• Title/Summary/Keyword: Simultaneous Absorption

Search Result 124, Processing Time 0.026 seconds

Absorption Mechanism of Cefixime through the Nasal Cavity and Jejunum in Rats (흰쥐의 비강과 공장에서의 세픽심의 흡수기전)

  • Park, Gee-Bae;Roh, Hyun-Goo;Lee, Kwang-Pyo
    • YAKHAK HOEJI
    • /
    • v.38 no.2
    • /
    • pp.114-122
    • /
    • 1994
  • A study on the absorption mechanism of cefixime(CF), an oral ${\alpha}-amino$ group deficient cephalosporin antibiotic, has been undertaken through the rat jejunum and nasal cavity using an in situ simultaneous perfusion technique developed in our laboratory. CF was well absorbed in the jejunum and nasal cavity of rats at pH 5.0, but not at pH 7.0. CF absorption was studied over four orders of magnitude in concentration to determine saturability. Disappearance of CF in the perfusate followed first-order kinetics at all tested concentrations. The apparent first-order absorption rate constant was found to be dependent on the concentration over the range of $0.1\;mM{\sim}3\;mM$ in the jejunum and nasal cavity of rats. Inhibitors were added to determine the competitive inhibition of CF absorption. The presence of L-tyrosine, L-phenylalanine, alanine-alanine, glycine-glycine and cefadroxil produced the significant inhibition of CF absorption in the nasal cavity and jejunum. However, there was no evidence of the inhibition in the presence of cefazolin. In addition, The CF absorption in the nasal cavity and jejunum was inhibited significantly by ouabain and 2,4-dinitrophenol(DNP). This study suggested that CF is absorbed across the rat nasal cavity and jejunum by carrier-mediated transport mechanism and energy consuming system.

  • PDF

Analysis of Heat and Mass Transfer on Helical Absorber (헬리컬 흡수기의 흡수 열물질전달 해석)

  • Gwon, O-Gyeong;Im, Jong-Geuk;Yun, Jeong-In;Kim, Seon-Chang;Yun, Jae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.11
    • /
    • pp.1428-1436
    • /
    • 2000
  • The absorption of vapor involves simultaneous heat and mass transfer in the vapor/liquid system. In this paper, a numerical study for vapor absorption process into LIBr-H$_2$O solution film flowing over helical absorber has been carried out. Axisymmetric cylindrical coordinate system was adopted to model the helical tube and the transport equations were solved by the finite volume method. The effects of operating conditions, such as the cooling water temperature. the system pressure, the film Reynolds number and the solution inlet concentration have been investigated in view of the absorption mass flux and the total absorption mass flux and the total absorption rate. The results for the temperature and concentration profiles, as well as the local absorption mass flux at the helical absorber are presented. It is shown that solution inlet concentration affected other than operation conditions for a mass flux.

Species Concentration Measurement Technique Using Wavelength Modulation Absorption Spectroscopy (파장변조 광흡수 분광법을 이용한 농도 계측 기법)

  • Ahn, J.H.;Kim, Y.M.
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.67-76
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, reasonable cost, robustness, and ease of use. In addition, diode lasers we fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develop new gas sensing system and to verify feasibility of this system. Wavelength modulation spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

Approximate solutions on the absorption process of an aqueous LiBr falling film : effects of vapor flow (리튬브로마이드 수용액 유하액막의 흡수과정에 대한 근사 해법 : 증기 유동의 영향)

  • Kim, B.J.;Lee, C.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.144-152
    • /
    • 1997
  • Film absorption involves simultaneous heat and mass transfer in the vapor-liquid system. In the present work, the absorption process of water vapor by an aqueous soluton of LiBr flowing inside of the vertical tube was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the heat and mass transfer rate. Particularly the effects of vapor flow conditions on the absorption process were investigated in terms of the vapor Reynolds number. As the vapor Reynolds number increased, the shear stress at the vapor-solution interface also increased. Consequently solution film became thinner at higher vapor flowrate under the co-currentflow condition. Thinner film was capable of higher heat transfer to the wall and leaded to higher absorption rate of the water vapor into the solution film.

  • PDF

Non-absorbable Gas Effects on Heat and Mass Transfer in Falling Film Absorption

  • Kim, Byongjoo;Lee, Chunkyu
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.581-589
    • /
    • 2003
  • Film absorption involves simultaneous heat and mass transfer in the gas-liquid system. While the non-absorbable gas does not participate directly In the absorption process. its pretence does affect the overall heat and mass transfer. An experimental study was performed to investigate the heat and mass transfer characteristics of LiBr-H$_2$O solution flow ing over 6-row horizontal tubes with the water vapor absorption in the pretence of non-absorbable gases. The volumetric concentration of non-absorbable gas, air, was varied from 0.17 to 10.0%. The combined effects of the solution flow rate and its concentration on the heat and mass transfer coefficients were also examined. The presence of 2% volumetric concentration of air resulted in a 25% reduction in the Nusselt number and 41% reduction in the Sherwood number Optimum film Reynolds number was found to exist at which the heat and mass transfer reach their maximum value independent of air contents. Reduced Nusselt and Sherwood numbers. defined as the ratio of Nusselt and Sherwood numbers at given non-absorbable gas content to that with pure water vapor, were correlated to account for the reduction in the heat and mass transfer due to non-absorbable gases in a falling film absorption process.

Species Concentration Measurement Using Diode Laser Absorption Spectroscopy (I) (다이오드 레이저를 이용한 광흡수 농도 계측 기법 (I))

  • Ahn, Jae-Hyun;Kim, Yong-Mo;Kim, Se-Won
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, resonable cost, robustness, and ease of use. In addition, diode lasers are fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develope a new gas sensing system and to verify feasibility of this system. Wavelength and power characteristics as a function of injection current and temperature are experimentally found out. Direct absorption spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

Simultaneous Kinetic Spectrophotometric Determination of Sulfite and Sulfide Using Partial Least Squares (PLS) Regression

  • Afkhami, Abbas;Sarlak, Nahid;Zarei, Ali Reza;Madrakian, Tayyebeh
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.863-868
    • /
    • 2006
  • The partial least squares (PLS-1) calibration model based on spectrophotometric measurement, for the simultaneous determination of sulfite and sulfide is described. This method is based on the difference between the rate of the reaction of sulfide and sulfite with Malachite Green in pH 7.0 buffer solution and at 25 ${^{\circ}C}$. The absorption kinetic profiles of the solutions were monitored by measuring the decrease in the absorbance of Malachite Green at 617 nm in the time range 10-180 s after initiation of the reactions with 2 s intervals. The experimental calibration matrix for partial least squares (PLS-1) calibration was designed with 24 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range 0.030-1.5 and 0.030-1.2 $\mu$g m$L ^{-1}$ for sulfite and sulfide, respectively. The proposed method was successfully applied to simultaneous determination of sulfite and sulfide in water samples and whole human blood.

Simultaneous Imaging Using Combined Optical Coherence Tomography (OCT) and Photoacoustic Microscopy (PAM) (광간섭 단층 촬영 장치와 광음향 현미경의 결합을 통한 동시 이미지 획득 연구)

  • Kim, Sehui;Lee, Changho;Han, Seonghoon;Kang, Hyun Wook;Oh, Junghwan;Kim, Jeehyun;Kim, Chulhong
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.91-96
    • /
    • 2013
  • In this study, we developed an integrated optical coherence tomography - photoacoustic microscopy (OCT-PAM) system to simultaneously provide optical absorption and scattering information. Two different laser sources, such as a pulsed laser for PAM and a superluminescent diode for OCT, were employed to implement the integrated OCT-PAM system. The performance of the OCT-PAM system was measured by imaging carbon fibers. We then imaged black and white hairs to demonstrate the simultaneous OCT-PAM imaging capabilities. As a result, OCT can produce 3-D images of both black and white hairs, whereas PAM is only able to image the black hair due to strong optical absorption of black hair.