• Title/Summary/Keyword: Sine Filter

Search Result 57, Processing Time 0.028 seconds

Microvibration analysis of a cantilever configured reaction wheel assembly

  • Zhang, Zhe;Aglietti, Guglielmo S.;Ren, Weijia;Addari, Daniele
    • Advances in aircraft and spacecraft science
    • /
    • v.1 no.4
    • /
    • pp.379-398
    • /
    • 2014
  • This article discusses the microvibration analysis of a cantilever configured reaction wheel assembly. Disturbances induced by the reaction wheel assembly were measured using a previously designed platform. Modelling strategies for the effect of damping are presented. Sine-sweep tests are performed and a method is developed to model harmonic excitations based on the corresponding test results. The often ignored broadband noise is modelled by removing spikes identified in the raw signal including a method of identifying spikes from energy variation and band-stop filter design. The validation of the reaction wheel disturbance model with full excitations (harmonics and broadband noise) is presented and flaws due to missing broadband noise in conventional reaction wheel assembly microvibration analysis are discussed.

Highly Efficient Video Codec for Entertainment-Quality

  • Jeong, Se-Yoon;Lim, Sung-Chang;Lee, Ha-Hyun;Kim, Jong-Ho;Choi, Jin-Soo;Choi, Hae-Chul
    • ETRI Journal
    • /
    • v.33 no.2
    • /
    • pp.145-154
    • /
    • 2011
  • We present a novel video codec for supporting entertainment-quality video. It has new coding tools such as an intra prediction with offset, integer sine transform, and enhanced block-based adaptive loop filter. These tools are used adaptively in the processing of intra prediction, transform, and loop filtering. In our experiments, the proposed codec achieved an average reduction of 13.35% in BD-rate relative to H.264/AVC for 720p sequences.

Boost Converter for High Performance Operating of Fuel Cell System (연료전지 시스템의 고효율운전을 위한 6상 BOOST CONVERTER)

  • Park, S.S.;Yoon, H.J.;Goo, T.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.867-869
    • /
    • 1993
  • In generally Boost Converter is used for Fuel Cell System. Because the output voltage of fuel cell is too small and greatly depends on the load condition, Boost Converter are required to boost and regulate the Fuel Cell voltage for per conversion efficiency. In this Paper, 6-phase Boost Converter is used to boost the Fuel Cell Voltage and regulate the output voltage. Multi phase converter hag some advantages such as low ripple and filter sine. About the Peak Current Control and compare of the Ripple Current of Boost Converter, we have studied.

  • PDF

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

Leakage Detection of Water Distribution System using Adaptive Kalman Filter (적응 칼만필터를 이용한 상수관망의 누수감시 기법)

  • Kim, Seong-Won;Choi, Doo Yong;Bae, Cheol-Ho;Kim, Juhwan
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.10
    • /
    • pp.969-976
    • /
    • 2013
  • Leakage in water distribution system causes social and economic losses by direct water loss into the ground, and additional energy demand for water supply. This research suggests a leak detection model of using adaptive Kalman filtering on real-time data of pipe flow. The proposed model takes into account hourly and daily variations of water demand. In addition, the model's prediction accuracy is improved by automatically calibrating the covariance of noise through innovation sequence. The adaptive Kalman filtering shows more accurate result than the existing Kalman method for virtual sine flow data. Then, the model is applied to data from two real district metered area in JE city. It is expected that the proposed model can be an effective tool for operating water supply system through detecting burst leakage and abnormal water usage.

An Adaptive Equalization of Amplitude Chrominance Distortion by using the Variable Step-size Technique

  • Chutchavong, Vanvisa;Janchitrapongvej, Kanok;Benjangkaprasert, Chawalit;Sangaroon, Ornlarp
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.2065-2069
    • /
    • 2004
  • This paper presents an adaptive equalizer using finite impulse response (FIR) filter and least-mean square (LMS) algorithm. Herein, the variable step-size technique (VSLMS) for compensating the amplitude of chrominance signal is utilized. The proposed equalizer can be enhanced and compressed the chrominance signal at color subcarrier. The LMS algorithm employed in simplicity structure but gives slow convergence speed. Thus, the variable step-size is very attractive algorithm due to its computational efficiencies and the speed of convergence is improved. In addition, experimental results are carried out by using the modulated 20T sine squared test signal. It is shown here that the adaptive equalizer can be equalized the amplitude chrominance distortion in color television transmission without relative delay distortion.

  • PDF

Digital Image Watermarking Schemes Based on GCST and SVD (GCST-SVD 기반 디지털 영상 워터마킹 방법)

  • Lee, Juck-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.3
    • /
    • pp.154-161
    • /
    • 2013
  • In this paper, Gabor cosine and sine transform considered as human visual filter is applied to watermarking methods for digital images. Four algorithms by using singular values or principal components of SVD in the frequency domain are proposed for watermark embedding and extraction. Two dimensional image is used as an embedded watermark. To measure the similarity between the embedded watermark image and the extracted one, a normalized correlation value is computed for the comparison of the four proposed methods with various attacks. Extracted watermark images are also provided for visual inspection. The proposed GCST-SVD method which embeds a watermark image into the lowest vertical or horizontal ac frequency band can provide useful watermarking algorithm with high correlation values and visual watermark features from experimental results for various attacks.

A New Random SPWM Technique for AC-AC Converter-Based WECS

  • Singh, Navdeep;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.939-950
    • /
    • 2015
  • A single-stage AC-AC converter has been designed for a wind energy conversion system (WECS) that eliminates multistage operation and DC-link filter elements, thus resolving size, weight, and reliability issues. A simple switching strategy is used to control the switches that changes the variable-frequency AC output of an electrical generator to a constant-frequency supply to feed into a distributed electrical load/grid. In addition, a modified random sinusoidal pulse width modulation (RSPWM) technique has been developed for the designed converter to make the overall system more efficient by increasing generating power capacity and reducing the effects of inter-harmonics and sub-harmonics generated in the WECS. The technique uses carrier and reference waves of variable switching frequency to calculate the firing angles of the switches of the converter so that the three-phase output voltage of the converter is very close to a sine wave with reduced THD. A comparison of the performance of the proposed RSPWM technique with the conventional SPWM demonstrated that the power generated by a turbine in the proposed approximately increased by 5% to 10% and THD reduces by 40% both in voltage and current with respect to conventional SPWM.

Evaluation of applicability of Hampel Filter to outlier check for river water level data (하천수위 자료 이상치 점검에 대한 Hampel 필터의 적용성 평가)

  • Park, Heeseong;Kim, Hyoung Seop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.352-352
    • /
    • 2022
  • 수위자료는 기초 수문자료의 하나로서 자료 수집시 이에 대한 품질관리가 반드시 필요하다. 이 과정에서 이상치 여부를 점검하여 이상치로 확인된 경우 소거하거나 수정하는 등의 처리를 해야 한다. 수위자료의 이상치 점검에는 다양한 방법이 있지만 아직 일반화된 방법은 없다. 이에 다양한 방법에 대한 적용가능성을 평가해 볼 필요가 있다. Hampel 필터는 신호처리 시 신호의 이상치를 찾아 보완하려고 개발된 필터이다. 시계열자료에서 이상치를 감지하는 고전적인 접근 방법은 이동평균과 이동표준편차를 이용하는 것이지만 고전적인 이동평균과 이동표준편차는 이상치의 영향을 받는다. 이에 따라 이상치의 추정이 어렵게 되는 경우가 있다. 이에 반하여 Hampel 필터는 이동평균 및 이동표준편차 대신 중앙값과 중앙값 절대편차(Median Absolute Deviation; MAD)를 이용함으로써 더 나은 결과를 얻을 수 있다. Hampel 필터는 신호처리용으로 개발되었기 때문에 부드러운 Sine 곡선에 적합할 것으로 보이며, 이미 하천수위 변화보다는 부드러운 변화를 보이는 저수지수위의 이상치를 점검하기 위해 사용되고 있다. 하지만 변화가 급격하고 첨두가 발생하는 하천의 수위에 대해서도 적용할 수 있는지에 대해서는 평가가 필요하다. 이에 본 연구에서는 신호처리에 사용되는 Hampel 필터를 이용하여 수위자료의 이상치 점검에 적용하고 과거 자료에 기록된 실제 이상치 자료와 비교하여 그 성능을 평가해 보았다.

  • PDF

Simulation of the Blood Pressure Estimation Using the Artery Compliance Model and Pulsation Waveform Model

  • Jeon, Ahyoung;Ro, Junghoon;Kim, Jaehyung;Baik, Seongwan;Jeon, Gyerok
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.38-43
    • /
    • 2013
  • In this study, the artery's compliance model and the pulsation waveform model was proposed to estimate blood pressure without applying HPF (High Pass Filter) on signal measured by the oscillometric method. The method proposed in the study considered two ways of estimating blood pressure. The first method of estimating blood pressure is by comparing and analyzing changes in pulsation waveform's dicrotic notch region during each cardiac period. The second method is by comparing and analyzing morphological changes in the pulsation waveform during each cardiac period, which occur in response to the change in pressure applied on the cuff. To implement these methods, we proposed the compliance model and the pulsation waveform model of the artery based on hemodynamic theory, and then conducted various simulations. The artery model presented in this study only took artery's compliance into account. Then, a pulsation waveform model was suggested, which uses characteristic changes in the pulsation waveform to estimate blood pressure. In addition, characteristic changes were observed in arterial volume by applying artery's pulsation waveform to the compliance model. The pulsation waveform model was suggested to estimate blood pressure using characteristic changes of the pulsation waveform in the arteries. This model was composed of the sum of sine waves and a Fourier's series in combination form up to 10th harmonics components of the sinusoidal waveform. Then characteristic of arterial volume change was observed by inputting pulsation waveform into the compliance model. The characteristic changes were also observed in the pulsation waveform by mapping the arterial volume change in accordance with applied cuff's pressure change to the pulsation waveform's change according to applied pressure changes by cuff. The systolic and diastolic blood pressures were estimated by applying positional change of pulsation waveform's dicrotic notch region.