• Title/Summary/Keyword: Simultaneous Measurements

Search Result 265, Processing Time 0.027 seconds

Study of Simultaneous Counting of Thyroid Uptake with Quantitative Analysis of Thyroid Scans (갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구)

  • Jung-Soo Kim;Geun-Woo Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.401-408
    • /
    • 2023
  • Thyroid uptake measurements can be subject to measurement errors due to the scoping and positioning of the thyroid gland. To compensate for these limitations, the clinical utility of the thyroid simultaneous counting method as an alternative to thyroid uptake measurement was analyzed and evaluated experimentally through quantitative analysis of images acquired after thyroid scanning. Experimental data were obtained using a Gamma camera (GE infinia), a thyroid uptake system (KOROID 1), and a thyroid neck phantom. Based on the thyroid uptake rate of 1-5% according to the protocol of thyroid scan test (99mTcO4 - , 370 MBq) in normal results, 99mTcO4 - was set in the range of 3.7-18.5 MBq (Matrix: 256×256, Scan time: 1 min, collimator: pin hole, phantom-collimator distances: 7 cm). The acquired images were corrected for the attenuation of isotopes due to the set-up time and half-life by applying the Auto Region of interest (ROI) drawing system, and the significance of the experimental results was evaluated by Multiple linear regression analysis (SPSS, ver. 22, IBM). The thyroid uptake rate showed a significant correlation between the dose and the measured counts when using the thyroid uptake system equipment. Meanwhile, the quantitative analysis counts of phantom images using Gamma camera also showed a significant correlation. Thus confirmed that the correlation between these two experiments was statistically significant (P<0.05). The simultaneous counting protocol, which indirectly measures thyroid uptake from thyroid scans, is likely to be clinically relevant if complemented by additional studies with different variables in patients with thyroid disease.

Accuracy of three-dimensional cephalograms generated using a biplanar imaging system

  • Park, Ha-Yeon;Lee, Jae-Seo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.48 no.5
    • /
    • pp.292-303
    • /
    • 2018
  • Objective: Biplanar imaging systems allow for simultaneous acquisition of lateral and frontal cephalograms. The purpose of this study was to compare measurements recorded on three-dimensional (3D) cephalograms constructed from two-dimensional conventional radiographs and biplanar radiographs generated using a new biplanar imaging system with those recorded on cone-beam computed tomography (CBCT)-generated cephalograms in order to evaluate the accuracy of the 3D cephalograms generated using the biplanar imaging system. Methods: Three sets of lateral and frontal radiographs of 15 human dry skulls with prominent facial asymmetry were obtained using conventional radiography, the biplanar imaging system, and CBCT. To minimize errors in the construction of 3D cephalograms, fiducial markers were attached to anatomical landmarks prior to the acquisition of radiographs. Using the 3D $Ceph^{TM}$ program, 3D cephalograms were constructed from the images obtained using the biplanar imaging system (3D $ceph_{biplanar}$), conventional radiography (3D $ceph_{conv}$), and CBCT (3D $ceph_{cbct}$). A total of 34 measurements were obtained compared among the three image sets using paired t-tests and Bland-Altman plotting. Results: There were no statistically significant differences between the 3D $ceph_{biplanar}$ and 3D $ceph_{cbct}$ measurements. In addition, with the exception of one measurement, there were no significant differences between the 3D $ceph_{cbct}$ and 3D $ceph_{conv}$ measurements. However, the values obtained from 3D $ceph_{conv}$ showed larger deviations than those obtained from 3D $ceph_{biplanar}$. Conclusions: The results of this study suggest that the new biplanar imaging system enables the construction of accurate 3D cephalograms and could be a useful alternative to conventional radiography.

Correcting Errors Associated with Blood Urea Measurements Employing Nonaction-Doped Ammonium-Selective Electrodes (암모늄선택성 전극을 이용한 요소센서의 오차보정에 관한 연구)

  • Kim, Young No;Shin, Doo Soon;Kim, Chang Yong;Shin, Jae Ho;Nam, Hakhyun;Cha, Geun Sig
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.12
    • /
    • pp.925-931
    • /
    • 1995
  • Urea sensors, prepared by immobilizing urease on ammonium-selective membrane electrodes doped with nonactin, can show interference from several ionic species present in blood samples (e.g., sodium, potassium, and endogenous ammonium ions). This interference problem does not arise from the immobilized biocatalytic reaction but rather from the innate response of the base transducer to ionic species in the sample. In this work, the use of calibrators containing adequate amounts of ionic species is examined to reduce errors caused by endogenous ionic interferences with blood urea measurements. Simultaneous measurements of the interfering species with additional sensors and subsequent substractions of these values from the urea electrode signals are also described. It is shown that the use of a potassium-selective electrode with an adequate calibrator system greatly enhances the accuracy of the urea sensor measurements.

  • PDF

Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination (지반 오염도 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가)

  • Oh, Myoung-Hak;Kim, Yong-Sung;Park, Jun-Boum
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.7
    • /
    • pp.45-54
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for in-situ delineation of subsurface contamination. While the resistivity measurement has a potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements. This study is focused on verifying the applicability of resistivity and capacitance measurements of CPT module to provide information on subsurface contaminated by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination. Electrical measurements of the CPT module showed high applicability to be used in detecting saturated soils contaminated by heavy metal and diesel plume floating above the groundwater table.

Structural damage identification with output-only measurements using modified Jaya algorithm and Tikhonov regularization method

  • Guangcai Zhang;Chunfeng Wan;Liyu Xie;Songtao Xue
    • Smart Structures and Systems
    • /
    • v.31 no.3
    • /
    • pp.229-245
    • /
    • 2023
  • The absence of excitation measurements may pose a big challenge in the application of structural damage identification owing to the fact that substantial effort is needed to reconstruct or identify unknown input force. To address this issue, in this paper, an iterative strategy, a synergy of Tikhonov regularization method for force identification and modified Jaya algorithm (M-Jaya) for stiffness parameter identification, is developed for damage identification with partial output-only responses. On the one hand, the probabilistic clustering learning technique and nonlinear updating equation are introduced to improve the performance of standard Jaya algorithm. On the other hand, to deal with the difficulty of selection the appropriate regularization parameters in traditional Tikhonov regularization, an improved L-curve method based on B-spline interpolation function is presented. The applicability and effectiveness of the iterative strategy for simultaneous identification of structural damages and unknown input excitation is validated by numerical simulation on a 21-bar truss structure subjected to ambient excitation under noise free and contaminated measurements cases, as well as a series of experimental tests on a five-floor steel frame structure excited by sinusoidal force. The results from these numerical and experimental studies demonstrate that the proposed identification strategy can accurately and effectively identify damage locations and extents without the requirement of force measurements. The proposed M-Jaya algorithm provides more satisfactory performance than genetic algorithm, Gaussian bare-bones artificial bee colony and Jaya algorithm.

Measurements of Peroxyacetyl Nitrates at an Urban and a Rural Site in Korea (도시지역과 청정지역에서의 대기 중 PAN(PeroxyAcetyl Nitrate) 측정)

  • 김세웅;이강웅;김경렬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.157-167
    • /
    • 2001
  • Although PAN has ong been considered to belong to one of the most characteristic photooxidants, its concentra-tions have rarely been measured in a systematic manner in Korea. The first in-situ Measurements of PAN were made in concert with simultaneous analysis of NO, NO$_2$, $O_3$ and UV-Visible radiation intensity from Seoul and dong-Hae during Spring and early Summer of 1999. The aim of our study was to evaluate the behavior of photo-chemical species in a highly polluted urban air and a relative clean one. PAN were determined using a semi-auto-mated gas chromatograph equipped with an electron captured detection system. Calibration of the PAN was done by synthesizing liquid standards using a strong acid nitration of the corresponding peracid. The PAN concentra-tions were found in the range of a few ppbv in the urban air ad persistently less than a ppbv in the clean rural airs. Diurnal variations of PAN and $O_3$ were also observed consistently during the experiment with maxima occurring during the late daylight hours. While the positive dependency of $O_3$ production and PAN concentrations were ob-served in most occasion, the dependency became deviated significantly under changes in air masses.

  • PDF

Studies on the Preparation for the Simultaneous Removal of NO and $SO_2$ from Stationary Sources I.Surface properties and reactivity of $V_2O_5-MoO_3/TiO_2$ catalysts (고정원에서 배출되는 $NO_x/SO_x$의 동시제거를 위한 SCR 촉매의 제조법에 관한 연구: I. $V_2O_5-MoO_3/TiO_2$ 촉매들의 표면특성과 반응성)

  • 구미화;정석진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.58-67
    • /
    • 1992
  • For removing $NO_x$ and $SO_x$ from the flue gases emitted from stationary sources, $V_2O_5-MoO_3/TiO_2$ catalysts were prepared by the conventional impregnation method (aqueous solution) and a sort of surface fixation method(nonaqueous solution) as reported excellent reproducibility catalysts. And these catalysts observed their catalytic activities as well as their surface properties. V-Mo-O oxide, prepared from nonaqueous solution of $VOCl_3$ and $Mo(CO)_6$ and aqeous solution method, was supported as amorphous state by XRD and SEM measurements. The infrared spectra of fresh and used catalysts showed that in used catalysts, V=O bands decreased and new bands of vanadium oxysulfate bands were very sensitive. So the catalysts prepared from nonaqueous solution may bring about the high activity. Results from catalytic activity measurements at 350$^\circ$C, in the presence of $SO_2, NO$ conversion was more increased than in absence of $SO_2$. As the $MoO_3$ was added to $V_2O_5/TiO_2 system, SO_2$ conversion increased. It found that from the results, $V_2O-5-MoO_3/TiO_2$ catalysts prepared from an nonaqueous solution may bring about the high activity for both the reaction of NO and $SO_2$ removal.

  • PDF

A new method for in line electrokinetic characterization of cakes

  • Lanteri, Yannick;Ballout, Wael;Fievet, Patrick;Deon, Sebastien;Szymczyk, Anthony;Sauvade, Patrick
    • Membrane and Water Treatment
    • /
    • v.4 no.3
    • /
    • pp.157-174
    • /
    • 2013
  • The present study is devoted to the validation of a new method for in line electrokinetic characterisation of deposits on membrane surfaces. This method is based upon simultaneous measurements of transversal streaming potential and permeates flux at constant pressure before and during the deposit formation. Dead-end filtration experiments were conducted with negative flat membranes forming a narrow slit channel, negative hollow fiber membranes and mono-dispersed suspensions of (negatively charged) polystyrene latex and (positively charged) melamine particles at various concentrations. It was observed that the overall streaming potential coefficient increased in absolute value with the deposited latex quantity, whereas it decreased and changed of sign during the filtration of melamine suspensions. By considering a resistance-in-series model, the streaming potential coefficient of the single deposit ($SP_d$) was deduced from the electrokinetic and hydraulic measurements. The independence of $SP_d$ with respect to growth kinetics validates the measurement method and the reliability of the proposed procedure for calculating $SP_d$. It was found that $SP_d$ levelled off much more quickly when filtration was performed through the slit channel. This different behaviour could result from a non-uniform distribution of the deposit thickness along the membrane given that the position of measuring electrodes is different between the two cells.

Experimental investigation of the large amplitude vibrations of a thin-walled column under self-weight

  • Goncalves, Paulo B.;Jurjo, Daniel Leonardo B.R.;Magluta, Carlos;Roitman, Ney
    • Structural Engineering and Mechanics
    • /
    • v.46 no.6
    • /
    • pp.869-886
    • /
    • 2013
  • This work presents an experimental methodology specially developed for the nonlinear large-amplitude free vibration analysis of a clamped-free thin-walled metal column under self-weight. The main contribution of this paper is related to the developed experimental methodology which is based on a remote sensing technique using a computer vision system that integrates, on-line, the digital image acquisition and its treatment through special image processing routines. The main importance of this methodology is that it performs large deflections measurements without making contact with the structure and thus, not introducing undesirable changes in its behavior, for instance, appreciable changes in mass and stiffness properties. This structure presents, in most cases, highly non-linear responses, which cannot be reproduced by conventional finite-element softwares due, mainly, to the simultaneous influence of geometric and inertial non-linearities. To capture the non-linearities associated with large amplitude vibration and be able to describe the buckling process, the structure is discretized as a sequence of jointed coupled elastic pendulums. The obtained numerical results are favorably compared with the experimental ones, in the pre- and post-buckling regimes.

The 2D Measurement of Soot Diameter and Number Density in a Diesel Engine Using Laser Induced Methods

  • Lee, Myung-Jun;Yeom, Jung-Kuk;Ha, Jong-Yul;Chung, Sung-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.9
    • /
    • pp.1311-1318
    • /
    • 2001
  • It is necessary to diagnose accurately the characteristics of soot formation and oxidation in a diesel engine. Whereas past measurement techniques for soot concentration give limited information for soot, laser-based two-dimensional imaging diagnostics have a potential to provide temporally and spatially superior resolved measurements of the soot distribution. The technique using laser sheet beam has been applied to an optically accessible diesel engine for the quantitative measurement of soot. The results provided the information for reduction of soot from the diesel engine. Both LIS (Laser Induced Scattering) and LII (Laser Induced Incandescence) techniques were used simultaneously in this study. The images of LIS and LII showed the quantitative distribution of the soot concentration in the diesel engine. In this study, several results were obtained by the simultaneous measurements of LIS and LII technique. The diameter and number density of soot in combustion chamber of the test engine were obtained from ATDC 20 degree to 110 degree. The soot diameter increased about 37% between ATDC 20 degree and 110 degree. The number density of soot, however, decreased significantly between ATDC 40 degree and 70 degree.

  • PDF