• Title/Summary/Keyword: Simpson's method

Search Result 48, Processing Time 0.029 seconds

Simpson Style Caricature based on MLS

  • Lee, Jiye;Byun, Hae Won
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.6
    • /
    • pp.1449-1462
    • /
    • 2013
  • We present a novel approach to producing facial caricature with Simpson cartoon style based on Moving Least Squares (MLS). We take advantage of employing the caricature stylization rule of caricature artist, Justin. Our method allows Simpson-style cartoon character similar to user's features by using Justin's technique, which is a set of caricature stylization rules. Our method transforms input photo image into Simpson style caricature by using MLS approximation. The unique characteristics of user in the photo can be detected by comparing to the mean face feature and the input face feature extracted by AAM(Active Appearance Model). To exaggerate the detected unique characteristics, we set up the exaggeration rules using Justin's technique. In addition, during the cartooning process, user's hairs and accessories are used to the deformed image to make a close resemblance. Our method preserves the reliable and stylized caricature through the exaggeration rules of the actual caricature artist's techniques. From this study, we can easily create a Simpson-style cartoon caricature to resemble user's features by combining a caricature with existing cartoon researches.

A Study on The State Estimation of The Time-Invariant Linear Systems via The Improved Parameter Estimation Method for The Block Pulse Coefficients (개선된 블록 펄스 계수 추정 기법을 이용한 선형 시불변계의 상태 추정에 관한 연구)

  • Kim, Tai-Hoon;Kim, Jin-Tae;Chung, Je-Wook;Sim, Jae-Seon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.4
    • /
    • pp.137-143
    • /
    • 2002
  • Because Block Pulse functions are used in a variety of fields such as the analysis and controller design of systems, it is necessary to find the more exact value of the Block Pulse series coefficients. This paper presents a method for the state estimation of the time-invariant linear systems via the improved estimation method for the Block Pulse coefficients by using the Simpson's rule. The proposed method using the Simpson's rule improve the accuracy of the Block Pulse coefficients.

Usefulness of ultrasound contrast media for cardiac output measurement with echocardiography

  • Yun, Je Woong;Yeon, Seong Chan;Lee, Hee Chun
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.1
    • /
    • pp.47-52
    • /
    • 2015
  • The purpose of this study was to determine if contrast media would enhance visualization of the endocardium for assessment of left ventricle (LV) function. In addition, differences between pre- and post-contrast evaluation for the cardiac output measurements including the modified Simpson's method and automated contour tracking (ACT) method were examined. Ten clinically healthy adult beagle dogs (three males and seven females) between 2~3 years old and weighing 6.6~10.8 kg were used. Echocardiographic examinations were performed to compare pre- and post-contrast LV endocardium visualization using a segmental scoring method. Two different methods for measuring cardiac output were also compared. LV visualization was significantly enhanced in post-contrast echocardiography (p < 0.01). Significant differences between pre- and post-contrast measurements for the modified Simpson's method (p < 0.05) were also observed. No significant difference was found for the ACT method. Contrast echocardiography provides better LV chamber opacification and significantly improves wall segment visualization. Furthermore, contrast echocardiography for measuring cardiac output is helpful for the modified Simpson's method.

The Energy Conserving Algorithm of the System Acted by an Exponential Impact Force (지수형 충격력을 받는 시스템의 에너지보존 알고리듬)

  • 윤성호
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.3
    • /
    • pp.311-319
    • /
    • 2003
  • This paper aims at investigating the exact dynamic response of the system undergoing a exponential impact force from the viewpoints of conservations of momentum and energy. The midpoint method applied in the Newmark's family algorithm is found to be identical to the case of the application of the trapezoidal method which provides conservations of momentum and energy. For the linear impact force the mid point, the trapezoidal and the (n+1) point method exactly meet the conservation characteristics independent of the size of integration interval. On the other hand, constants for the dynamic motion resulting from the nonlinear impact are underestimated or overestimated by these method mentioned above. To overcome this indispensible error, the Simpson 1/3 method as one of multi step methods whose advantages is to use longer time interval with the same number of evaluation functions is adopted for the exact conservations of momentum and energy. Moreover, the suggested method is expected to expand the similar algorithm for the general dynamic motion including finite rotations.

A novel two sub-stepping implicit time integration algorithm for structural dynamics

  • Yasamani, K.;Mohammadzadeh, S.
    • Earthquakes and Structures
    • /
    • v.13 no.3
    • /
    • pp.279-288
    • /
    • 2017
  • Having the ability to keep on yielding stable solutions in problems involving high potential of instability, composite time integration methods have become very popular among scientists. These methods try to split a time step into multiple sub-steps so that each sub-step can be solved using different time integration methods with different behaviors. This paper proposes a new composite time integration in which a time step is divided into two sub-steps; the first sub-step is solved using the well-known Newmark method and the second sub-step is solved using Simpson's Rule of integration. An unconditional stability region is determined for the constant parameters to be chosen from. Also accuracy analysis is perform on the proposed method and proved that minor period elongation as well as a reasonable amount of numerical dissipation is produced in the responses obtained by the proposed method. Finally, in order to provide a practical assessment of the method, several benchmark problems are solved using the proposed method.

Comparative Evaluation of Cardiac Output using Echocardiography in Beagle Dogs (비글견에서 심초음파를 이용한 심박출량 측정에 관한 비교 연구)

  • Park, Kitae;Yeon, Seongchan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.384-390
    • /
    • 2012
  • Echocardiographic measurements of cardiac output, including the modified Simpson's method, Automated Contour Tracking(ACT) method, and left ventricular outflow method are well described methods of evaluating cardiac function due to its reliability and the benefits of its non-invasive technique in human medicine. The purpose of this study was to evaluate the accuracy of an echocardiography estimate of cardiac output in isoflurane-anesthetized beagle dogs and was to compare the ACT method to the other methods used in measurement of cardiac output. In healthy beagle dogs, cardiac output results by echocardiography estimate methods showed an excellent correlations with those by the thermodilution method (The modified Simpson's method : r = 0.815, $r^2=0.665$, y = 0.434x + 0.311 ; ACT method : r = 0.86, $r^2=0.748$, y = 0.391x + 0.242 ; ventricular outflow method : r = 0.691, $r^2=0.478$, y = 0.593x + 0.242). Among the results obtained, the ACT method showed the highest correlation coefficient. In conclusion, our study demonstrated that echocardiography estimate methods did not prove to be suitable in accurately measuring absolute cardiac output values but showed an excellent correlation with thermodilution method. Therefore, by using the measurement of cardiac output as supplemental data, echocardiography estimate methods can be used for detection and correction of hemodynamic disturbances during emergency and anesthesia in veterinary practice.

Strongest Beams having Constant Volume Supported by Clamped-Clamped and Clamped-Hinged Ends (고정-고정 및 고정-회전 지점으로 지지된 일정체적 최강보)

  • Lee, Byoung Koo;Lee, Tae Eun;Shin, Seong Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3A
    • /
    • pp.251-258
    • /
    • 2009
  • This paper deals with the strongest beams with the solid regular polygon cross-section, whose volumes are always held constant. The differential equation of the elastic deflection curve of such beam subjected to the concentrated and trapezoidal distributed loads are derived and solved by using the double integration method. The Simpson's formula was used to numerically integrate the differential equation. In the numerical examples, the clamped-clamped and clamped-hinged ends are considered as the end constraints and the linear, parabolic and sinusoidal tapers are considered as the shape function of cross sectional depth. As the numerical results, the configurations, i.e. section ratios, of the strongest beams are determined by reading the section ratios from the numerical data obtained in this study, under which static maximum behaviors become to be minimum.

A study on the comparison of accuracy of evaluation method of earthwork volume using on DTM (DTM에서 토공량의 산정방식에 따른 토공량의 정확도 비교)

  • 문일석;전재홍;조규전
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.2
    • /
    • pp.277-283
    • /
    • 1995
  • In the study, an accuracy of earthwork volume is evaluated according to different methods of the calculation with different criteria. The criteria applied to this study are a interpolation method, a grid intavals and the method of earthwork evaluation. A numerical test has performed on two different terrain models with four different methods of calculation in the earthwork volume and two different grid intervals. The end area method, prismoidal formular, Simpson's formular, and middle area method are applied to the calculation of the earthwork volume. As a result of this study, it is showed that the moving average method with the first order term gives the most accurate result in interpolation, and that also the prismoidal formular and Simpson's formular gives more accurate result than average and area method and middle area method in the calculation of earthwork volume.

  • PDF

A Case Report of Echocardiography of Non-rheumaic Giant Left Atrium (비-류마티스성 거대 좌심방의 심장 초음파 검사 증례 보고)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.443-451
    • /
    • 2022
  • In this case, non-rheumatic GLA was observed and it was intended to report a case of ultrasound examination. The case patient, a 60-year-old male, visited the emergency room for dyspnea and palpitations. For radiology examination, chest X-ray examination and CT examination were performed, and a giant left atrium was confirmed. Echocardiography was performed to find the cause of the giant left atrium. Echocardiography The size and volume of the left atrium were evaluated by Simpson's method, and the giant left atrium with LVEDVI 6 times larger than that of the general giant left atrium could be evaluated. Also, a giant left atrium in a patient without rheumatic heart disease is evaluated as a very rare case. Since non-rheumatic giant left atrium could be caused by functional mitral regurgitation, diastolic dysfunction. It was confirmed that ultrasonography, which allowed both morphological and hemodynamic examinations, could be a useful case.

Evaluation of Influence of Anesthetics on Canine Stroke Volume and Feasibility of ACT Using Echocardiography (개에서 심초음파 검사시 마취제가 일회심박출량에 미치는 영향과 ACT법의 적용가능성 평가)

  • Park, Ki-Tae;Lee, Eun-Sung;Jung, Dong-In;Yeon, Seong-Chan;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.264-267
    • /
    • 2013
  • Stroke volume (SV) is an important parameter for monitoring of a critically ill animal and is echocardiographically measured using the modified Simpson's method, automated contour tracking (ACT) method and left ventricular outflow method. The purpose of this study was to evaluate the effect of anesthesia (isoflurane) on the SV during echocardiographic examination and to evaluate the feasibility of ACT method for measuring the stroke volume without anesthesia (conscious state). Ten clinically healthy adult Beagle dogs (3 male and 7 female, weighing 6.6-10.8 kg, aged 2-3 years old) were enrolled. Our study found that the dogs anesthetized have a significantly lower SV, compared to the SV of dogs unanesthetized, regardless of methods measuring SV. In addition, in the dogs without anesthesia, the SV measured by ACT method was significantly lower than the other two methods. This result implies that the anesthesia may significantly lower the SV. Thus, the measurement of SV under anesthesia may not be adequate in veterinary field. Furthermore because the ACT method measured SV significantly lower than other two methods, this method may be inappropriate for measuring SV in even conscious dogs.