochastic responses of seismically isolated bridges subjected to spatially varying earthquake ground motions including incoherence, wave-passage and site-response effects. The incoherence effect is examined by considering Harichandran and Vanmarcke coherency model. The effect of the wave-passage is dealt with various wave velocities in the response analysis. Homogeneous firm, medium and soft soil conditions are selected for considering the site-response effect where the bridge supports are constructed. The ground motion is described by filtered white noise and applied to each support points. For seismic isolation of the bridge, single and double concave friction pendulum bearings are used. Due to presence of friction on the concave surfaces of the isolation systems, the equation of motion of is non-linear. The non-linear equation of motion is solved by using equivalent linearization technique of non-linear stochastic analyses. Solutions obtained from the stochastic analyses of non-isolated and isolated bridges to spatially varying earthquake ground motions compared with each other for the special cases of the ground motion model. It is concluded that friction pendulum systems having single and double concave surfaces have important effects on the stochastic responses of bridges to spatially varying earthquake ground motions.

군쇄석다짐말뚝의 지지력 특성에 관한 연구 (A Study on Bearing Capacity Characteristics of Group Crushed-Stone Compaction Piles)

  • 황근배;이민희;신현철;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.705-712
    • /
    • 2005
  • Among soft ground treatment methods with granular soil used in domestic, the sand compaction pile method has been utilized greatly, but, as a result of exhaustion of sand and increase of unit cost, a necessity of an alternative method is suggested. In this study, the static load tests for group crushed-stone compaction piles which were constructed at in-situ site were performed. Pile diameter was 700mm and area of loading plates were changed. The static load tests of single and group piles were performed for area replacement ratio of 20, 30 and 40%. Based on test results, bearing capacity of group crushed-stone compaction pile were estimated. The more both single pile and group pile increase, the more yield bearing capacity tended to increase. Also, the yield bearing capacity of a group pile is about 50% less than the yield bearing capacity of a single pile. If the ground reinforced with the crushed-stone compaction pile is replacement ratio of $20{\sim}40%$, RIYB of both single pile and group pile increases qualitative tendency of linear more than original ground

  • PDF

Variation of the Discharge Characteristics in single-sustainer Driving of an AC PDP

  • Kim, Joong-Kyun;Jung, Hae-Yoon
    • Journal of Information Display
    • /
    • 제11권4호
    • /
    • pp.154-159
    • /
    • 2010
  • Single-sustainer driving is an AC PDP driving scheme to reduce the circuitry by maintaining the sustain electrode at ground level. To date, however, the research on the discharge characteristics in such driving scheme is insufficient. In this study, the panel performance and discharge characteristics of the single-sustainer driving scheme were observed while varying the address electrode condition. In single-sustainer driving, the address electrode is strongly involved in the sustain discharge when the former is maintained at ground level, and the dependence of the luminous efficacy on the sustain voltage is different from that in the conventional driving scheme. The dependence of the luminous efficacy on the sustain voltage appeared similar, however, to that in the conventional driving scheme when the address electrode was floated in single-sustainer driving. In the investigation of the temporal evolution of the sustain discharge using an IICCD camera, it was found that the sustain discharge in single-sustainer driving with a floating address electrode is similar to that in the conventional driving scheme, and the strong plasma formation region was located in the vicinity of the MgO surface, which seems to be related to the lifetime of a PDP with single-sustainer driving. In the investigation of the operation characteristics, the PDP that was operated with a floated address electrode showed a narrower dynamic operation margin, but a longer lifetime was expected.

음향학적 방법에 의한 지표면의 유동 비저항 예측 (Prediction of the Specific flow resistivity of the Ground Surface by Acoustical Method)

  • 황철호;정성수;은희준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 추계학술대회논문집; 한국과학기술회관; 6 Nov. 1997
    • /
    • pp.237-243
    • /
    • 1997
  • Most outdoor sounds go from sources relatively near the ground to receivers near the ground. When either source or receiver are near the ground, interference can occur between the direct sound and that reflected at the ground which travels a slightly longer path. The sound pressure at the receiver is very different depending on the state of ground surface i.e. ground impedance. Ground impedances could be characterized by the value of a single parameter, namely the flow resistivity of the ground surface. This study suggests the measurement method of the flow resistivity using two microphones and predicts the flow resistivities of various ground surfaces.

  • PDF

전위간섭을 기초로 한 병렬 접지봉의 합성접지임피던스의 분석 (An Analysis on Resultant Ground Impedance Based on the Potential Interference Of Parallel Ground Rods)

  • 이복희;성창훈;양순만
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.107-112
    • /
    • 2011
  • Multiple ground rods are commonly used to obtain the low ground impedance, but they will not reduce the ground impedance unless the spacings between the ground rods are sufficient. This paper presents the experimental results of frequency-dependent resultant ground impedance of two ground rods in parallel. The resultant ground impedance of two ground rods in parallel were measured as functions of the spacing and length of ground rods and the frequency of test currents and were discussed based on the potential interferences. As a consequence, the frequency-dependent ground impedance of single ground rod and two combined ground rods give capacitive. It was found that the effect of potential interference on the ground impedance is directly associated with the frequency-dependent ground impedance and is strong in low frequency. Also, in order to reduce the increasing rate of resultant ground impedance of two ground rods due to potential interference to within 10(%), two ground rods in parallel will be placed over one rod length apart.