• 제목/요약/키워드: Simplified assessment

검색결과 266건 처리시간 0.029초

부분 무치악 하악골의 치조골 및 기저골 변화에 관한 방사선학적 평가 (Radiologic assessment of alveolar and basal bone change of partially edentulous mandible)

  • 박창서;김기덕
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.141-145
    • /
    • 2002
  • Purpose : The purpose of this study was to propose standard values for alveolar and basal bone in normal adult mandibles, and radiologically analyze the remodeling process of the edentulous mandible by examining molar areas and comparing them to the established normal values. Materials and Methods : Panoramic and CT scans of mandible were performed on 20 normal adults and 20 edentulous or partially edentulous adults. In both groups, arch half diameter and distance of alveolar bone were measured. Also the distance from the mandibular canal to the caudal edges, the buccal and lingual external borders of basal bone, were measured. A statistical comparison between the mean values of normal and edentulous mandibles was carried out in the selected areas. Results : There was evidence of decreasing arch half diameter and distance in the edentulous mandible, but statistically no significant change was seen between the normal and edentulous alveolar bone. There was evidence of decreasing buccal basal bone and increasing in the lingual basal bone in the edentulous mandible. A statistically significant difference between normal and edentulous mandibles was noted in the buccal basal bone. Conclusion: There was an inward and forward atrophic change of the edentulous mandibular molar area compared to the control. CT scanning required the use of sophisticated and expensive procedures to analyze the remodeling process of edentulous mandibles. Consequently, the development and application of a more simplified and objective radiographic procedure for broad and long-term study of remodeling procedures of edentulous mandible was recommended.

  • PDF

On the assessment of modal nonlinear pushover analysis for steel frames with semi-rigid connections

  • Zarfam, Panam;Mofid, Massood
    • Structural Engineering and Mechanics
    • /
    • 제32권3호
    • /
    • pp.383-398
    • /
    • 2009
  • Applying nonlinear statistical analysis methods in estimating the performance of structures in earthquakes is strongly considered these days. This is due to the methods' simplicity, timely lower cost and reliable estimation in seismic responses in comparison with time-history nonlinear dynamic analysis. Among nonlinear methods, simplified to be incorporated in the future guidelines, Modal Pushover Analysis, known by the abbreviated name of MPA, simply models nonlinear behavior of structures; and presents a very proper estimation of nonlinear dynamic analysis using lateral load pattern appropriate to the mass. Mostly, two kinds of connecting joints, 'hinge' and 'rigid', are carried out in different type of steel structures. However, it should be highly considered that nominal hinge joints usually experience some percentages of fixity and nominal rigid connections do not employ totally rigid. Therefore, concerning the importance of these structures and the significant flexibility effect of connections on force distribution and elements deformation, these connections can be considered as semi-rigid with various percentages of fixity. Since it seems, the application and implementation of MPA method has not been studied on moment-resistant steel frames with semi rigid connections, this research focuses on this topic and issue. In this regard several rigid and semi-rigid steel bending frames with different percentages of fixity are selected. The structural design is performed based on weak beam and strong column. Followed by that, the MPA method is used as an approximated method and Nonlinear Response History Analysis (NL-RHA) as the exact one. Studying the performance of semi-rigid frames in height shows that MPA technique offers reasonably reliable results in these frames. The methods accuracy seems to decrease, when the number of stories increases and does decrease in correlation with the semi-rigidity percentages. This generally implies that the method can be used as a proper device in seismic estimation of different types of low and mid-rise buildings with semi-rigid connections.

Application of welding simulation to block joints in shipbuilding and assessment of welding-induced residual stresses and distortions

  • Fricke, Wolfgang;Zacke, Sonja
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권2호
    • /
    • pp.459-470
    • /
    • 2014
  • During ship design, welding-induced distortions are roughly estimated as a function of the size of the component as well as the welding process and residual stresses are assumed to be locally in the range of the yield stress. Existing welding simulation methods are very complex and time-consuming and therefore not applicable to large structures like ships. Simplified methods for the estimation of welding effects were and still are subject of several research projects, but mostly concerning smaller structures. The main goal of this paper is the application of a multi-layer welding simulation to the block joint of a ship structure. When welding block joints, high constraints occur due to the ship structure which are assumed to result in accordingly high residual stresses. Constraints measured during construction were realized in a test plant for small-scale welding specimens in order to investigate their and other effects on the residual stresses. Associated welding simulations were successfully performed with fine-mesh finite element models. Further analyses showed that a courser mesh was also able to reproduce the welding-induced reaction forces and hence the residual stresses after some calibration. Based on the coarse modeling it was possible to perform the welding simulation at a block joint in order to investigate the influence of the resulting residual stresses on the behavior of the real structure, showing quite interesting stress distributions. Finally it is discussed whether smaller and idealized models of definite areas of the block joint can be used to achieve the same results offering possibilities to consider residual stresses in the design process.

전두동 골절 양상에 따른 치료 (Treatment of Frontal Sinus Fractures According to Fracture Patterns)

  • 하주호;김용하;남현재;김태곤;이준호
    • 대한두개안면성형외과학회지
    • /
    • 제10권2호
    • /
    • pp.91-96
    • /
    • 2009
  • Purpose: Frontal sinus fractures are relatively less common than other facial bone fractures. They are commonly concomitant with other facial bone fractures. They can cause severe complications but the optimal treatment of frontal sinus fractures remains controversial. Currently, many principles of treatment were introduced variously. The authors present valid and simplified protocols of treatment for frontal sinus fractures based on fracture pattern, nasofrontal duct injury, and complications. Methods: A retrospective chart review was performed on 36 cases of frontal sinus fractures between January, 2004 and January, 2009. The average age of patients was 33.7 years. Fracture patterns were classified by displacement of anterior and posterior wall, comminution, nasofrontal duct injury. These fractures were classified in 4 groups: I. anterior wall linear fractures; II. anterior wall displaced fractures; III. anterior wall displaced and posterior wall linear fractures; IV. anterior wall and posterior wall displaced fractures. Also, assessment of nasofrontal duct injury was conducted with preoperative coronal section computed tomographic scan and intraoperative findings. Patients were treated with various procedures including open reduction and internal fixation, obliteration, galeal frontalis flap and cranialization. Results: 12 patients are group I (33.3 percent), 14 patient were group II (38.8 percent), group III, IV were 5 each (13.9 percent). Frontal sinus fractures were commonly associated with zygomatic fractures (21.8 percent). 9 patients had nasofrontal duct injury. The complication rate was 25 percent (9 patients), including hypoesthesia, slight forehead irregularity, transient cerebrospinal fluid leakage. Conclusion: The critical element of successful frontal sinus fracture repair is precise diagnosis of the fracture pattern and nasofrontal duct injury. The main goal of management is the restoration of the sinus function and aesthetic preservation.

Comparative volumetric and clinical evaluation of peri-implant sulcular fluid and gingival crevicular fluid

  • Bhardwaj, Smiti;Prabhuji, Munivenkatappa Lakshmaiah Venkatesh
    • Journal of Periodontal and Implant Science
    • /
    • 제43권5호
    • /
    • pp.233-242
    • /
    • 2013
  • Purpose: Peri-implant sulcular fluid (PISF) has a production mechanism similar to gingival crevicular fluid (GCF). However, limited research has been performed comparing their behavior in response to inflammation. Hence, the aim of the present study was to comparatively evaluate PISF and GCF volume with varying degrees of clinical inflammatory parameters. Methods: Screening of patients was conducted. Based on the perimucosal inflammatory status, 39 loaded implant sites were selected from 24 patients, with equal numbers of sites in healthy, peri-implant mucositis, and peri-implantitis subgroups. GCF collection was done from age- and sex-matched dentate patients, selected with gingival inflammatory status corresponding to the implant sites. Assessment of the inflammatory status for dental/implant sites was performed using probing depth (PD), plaque index/modified plaque index (PI/mPI), gingival index/simplified gingival index (GI/sGI), and modified sulcular bleeding index (BI). Sample collection was done using standardized absorbent paper strips with volumetric evaluation performed via an electronic volume quantification device. Results: Positive correlation of the PISF and GCF volume was seen with increasing PD and clinical inflammatory parameters. A higher correlation of GCF with PD (0.843) was found when compared to PISF (0.771). PISF expressed a higher covariation with increasing grades of sGI (0.885), BI (0.841), and mPI (0.734), while GCF established a moderately positive correlation with GI (0.694), BI (0.696), and PI (0.729). Conclusions: Within the limitations of this study, except for minor fluctuations, GCF and PISF volumes demonstrated a similar nature and volumetric pattern through increasing grades of inflammation, with PISF showing better correlation with the clinical parameters.

Computer modelling of fire consequences on road critical infrastructure - tunnels

  • Pribyl, Pavel;Pribyl, Ondrej;Michek, Jan
    • Structural Monitoring and Maintenance
    • /
    • 제5권3호
    • /
    • pp.363-377
    • /
    • 2018
  • The proper functioning of critical points on transport infrastructure is decisive for the entire network. Tunnels and bridges certainly belong to the critical points of the surface transport network, both road and rail. Risk management should be a holistic and dynamic process throughout the entire life cycle. However, the level of risk is usually determined only during the design stage mainly due to the fact that it is a time-consuming and costly process. This paper presents a simplified quantitative risk analysis method that can be used any time during the decades of a tunnel's lifetime and can estimate the changing risks on a continuous basis and thus uncover hidden safety threats. The presented method is a decision support system for tunnel managers designed to preserve or even increase tunnel safety. The CAPITA method is a deterministic scenario-oriented risk analysis approach for assessment of mortality risks in road tunnels in case of the most dangerous situation - a fire. It is implemented through an advanced risk analysis CAPITA SW. Both, the method as well as the resulting software were developed by the authors' team. Unlike existing analyzes requiring specialized microsimulation tools for traffic flow, smoke propagation and evacuation modeling, the CAPITA contains comprehensive database with the results of thousands of simulations performed in advance for various combinations of variables. This approach significantly simplifies the overall complexity and thus enhances the usability of the resulting risk analysis. Additionally, it provides the decision makers with holistic view by providing not only on the expected risk but also on the risk's sensitivity to different variables. This allows the tunnel manager or another decision maker to estimate the primary change of risk whenever traffic conditions in the tunnel change and to see the dependencies to particular input variables.

A prediction model of low back pain risk: a population based cohort study in Korea

  • Mukasa, David;Sung, Joohon
    • The Korean Journal of Pain
    • /
    • 제33권2호
    • /
    • pp.153-165
    • /
    • 2020
  • Background: Well-validated risk prediction models help to identify individuals at high risk of diseases and suggest preventive measures. A recent systematic review reported lack of validated prediction models for low back pain (LBP). We aimed to develop prediction models to estimate the 8-year risk of developing LBP and its recurrence. Methods: A population based prospective cohort study using data from 435,968 participants in the National Health Insurance Service-National Sample Cohort enrolled from 2002 to 2010. We used Cox proportional hazards models. Results: During median follow-up period of 8.4 years, there were 143,396 (32.9%) first onset LBP cases. The prediction model of first onset consisted of age, sex, income grade, alcohol consumption, physical exercise, body mass index (BMI), total cholesterol, blood pressure, and medical history of diseases. The model of 5-year recurrence risk was comprised of age, sex, income grade, BMI, length of prescription, and medical history of diseases. The Harrell's C-statistic was 0.812 (95% confidence interval [CI], 0.804-0.820) and 0.916 (95% CI, 0.907-0.924) in validation cohorts of LBP onset and recurrence models, respectively. Age, disc degeneration, and sex conferred the highest risk points for onset, whereas age, spondylolisthesis, and disc degeneration conferred the highest risk for recurrence. Conclusions: LBP risk prediction models and simplified risk scores have been developed and validated using data from general medical practice. This study also offers an opportunity for external validation and updating of the models by incorporating other risk predictors in other settings, especially in this era of precision medicine.

중환자 중증도 평가도구의 타당도 평가 - APACHE III, SAPS II, MPM II (Comparing the Performance of Three Severity Scoring Systems for ICU Patients: APACHE III, SAPS II, MPM II)

  • 권영대;황정해;김은경
    • Journal of Preventive Medicine and Public Health
    • /
    • 제38권3호
    • /
    • pp.276-282
    • /
    • 2005
  • Objectives : To evaluate the predictive validity of three scoring systems; the acute physiology and chronic health evaluation(APACHE) III, simplified acute physiology score(SAPS) II, and mortality probability model(MPM) II systems in critically ill patients. Methods : A concurrent and retrospective study conducted by collecting data on consecutive patients admitted to the intensive care unit(ICU) including surgical, medical and coronary care unit between January 1, 2004, and March 31, 2004. Data were collected on 348 patients consecutively admitted to the ICU(aged 16 years or older, no transfer, ICU stay at least 8 hours). Three models were analyzed using logistic regression. Discrimination was assessed using receiver operating characteristic(ROC) curves, sensitivity, specificity, and correct classification rate. Calibration was assessed using the Lemeshow-Hosmer goodness of fit H-statistic. Results : For the APACHE III, SAPS II and MPM II systems, the area under the receiver operating characterist ic(ROC) curves were 0.981, 0.978, and 0.941 respectively. With a predicted risk of 0.5, the sensitivities for the APACHE III, SAPS II, and MPM II systems were 81.1, 79.2 and 71.7%, the specificities 98.3, 98.6, and 98.3%, and the correct classification rates 95.7, 95.7, and 94.3%, respectively. The SAPS II and APACHE III systems showed good calibrations(chi-squared H=2.5838 p=0.9577 for SAPS II, and chi-squared H=4.3761 p=0.8217 for APACHE III). Conclusions : The APACHE III and SAPS II systems have excellent powers of mortality prediction, and calibration, and can be useful tools for the quality assessment of intensive care units(ICUs).

AGV-induced floor micro-vibration assessment in LCD factories by using a regressional modified Kanai-Tajimi moving force model

  • Lee, C.L.;Su, R.K.L.;Wang, Y.P.
    • Structural Engineering and Mechanics
    • /
    • 제45권4호
    • /
    • pp.543-568
    • /
    • 2013
  • This study explores the floor micro-vibrations induced by the automated guided vehicles (AGVs) in liquid-crystal-display (LCD) factories. The relationships between moving loads and both the vehicle weights and speeds were constructed by a modified Kanai-Tajimi (MKT) power spectral density (PSD) function whose best-fitting parameters were obtained through a regression analysis by using experimental acceleration responses of a small-scale three-span continuous beam model obtained in the laboratory. The AGV induced floor micro-vibrations under various AGV weights and speeds were then assessed by the proposed regressional MKT model. Simulation results indicate that the maximum floor micro-vibrations of the target LCD factory fall within the VC-B and VC-C levels when AGV moves at a lower speed of 1.0 m/s, while they may exceed the acceptable VC-B level when AGV moves at a higher speed of 1.5 m/s. The simulated floor micro-vibration levels are comparable to those of typical LCD factories induced by AGVs moving normally at a speed between 1.0 m/s and 2.0 m/s. Therefore, the numerical algorithm that integrates a simplified sub-structural multi-span continuous beam model and a proposed regressional MKT moving force model can provide a satisfactory prediction of AGV-induced floor micro-vibrations in LCD factories, if proper parameters of the MKT moving force model are adopted.

축방향 변위가 작용하는 가스 파이프라인 용접부에 존재하는 원주방향 외부표면균열의 변형률 기반 J-적분 및 CTOD 계산 (Estimations of Strain-Based J-integral and CTOD for Circumferential Outer Surface Crack in the Weld of Gas Pipeline Under Axial Displacement)

  • 김경민;박지수;문지희;장윤영;박승현;허남수
    • 한국압력기기공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.100-109
    • /
    • 2020
  • Pipelines subjected to ground movement would be easily exposed to large-scale deformation. Since such deformations may cause the pipeline failure, it is important to ensure the safety of pipelines in various operation conditions. However, crack in weld metal have been considered as one of the main causes that can deteriorate the structural integrity of the pipeline. For this reason, the structural integrity of the pipe containing the crack in the weld should be obtained. In order to assess cracked pipe, J-integral and crack-tip opening displacement(CTOD) have been applied widely as the elastic-plastic fracture mechanics parameters representing crack driving force. In this study, engineering solutions to calculate the J-integral and CTOD of pipes with a circumferential outer surface crack in the weld are proposed. For this purpose, 3-dimensional elastic-plastic finite element(FE) analyses have been performed considering the effect of overmatch and width of weld. The shape of the weld was simplified to I-groove, and axial displacement was employed as for loading condition. Based on FE results, the effects of crack size, material properties and width of weldment on J-integral and CTOD were investigated. Additionally, the J-integral and CTOD for I-groove were compared with those for V-groove to examine the effects of the weld shape, and a proportionality coefficient of J-integral and CTOD was calculated from the results of this paper.