• Title/Summary/Keyword: Single Contact Spots

Search Result 7, Processing Time 0.018 seconds

Effect of Multiple Contact Spots Simulated by Array of Balls on Contact Resistance (볼군의 다수 접촉점이 접촉저항에 미치는 영향)

  • ;Myshkin,N.K.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.2967-2972
    • /
    • 1994
  • The multiple character of the contact interaction and the collective behavior of elementary microcontacts play a significant role in all the processes occurring in the surface layers, including the failure due to friction and wear. The array of metal spheres compressed between flat plates has been used for simulation of the contact behavior of multiple contact of solids under normal loading. An experimental design has been made providing regular array of the spheres at the same size with different spatial order. Measurement of electrial contact resistance has been made using the equipment providing the adequate accuracy in the range of micro Ohms. The data on electrical contact resistance have been compared with theoretical predictions using the multiple contact model of constriction resistance. The effect of single spots number and array on conductivity of contact has been evaluated.

Analysis of Electrical Contact Resistance Model in Multi-Contact of Tribological Elements (트라이볼로지 기소의 멀티접촉에서 전기접촉저항 모델해석에 관한 연구)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.12 no.4
    • /
    • pp.52-59
    • /
    • 1996
  • The results of the electrical contact conductivity of multi-contact spots accounting the surface roughness and the non-conductive films of different origins such as air, water, cutting oil, and machining oil are presented. The array of metal spheres compressed between two flat plates has been used for simulation of the contact behavior of multiple contact of solids, under normal loading. Measurement of electrical contact resistance has been made using the equipment providing the adequate accuracy in the range of micro Ohms. The data on electrical contact resistance have been compared with theoretical predictions using the multiple contact model of constriction resistance. The effect of single spot number and array on conductivity of contact has been evaluated. The results of the experiments show that the contact resistance are closely related to the number of loading cycles, form of surface roughness, and presence of non-conductive films that reduce the size of the real electrical contact spots.

Direct-contact heat transfer of single droplets in dispersed flow film boiling: Experiment and model assessment

  • Park, Junseok;Kim, Hyungdae
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2464-2476
    • /
    • 2021
  • Direct-contact heat transfer of a single saturated droplet upon colliding with a heated wall in the regime of film boiling was experimentally investigated using high-resolution infrared thermometry technique. This technique provides transient local wall heat flux distributions during the entire collision period. In addition, various physical parameters relevant to the mechanistic modelling of these phenomena can be measured. The obtained results show that when single droplets dynamically collide with a heated surface during film boiling above the Leidenfrost point temperature, typically determined by droplet collision dynamics without considering thermal interactions, small spots of high heat flux due to localized wetting during the collision appear as increasing Wen. A systematic comparison revealed that existing theoretical models do not consider these observed physical phenomena and have lacks in accurately predicting the amount of direct-contact heat transfer. The necessity of developing an improved model to account for the effects of local wetting during the direct-contact heat transfer process is emphasized.

접촉 저항법을 응용한 트라이볼로지 문제점의 해석

  • 김청균
    • Tribology and Lubricants
    • /
    • v.10 no.2
    • /
    • pp.1-4
    • /
    • 1994
  • 금속과 금속이 접합할 때 발생하는 고유 저항값은 접촉소재의 종류, 접촉면의 상태, 접촉조건(하중, 온도, 정적 또는 동적인 접촉 등), 주변환경에 따라서 변한다. 소재가 접촉할 때 발생되는 저항값의 변화특성을 적극적으로 이용한 것이 전기 저항법(Electrical Contact Resistance Method)이다. 접촉 저항법의 특징은 접촉시 발생되는 저항값이 미세하게 변화한다 할지라도 모두 계측이 가능하다는 점이다. 그동안의 연구는 ㅈ로 단일 접촉점(Single Contact Spots) 위주의 단편적인 실험적 연구를 통하여 접촉 저항법에 대한 신뢰도 확보에 노력하였으나, 최근에는 접촉점이 인접한 다른 접촉부위에 미치는 영향, 즉 다수 접촉점군(Multiple Contact Spots and Clusters)의 거동해석에 더욱 큰 연구 비중을 두고 있다. 접촉점군 상호간의 영향에 관한 연구가 많이 진행되기는 하였지만 해석모델의 적절성 여부가 실험적 데이타를 통하여 확인이 아직 안되었기 때문에 기존의 접촉저항 추정식을 직접 사용하기가 어려웠으나 최근에 볼군-원판 모델에 대한 접촉점과 다수의 접촉점군 상호간에 발생될 수 있는 접촉저항 특성을 실험적으로 해석하여 보다 정확한 해석모델이 제시되었다.

The Solar-Type Contact Binary BX Pegasi Revisited

  • Lee, Jae-Woo;Kim, Seung-Lee;Lee, Chung-Uk;Youn, Jae-Hyuck
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.24.2-24.2
    • /
    • 2009
  • We present the results of new CCD photometry for the contact binary BX Peg, made during three successive months beginning on September 2008. As do historical light curves, our observations display an O'Connell effect and the November data by themselves indicate clear evidence for very short-time brightness disturbance. For these variations, model spots are applied separately to the two data set of Group I (Sep.--Oct.) and Group II (Nov.). The former is described by a single cool spot on the secondary photosphere and the latter by a two-spot model with a cool spot on the cool star and a hot one on either star. These are generalized manifestations of the magnetic activity of the binary system. Twenty light-curve timings calculated from Wilson-Devinney code were used for a period study, together with all other minimum epochs. The complex period changes of BX Peg can be sorted into a secular period decrease caused dominantly by angular momentum loss due to magnetic stellar wind braking, a light-travel-time (LTT) effect due to the gravitational effect of a low-mass third companion, and a previously unknown short-term oscillation. This last period modulation could be produced either by a second LTT orbit with a period of about 16 yr due to the existence of a fourth body or by the effect of magnetic activity with a cycle length of about 12 yr.

  • PDF

Influence of twisting angle between fixed contact and movable contact on arc driving force in 3petal spiral type vacuum interrupter (3petal spiral type vacuum interrupter에서 가동접점전극과 고정접점전극간의 마주보는 각도의 변화가 아크구동력에 미치는 영향)

  • Kim, Byoung-Chul;Yun, Jae-Hun;Lee, Seung-Soo;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.480-480
    • /
    • 2008
  • Vacuum circuit breaker(VCB) is now emerging as an alternative of gas circuit breaker(GCB) which uses SF6 gas as insulating material whose dielectric strength is outstanding. But we have to reduce SF6 gas because SF6 gas is one of greenhouse gas and efforts to reduce greenhouse gas are now trend of the world. Therefore, we can say VCB is the optimal alternative of GCB because vacuum is environmentally friendly. The vacuum interrupter is the core part of VCB to interrupt arcing current. There are mainly two methods to extinguish arc. One is radial magnetic field (RMF) method and the other is axial magnetic field (AMF) method. We deals with RMF method in this paper. Compared with AMP, RMF arc quenching method has different principle to extinguish arc. In case of RMF method, pinch effect is much larger than AMF method. Because of pinch effect RMF type contact electrodes have the single large spot which is severly damaged and melted while AMF type contact electrodes have small and multiple spots which are slightly damaged and melted. To prevent contact electrode being damaged and melted from high temperature-arc, RMF method uses Lorentz force to move arc. In this paper we calculated and compared the arc driving force of two cases and we analyzed the force acting on each part of arc by means of commercial finite element method software Maxwell 3D. They have 3petals and we considered two cases. One is the case when fixed(upper) and movable(lower) contacts are in mirror arrangement (Case 1). The other is the case when one of two contacts (movable contact) is revolved at maximum angle as possible as it can be (Case 2). And at each case above, we analyzed arc driving force at two positions, position 1 is the closest to the center of contact and position 2 is near the edge of petal on fixed contact. As a result we could find that Case 2 generated stronger arc driving force than Case 1 at position 1. But at position 2 Case 1 generated stronger arc driving force than Case 2. This simulation method can contribute to optimizing spiral-type electrode designs in a view of arc driving force.

  • PDF

Accessibility Situation of Pedestrian Environment Buildings in College Campus from Manual Wheelchair Users' Perspective and Accessibility Map Development - Focused on a Case of University-C - (자주식 휠체어 사용자 관점의 캠퍼스 보행환경과 건물 접근성 실태 및 접근성 맵 제작 - C대학교 사례를 중심으로 -)

  • So-Hee, Moon;Ga-Ram, Han;Hyun-Jeong, Lee
    • Journal of the Korean housing association
    • /
    • v.28 no.2
    • /
    • pp.23-33
    • /
    • 2017
  • This study was aimed to assess accessibility situation of pedestrian environment of University-C focusing on accessibility of manual wheelchair users and to develop accessibility campus map. During March and April 2016, barrierfree design application situation of pedestrian environment and building entrances were investigated using a structured checklist and a digital distance and slope meter. Major findings are as follow. (1) Except one case, widths of all pedestrian routes (both sidewalk and non-sidewalk routes) exceeded 2 meters. (2) As for sidewalk and driveway contact point condition, there were many spots lacking curb ramp or alterative ramp that are accessible for manual wheelchair users. (3) More than half of non-sidewalk pedestrian routes did not have bollard to separate pedestrian and vehicle flows, and more than 92% of the bollards installed were too close for wheelchair users to pass or too far to prevent vehicle access. (4) More than 59 percent of the building entrances were found impossible for manual wheelchair users to access without any assistance, and one third of the buildings did not have any single accessible entrance. Based on the study findings, campus accessibility map was developed by the researchers and disseminated through university homepage. Using the campus accessibility map, users can plan their accessible paths ahead the trip.