• Title/Summary/Keyword: Simulation operation

Search Result 5,629, Processing Time 0.032 seconds

The development of water circulation model based on quasi-realtime hydrological data for drought monitoring (수문학적 가뭄 모니터링을 위한 실적자료 기반 물순환 모델 개발)

  • Kim, Jin-Young;Kim, Jin-Guk;Kim, Jang-Gyeng;Chun, Gun-il;Kang, Shin-uk;Lee, Jeong-Ju;Nam, Woo-Sung;Kwon, Hyun-Han
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.8
    • /
    • pp.569-582
    • /
    • 2020
  • Recently, Korea has faced a change in the pattern of water use due to urbanization, which has caused difficulties in understanding the rainfall-runoff process and optimizing the allocation of available water resources. In this perspective, spatially downscaled analysis of the water balance is required for the efficient operation of water resources in the National Water Management Plan and the River Basin Water Resource Management Plan. However, the existing water balance analysis does not fully consider water circulation and availability in the basin, thus, the obtained results provide limited information in terms of decision making. This study aims at developing a novel water circulation analysis model that is designed to support a quasi-real-time assessment of water availability along the river. The water circulation model proposed in this study improved the problems that appear in the existing water balance analysis. More importantly, the results showed a significant improvement over the existing model, especially in the low flow simulation. The proposed modeling framework is expected to provide primary information for more realistic hydrological drought monitoring and drought countermeasures by providing streamflow information in quasi-real-time through a more accurate natural flow estimation approach with highly complex network.

Geomechanical Stability of Underground Lined Rock Caverns (LRC) for Compressed Air Energy Storage (CAES) using Coupled Thermal-Hydraulic-Mechanical Analysis (열-수리-역학적 연계해석을 이용한 복공식 지하 압축공기에너지 저장공동의 역학적 안정성 평가)

  • Kim, Hyung-Mok;Rutqvist, Jonny;Ryu, Dong-Woo;Synn, Joong-Ho;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.394-405
    • /
    • 2011
  • In this paper, we applied coupled non-isothermal, multiphase fluid flow and geomechanical numerical modeling using TOUGH-FLAC coupled analysis to study the complex thermodynamic and geomechanical performance of underground lined rock caverns (LRC) for compressed air energy storage (CAES). Mechanical stress in concrete linings as well as pressure and temperature within a storage cavern were examined during initial and long-term operation of the storage cavern for CAES. Our geomechanical analysis showed that effective stresses could decrease due to air penetration pressure, and tangential tensile stress could develop in the linings as a result of the air pressure exerted on the inner surface of the lining, which would result in tensile fracturing. According to the simulation in which the tensile tangential stresses resulted in radial cracks, increment of linings' permeability and air leakage though the linings, tensile fracturing occurred at the top and at the side wall of the cavern, and the permeability could increase to $5.0{\times}10^{-13}m^2$ from initially prescribed $10{\times}10^{-20}m^2$. However, this air leakage was minor (about 0.02% of the daily air injection rate) and did not significantly impact the overall storage pressure that was kept constant thanks to sufficiently air tight surrounding rocks, which supports the validity of the concrete-lined underground caverns for CAES.

Design and Implementation of License Web Courseware based on the Cognitive Apprenticeship Theory (인지적 도제이론에 기반한 자격증 웹 코스웨어 설계 및 구현)

  • Kim, Nam-Ju;Kang, Yun-Hee;Kim, Deok-Hwan;Lee, Ju-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.3
    • /
    • pp.21-30
    • /
    • 2006
  • This study applies the cognitive apprenticeship theory a representative learning theory of constructivism. to design and create a web courseware for data device operator license. to enable research that begins with peripheral participation in Problem solving and ends with full participation and initiative, to act as a medium for assisting students in learning, to enable adaptation to actual situations through simulation studies, to allow aggressive interaction, and to help reinforce the level of data processing with regard to learning. The student was made to evaluate learning materials at real time for feedback on insufficient areas, to enable effective learning. The study was done by offering a web courseware without applying the cognitive apprenticeship theory and a web courseware with the cognitive apprenticeship theory, which was followed by an evaluation on study achievement level and learning behavior and then a survey was done after the evaluations. The results of this study were first, the learning group with web courseware applying cognitive apprenticeship theory showed more effect in improving learning achievement than the group with web courseware without the cognitive apprenticeship theory. Secondly, learning with web courseware applying cognitive apprenticeship theory was more effective for improving learning behavior.

  • PDF

Low Power TLB Supporting Multiple Page Sizes without Operation System (운영체제 도움 없이 멀티 페이지를 지원하는 저전력 TLB 구조)

  • Jung, Bo-Sung;Lee, Jung-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.12
    • /
    • pp.1-9
    • /
    • 2013
  • Even though the multiple pages TLB are effective in improving the performance, a conventional method with OS support cannot utilize multiple page sizes in user application. Thus, we propose a new multiple-TLB structure supporting multiple page sizes for high performance and low power consumption without any operating system support. The proposed TLB is organised as two parts of a S-TLB(Small TLB) with a small page size and a L-TLB(Large TLB) with a large page size. Both are designed as fully associative bank structures. The S-TLB stores small pages are evicted from the L-TLB, and the L-TLB stores large pages including a small page generated by the CPU. Each one bank module of S-TLB and L-TLB can be selectively accessed base on particular one and two bits of the virtual address generated from CPU, respectively. Energy savings are achieved by reducing the number of entries accessed at a time. Also, this paper proposed the simple 1-bit LRU policy to improve the performance. The proposed LRU policy can present recently referenced block by using an additional one bit of each entry on TLBs. This method can simply select a least recently used page from the L-TLB. According to the simulation results, the proposed TLB can reduce Energy * Delay by about 76%, 57%, and 6% compared with a fully associative TLB, a ARM TLB, and a Dual TLB, respectively.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.

Development of Information Security Practice Contents for Ransomware Attacks in Digital Twin-Based Smart Factories (디지털트윈 기반의 스마트공장에서 랜섬웨어 공격과 피해 분석을 위한 정보보안 실습콘텐츠 시나리오 개발)

  • Nam, Su Man;Lee, Seung Min;Park, Young Sun
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.31 no.5
    • /
    • pp.1001-1010
    • /
    • 2021
  • Smart factories are complex systems which combine latest information technology (IT) with operation technology (OT). A smart factory aims to provide manufacturing capacity improvement, customized production, and resource reduction with these complex technologies. Although the smart factory is able to increase the efficiency through the technologies, the security level of the whole factory is low due to the vulnerability transfer from IT. In addition, the response and restoration of the business continuity plan are insufficient in case of damage due to the absence of factory security experts. The cope with the such problems, we propose an information security practice content for analyzing the damage by generating ransomware attacks in a digital twin-based smart factory similar to the real world. In our information security content, we introduce our conversion technique of physical devices into virtual machines or simulation models to build a practical environment for the digital twin. This content generates two types of the ransomware attacks according to a defined scenario in the digital twin. When the two generated attacks are successfully completed, at least 8 and 5 of the 23 virtual elements are take damage, respectively. Thus, our proposed content directly identifies the damage caused by the generation of two types of ransomware in the virtual world' smart factory.

A Study on Detection Algorithm of Open Phase Fault in Grid-Connected Transformer for PV System (태양광전원 연계용변압기의 결상사고 검출 알고리즘에 관한 연구)

  • Kang, Kab-Seok;Tae, Dong-Hyun;Lee, Hu-Dong;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.22-33
    • /
    • 2021
  • In the case of open phase faults caused by the disconnection of distribution feeders interconnected to a PV system, many problems can occur depending on the core type and wiring method of the grid-connected transformers. Moreover, open phase faults are difficult to detect because the open phase voltage of the existing protection relay (Open Phase Relay (47)) can be maintained, even though a disconnection fault occurred, depending on the wiring method and the iron core type of the grid-connected transformer for a PV system. Therefore, this paper proposes a novel algorithm to detect open phase faults by comparing the currents and phases between the primary and secondary sides of a grid-connected transformer. In addition, this paper presents the modeling of a distribution system and protection devices for detecting open phase faults using PSCAD/EMTDC S/W, and implements a test protection device for detecting open phase faults based on the above-mentioned modeling. The simulation and test results confirmed that the proposed algorithm is useful for detecting open phase faults according to the wiring method and iron core type of grid-connected transformer for a PV system because operation slope and unbalance rate of the primary current exceed the setting value (30[%]) of the protection device.

Content analysis on online non-face-to-face adult nursing practice experienced by graduating nursing students in the ontact era (온택트 시대의 졸업학년 간호대학생이 경험한 온라인 비대면 성인간호학실습에 대한 내용분석)

  • Lim, So-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.195-205
    • /
    • 2021
  • As Coronavirus disease 2019 (COVID-19) became a pandemic, most nursing departments in Korea implemented online non-face-to-face practices rather than the existing practice method. This study was a qualitative study that analyzed the reflection diaries written by participants to understand what they experienced in the online non-face-to-face adult nursing practice process. The online non-face-to-face adult nursing practice was 90 hours for two credits and nine hours per day for a total of 10 days. This online practice consisted of computer-based simulation practice, computer-based nursing skills practice, video and educational material production, real-time online quiz, online lecture video, and discussion. As a result of analyzing the reflection diary, six categories, 13 subcategories, and 33 codes were derived. The six categories were 'Experience of various situations', 'Experience of new study', 'Fulfillment for the clinical practice', 'Building relations with professors', 'Fear of being a pre-nurse', and 'Ambivalence for the non-face-to-face practice'. These results are significant in that in the post-corona era, adult nursing practice was conducted as a non-face-to-face practice rather than a clinical practice institution, and various educational methods were operated. This study is expected to provide important basic data for the development and operation of non-face-to-face adult nursing practice.

A Study on Characteristics and Modeling of CMV by Grounding Methods of Transformer for ESS (ESS용 변압기의 접지방식에 의한 CMV 모델링 및 특성에 관한 연구)

  • Choi, Sung-Moon;Kim, Seung-Ho;Kim, Mi-Young;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.587-593
    • /
    • 2021
  • Since 2017, a total of 29 fire accidents have occurred in energy storage systems (ESSs) as of June 2020. The common mode voltage (CMV) is one of the electrical hazards that is assumed to be a cause of those fire accidents. Several cases of CMV that violate the allowable insulation level of a battery section are being reported in actual ESS operation sites with △-Y winding connections. Thus, this paper evaluates the characteristics of CMV. An ESS site was modeled with an AC grid, PCS, and battery sections using PSCAD/EMTDC software. As a result of a simulation based on the proposed model, it was confirmed that characteristics of CMV vary significantly and are similar to actual measurements, depending on the grounding method of the internal transformer for PCS. The insulation level of the battery section may be severely degraded as the value of CMV exceeds the rated voltage in case of a grounding connection. It was found that the value of CMV dramatically declines when the internal transformer for PCS is operated as non-grounding connection, so it meets the standard insulation level.

A Study on Capacity of Electric Propulsion System by Load Analysis of 6,800TEU Container Ship (6,800TEU 컨테이너선의 부하분석을 통한 전기추진시스템 용량 연구)

  • Jang, Jae-Hee;Son, Na-Young;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.42 no.6
    • /
    • pp.437-445
    • /
    • 2018
  • IMO (International Maritime Organization) has been strengthening the regulations of ship emission gas such as sulfur oxides (SOX), nitrogen oxides (NOX) and carbon dioxides (CO2) to protect the marine environment. Especially, ECA (Emission Control Area) has been set and operated in the USA and US. As a countermeasure against these environmental regulations, the demand for environmentally, friendly and highly efficient vessels has led to a growing interest in technology related research with respect to electric propulsion systems capable of reducing exhaust gas. Container ships were excluded from the application coverage of the electric propulsion systems for reasons of operation at economical speed. However, in the future, the need for electric propulsion system is expected to rise, because it is easy to monitor and control so that it can be an applicate to smart ship which are represented by fourth industrial revolution technology. In this study, research was carried out to design a generator and battery capacity through the load analysis of the 6,800TEU container ship to apply the electric propulsion system of the container ship. A capacity design based on the load analysis has an advantage that the generator can be operated in a high efficiency section through the load distribution control using the battery.