• Title/Summary/Keyword: Single Bed Patient Room

Search Result 6, Processing Time 0.014 seconds

Use of Single Bedrooms versus Multiple Bedrooms: Selection Factors and Comparison of Patient Satisfaction (1인실과 다인실 입원 병상 이용에 관한 병상 선택 요인과 환자 만족도 분석)

  • Lee, Geun-Chan
    • Korea Journal of Hospital Management
    • /
    • v.26 no.3
    • /
    • pp.68-83
    • /
    • 2021
  • Background: It is widely acknowledged that single bedrooms have many potential advantages compared to multiple bedrooms. However, Korea has a reimbursement system that patients have to pay the additional fee if they will use single bedroom or pay-bed (1-3 bedroom). There is little research on patients' bed selection and relationship between patient satisfaction and bed type in the Korean setting. Methods: Using the 2017 Korea Health Panel (KHP) Survey data, we modified bed type by two dichotomous variables: single bedroom vs. multiple bedroom (2+ bedrooms) and pay-bed (1-3 bedroom) vs. reimbursed bed (4+ bedroom). Multivariate logistic regression is performed to determine the factors affecting the patient's choice of room types. Multivariate regression analysis was conducted to examine how hospital room types are affecting patient satisfaction. Results: Single room and pay-bed (1-3 bedroom) use was influenced by patient age (19- years old), male, a person at work, hospitalizing in a clinic, and birth. After controlling variables of the behavioral model of medical utilization, the association between patient satisfaction and use of single bedroom & pay-bed (1-3 bedroom). Cause of hospitalization, major treatment, and recognition of unnecessary care are statistically significant variables on patient satisfaction. Conclusion: Although the single room is about the standard for newly built hospitals in western countries, it remains unclear that single room or pay-bed (1-3 bedroom) has positive effects on patient's outcomes and satisfaction. In this empirical study, the difference in patient satisfaction by bedroom type was not noticeable. In terms of bed management by hospital staff, securing patient credibility in hospital care is an important task. Patients' perception of whether medical staffs have encouraged unnecessary treatment or tests has a significant impact on patient's satisfaction.

A Study on the Area and Clearances around Patient Bed Space in Intensive Care Unit (중환자실 병상주변공간의 면적과 간격에 관한 연구)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.47-55
    • /
    • 2019
  • Purpose: This study tries to propose the dimensions and area related to patient bed and surroundings in ICU considering nurses' observation and medical care. Methods: Literature survey, 11 Case studies, some Interviews with nurses and measuring of medical equipments' dimension in ICU have been mobilized in order to deepen the ICU bed area standards. Results: 0.3m clearance between head wall and patient bed is necessary for emergency cases. The minimum distance at the foot of the bed should not be less than 0.9m for EMR cart and medical tray. The clear floor area of one bed and surroundings in open ward is $10.2m^2(3m{\times}3.4m)$. In a single-bed patient room, the minimum clear floor area is $16.0m^2(4m{\times}4m)$. Considering the control of cross infection in ICU, Single bed patient room is recommended. Implications: The result of this study can be applied to the design of ICU and legislation of ICU standard.

A Study of the Spatial Composition and the Facility Criteria of In-patient Rooms in General Hospitals after MERS 2015 (2015년 메르스 사태 이후 신축된 종합병원 병동부의 공간구성 특징 및 입원실 세부시설기준에 관한 연구)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.2
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: This study is to address the spacial composition of a standard ward and bedroom size for sake of infection control and efficient medical service. Methods: Spacial composition of a standard ward has been proposed by comparative analysis of 5 big hospitals' wards. Bedroom sizes have been explored on the ground of Health care facility regulations from Korea, USA, Australia and Canada. Of course, Literature and field survey have been conducted in order to draw out various bedroom sizes. Results: 16 basic and some other additional spaces have been proposed for the composition of hospital standard ward. Area of Single bedroom is $11.6m^2$, and that of multi-beded room is $7.4m^2$. Bed to bed Clearance is 1.5m, spacing between bedsize and hard wall is 0.9m in 1~2 beded room, 0.75m in 4-beded room. Space clearance between Foot side of bed and curtain is proposed as 0.3m and additional 0.9m is necessary for the circulation. Implications: The result of this study can be applied to the new cons.

Changes of Ward Modules according to the 2017 Revision of Medical Law (2017 의료법 개정에 따른 병실 모듈변화 연구)

  • Lee, Hyun-jin;Ju, Youn-Ock
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • Purpose : As the necessity of reinforcement of infections management in medical facilities after MERS increased, Ministry of Health and Welfare promulgated the enforcement regulations of medical law on February 3, 2017. Its main objective is to improve patients' safety and medical-care quality through the establishment of isolation facilities from infectious diseases and the set-up of standards for In-patient and ICU facilities. The purpose of this study is necessarily to propose a standardized spatial composition model for ward modules by analyzing changing environments of in-patient facilities according to the strengthened medical law. Method: Theoretical studies will be undergone of Evidence-based Designs to improve patients' safety, medical quality, and domestic/overseas in-patient room guidelines. With reference to the status of 24 general hospitals over 500 beds, the spatial compositions of the in-patient rooms and the types of multi/single bed room modules will be analyzed. The directions of future in-patient room module changes through the study of the minimum ward module types and various ward types will be presented. Result: This paper will hopefully provide guidelines for hospitalization rooms that can be applied to the revised rules of medical law enforcement and provide a basis for a comprehensive study of patients' safety and efficient infection control as well.

Minimally Invasive Coronary Artery Bypass without Extracorporeal Circulation - One case report - (심폐바이패스없이 제한적 전흉부개흉술로 시행한 관상동맥우회술 1례)

  • 서필원;김삼현;이상민;김영권;박이태
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1263-1266
    • /
    • 1996
  • We have experienced a case of coronary artery bypass surgery without extracorporeal circulation through limited anterior thoracotomy. The lesion was a single vessel disease involving the take off of the left anterior descending artery(LAD) which showed tubular lesion with irregular contour and eccentric stenosis of more than 95% luminal narrowing. Percutaneous transluminal coronary angioplasty(PTCA) seemed to have moderate success rate and moderate complication rate. A segment of left internal mammary artery(LIMA) from the second rib down to the sixth rib was harvested through the bed of resected fourth costal cartilage. Anastomosis between LIMA and LAD was performed under beating condition. The patient was extubated in the operation room and showed excellent postoperative course without complications. The coronary angiography on the postoperative 7th day revealed good patency at the anastomosis site.

  • PDF

Fontan Operation in a Case of Single Functional Pulmonary Artery (심한 좌폐동맥 형성부전을 동반한 단심실 환아의 폰탄 수술 증례)

  • Kim Joon Bum;Park Jeong-Jun;Park In Sook;Seo Dong Man
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.308-311
    • /
    • 2005
  • The status of pulmonary circulation is regarded with utmost importance for the successful Fontan operation. The absence of unilateral pulmonary artery leads to decreased pulmonary vascular bed and elevated pulmonary vascular resistance which are the risk factors for Fontan operation. A 9-year-8-month-old female patient diagnosed as tricuspid atresia, pulmonary atresia with absent left pulmonary artery flow, received extracardiac conduit Fontan operation using 18 mm Gore-Tex graft. She was discharged on twenty sixth postoperative day with arterial $O_2$ saturation of $70\%$ on room air. On last follow up at 14 months after the operation, she was clinically well with $O_2$ saturation of $91\%$.