• Title/Summary/Keyword: Simultaneous Absorption

Search Result 124, Processing Time 0.025 seconds

A Study on the Properties of Converter Slag Modified by Addition of Waste Foundry Sand (폐주물사를 첨가한 전로슬랙의 개질특성에 관한 연구)

  • 김영환;김종학;고인용
    • Resources Recycling
    • /
    • v.8 no.1
    • /
    • pp.44-51
    • /
    • 1999
  • Converter slag was reduced and modified by the simultaneous addition of carbon and waste foundry sand as a $SiO_2$ source. The basic properties such as phase distribution, composition, specific density, hardness. absorption of water and compressive strength of modified slags were measured. The Iron recovery was significantly affected by the basicity of slag. The properties of slow cooled-modified slags of basicity 1.34 arc very similar to the natural aggregates.

  • PDF

Determination of Pd(II) and Pt(II) Metal Cyano Complexes Using Capillary Electrophoresis

  • Lee, Hue-Jin;Lee, Sang-Ho;Chung, Koo-Soon;Lee, Kwang-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.11
    • /
    • pp.945-949
    • /
    • 1994
  • Mixtures of cyano complexes of palladium(II) and platinum(II) were separated by capillary electrophoresis using a fused silica capillary as a separation column and 30 mM phosphate buffer (pH 7) containing 15 wt. % acetonitrile as a running buffer. By virtue of the high ionic mobilities of the negatively charged cyano complexes of Pd(II) and Pt(II), they were separated using a cathodic injection and anodic detection scheme. The metal complexes eluted through the capillary were detected by direct UV absorption at 214 nm. A linear relationship between peak area and concentration was obtained for both ions and the detection limit was lower than $10^{-14}$ mole. The proposed method was applied to real sample, e.g., anode slime obtained from an electrolytic copper refinary, as a method for the simultaneous determination of palladium and platinum.

Simultaneous Improvement of Formaldehyde Emission and Adhesion of Medium-Density Fiberboard Bonded with Low-Molar Ratio Urea-Formaldehyde Resins Modified with Nanoclay

  • WIBOWO, Eko Setio;LUBIS, Muhammad Adly Rahandi;PARK, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.453-461
    • /
    • 2021
  • In wood-based composite panels, low-molar ratio (LMR) urea-formaldehyde (UF) resins usually result in reduced formaldehyde emission (FE) at the expense of poor adhesion. However, the FE and adhesion of medium-density fiberboard (MDF) bonded with LMR UF resins were both improved in this study. The modified LMR UF resins with transition metal ion-modified bentonite (TMI-BNT) nanoclay simultaneously improved the FE and adhesion of MDF panels. The modified LMR UF resins with 5% TMI-BNT resulted in a 37.1% FE reduction and 102.6% increase in the internal bonding (IB) strength of MDF panels. Furthermore, thickness swelling and water absorption also significantly decreased to 13.0% and 24.9%, respectively. These results imply that TMI-BNT modification of LMR UF resins could enhance the formation of a three-dimensional network rather than crystalline domains, resulting in improved cohesion.

Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs (바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가)

  • Cha, Sangwon;Oh, Eunha;Oh, Selim;Han, Sang Beom;Im, Hosub
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.64-77
    • /
    • 2021
  • Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 μL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R2) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson's correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson's correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.

Optimal Operation Condition of Spray Drying Sorber for Simultaneous Removal of Acidic and Organic Gaseous Pollutants (산성 및 유기성 가스의 동시제거를 위한 준건식 세정시스템의 적정 운전 조건)

  • 백경렬;구자공
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.59-64
    • /
    • 2001
  • The effect of major operating parameters in spray drying sorber(=SDS) for automatic control for the simultaneous removal of acidic and organic gaseous pollutants from solid waste incinerator was performed. The field experiment was carried out in pilot scale test for the quantification of major operating parameters of hydrophilic and the hydrophobic pollutants. The removal efficiencies of $SO_2$and HCI in the 5wt% slurry condition were being increased with the increase of the stoichiometric ration which is the molecular ratio of lime to the pollutant concentration, and with the decrease of inflow flue gas temperature in the pilot SDS reactor. The removal efficiency along the height of spray drying sorber was closely related to the temperature profile, and more than 90% of total removal efficiency was achieved in an absorption region. For the removal of acidic gas the optimum operating condition considering the economics and a stable operation is the 5wt% of slurry concentration, 1.2 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. For the organic gases of benzene and toluene the removal efficiencies were 20-60% which is much lower than that of acidic gas. The best removal efficiency was obtained at 1.5 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. The organic\`s removal efficiency along the height of spray drying sorber was quite different from that of acidic gas, that is, more than 60% of the total removal efficiency for benzene and 90% of the total removal for toluene were achieved in the dried adsorption region, which was formed at the lower or exit part of the reactor.

  • PDF

A Study on the Simultaneous Analysis of Fat-Soluble Vitamins in Food Stuffs and Vitamin Products by High Performance Liquid Chromatography (고성능 액체 크로마토그래피에 의한 식품 및 비타민 제제중의 지용성 비타민의 동시 분석에 관한 연구)

  • Poongzag Kim;Chong-Hyeak Kim
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.46-54
    • /
    • 1989
  • The extraction method and quantitative analysis for the fat-soluble vitamins present in food stuffs and vitamin products have been investigated. The simultaneous separation and analysis of the vitamins by reverse phase high performance liquid chromatographic method was conducted using an isocratic elution with methanol : water (95 : 5) eluent on a Novapak $C_{18}$ column. The detection of vitamins was achieved by a variable wavelength UV detector. To improve the detection sensitivity detection wavelengths were set at the highest absorption bands such as 330, 265, 285, and 290nm for the respective vitamins. The analysis for the fat-soluble vitamins was finished within 40 minutes. Alkaline hydrolysis and enzymatic hydrolysis were investigated for the sample preparation; and liquid-liquid extraction and liquid-solid extraction were attempted for the extraction of vitamins. Both hydrolysis methods were turned out to be appropriate for the analysis for vitamins A, D, and E, while for the analysis of vitamin K the enzymatic hydrolysis method demonstrated better results. Diethyl ether, pentane, and n-hexane were found to give higher recovery for the liquid-liquid extraction and silica cartridge for the liquid-solid extraction.

  • PDF

Hydrophobic Cyclodextrin Derivatives as a Sustained Release Carrier of Azidothymidine (아지도싸이미딘의 지속성방출형담체로서의 소수성시클로덱스트린유도체)

  • Seo, Bo-Youn;Park, Gee-Bae;Lee, Kwang-Pyo
    • Journal of Pharmaceutical Investigation
    • /
    • v.26 no.2
    • /
    • pp.71-82
    • /
    • 1996
  • This study has been undertaken to evaluate hydrophobic cyclodextrin(CD) derivatives as a sustained release carrier of azidothymidine(AZT), AZT, which has potent activity against AIDS and AIDS-related complex as thymidine analogue, has been reported that it has significant toxicity and short half life. Therefore, it is necessary to design sustained release oral dosage form to avoid undesirable side effects attributable to an excessive plasma concentration and to reduce the frequency of administration of AZT. Inclusion complexes of AZT with $acetyl-{\beta}-cyclodextrin\;(AC{\beta}CD)$ and $triacetyl-{\beta}-cyclodextrin(TA{\beta}CD)$ were prepared by solvent evaporation method. Interactions of AZT with CD were investigated by Differential Scanning Calorimetry(DSC) and Infrared Spectrophotometry(IR). The decreasing order of water solubilities of AZT and AZT-CD inclusion complexes were as follows; $AZT\;(27.873{\pm}0.015,mg/ml)\;>\;AZT-AC{\beta}CD\;(3.377{\pm}0.003)\;>\;AZT-TA{\beta}CD\;(2.528{\pm}0.001)$. Partition coefficients of $AZT-AC{\beta}CD\;and;\AZT-TA{\beta}CD$ inclusion complexes were increased by 1.27-fold, 1.54-fold in pH 1.2 and 1.32-fold, 1.47-fold in pH 6.8 in comparison with that of AZT. The mean dissolution time (MDT, min) which represents the rapidity of dissolution rate of AZT, $AZT-AC{\beta}CD,\;AZT-TA{\beta}CD$ were 5.12, 14.02 and 19.38 min in pH 1.2 and 2.52, 15.19 and 18.19 min in pH 6.8. AZT was very rapidly and completely dissolved in pH 1.2 and pH 6.8 within 5 minutes. But AZT-CD inclusion complexes showed the sustained release pattern in comparison with AZT alone. The simultaneous in situ nasal and jejunal recirculation study to compare the intrinsic absorptivity and the property of absorption sites revealed that the absorption of $AZT-TA{\beta}CD\;(N:35.35{\pm}1.08%,\;J:27.47{\pm}1.18%)$ was more than that of $AZT\;(N:16.89{\pm}2.25%,\;J:15.86{\pm}2.33%)$. The above results suggest that $TA{\beta}CD$ which is a hydrophobic cyclodextrin may serve as sustained release carrier with absorption enhancing effect.

  • PDF

The Evaluation of Hydrogenation Properties on $MgH_x-Fe_2O_3$ Composite by Mechanical Alloying (기계적 합금화법으로 제조된 $MgH_x-Fe_2O_3$ 복합재료의 수소화 특성 평가)

  • Seok, Song;Cho, Kyoung-Won;Hong, Hae-Whan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.1
    • /
    • pp.26-31
    • /
    • 2007
  • Hydrogen has a high potential to be a renewable substitute for fossil fuels, because of its high gravimetric energy density and environment friendliness. In particular, Magnesium have attracted much interest since their hydrogen capacity exceeds that of known metal hydrides. One of the approaches to improve the kinetic is addition of metal oxide. In this paper, the effect of $Fe_2O_3$ concentration on the kinetics of Mg hydrogen absorption reaction was investigated. $MgH_x-Fe_2O_3$ composites have been synthesized by hydrogen induced mechanical alloying. The powder synthesized was characterized by XRD, SEM and simultaneous TG, DSC analysis. The hydrogenation behaviors were evaluated by using a sievert's type automatic PCT apparatus. Absorption and desorption kinetics of Mg catalyzed with 5,10 mass% $Fe_2O_3$ are determined at 423, 473, 523, 573, 623K.

Simultaneous Analysis of Cholesterol Oxidation Products (COPs) in Powdered Milk Using HPLC/UV-Vis

  • Lee, Jin Joo;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2787-2794
    • /
    • 2013
  • Cholesterol and cholesterol oxidation products (COPs) may accumulate in foods of animal origin during processing or storage. An effective and sensitive analytical method was developed by increasing the UV absorption of compounds through derivatization by attaching a chromophore to the functional groups of cholesterols (cholesterol, 20-hydroxycholesterol, 7-ketocholesterol, cholestane-$3{\beta}$-$5{\alpha}$-$6{\beta}$-triol, 25-hydroxycholesterol, and $5,6{\alpha}$-epoxycholesterol). The influences of the reaction time, volume of reaction solvent, amounts of derivatizing reagent, and extraction solvents were investigated, as they may influence the reaction and extraction yield. The derivatized COPs were analyzed simultaneously on a C18 column (2.1 mm i.d. ${\times}$ 100 mm length, $3.5{\mu}m$ particle size) using a gradient elution with water and acetonitrile. The derivatized COPs showed increased sensitivity and selectivity in HPLC/UV-Vis. The LOD and LOQ were in the concentration ranges of 0.018-0.55 mg/kg and 0.059-1.84 mg/kg from the powdered milk. And the accuracy and precision were 78.1-116.7% and 1.1-9.9%, respectively.

Simultaneous HPLC Analysis of Arachidonic Acid Metabolites in Biological Samples with Simple Solid Phase Extraction

  • Kim, Hyung-Gun;Huh, Young-Na;Park, Kun-Suk
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.6
    • /
    • pp.779-786
    • /
    • 1998
  • A reversed-phase high-performance liquid chromatogrphy (RP-HPLC) has been developed to analyze the metabolites of arachidonic acid based on the specificities of ultraviolet absorption of these various metabolites and is sensitive to the nanogram level. This procedure makes it possible to extract complex mixtures of eicosanoids efficiently with a single step and to analyze them simultaneously by RP-HPLC from biological samples using octadesylsilyl silica extraction column and $PGB_2$ as an internal standard. The cyclooxygenase products {prostaglandin $(PG)D_2,\;PGE_1,\;PGE_2,\;PGF_{1{\alpha}},\;PGF{2{\alpha}},\;6-keto-PGF_{1{\alpha}},$ and thromboxane $B_2(TXB_2)}$ and lipid peroxidation product, isoprostanes, of arachidonic acid were monitored by one isocratic HPLC system at 195 nm wavelength. The lipoxygenase products ${leukotriene(LT)B_4,\;LTC_4,\;LTD_4,$ and 5-hydroxyeicosatetraenoic acid (5-HETE), 12-HETE, 15-HETE} were measured by another isocratic HPLC system at 280 nm for LTs and 235 nm for HETEs. This method provides a simple and reliable way to extract and assess quantitatively the final arachidonic acid metabolites.

  • PDF